{"id":2429,"date":"2025-11-06T07:49:46","date_gmt":"2025-11-06T07:49:46","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2429"},"modified":"2025-11-06T07:55:39","modified_gmt":"2025-11-06T07:55:39","slug":"iso-9626","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/sv\/iso-9626\/","title":{"rendered":"ISO 9626"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2429\" class=\"elementor elementor-2429\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5aa439d7 e-flex e-con-boxed e-con e-parent\" data-id=\"5aa439d7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-442ef7 elementor-widget elementor-widget-text-editor\" data-id=\"442ef7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><\/h2>\n<!-- \/wp:heading -->\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8d2ddaa e-flex e-con-boxed e-con e-parent\" data-id=\"8d2ddaa\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1da949 elementor-widget elementor-widget-heading\" data-id=\"a1da949\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 9626 <br><small><small>Test av n\u00e5lslangar av rostfritt st\u00e5l<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28c31c0 e-con-full e-flex e-con e-child\" data-id=\"28c31c0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b07c887 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"b07c887\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"463\" data-end=\"992\"><strong data-start=\"463\" data-end=\"475\">ISO 9626<\/strong> specificerar kraven och <strong data-start=\"507\" data-end=\"557\">provningsmetoder f\u00f6r n\u00e5lslangar av rostfritt st\u00e5l<\/strong> anv\u00e4nds vid tillverkning av medicintekniska produkter som hypodermiska n\u00e5lar och kanyler. Denna internationella standard s\u00e4kerst\u00e4ller att de slangar som anv\u00e4nds i medicinska applikationer uppfyller konsekventa prestanda- och s\u00e4kerhetskrav. Tv\u00e5 viktiga tester enligt ISO 9626 \u00e4r <strong data-start=\"814\" data-end=\"842\">styvhet hos slangprov<\/strong> och <strong data-start=\"851\" data-end=\"892\">slangens motst\u00e5ndskraft mot brottprov<\/strong>som \u00e4r n\u00f6dv\u00e4ndiga f\u00f6r att bed\u00f6ma den mekaniska integriteten och h\u00e5llbarheten hos r\u00f6r av rostfritt st\u00e5l.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34234b5 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"34234b5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/11\/ISO-9626---Stainless-Steel-Needle-Tubing-Stiffness-and-Break-Strength-Testing.webp\" class=\"attachment-full size-full wp-image-2435\" alt=\"ISO 9626 - Provning av styvhet och brotth\u00e5llfasthet f\u00f6r n\u00e5lr\u00f6r av rostfritt st\u00e5l\" srcset=\"\" sizes=\"(max-width: 600px) 100vw, 600px\" data-srcset=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0df13d1 elementor-widget elementor-widget-heading\" data-id=\"0df13d1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vad \u00e4r ISO 9626?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-185e4a4 elementor-widget elementor-widget-text-editor\" data-id=\"185e4a4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1422\">ISO 9626-standarden, fullst\u00e4ndig titel <em data-start=\"1346\" data-end=\"1450\">\"N\u00e5lslangar av rostfritt st\u00e5l f\u00f6r tillverkning av medicintekniska produkter - Krav och provningsmetoder\"<\/em>, g\u00e4ller f\u00f6r <strong data-start=\"1463\" data-end=\"1502\">Styv n\u00e5lslang av rostfritt st\u00e5l<\/strong> l\u00e4mplig f\u00f6r tillverkning av hypodermiska n\u00e5lar och andra komponenter f\u00f6r medicinsk utrustning.<\/p>\n<p data-start=\"1283\" data-end=\"1620\">ISO 9626 spelar en avg\u00f6rande roll f\u00f6r att s\u00e4kerst\u00e4lla att slangar av rostfritt st\u00e5l som anv\u00e4nds f\u00f6r medicinska n\u00e5lar har tillr\u00e4cklig <strong data-start=\"1393\" data-end=\"1416\">mekanisk styrka<\/strong>, <strong data-start=\"1418\" data-end=\"1433\">flexibilitet<\/strong>, och <strong data-start=\"1439\" data-end=\"1464\">motst\u00e5ndskraft mot utmattning<\/strong>. Slangar som inte uppfyller dessa krav kan leda till att n\u00e5len b\u00f6js eller g\u00e5r s\u00f6nder under anv\u00e4ndning, vilket utg\u00f6r en risk f\u00f6r patienter och v\u00e5rdpersonal.<\/p>\n<p data-start=\"1622\" data-end=\"1645\">Standarden definierar:<\/p>\n<ul>\n<li data-start=\"1648\" data-end=\"1705\"><strong data-start=\"1648\" data-end=\"1675\">Materialspecifikationer<\/strong> f\u00f6r r\u00f6r av rostfritt st\u00e5l.