{"id":2225,"date":"2025-07-17T03:26:50","date_gmt":"2025-07-17T03:26:50","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2225"},"modified":"2025-07-17T03:32:17","modified_gmt":"2025-07-17T03:32:17","slug":"break-loose-and-glide-force-testing","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/sv\/break-loose-and-glide-force-testing\/","title":{"rendered":"Test av l\u00f6sg\u00f6rings- och glidkraft f\u00f6r papper: ISO 7886 och sprututv\u00e4rdering"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2225\" class=\"elementor elementor-2225\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9145dad e-flex e-con-boxed e-con e-parent\" data-id=\"9145dad\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a89c638 elementor-widget elementor-widget-heading\" data-id=\"a89c638\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testning av brytkraft och glidkraft: En viktig indikator p\u00e5 sprutans prestanda<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b6a1371 e-flex e-con-boxed e-con e-parent\" data-id=\"b6a1371\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-693eb6e elementor-widget elementor-widget-text-editor\" data-id=\"693eb6e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"538\" data-end=\"945\">Inom l\u00e4kemedels- och medicinteknikbranscherna, <strong data-start=\"591\" data-end=\"630\">test av bryt- och glidkraft<\/strong> \u00e4r ett viktigt f\u00f6rfarande som anv\u00e4nds f\u00f6r att utv\u00e4rdera sprutornas anv\u00e4ndbarhet och kvalitet. Dessa tester fastst\u00e4ller hur stor kraft som kr\u00e4vs f\u00f6r att p\u00e5b\u00f6rja (lossa) och forts\u00e4tta (glida) kolvens r\u00f6relse inuti sprutcylindern. Resultaten har direkt inverkan p\u00e5 produktens \u00f6verensst\u00e4mmelse med g\u00e4llande krav, injektionskomforten och patients\u00e4kerheten.<\/p><p data-start=\"947\" data-end=\"1391\">Denna testmetod \u00e4r s\u00e4rskilt viktig f\u00f6r tillverkare som utvecklar <strong data-start=\"1016\" data-end=\"1091\">f\u00f6rfyllda sprutor, sterila delkomponenter och komponenter till autoinjektorer<\/strong>. En kolv som sitter f\u00f6r h\u00e5rt eller f\u00f6r l\u00f6st kan leda till doseringsfel, att kolven lossnar eller ett oj\u00e4mnt l\u00e4kemedelsfl\u00f6de \u2013 vilket allt utg\u00f6r s\u00e4kerhetsrisker. Av denna anledning beskrivs testf\u00f6rfarandet tydligt i flera internationella standarder, d\u00e4ribland <strong data-start=\"1341\" data-end=\"1355\">ISO 7886-1<\/strong>, <strong data-start=\"1357\" data-end=\"1372\">ISO 11040-4<\/strong>, och <strong data-start=\"1378\" data-end=\"1390\">ISO 8537<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ee73ce6 e-flex e-con-boxed e-con e-parent\" data-id=\"ee73ce6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7316cbe elementor-widget elementor-widget-heading\" data-id=\"7316cbe\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Provning av glidkraft hos sprutor och internationella standarder f\u00f6r \u00f6verensst\u00e4mmelse<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4fe64ba e-flex e-con-boxed e-con e-parent\" data-id=\"4fe64ba\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-697f2ea elementor-widget elementor-widget-text-editor\" data-id=\"697f2ea\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1470\" data-end=\"1745\">Tillsynsmyndigheterna har fastst\u00e4llt strikta krav f\u00f6r att s\u00e4kerst\u00e4lla att sprutornas prestanda \u00e4r tillf\u00f6rlitlig och reproducerbar. <strong data-start=\"1585\" data-end=\"1616\">Provning av glidmotst\u00e5ndet hos sprutor<\/strong> utv\u00e4rderar friktionsbeteendet under angivna f\u00f6rh\u00e5llanden, i syfte att uppt\u00e4cka variationer i sm\u00f6rjning eller materialegenskaper.