{"id":2139,"date":"2025-06-03T08:40:20","date_gmt":"2025-06-03T08:40:20","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2139"},"modified":"2026-01-13T07:49:16","modified_gmt":"2026-01-13T07:49:16","slug":"hypodermic-needle-sharpness-testing","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/tr\/hypodermic-needle-sharpness-testing\/","title":{"rendered":"Hipodermik \u0130\u011fne Keskinlik Testi"},"content":{"rendered":"<h1 class=\"wp-block-heading has-text-align-center\">ISO 7864 Hipodermik \u0130\u011fne Keskinlik Testi<\/h1>\n\n\n\n<div class=\"wp-block-stackable-columns stk-block-columns stk-block stk-3e28f64\" data-block-id=\"3e28f64\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-3e28f64-column\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-52adcfa\" data-v=\"4\" data-block-id=\"52adcfa\"><style>@media screen and (min-width:768px){.stk-52adcfa{flex:1 1 calc(70.6% - var(--stk-column-gap,0px) * 1 \/ 2 ) !important}}<\/style><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-52adcfa-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-52adcfa-inner-blocks\">\n<h2 class=\"wp-block-heading\">Giri\u015f<\/h2>\n\n\n\n<p><strong>\u0130\u011fne keskinli\u011fi testi<\/strong> hipodermik i\u011fnelerin de\u011ferlendirilmesi, t\u0131bbi kullan\u0131m s\u0131ras\u0131nda g\u00fcvenlik ve performans standartlar\u0131n\u0131 kar\u015f\u0131lamalar\u0131n\u0131n sa\u011flanmas\u0131 i\u00e7in gereklidir. Taraf\u0131ndan y\u00f6nlendirilen <strong>ISO 7864<\/strong>Bu test, uyumlulu\u011fu do\u011frulamak ve enjeksiyon s\u0131ras\u0131nda gereksiz a\u011fr\u0131 veya doku hasar\u0131n\u0131 \u00f6nlemek i\u00e7in kritik i\u011fne parametrelerini de\u011ferlendirir. Bu makalede, kapsaml\u0131 bir i\u011fne testinin nas\u0131l yap\u0131laca\u011f\u0131n\u0131 tart\u0131\u015faca\u011f\u0131z. <strong>i\u011fne keskinlik testi<\/strong> i\u00e7in en iyi uygulamalar da dahil olmak \u00fczere prosed\u00fcr <strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/tr\/syringe-needle-penetration-test\/\" target=\"_blank\" rel=\"noreferrer noopener\">penetrasyon i\u011fne testi<\/a><\/strong> ve <strong>hipodermik i\u011fne testi<\/strong> ISO 7864 gerekliliklerini kar\u015f\u0131lamak i\u00e7in.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u0130\u011fne Keskinlik Testinin \u00d6nemini Anlamak<\/h2>\n\n\n\n<p>Keskin i\u011fneler t\u0131bbi uygulamalarda minimum rahats\u0131zl\u0131k, daha az doku hasar\u0131 ve etkili ila\u00e7 da\u011f\u0131t\u0131m\u0131 sa\u011flamak i\u00e7in hayati \u00f6nem ta\u015f\u0131r. <strong>\u0130\u011fne keskinli\u011fi testi<\/strong> bir i\u011fnenin \u00e7e\u015fitli alt tabakalara minimum kuvvetle n\u00fcfuz etme kabiliyetini de\u011ferlendirerek hem tepe penetrasyon hem de s\u00fcr\u00fckleme kuvvetlerini \u00f6l\u00e7er. \u00dcreticiler ISO 7864 ile uyumlulu\u011fu sa\u011flayarak g\u00fcvenli ve g\u00fcvenilir t\u0131bbi cihazlar sunabilir, hasta konforu ve g\u00fcvenli\u011finin korunmas\u0131na yard\u0131mc\u0131 olabilir.