<\/li>\n<li data-start=\"1708\" data-end=\"1775\"><strong data-start=\"1708\" data-end=\"1734\">Dimensionella toleranser<\/strong> inklusive v\u00e4ggtjocklek och diameter.<\/li>\n<li data-start=\"1778\" data-end=\"1853\"><strong data-start=\"1778\" data-end=\"1807\">Tester av mekaniska egenskaper<\/strong>, s\u00e5som styvhet och brottmotst\u00e5nd.<\/li>\n<\/ul>\n<p data-start=\"1855\" data-end=\"1991\">Genom att f\u00f6lja ISO 9626 kan tillverkarna uppr\u00e4tth\u00e5lla en j\u00e4mn produktkvalitet och uppfylla internationella best\u00e4mmelser f\u00f6r medicintekniska produkter.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-304c484 elementor-widget elementor-widget-heading\" data-id=\"304c484\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Vid bed\u00f6mning av slangar till medicintekniska produkter \u00e4r tv\u00e5 aspekter av mekanisk prestanda s\u00e4rskilt viktiga:<\/p>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a08344a elementor-widget elementor-widget-heading\" data-id=\"a08344a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Test av r\u00f6rets styvhet<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8605095 elementor-widget elementor-widget-text-editor\" data-id=\"8605095\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2030\" data-end=\"2392\">Den <strong data-start=\"2034\" data-end=\"2062\">styvhet hos slangprov<\/strong> utv\u00e4rderar hur motst\u00e5ndskraftiga n\u00e5lslangar av rostfritt st\u00e5l \u00e4r mot deformation n\u00e4r en kraft appliceras. Enligt ISO 9626 Annex B inneb\u00e4r testet att en specificerad l\u00e4ngd av slangen st\u00f6ds i b\u00e5da \u00e4ndar och att en k\u00e4nd kraft appliceras p\u00e5 slangen. <strong data-start=\"2287\" data-end=\"2319\">ned\u00e5tg\u00e5ende kraft i dess centrum<\/strong>. Beloppet av <strong data-start=\"2335\" data-end=\"2349\">avb\u00f6jning<\/strong> m\u00e4ts sedan f\u00f6r att best\u00e4mma styvheten.<\/p>\n<p data-start=\"2394\" data-end=\"2540\">Detta test ger insikt i hur mycket slangen kommer att b\u00f6jas under belastning - en nyckelfaktor f\u00f6r att s\u00e4kerst\u00e4lla <strong data-start=\"2498\" data-end=\"2537\">n\u00e5lens stabilitet under inf\u00f6randet<\/strong>.<\/p>\n<h4 data-start=\"2542\" data-end=\"2567\">\u00d6versikt \u00f6ver proceduren<\/h4>\n<ol data-start=\"2568\" data-end=\"2856\">\n<li data-start=\"2568\" data-end=\"2669\">\n<p data-start=\"2571\" data-end=\"2669\">Slangen \u00e4r placerad p\u00e5 en <strong data-start=\"2597\" data-end=\"2628\">Testapparat f\u00f6r styvhet<\/strong> med en definierad sp\u00e4nnvidd baserad p\u00e5 dess storlek.<\/p>\n<\/li>\n<li data-start=\"2670\" data-end=\"2768\">\n<p data-start=\"2673\" data-end=\"2768\">A <strong data-start=\"2675\" data-end=\"2694\">lastkolv<\/strong> ut\u00f6var en ned\u00e5triktad kraft med en hastighet mellan <strong data-start=\"2739\" data-end=\"2765\">1 mm\/min och 10 mm\/min<\/strong>.<\/p>\n<\/li>\n<li data-start=\"2769\" data-end=\"2856\">\n<p data-start=\"2772\" data-end=\"2856\">Den <strong data-start=\"2776\" data-end=\"2790\">avb\u00f6jning<\/strong> vid lastningspunkten registreras till n\u00e4rmaste <strong data-start=\"2842\" data-end=\"2853\">0,01 mm<\/strong>.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"2858\" data-end=\"3058\">H\u00f6gre styvhet indikerar starkare slangar som st\u00e5r emot b\u00f6jning, medan l\u00e4gre styvhet kan tyda p\u00e5 \u00f6kad flexibilitet. B\u00e5da egenskaperna \u00e4r viktiga beroende p\u00e5 den avsedda medicinska till\u00e4mpningen.<\/p>\n<p data-start=\"3060\" data-end=\"3349\"><strong data-start=\"3060\" data-end=\"3098\">Cell Instruments styvhetsprovare<\/strong> erbjuder ett precisionsstyrt belastningssystem och digital m\u00e4tning av f\u00f6rskjutning, helt i enlighet med kraven i ISO 9626. Det g\u00f6r det m\u00f6jligt f\u00f6r laboratorier att utf\u00f6ra <strong data-start=\"3260\" data-end=\"3309\">styvhetsprov f\u00f6r n\u00e5lr\u00f6r av rostfritt st\u00e5l<\/strong> med h\u00f6g noggrannhet och repeterbarhet.