<\/p><p data-start=\"1747\" data-end=\"2087\"><strong data-start=\"1747\" data-end=\"1761\">ISO 7886-1<\/strong><br data-start=\"1761\" data-end=\"1764\" \/>Denna standard g\u00e4ller f\u00f6r <strong data-start=\"1789\" data-end=\"1820\">sterila eng\u00e5ngssprutor<\/strong>. Den fastst\u00e4ller metoder f\u00f6r kraftm\u00e4tning av b\u00e5de lossnings- och glidv\u00e4rden, vilka m\u00e5ste ligga inom f\u00f6rutbest\u00e4mda intervall f\u00f6r att garantera en smidig drift. Den testhastighet som vanligtvis anv\u00e4nds \u00e4r <strong data-start=\"2010\" data-end=\"2024\">100 mm\/min<\/strong>, och datainsamling med h\u00f6g frekvens (\u2265500 Hz) rekommenderas.<\/p><p data-start=\"2089\" data-end=\"2451\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"2089\" data-end=\"2104\">ISO 11040-4<\/strong><\/a><br data-start=\"2104\" data-end=\"2107\" \/>Med fokus p\u00e5 <strong data-start=\"2118\" data-end=\"2158\">glasfat f\u00f6r f\u00f6rfyllda sprutor<\/strong>, denna standard omfattar <strong data-start=\"2183\" data-end=\"2194\">Bilaga E<\/strong>, som anger provningsmetoden f\u00f6r glidkraft f\u00f6r sterila delkomponenter. Den beskriver kraven f\u00f6r <strong data-start=\"2300\" data-end=\"2366\">kolvstopp, cylinderns insida och sm\u00f6rjning med silikonolja<\/strong>. En j\u00e4mn och l\u00e5g friktion \u00e4r avg\u00f6rande f\u00f6r att uppfylla de kriterier som fastst\u00e4lls i denna standard.<\/p><p data-start=\"2453\" data-end=\"2717\"><strong data-start=\"2453\" data-end=\"2465\">ISO 8537<\/strong><br data-start=\"2465\" data-end=\"2468\" \/>Avsedd f\u00f6r <strong data-start=\"2481\" data-end=\"2501\">Insulinsprutor<\/strong>, denna standard l\u00e4gger tonvikten p\u00e5 noggrann dosering genom styrning av kolvens r\u00f6relse. Glidmotst\u00e5ndet \u00e4r s\u00e4rskilt viktigt i insulinadministreringsanordningar, d\u00e4r en j\u00e4mn injektionshastighet s\u00e4kerst\u00e4ller en s\u00e4ker glukosreglering.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f96e75b e-flex e-con-boxed e-con e-parent\" data-id=\"f96e75b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab96e67 elementor-widget elementor-widget-heading\" data-id=\"ab96e67\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testf\u00f6rfaranden och parametrar<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e898377 e-flex e-con-boxed e-con e-parent\" data-id=\"e898377\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6c4a14 elementor-widget elementor-widget-text-editor\" data-id=\"e6c4a14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2760\" data-end=\"2842\">F\u00f6rfarandet f\u00f6r provning av lossnings- och glidkraft f\u00f6ljer ett strukturerat uppl\u00e4gg:<\/p><ol data-start=\"2844\" data-end=\"3739\"><li data-start=\"2844\" data-end=\"2990\"><p data-start=\"2847\" data-end=\"2990\"><strong data-start=\"2847\" data-end=\"2862\">F\u00f6rberedelser<\/strong><br data-start=\"2862\" data-end=\"2865\" \/>Anv\u00e4ndning <strong data-start=\"2872\" data-end=\"2901\">steriliserade tomma sprutor<\/strong> redo f\u00f6r p\u00e5fyllning. Montera en kompatibel kolvpropp med fastst\u00e4llda sm\u00f6rjniv\u00e5er.<\/p><\/li><li data-start=\"2992\" data-end=\"3220\"><p data-start=\"2995\" data-end=\"3220\"><strong data-start=\"2995\" data-end=\"3004\">Inst\u00e4llningar<\/strong><br data-start=\"3004\" data-end=\"3007\" \/>Placera sprutan i en universell provningsmaskin eller i specialutrustning, till exempel <strong data-start=\"3094\" data-end=\"3155\">Cell Instruments SSR-01 Sprutans glidmotst\u00e5ndsprovare<\/strong>. F\u00e4st den s\u00e5 att f\u00e4stelementen \u00e4r korrekt inriktade f\u00f6r att s\u00e4kerst\u00e4lla axiell r\u00f6relse.<\/p><\/li><li data-start=\"3222\" data-end=\"3419\"><p data-start=\"3225\" data-end=\"3419\"><strong data-start=\"3225\" data-end=\"3238\">Genomf\u00f6rande<\/strong><br data-start=\"3238\" data-end=\"3241\" \/>Starta kolvr\u00f6relsen med en hastighet av 100 mm\/min. Provningsutrustningen registrerar <strong data-start=\"3319\" data-end=\"3355\">frigjord kraft (initial topp)<\/strong> och <strong data-start=\"3364\" data-end=\"3418\">glidkraft (medelv\u00e4rdet f\u00f6r kraften under en kontinuerlig r\u00f6relse)<\/strong>.