Blogi

ISO 9626

ISO 9626 Loe edasi "

ISO 9626 Stainless Steel Needle Tubing Test ISO 9626 specifies the requirements and test methods for stainless steel needle tubing used in the manufacture of medical devices such as hypodermic needles and cannulas. This international standard ensures that the tubing used in medical applications meets consistent performance and safety requirements. Two key tests under ISO […]

Süsteemi sobivuse testimine Klaasampullide farmakopöa

Süsteemi sobivuse testimine Klaasampullide farmakopöa Loe edasi "

System suitability testing pharmacopoeia is a cornerstone of pharmaceutical quality assurance. When dealing with injectable drugs packaged in glass ampoules, international standards such as ISO 9187 establish strict criteria for hydrolytic resistance, annealing quality, and breaking force. By following these procedures, manufacturers not only meet regulatory expectations but also safeguard patient safety and product reliability.

Pakendi kokkusurumise test

Pakendi kokkusurumise test Loe edasi "

Package Compression Test The package compression test is a vital method used across packaging, pharmaceutical, and medical industries to evaluate the structural integrity of packaging materials. This test simulates real-world pressure conditions that packaging may encounter during transportation, stacking, or handling. It ensures that packaging does not rupture, deform, or fail under load—helping protect contents

Naatriumkloriidi ampulli jõu katsetamise juhend ISO 9187-1 nõuetele vastavuse saavutamiseks

Naatriumkloriidi ampulli jõu katsetamise juhend ISO 9187-1 nõuetele vastavuse saavutamiseks Loe edasi "

Introduction to Sodium Chloride Ampoules Sodium chloride ampoule is a widely used packaging format in the pharmaceutical industry, commonly serving injectable solutions for clinical and hospital use. These ampoules must meet strict safety and quality standards to ensure sterile conditions and break integrity. One of the essential performance indicators is the breaking force, which determines

Ampulli mehaanilise tugevuse tester vastavalt ISO 9187-le

Ampulli mehaanilise tugevuse tester vastavalt ISO 9187-le Loe edasi "

Introduction Accurate evaluation of ampoule mechanical strength tester is critical in pharmaceutical quality control. Glass ampoules used for injectable solutions must be strong enough to maintain sterility during transportation and storage, yet easy enough to break open without excessive force. ISO 9187 provides standardized test procedures to assess these qualities, especially breaking force measurement for

Pakendi terviklikkuse maksimeerimine pakendi survetugevuse testeriga

Pakendi terviklikkuse maksimeerimine pakendi survetugevuse testeriga Loe edasi "

Maximizing Package Integrity with Packaging Compression Strength Tester In today’s fast-paced logistics and pharmaceutical supply chains, packaging compression strength tester solutions are indispensable for safeguarding product quality and consumer safety. At Cell Instruments, we understand the significance of maintaining packaging integrity under real-world stress. This article provides a professional yet accessible overview of compression testing,

Plastist infusioonipudeli kokkusurumise katse ja komposiitkilekoti pakendi jõudluse analüüs

Plastist infusioonipudeli kokkusurumise katse ja komposiitkilekoti pakendi jõudluse analüüs Loe edasi "

Plastic Infusion Bottle Compression Test In the pharmaceutical and medical packaging industry, ensuring that packaging materials withstand external forces is crucial. The plastic infusion bottle compression test is an essential method to evaluate the strength and durability of plastic bottles used for infusion therapies. This article explores the significance of this test, highlighting related concepts

Break Loose and Glide Force Testing for Paper: ISO 7886 & Syringe Evaluation

Break Loose and Glide Force Testing for Paper: ISO 7886 & Syringe Evaluation Loe edasi "

Break Loose and Glide Force Testing: A Key Indicator of Syringe Performance In the pharmaceutical and medical device industries, break loose and glide force testing is a critical procedure used to evaluate the usability and quality of syringes. These tests determine how much force is required to start (break loose) and continue (glide) the movement

MST-01 libisemisjõu tester

MST-01 libisemisjõu tester Loe edasi "

Download Catalog In the quality assurance of medical syringes, glide force testing plays a pivotal role in assessing the smoothness and reliability of piston movement. It directly impacts user safety, comfort, and product compliance with critical international standards. This article explores the essentials of glide force testing, including related parameters like break loose force, and

ISO 7864 süstla funktsionaalsuse testimine hüpodermilise süstlaga

ISO 7864 süstla funktsionaalsuse testimine hüpodermilise süstlaga Loe edasi "

ISO 7864 Hypodermic Syringe Functionality Testing When it comes to sterile hypodermic needles, patient safety and product performance are non-negotiable. That’s where ISO 7864 plays a vital role. This international standard outlines comprehensive requirements and test methods to evaluate hypodermic needles for single-use syringes, including syringe functionality testing, needle penetration test method, and strength of