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80ffe02 elementor-widget elementor-widget-heading\" data-id=\"80ffe02\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Slangens motst\u00e5ndskraft mot brott<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24288c0 elementor-widget elementor-widget-text-editor\" data-id=\"24288c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3396\" data-end=\"3665\">Den <strong data-start=\"3400\" data-end=\"3441\">slangens motst\u00e5ndskraft mot brottprov<\/strong> (ISO 9626 Annex C) utv\u00e4rderar slangens f\u00f6rm\u00e5ga att motst\u00e5 upprepad b\u00f6jning utan att spricka eller g\u00e5 s\u00f6nder. Detta simulerar verkliga f\u00f6rh\u00e5llanden d\u00e4r en n\u00e5l kan uts\u00e4ttas f\u00f6r cykliska p\u00e5frestningar under hantering eller anv\u00e4ndning.<\/p>\n<h4 data-start=\"3667\" data-end=\"3688\">Testprincip<\/h4>\n<p data-start=\"3689\" data-end=\"4019\">En \u00e4nde av slangen \u00e4r fast monterad och en <strong data-start=\"3735\" data-end=\"3761\">upprepad b\u00f6jkraft<\/strong> appliceras p\u00e5 ett specifikt avst\u00e5nd. Slangen b\u00f6js omv\u00e4xlande i motsatta riktningar genom en definierad vinkel - typiskt <strong data-start=\"3887\" data-end=\"3920\">25\u00b0 f\u00f6r normalv\u00e4ggiga slangar<\/strong>, <strong data-start=\"3922\" data-end=\"3945\">20\u00b0 f\u00f6r tunnv\u00e4ggiga<\/strong>, och <strong data-start=\"3951\" data-end=\"3987\">15\u00b0 f\u00f6r ultratunnv\u00e4ggiga slangar<\/strong> - f\u00f6r <strong data-start=\"3994\" data-end=\"4016\">20 kompletta cykler<\/strong>.<\/p>\n<p data-start=\"4021\" data-end=\"4096\">Efter provningen unders\u00f6ks slangen visuellt f\u00f6r att uppt\u00e4cka eventuella tecken p\u00e5 brott.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-54ef89d e-flex e-con-boxed e-con e-child\" data-id=\"54ef89d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d72668b elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"d72668b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong data-start=\"4098\" data-end=\"4143\">Cell Instruments' <a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/medical-needle-break-resistance-tester\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">Tester f\u00f6r brottmotst\u00e5nd<\/a><\/strong> har programmerbar cyklisk r\u00f6relsekontroll och ett exakt vinkelf\u00f6rskjutningssystem, vilket m\u00f6jligg\u00f6r noggrann utv\u00e4rdering av slangens <strong data-start=\"4276\" data-end=\"4298\">utmattningsh\u00e5llfasthet<\/strong> och <strong data-start=\"4303\" data-end=\"4317\">H\u00e5llbarhet<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d56cba elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"5d56cba\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/medical-needle-break-resistance-tester\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp\" class=\"attachment-large size-large wp-image-1924\" alt=\"Tester f\u00f6r motst\u00e5nd mot brytning av medicinska n\u00e5lar\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp 1000w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-768x768.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7bc2f44 elementor-widget elementor-widget-heading\" data-id=\"7bc2f44\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vanliga fr\u00e5gor<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7e535a elementor-widget elementor-widget-toggle\" data-id=\"d7e535a\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2261\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2261\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">F1: Vad \u00e4r ISO 9626?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2261\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2261\"><p data-start=\"5213\" data-end=\"5511\"><strong data-start=\"5241\" data-end=\"5247\">A:<\/strong> <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener\">ISO 9626<\/a> \u00e4r en internationell standard som specificerar krav och provningsmetoder f\u00f6r <strong data-start=\"5335\" data-end=\"5368\">n\u00e5lslang av rostfritt st\u00e5l<\/strong> som anv\u00e4nds vid tillverkning av medicintekniska produkter. Den definierar parametrar f\u00f6r dimensioner, styvhet, brottmotst\u00e5nd och \u00f6vergripande mekanisk prestanda.<\/p>\n<p data-start=\"5513\" data-end=\"5787\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2262\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2262\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">F2: Varf\u00f6r \u00e4r det viktigt att testa r\u00f6rets styvhet?