<\/p><\/li><li data-start=\"3421\" data-end=\"3597\"><p data-start=\"3424\" data-end=\"3472\"><strong data-start=\"3424\" data-end=\"3440\">Datainsamling<\/strong><br data-start=\"3440\" data-end=\"3443\" \/>Registrera viktiga uppgifter, bland annat:<\/p><ul data-start=\"3476\" data-end=\"3597\"><li data-start=\"3476\" data-end=\"3500\"><p data-start=\"3478\" data-end=\"3500\">Frig\u00f6ringskraft (f\u2080)<\/p><\/li><li data-start=\"3504\" data-end=\"3526\"><p data-start=\"3506\" data-end=\"3526\">Genomsnittlig glidflygkraft (F)<\/p><\/li><li data-start=\"3530\" data-end=\"3558\"><p data-start=\"3532\" data-end=\"3558\">Maximal glidkraft (F\u2098\u2090\u2093)<\/p><\/li><li data-start=\"3562\" data-end=\"3597\"><p data-start=\"3564\" data-end=\"3597\">Resans l\u00e4ngd och testets varaktighet<\/p><\/li><\/ul><\/li><li data-start=\"3599\" data-end=\"3739\"><p data-start=\"3602\" data-end=\"3739\"><strong data-start=\"3602\" data-end=\"3616\">Utv\u00e4rdering<\/strong><br data-start=\"3616\" data-end=\"3619\" \/>Resultaten j\u00e4mf\u00f6rs med gr\u00e4nsv\u00e4rdena i ISO 7886-1, ISO 11040-4 eller ISO 8537, beroende p\u00e5 spruttyp.<\/p><\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94fd533 e-flex e-con-boxed e-con e-parent\" data-id=\"94fd533\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f724e30 elementor-widget elementor-widget-heading\" data-id=\"f724e30\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vanliga problem som uppt\u00e4cks vid glidkraftstestning<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-422d4c4 e-flex e-con-boxed e-con e-parent\" data-id=\"422d4c4\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbff8ed elementor-widget elementor-widget-text-editor\" data-id=\"dbff8ed\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3802\" data-end=\"3888\">Tester av lossnings- och glidkraft avsl\u00f6jar allvarliga kvalitetsproblem hos sprutor, till exempel:<\/p><ul data-start=\"3890\" data-end=\"4134\"><li data-start=\"3890\" data-end=\"3961\"><p data-start=\"3892\" data-end=\"3961\"><strong data-start=\"3892\" data-end=\"3914\">F\u00f6r stor friktion<\/strong> p\u00e5 grund av otillr\u00e4cklig eller oj\u00e4mn silikonbel\u00e4ggning<\/p><\/li><li data-start=\"3962\" data-end=\"4012\"><p data-start=\"3964\" data-end=\"4012\"><strong data-start=\"3964\" data-end=\"3985\">Fastnande kolvar<\/strong>, vilket p\u00e5verkar dosens noggrannhet<\/p><\/li><li data-start=\"4013\" data-end=\"4072\"><p data-start=\"4015\" data-end=\"4072\"><strong data-start=\"4015\" data-end=\"4043\">Materialinkompatibilitet<\/strong> mellan cylindern och kolven<\/p><\/li><li data-start=\"4073\" data-end=\"4134\"><p data-start=\"4075\" data-end=\"4134\"><strong data-start=\"4075\" data-end=\"4100\">Fr\u00e5nkoppling av kolven<\/strong> eller t\u00e4tningsl\u00e4ckage vid axiell belastning<\/p><\/li><\/ul><p data-start=\"4136\" data-end=\"4237\">Genom att identifiera dessa problem under forskning och utveckling eller under produktionen skyddas efterf\u00f6ljande processer och patienternas behandlingsresultat.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-358cd95 e-flex e-con-boxed e-con e-parent\" data-id=\"358cd95\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1be87be elementor-widget elementor-widget-heading\" data-id=\"1be87be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rekommenderad utrustning: Cell Instruments SSR-01 \u2013 testare f\u00f6r glidmotst\u00e5nd med spruta<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-97d0577 e-flex e-con-boxed e-con e-parent\" data-id=\"97d0577\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4f6c718 e-con-full e-flex e-con e-child\" data-id=\"4f6c718\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-495d6e6 