{"id":2105,"date":"2025-05-07T06:56:33","date_gmt":"2025-05-07T06:56:33","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2105"},"modified":"2025-05-07T06:56:34","modified_gmt":"2025-05-07T06:56:34","slug":"lla-collar-torque-resistance","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/th\/lla-collar-torque-resistance\/","title":{"rendered":"LLA Collar Torque Resistance"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2105\" class=\"elementor elementor-2105\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f46df2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f46df2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2444a elementor-widget elementor-widget-heading\" data-id=\"7b2444a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">LLA Collar Torque Resistance<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edec19 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8edec19\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e4ea1f elementor-widget elementor-widget-heading\" data-id=\"0e4ea1f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Annex G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3053d41 e-flex e-con-boxed e-con e-parent\" data-id=\"3053d41\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d4d20a elementor-widget elementor-widget-text-editor\" data-id=\"7d4d20a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"376\" data-end=\"978\">In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is <strong data-start=\"567\" data-end=\"599\">LLA collar torque resistance<\/strong>, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar can withstand the rotational force when medical personnel attach needle hubs or compatible connectors. Conducting this test in accordance with <em data-start=\"862\" data-end=\"875\">ISO 11040-4<\/em> and <em data-start=\"880\" data-end=\"890\">Annex G4<\/em> helps manufacturers meet regulatory compliance and deliver safe, functional products.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0043965 elementor-widget elementor-widget-heading\" data-id=\"0043965\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">LLA Collar Torque Resistance and It Matters<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef59016 elementor-widget elementor-widget-text-editor\" data-id=\"ef59016\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"985\" data-end=\"1456\"><strong data-start=\"1047\" data-end=\"1079\">LLA collar torque resistance<\/strong> refers to the capacity of the Luer lock adaptor collar on a syringe to resist turning or loosening when torque is applied. In real-world use, this simulates the mechanical stress exerted when a clinician connects a Luer-lock-compatible device. Failure in torque resistance can lead to leakage, improper drug administration, or contamination\u2014serious risks in clinical settings.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77afa8a elementor-widget elementor-widget-heading\" data-id=\"77afa8a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Syringe Testing Standard - ISO 11040-4 Annex G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f4cc74 e-con-full e-flex e-con e-child\" data-id=\"9f4cc74\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0879ad7 elementor-widget elementor-widget-text-editor\" data-id=\"0879ad7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1463\" data-end=\"1902\">The <strong data-start=\"1525\" data-end=\"1540\">ISO 11040-4<\/strong> standard, titled <em data-start=\"1558\" data-end=\"1673\">Prefilled syringes \u2014 Part 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling<\/em>, outlines rigorous test methods to ensure product reliability. <em data-start=\"1737\" data-end=\"1747\">Annex G4<\/em> specifically details the method for assessing <strong data-start=\"1794\" data-end=\"1826\">LLA collar torque resistance<\/strong>, making it indispensable for manufacturers involved in <strong data-start=\"1882\" data-end=\"1901\">syringe testing<\/strong>.<\/p><p class=\"\" data-start=\"1904\" data-end=\"1941\">Key highlights from Annex G4 include:<\/p><ul><li data-start=\"1944\" data-end=\"2066\"><strong data-start=\"1944\" data-end=\"1963\">Test Principle:<\/strong> Verifies if the LLA collar can withstand torque during attachment of a standard 6% Luer taper fitting.<\/li><li data-start=\"2069\" data-end=\"2129\"><strong data-start=\"2069\" data-end=\"2099\">Recommended Sampling Rate:<\/strong> 500 Hz for peak measurements.<\/li><li data-start=\"2132\" data-end=\"2186\"><strong data-start=\"2132\" data-end=\"2160\">Standard Rotation Speed:<\/strong> 20 rpm or as agreed upon.<\/li><li data-start=\"2189\" data-end=\"2255\"><strong data-start=\"2189\" data-end=\"2212\">Measurement Output:<\/strong> Peak torque at collar movement initiation.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1ed627 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"d1ed627\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"236\" height=\"361\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp\" class=\"attachment-full size-full wp-image-2107\" alt=\"LLA Collar Torque Resistance - ISO 11040-4 Syringe Testing\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp 236w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing-196x300.webp 196w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47df98e elementor-widget elementor-widget-heading\" data-id=\"47df98e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test Equipment for LLA Collar Torque Resistance<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4baaf8e elementor-widget elementor-widget-text-editor\" data-id=\"4baaf8e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2262\" data-end=\"2400\">Performing the test requires precision instrumentation. The standard setup includes:<\/p><ul><li data-start=\"2403\" data-end=\"2556\"><strong data-start=\"2403\" data-end=\"2441\">Torque Tester with Rotation Device<\/strong>: Should be capable of detecting peak torque with a resolution of <strong data-start=\"2507\" data-end=\"2519\">0.05 Ncm<\/strong>, ideal range being <strong data-start=\"2539\" data-end=\"2555\">up to 35 Ncm<\/strong>.<\/li><li data-start=\"2559\" data-end=\"2630\"><strong data-start=\"2559\" data-end=\"2581\">LLA Collar Gripper<\/strong>: Securely clamps the collar without damaging it.<\/li><li data-start=\"2633\" data-end=\"2737\"><strong data-start=\"2633\" data-end=\"2661\">Rotatable Syringe Holder<\/strong>: Allows for accurate and consistent rotation of the syringe or the closure.