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-070da0f\" data-v=\"4\" data-block-id=\"070da0f\"><style>@media screen and (min-width:768px){.stk-070da0f{flex:1 1 calc(29.4% - var(--stk-column-gap,0px) * 1 \/ 2 ) !important}}<\/style><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-070da0f-container stk--no-background stk--no-padding\"><div class=\"has-text-align-center stk-block-content stk-inner-blocks stk-070da0f-inner-blocks\">\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"519\" height=\"924\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/Hypodermic-Needle-Sharpness-Testing-ISO-7864.webp\" alt=\"\" class=\"wp-image-2141\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/Hypodermic-Needle-Sharpness-Testing-ISO-7864.webp 519w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/Hypodermic-Needle-Sharpness-Testing-ISO-7864-169x300.webp 169w\" sizes=\"(max-width: 519px) 100vw, 519px\" \/><\/figure>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u0130\u011fne Keskinli\u011fi Testi i\u00e7in ISO 7864'\u00fcn Temel Unsurlar\u0131<\/h2>\n\n\n\n<p><strong>ISO 7864<\/strong> i\u00e7in gereklilikleri ve test y\u00f6ntemlerini belirler. <strong>tek kullan\u0131ml\u0131k hipodermik i\u011fneler<\/strong>hassas i\u011fne performans\u0131na odaklanmaktad\u0131r. \u00d6zellikle, ISO 7864 Ek D a\u015fa\u011f\u0131dakileri ana hatlar\u0131yla belirtir <strong>penetrasyon i\u011fne testi<\/strong> \u00f6l\u00e7en metodoloji <strong>tepe penetrasyon kuvveti<\/strong> ve <strong>s\u00fcr\u00fckleme kuvveti<\/strong> Kontroll\u00fc bir alt tabakaya yerle\u015ftirme s\u0131ras\u0131nda.<\/p>\n\n\n\n<p>ISO 7864 y\u00f6ntemi, testlerde tutarl\u0131l\u0131k ve tekrarlanabilirlik sa\u011flayarak \u00fcreticilere \u00fcr\u00fcn kalitesi ve g\u00fcvenli\u011fi konusunda g\u00fcven verir.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Penetrasyon \u0130\u011fne Testi ve Hipodermik \u0130\u011fne Testi<\/h2>\n\n\n\n<p>Bu <strong>penetrasyon i\u011fne testi<\/strong> temel bir par\u00e7as\u0131d\u0131r. <strong>hipodermik i\u011fne testi<\/strong>. A\u015fa\u011f\u0131daki bile\u015fenleri ve ad\u0131mlar\u0131 i\u00e7erir:<\/p>\n\n\n\n<p><strong>1. Kuvvet \u00d6l\u00e7\u00fcm Aparat\u0131<\/strong><br>Bir y\u00fck h\u00fccresi ile donat\u0131lm\u0131\u015f bir kuvvet \u00f6l\u00e7er, test s\u0131ras\u0131nda i\u011fneye etki eden kuvvetleri kaydeder. Cihaz ayr\u0131ca i\u011fneyi g\u00fcvenli bir \u015fekilde tutar ve hareket ettirir. <strong>standart test h\u0131z\u0131 100 mm\/dak<\/strong> do\u011fru \u00f6l\u00e7\u00fcm i\u00e7in.<\/p>\n\n\n\n<p><strong>2. Substrat Se\u00e7imi<\/strong><br>Farkl\u0131 substratlar insan dokusunu sim\u00fcle eder ve g\u00fcvenilir bir test ortam\u0131 sa\u011flar. Yayg\u0131n substratlar \u015funlar\u0131 i\u00e7erir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Do\u011fal lateks kau\u00e7uk (40 \u00b1 5 Shore A)<\/li>\n\n\n\n<li>Poli\u00fcretan (85 \u00b1 10 Shore A)<\/li>\n\n\n\n<li>Silikon kau\u00e7uk (50 \u00b1 5 Shore A)<\/li>\n\n\n\n<li>Polietilen LDPE film (50 \u00b1 5 mikron)<\/li>\n<\/ul>\n\n\n\n<p>Tutarl\u0131 sonu\u00e7lar elde etmek i\u00e7in se\u00e7ilen substrat do\u011frulanmal\u0131d\u0131r.