elementor-widget elementor-widget-text-editor\" data-id=\"495d6e6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4330\" data-end=\"4474\">F\u00f6r att kunna utf\u00f6ra dessa tester p\u00e5 ett korrekt s\u00e4tt och i enlighet med ISO-standarderna erbjuder Cell Instruments<a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/syringes-plunger-glide-force-tester\/\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"4430\" data-end=\"4440\">SSR-01<\/strong><\/a>. Denna utrustning \u00e4r avsedd f\u00f6r:<\/p><ul data-start=\"4476\" data-end=\"4766\"><li data-start=\"4476\" data-end=\"4534\"><p data-start=\"4478\" data-end=\"4534\"><strong data-start=\"4478\" data-end=\"4501\">Exakt m\u00e4tning<\/strong> av brytkraft och glidkraft<\/p><\/li><li data-start=\"4535\" data-end=\"4596\"><p data-start=\"4537\" data-end=\"4596\"><strong data-start=\"4537\" data-end=\"4563\">Justerbara testhastigheter<\/strong> och programmerbara testinst\u00e4llningar<\/p><\/li><li data-start=\"4597\" data-end=\"4657\"><p data-start=\"4599\" data-end=\"4657\"><strong data-start=\"4599\" data-end=\"4625\">Visning av data i realtid<\/strong> via en 7-tums HMI-peksk\u00e4rm<\/p><\/li><li data-start=\"4658\" data-end=\"4712\"><p data-start=\"4660\" data-end=\"4712\"><strong data-start=\"4660\" data-end=\"4686\">Inbyggd mikroskrivare<\/strong> f\u00f6r omedelbar rapportering<\/p><\/li><li data-start=\"4713\" data-end=\"4766\"><p data-start=\"4715\" data-end=\"4766\"><strong data-start=\"4715\" data-end=\"4736\">Flexibla fixturer<\/strong> f\u00f6r olika spruttyper<\/p><\/li><\/ul><p data-start=\"4768\" data-end=\"4893\">Tack vare det intuitiva gr\u00e4nssnittet och den stabila prestandan \u00e4r den perfekt f\u00f6r b\u00e5de <strong data-start=\"4838\" data-end=\"4859\">kvalitetss\u00e4kring<\/strong> och <strong data-start=\"4864\" data-end=\"4892\">laboratorier f\u00f6r produktutveckling<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7285d35 e-con-full e-flex e-con e-child\" data-id=\"7285d35\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f5e0678 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"f5e0678\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp\" class=\"attachment-medium_large size-medium_large wp-image-2227\" alt=\"Testmaskinen Break Loose and Glide Force \u2013 en m\u00e5ngsidig och h\u00f6gprecisionsl\u00f6sning som \u00e4r skr\u00e4ddarsydd f\u00f6r provning av sprutor och f\u00f6rpackningsmaterial.\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-1024x1024.webp 1024w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1.webp 1080w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d9ef370 e-flex e-con-boxed e-con e-parent\" data-id=\"d9ef370\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-354bdaf elementor-widget elementor-widget-heading\" data-id=\"354bdaf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Varf\u00f6r dessa tester \u00e4r viktiga f\u00f6r tillverkarna<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9e66002 e-flex e-con-boxed e-con e-parent\" data-id=\"9e66002\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-aae1c87 e-con-full e-flex e-con e-child\" data-id=\"aae1c87\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf49733 elementor-widget elementor-widget-video\" data-id=\"bf49733\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=Jv55XhLaURk&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;modestbranding&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2cf2943 e-con-full e-flex e-con e-child\" data-id=\"2cf2943\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c0dc11 elementor-widget elementor-widget-text-editor\" data-id=\"0c0dc11\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"4948\" data-end=\"5007\"><p data-start=\"4950\" data-end=\"5007\"><strong data-start=\"4950\" data-end=\"4981\">St\u00f6djer inl\u00e4mning av dokument till tillsynsmyndigheter<\/strong> med