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0058def elementor-widget elementor-widget-heading\" data-id=\"0058def\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Step-by-Step Guide to Conduct the Test<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e82ef56 elementor-widget elementor-widget-text-editor\" data-id=\"e82ef56\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2938\" data-end=\"3119\">Professionals in quality control can follow these steps to ensure accurate and standardized testing of <strong data-start=\"3086\" data-end=\"3118\">LLA collar torque resistance<\/strong>:<\/p><ol><li data-start=\"3124\" data-end=\"3195\"><strong data-start=\"3124\" data-end=\"3134\">Insert<\/strong> the sterilized subassembled syringe into the syringe holder.<\/li><li data-start=\"3199\" data-end=\"3231\"><strong data-start=\"3199\" data-end=\"3209\">Remove<\/strong> the tip cap manually.<\/li><li data-start=\"3235\" data-end=\"3297\"><strong data-start=\"3235\" data-end=\"3244\">Mount<\/strong> the LLA collar gripper securely onto the LLA collar.<\/li><li data-start=\"3301\" data-end=\"3355\"><strong data-start=\"3301\" data-end=\"3309\">Zero<\/strong> the torque cell to eliminate pre-load torque.<\/li><li data-start=\"3359\" data-end=\"3416\"><strong data-start=\"3359\" data-end=\"3366\">Set<\/strong> the rotation speed to 20 rpm (or as appropriate).<\/li><li data-start=\"3420\" data-end=\"3509\"><strong data-start=\"3420\" data-end=\"3432\">Initiate<\/strong> the test by rotating the syringe or closure 90\u00b0 in the designated direction.<\/li><li data-start=\"3513\" data-end=\"3568\"><strong data-start=\"3513\" data-end=\"3523\">Record<\/strong> the peak torque when collar movement begins.<\/li><\/ol><p class=\"\" data-start=\"3570\" data-end=\"3675\">This torque value reflects the <strong data-start=\"3601\" data-end=\"3623\">maximum resistance<\/strong> offered by the LLA collar under operational stress.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d445bbc e-con-full e-flex e-con e-child\" data-id=\"d445bbc\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-defbeb6 e-con-full e-flex e-con e-child\" data-id=\"defbeb6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c54c92 elementor-widget elementor-widget-heading\" data-id=\"1c54c92\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test Reporting and Quality Control<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-669ef67 elementor-widget elementor-widget-text-editor\" data-id=\"669ef67\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3682\" data-end=\"3799\">According to ISO 11040-4 Annex G4, a comprehensive test report must include:<\/p><ul><li data-start=\"3802\" data-end=\"3826\">Peak torque values (Ncm)<\/li><li data-start=\"3829\" data-end=\"3849\">Rotation speed (rpm)<\/li><li data-start=\"3852\" data-end=\"3876\">Number of samples tested<\/li><li data-start=\"3879\" data-end=\"3896\">Pass\/fail results<\/li><li data-start=\"3899\" data-end=\"3931\">Notes on deviations or anomalies<\/li><\/ul><p class=\"\" data-start=\"3933\" data-end=\"4059\">This documentation ensures traceability and compliance, both critical for regulatory audits and product release certification.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb68c8a e-con-full e-flex e-con e-child\" data-id=\"cb68c8a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c067893 elementor-widget elementor-widget-heading\" data-id=\"c067893\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Advantages of Automated Torque Testing<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36ac35a elementor-widget elementor-widget-text-editor\" data-id=\"36ac35a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4066\" data-end=\"4277\">At Cell Instruments, we specialize in precision test systems, including torque testers tailored for <strong data-start=\"4211\" data-end=\"4243\">LLA collar torque resistance<\/strong> evaluations. Automation enhances:<\/p><ul><li data-start=\"4280\" data-end=\"4309\"><strong data-start=\"4280\" data-end=\"4309\">Measurement repeatability<\/strong><\/li><li data-start=\"4312\" data-end=\"4329\"><strong data-start=\"4312\" data-end=\"4329\">Data accuracy<\/strong><\/li><li data-start=\"4332\" data-end=\"4358\"><strong data-start=\"4332\" data-end=\"4358\">Operational efficiency<\/strong><\/li><li data-start=\"4361\" data-end=\"4385\"><strong data-start=\"4361\" data-end=\"4385\">Compliance assurance<\/strong><\/li><\/ul><p class=\"\" data-start=\"4387\" data-end=\"4527\">Customized fixtures and software integration allow labs to streamline syringe testing workflows while conforming strictly to ISO guidelines.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11ccf92 elementor-widget elementor-widget-text-editor\" data-id=\"11ccf92\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4984\" data-end=\"5514\">Understanding and implementing the <strong data-start=\"5036\" data-end=\"5068\">LLA collar torque resistance<\/strong> test in alignment with <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5092\" data-end=\"5107\">ISO 11040-4<\/strong><\/a> and <strong data-start=\"5112\" data-end=\"5124\">Annex G4<\/strong> is vital for syringe quality assurance. This test safeguards against mechanical failure during clinical use and helps manufacturers uphold the highest standards of patient safety. At <strong data-start=\"5308\" data-end=\"5328\">Cell Instruments<\/strong>, we provide state-of-the-art torque testing solutions that align with global standards and industry needs, empowering syringe manufacturers with reliable data and regulatory confidence.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2105","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/th\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/posts\/2105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/comments?post=2105"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/posts\/2105\/revisions"}],"predecessor-version":[{"id":2111,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/posts\/2105\/revisions\/2111"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/media?parent=2105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/categories?post=2105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/tags?post=2105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}