{"id":1994,"date":"2025-04-02T06:13:33","date_gmt":"2025-04-02T06:13:33","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=1994"},"modified":"2025-04-02T06:30:46","modified_gmt":"2025-04-02T06:30:46","slug":"syringes-needle-penetration-test-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/th\/syringes-needle-penetration-test-iso-11040-4\/","title":{"rendered":"Syringes Needle Penetration Test ISO 11040-4 Annex F"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"1994\" class=\"elementor elementor-1994\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d8f0949 e-flex e-con-boxed e-con e-parent\" data-id=\"d8f0949\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af89456 elementor-widget elementor-widget-heading\" data-id=\"af89456\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Needle Penetration Testing<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75ecf40 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"75ecf40\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20ce2df elementor-widget elementor-widget-heading\" data-id=\"20ce2df\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Annex F<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c9ca423 e-flex e-con-boxed e-con e-parent\" data-id=\"c9ca423\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-41f75ef e-con-full e-flex e-con e-child\" data-id=\"41f75ef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5114c7b elementor-widget elementor-widget-text-editor\" data-id=\"5114c7b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>The <strong>syringes needle penetration test<\/strong> is a crucial procedure in the medical device industry, ensuring the sharpness and effectiveness of needles used in medical applications. This test evaluates the <strong>needle penetration force<\/strong> required to pierce a test foil, reflecting the ease with which a needle can penetrate human skin or other materials.<\/p><p>To guarantee patient safety and product reliability, international standards like <strong>ISO 11040-4<\/strong> outline precise testing methodologies for syringe needles. These standards help manufacturers maintain quality control and regulatory compliance.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c4a1c1 elementor-widget elementor-widget-heading\" data-id=\"1c4a1c1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Needle Penetration Test Equipment Required<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-405b6c1 elementor-widget elementor-widget-text-editor\" data-id=\"405b6c1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 3 []\">According to <strong>ISO 11040-4<\/strong>, the following apparatus is essential for conducting a <a href=\"https:\/\/www.pharmacopoeiatest.com\/th\/syringe-needle-penetration-test\/\" target=\"_blank\" rel=\"noopener\"><strong>needle penetration test<\/strong><\/a>:<\/p><ul><li data-pm-slice=\"1 3 []\"><strong>Universal tensile and compression testing machine<\/strong> with a measurement range of up to 10 N (or as required) and a test speed between 20 mm\/min and 200 mm\/min.<\/li><li data-pm-slice=\"1 3 []\"><strong>Needle holder<\/strong> to secure the needle during testing.<\/li><li data-pm-slice=\"1 3 []\"><strong>Test foil<\/strong>, with specifications agreed upon by manufacturers and clients.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3315f97 elementor-widget elementor-widget-image\" data-id=\"3315f97\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/th\/syringe-needle-penetration-test\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/elementor\/thumbs\/ISO-11040-4-syringes-needle-penetration-test-equipment-r3r52op9pahd5s2kzyk3xzbhif0hy69cozbct55ytk.webp\" title=\"ISO 11040-4 syringes needle penetration test equipment\" alt=\"ISO 11040-4 syringes needle penetration test equipment\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff15e94 elementor-widget elementor-widget-heading\" data-id=\"ff15e94\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Syringes Needle Penetration Test Method Procedure<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe76308 elementor-widget elementor-widget-text-editor\" data-id=\"fe76308\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ol><li>Secure the test foil in a tension-free holder.<\/li><li>Fix the needle perpendicularly in the holder, aligning its tip to the geometric center of the test foil.<\/li><li>Initiate the test and allow the needle to penetrate the foil at a controlled speed.<\/li><li>Record the force-displacement curve to analyze penetration characteristics.<\/li><li>Repeat the test with a fresh section of foil for each measurement.<\/li><\/ol><p>Higher sampling rates, such as 500 Hz, enhance measurement accuracy when recording peak force values.