<\/p>\n\n\n\n<p><strong>3. Substrat Tutucu<\/strong><br>Paralel plakalara sahip iyi tasarlanm\u0131\u015f bir alt tabaka tutucu, alt tabakay\u0131 g\u00fcvenli bir \u015fekilde yerine s\u0131k\u0131\u015ft\u0131r\u0131r. Bu <strong>dairesel a\u00e7\u0131k penetrasyon alan\u0131 (nominal \u00e7ap: 10 mm)<\/strong> hassas testler yap\u0131lmas\u0131n\u0131 ve do\u011fru veri toplanmas\u0131n\u0131 sa\u011flar.<\/p>\n\n\n\n<p><strong>4. Penetrasyon Derinli\u011fi<\/strong><br>\u0130\u011fne \u015fu derinli\u011fe kadar sokulur <strong>Nominal uzunlu\u011funun 80%'si<\/strong> (\u00f6rne\u011fin, 5 mm'lik bir i\u011fne i\u00e7in 4 mm). Her testten sonra, yanl\u0131l\u0131\u011f\u0131 \u00f6nlemek i\u00e7in yeni bir substrat alan\u0131 kullan\u0131lmal\u0131d\u0131r.<\/p>\n\n\n\n<p><strong>5. Test Ortam\u0131<\/strong><br>Testler, de\u011fi\u015fkenli\u011fi \u00f6nlemek i\u00e7in kontroll\u00fc bir ortamda (18-28 \u00b0C; 25-75% RH) yap\u0131lmal\u0131d\u0131r.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u0130\u011fne Keskinlik Testinin Ger\u00e7ekle\u015ftirilmesi<\/h2>\n\n\n\n<p>Kapsaml\u0131 bir inceleme yapmak i\u00e7in <strong>i\u011fne keskinlik testi<\/strong>a\u015fa\u011f\u0131daki ad\u0131mlar\u0131 izleyin:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Test numunelerini ve substrat\u0131 haz\u0131rlay\u0131n<\/strong>standart ortam laboratuvar\u0131 ko\u015fullar\u0131nda en az 24 saat boyunca \u015fartland\u0131r\u0131n.<\/li>\n\n\n\n<li><strong>\u0130\u011fneyi monte edin<\/strong> kuvvet \u00f6l\u00e7\u00fcm cihaz\u0131na yerle\u015ftirin.<\/li>\n\n\n\n<li><strong>Alt tabakay\u0131 sabitleyin<\/strong> tutucuda, penetrasyon hedef alan\u0131 ile hizalanmas\u0131n\u0131 sa\u011flayarak.<\/li>\n\n\n\n<li><strong>S\u0131zma testini ba\u015flat\u0131n<\/strong> \u0130stenen penetrasyon derinli\u011fine ula\u015f\u0131lana kadar i\u011fneyi 100 mm\/dak h\u0131zla hareket ettirerek.<\/li>\n\n\n\n<li><strong>\u0130\u011fneyi geri \u00e7ekin<\/strong> ve t\u00fcm kuvvet profilini kaydedin.<\/li>\n<\/ul>\n\n\n\n<p>Yanl\u0131\u015f hizalama i\u011fnenin substrat tutucu ile \u00e7arp\u0131\u015fmas\u0131na neden olursa, testi at\u0131n ve d\u00fczg\u00fcn hizalanm\u0131\u015f bir numune ile yeniden yap\u0131n.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Veri Toplama ve Analiz<\/h2>\n\n\n\n<p>Bu <strong>kuvvet profili<\/strong> Test s\u0131ras\u0131nda olu\u015fturulan iki ana parametreyi yakalar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Tepe Penetrasyon Kuvveti<\/strong>: Alt tabakay\u0131 delmek i\u00e7in gereken en y\u00fcksek kuvvet.<\/li>\n\n\n\n<li><strong>S\u00fcr\u00fckleme Kuvveti<\/strong>: \u0130\u011fne alt tabakadan ge\u00e7erken \u00fczerine etki eden ortalama s\u00fcrt\u00fcnme kuvveti.