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2262\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2262\"><p data-start=\"5513\" data-end=\"5787\"><strong data-start=\"5570\" data-end=\"5576\">A:<\/strong> Den <strong data-start=\"5581\" data-end=\"5609\">styvhet hos slangprov<\/strong> s\u00e4kerst\u00e4ller att slangen bibeh\u00e5ller tillr\u00e4cklig styvhet och inte b\u00f6js f\u00f6r mycket under belastning. Det \u00e4r avg\u00f6rande f\u00f6r de medicinska n\u00e5larnas stabilitet och precision vid ins\u00e4ttning.<\/p>\n<p data-start=\"5789\" data-end=\"6071\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2263\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2263\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">F3: Vad utv\u00e4rderar slangens motst\u00e5ndskraft mot brott?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2263\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2263\"><p data-start=\"5789\" data-end=\"6071\"><strong data-start=\"5861\" data-end=\"5867\">A:<\/strong> Detta test m\u00e4ter slangens f\u00f6rm\u00e5ga att motst\u00e5 <strong data-start=\"5921\" data-end=\"5948\">upprepade b\u00f6jningscykler<\/strong> utan sprickbildning. Det bidrar till att bekr\u00e4fta h\u00e5llbarheten och s\u00e4kerheten hos medicintekniska slangar av rostfritt st\u00e5l i kliniska till\u00e4mpningar.<\/p>\n<p data-start=\"6073\" data-end=\"6350\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2264\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2264\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q4: Vilken utrustning kan utf\u00f6ra ISO 9626-test?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2264\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2264\"><p data-start=\"6073\" data-end=\"6350\"><strong data-start=\"6129\" data-end=\"6135\">A:<\/strong> <strong data-start=\"6136\" data-end=\"6202\">Cell Instruments styvhetsprovare och brottmotst\u00e5ndsprovare<\/strong> \u00e4r speciellt utformade f\u00f6r att utf\u00f6ra ISO 9626-kompatibla tester och erbjuder exakt kraftkontroll, automatiserad m\u00e4tning och tillf\u00f6rlitlig repeterbarhet.<\/p>\n<p data-start=\"6352\" data-end=\"6632\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2265\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2265\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">F5: Vem ska utf\u00f6ra ISO 9626-tester?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2265\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2265\"><p data-start=\"6352\" data-end=\"6632\"><strong data-start=\"6397\" data-end=\"6403\">A:<\/strong> Ingenj\u00f6rer inom kvalitetskontroll, laboratorietekniker och tillverkare av medicinsk utrustning som producerar eller validerar <strong data-start=\"6512\" data-end=\"6545\">n\u00e5lslang av rostfritt st\u00e5l<\/strong> b\u00f6r utf\u00f6ra dessa tester f\u00f6r att s\u00e4kerst\u00e4lla \u00f6verensst\u00e4mmelse med internationella s\u00e4kerhetsstandarder.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 9626 Stainless Steel Needle Tubing Test ISO 9626 specifies the requirements and test methods for stainless steel needle tubing used in the manufacture of medical devices such as hypodermic needles and cannulas. This international standard ensures that the tubing used in medical applications meets consistent performance and safety requirements. Two key tests under ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2429","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/sv\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 9626 Stainless Steel Needle Tubing Test ISO 9626 specifies the requirements and test methods for stainless steel needle tubing used in the manufacture of medical devices such as hypodermic needles and cannulas. This international standard ensures that the tubing used in medical applications meets consistent performance and safety requirements. Two key tests under ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/comments?post=2429"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2429\/revisions"}],"predecessor-version":[{"id":2445,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2429\/revisions\/2445"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/media?parent=2429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/categories?post=2429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/tags?post=2429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}