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ebd0c elementor-widget elementor-widget-heading\" data-id=\"60ebd0c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Key Needle Penetration Force Parameters in Testing\u200b<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f1cf32 elementor-widget elementor-widget-text-editor\" data-id=\"0f1cf32\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 1 []\">The force exerted during penetration is categorized into different stages:<\/p><ul data-spread=\"false\"><li><strong>Piercing force (F<sub>0<\/sub>):<\/strong> The force required to pass the needle tip through the foil.<\/li><li><strong>Cutting force (F<sub>1<\/sub>):<\/strong> The force used by the cutting edges.<\/li><li><strong>Heel force (F<sub>2<\/sub>):<\/strong> The force exerted when the heel of the needle passes through.<\/li><li><strong>Drag penetration force (F<sub>3<\/sub>):<\/strong> The resistance force after full penetration.<\/li><\/ul><p>By evaluating these parameters, manufacturers can ensure that needles meet the required sharpness and usability standards.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84d059d elementor-widget elementor-widget-heading\" data-id=\"84d059d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Compliance with ISO 11040-4 for Quality Assurance<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a670d9 elementor-widget elementor-widget-text-editor\" data-id=\"7a670d9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 3 []\">ISO 11040-4 sets forth comprehensive guidelines for testing prefilled syringes, ensuring:<\/p><ul><li data-pm-slice=\"1 3 []\">Standardized <strong>needle penetration force<\/strong> measurement.<\/li><li data-pm-slice=\"1 3 []\">Consistency across different needle and syringe types.<\/li><li data-pm-slice=\"1 3 []\">Compliance with global medical safety requirements.<\/li><li data-pm-slice=\"1 3 []\">Reduction of risks associated with improper needle penetration.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e1f022 elementor-widget elementor-widget-heading\" data-id=\"5e1f022\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">NPT-01 Needle Penetration Test Equipment<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53d8fee elementor-widget elementor-widget-text-editor\" data-id=\"53d8fee\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 3 []\">The <strong>NPT-01 needle penetration test equipment<\/strong> is designed to meet <strong>ISO 11040-4<\/strong> compliance while offering precise testing solutions. It features:<\/p><ul><li data-pm-slice=\"1 3 []\"><strong>PLC control and 7-inch HMI touch screen<\/strong> for easy operation.<\/li><li data-pm-slice=\"1 3 []\"><strong>Stepper motor and precision ball screw<\/strong> ensuring consistent results.<\/li><li data-pm-slice=\"1 3 []\"><strong>Variable test speeds (1-500mm\/min)<\/strong> for flexible testing conditions.<\/li><li data-pm-slice=\"1 3 []\"><strong>Multiple sample holding jigs<\/strong> to accommodate various needle and syringe types.<\/li><li data-pm-slice=\"1 3 []\"><strong>Embedded microprinter and RS232 output<\/strong> for efficient data recording.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7e5035 elementor-widget elementor-widget-text-editor\" data-id=\"f7e5035\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 1 []\">The <strong>syringes needle penetration test<\/strong> is vital for ensuring needle sharpness, patient safety, and regulatory compliance. By following <strong>ISO 11040-4<\/strong> guidelines and using advanced testing equipment like the <strong>NPT-01<\/strong>, manufacturers can enhance product quality while meeting industry standards.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Needle Penetration Testing ISO 11040-4 Annex F The syringes needle penetration test is a crucial procedure in the medical device industry, ensuring the sharpness and effectiveness of needles used in medical applications. This test evaluates the needle penetration force required to pierce a test foil, reflecting the ease with which a needle can penetrate human [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-1994","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/th\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Needle Penetration Testing ISO 11040-4 Annex F The syringes needle penetration test is a crucial procedure in the medical device industry, ensuring the sharpness and effectiveness of needles used in medical applications. This test evaluates the needle penetration force required to pierce a test foil, reflecting the ease with which a needle can penetrate human&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/posts\/1994","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/comments?post=1994"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/posts\/1994\/revisions"}],"predecessor-version":[{"id":2009,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/posts\/1994\/revisions\/2009"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/media?parent=1994"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/categories?post=1994"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/th\/wp-json\/wp\/v2\/tags?post=1994"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}