<\/li>\n<\/ul>\n\n\n\n<p>Hesaplama <strong>ortalama ve standart sapma<\/strong> bu parametrelerin do\u011fru raporlanmas\u0131n\u0131 sa\u011flar. ISO 7864, test verilerini do\u011frulamak i\u00e7in istatistiksel olarak anlaml\u0131 \u00f6rneklem b\u00fcy\u00fckl\u00fcklerinin kullan\u0131lmas\u0131n\u0131 \u00f6nermektedir.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u0130\u011fne Keskinli\u011fi Test Sonu\u00e7lar\u0131n\u0131n Raporlanmas\u0131<\/h2>\n\n\n\n<p>Eksiksiz bir <strong>i\u011fne keskinlik testi<\/strong> rapor \u015funlar\u0131 i\u00e7ermelidir:<br>\u2705 Ortalama ve standart sapma <strong>tepe penetrasyon kuvveti<\/strong><br>\u2705 Ortalama ve standart sapma <strong>s\u00fcr\u00fckleme kuvveti<\/strong><br>\u2705 Test ortam\u0131n\u0131n ve kullan\u0131lan alt tabakalar\u0131n tan\u0131m\u0131<br>\u2705 ISO 7864 ile uyumlulu\u011fun teyidi<\/p>\n\n\n\n<p>Bu t\u00fcr kapsaml\u0131 raporlama, test s\u00fcrecinizde \u015feffafl\u0131k ve g\u00fcvenilirlik sa\u011flar.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>\u0130\u011fne Keskinlik Testi i\u00e7in Neden Cell Instruments'\u0131 Se\u00e7melisiniz?<\/strong><br>At <strong>H\u00fccre Enstr\u00fcmanlar\u0131<\/strong>i\u00e7in ekipman da dahil olmak \u00fczere geli\u015fmi\u015f malzeme test cihazlar\u0131 \u00fcretimi ve tedariki konusunda uzman\u0131z. <strong>i\u011fne keskinlik testi<\/strong>. G\u00fcvenilir test \u00e7\u00f6z\u00fcmlerimiz, \u00fcreticilerin ISO 7864 gerekliliklerini kar\u015f\u0131lamas\u0131na ve \u00fcr\u00fcn g\u00fcvenli\u011fi ile hasta konforunu sa\u011flamas\u0131na yard\u0131mc\u0131 olur. Ayr\u0131ca medikal, farmas\u00f6tik ve kalite kontrol gibi sekt\u00f6rleri destekleyerek benzersiz ihtiya\u00e7lar\u0131n\u0131za uygun \u00f6zelle\u015ftirilmi\u015f test ve otomasyon \u00e7\u00f6z\u00fcmleri sunuyoruz.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>\u0130\u011fne keskinli\u011fi testi<\/strong> t\u0131bbi i\u011fnelerin uluslararas\u0131 g\u00fcvenlik ve performans standartlar\u0131n\u0131 kar\u015f\u0131lamas\u0131n\u0131 sa\u011flamada vazge\u00e7ilmez bir ad\u0131md\u0131r. \u00dcreticiler ISO 7864'\u00fcn a\u00e7\u0131k y\u00f6nergelerini takip ederek ve hassas test ekipmanlar\u0131 kullanarak hipodermik i\u011fnelerinin en y\u00fcksek kalite ve g\u00fcvenilirlik standartlar\u0131n\u0131 kar\u015f\u0131lamas\u0131n\u0131 sa\u011flayabilir. \u0130leti\u015fim <strong>H\u00fccre Enstr\u00fcmanlar\u0131<\/strong> test ihtiya\u00e7lar\u0131n\u0131z\u0131 nas\u0131l destekleyebilece\u011fimizi \u00f6\u011frenmek i\u00e7in bug\u00fcn!<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>\u0130\u011fne Keskinlik Testi hakk\u0131nda SSS<\/strong><\/p>\n\n\n\n<p><strong>S1: \u0130\u011fne keskinli\u011fi testinin amac\u0131 nedir?<\/strong><br>A1: Minimum a\u011fr\u0131 ve doku hasar\u0131 sa\u011flamak i\u00e7in bir i\u011fnenin yerle\u015ftirme ve s\u00fcr\u00fckleme kuvvetlerini de\u011ferlendirerek hasta konforunu art\u0131r\u0131r.<\/p>\n\n\n\n<p><strong>S2: Hangi standartlar i\u011fne keskinli\u011fi testini d\u00fczenler?<\/strong><br>A2: <a href=\"https:\/\/www.iso.org\/standard\/60481.html\" target=\"_blank\" rel=\"noreferrer noopener\">ISO 7864<\/a> hipodermik i\u011fne testi i\u00e7in gerekli prosed\u00fcrleri ve performans kriterlerini ana hatlar\u0131yla belirtir.<\/p>\n\n\n\n<p><strong>S3: Test i\u00e7in hangi substratlar kullan\u0131l\u0131yor?<\/strong><br>A3: Yayg\u0131n substratlar aras\u0131nda do\u011fal lateks kau\u00e7uk, poli\u00fcretan, silikon kau\u00e7uk ve LDPE filmler bulunur.<\/p>\n\n\n\n<p><strong>S4: \u0130\u011fne keskinli\u011fi testinde s\u00fcr\u00fckleme kuvveti nas\u0131l hesaplan\u0131r?<\/strong><br>A4: Kuvvet profili \u00fczerindeki penetrasyon derinli\u011fi b\u00f6lgesinin 80%'sinden ortalama s\u00fcrt\u00fcnme kuvveti hesaplanarak belirlenir.<\/p>\n\n\n\n<p><strong>S5: Cell Instruments \u00f6zel i\u011fne keskinli\u011fi test \u00e7\u00f6z\u00fcmleri sa\u011flayabilir mi?<\/strong><br>A5: Evet, \u00f6zel \u00fcr\u00fcn test ihtiya\u00e7lar\u0131n\u0131z\u0131 kar\u015f\u0131lamak i\u00e7in size \u00f6zel test ekipman\u0131 ve otomasyon \u00e7\u00f6z\u00fcmleri sunuyoruz.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>ISO 7864 Hipodermik \u0130\u011fne Keskinlik Testi \u0130\u011fne Keskinlik Testi i\u00e7in ISO 7864'\u00fcn Temel Unsurlar\u0131 ISO 7864, hassas i\u011fne performans\u0131na odaklanarak tek kullan\u0131ml\u0131k hipodermik i\u011fneler i\u00e7in gereklilikleri ve test y\u00f6ntemlerini belirler. \u00d6zellikle, ISO 7864 Ek D, hem tepe penetrasyon kuvvetini hem de s\u00fcr\u00fcklemeyi \u00f6l\u00e7en penetrasyon i\u011fnesi test metodolojisini ana hatlar\u0131yla [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2139","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/tr\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 7864 Hypodermic Needle Sharpness Testing Key Elements of ISO 7864 for Needle Sharpness Testing ISO 7864 sets out the requirements and test methods for hypodermic needles for single use, focusing on precise needle performance. Specifically, Annex D of ISO 7864 outlines the penetration needle test methodology, which measures both peak penetration force and drag&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/posts\/2139","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/comments?post=2139"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/posts\/2139\/revisions"}],"predecessor-version":[{"id":2502,"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/posts\/2139\/revisions\/2502"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/media?parent=2139"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/categories?post=2139"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/tr\/wp-json\/wp\/v2\/tags?post=2139"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}