ISO-kompatibla data<\/p><\/li><li data-start=\"5008\" data-end=\"5082\"><p data-start=\"5010\" data-end=\"5082\"><strong data-start=\"5010\" data-end=\"5040\">F\u00f6rb\u00e4ttrar produktens anv\u00e4ndarv\u00e4nlighet<\/strong> genom att f\u00f6rhindra att v\u00e4tskan fastnar eller att fl\u00f6det blir oregelbundet<\/p><\/li><li data-start=\"5083\" data-end=\"5144\"><p data-start=\"5085\" data-end=\"5144\"><strong data-start=\"5085\" data-end=\"5115\">F\u00f6rb\u00e4ttrar enhetligheten i satserna<\/strong> f\u00f6r storskalig produktion<\/p><\/li><li data-start=\"5145\" data-end=\"5201\"><p data-start=\"5147\" data-end=\"5201\"><strong data-start=\"5147\" data-end=\"5173\">Minskar risken f\u00f6r \u00e5terkallelse<\/strong> p\u00e5 grund av ett mekaniskt fel<\/p><\/li><li data-start=\"5202\" data-end=\"5283\"><p data-start=\"5204\" data-end=\"5283\"><strong data-start=\"5204\" data-end=\"5232\">\u00d6kar patientens komfort<\/strong>, s\u00e4rskilt f\u00f6r autoinjektorer och insulinsprutor<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0c0191b e-flex e-con-boxed e-con e-parent\" data-id=\"0c0191b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4180a60 elementor-widget elementor-widget-heading\" data-id=\"4180a60\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Slutsats<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fa9b8b6 e-flex e-con-boxed e-con e-parent\" data-id=\"fa9b8b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-28ecdb2 elementor-widget elementor-widget-text-editor\" data-id=\"28ecdb2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5306\" data-end=\"5729\"><strong data-start=\"5306\" data-end=\"5345\">Test av bryt- och glidkraft<\/strong> \u00e4r en grundl\u00e4ggande del av kvalitetsbed\u00f6mningen av sprutor. Att f\u00f6lja <a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5411\" data-end=\"5425\">ISO 7886-1<\/strong><\/a>, <strong data-start=\"5427\" data-end=\"5442\">ISO 11040-4<\/strong>, och <strong data-start=\"5448\" data-end=\"5460\">ISO 8537<\/strong> s\u00e4kerst\u00e4ller produktens tillf\u00f6rlitlighet, efterlevnad av lagstiftningen och s\u00e4ker l\u00e4kemedelstillf\u00f6rsel. Genom att investera i avancerade instrument som <strong data-start=\"5583\" data-end=\"5615\">SSR-01 fr\u00e5n<a href=\"https:\/\/www.celtec.cn\" target=\"_blank\" rel=\"noopener\"> Cellinstrument<\/a><\/strong>, kan tillverkarna med tillf\u00f6rsikt leverera h\u00f6gpresterande sprutor som uppfyller b\u00e5de branschens och patienternas f\u00f6rv\u00e4ntningar.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Test av bryt- och glidkraft: En nyckelindikator f\u00f6r sprutans prestanda Inom l\u00e4kemedels- och medicintekniska industrier \u00e4r testning av bryt- och glidkraft en kritisk procedur som anv\u00e4nds f\u00f6r att utv\u00e4rdera sprutans anv\u00e4ndbarhet och kvalitet. Dessa tester avg\u00f6r hur mycket kraft som kr\u00e4vs f\u00f6r att starta (bryta loss) och forts\u00e4tta (glida) r\u00f6relsen [...].<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2225","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/sv\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Break Loose and Glide Force Testing: A Key Indicator of Syringe Performance In the pharmaceutical and medical device industries, break loose and glide force testing is a critical procedure used to evaluate the usability and quality of syringes. These tests determine how much force is required to start (break loose) and continue (glide) the movement&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2225","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/comments?post=2225"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2225\/revisions"}],"predecessor-version":[{"id":2251,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2225\/revisions\/2251"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/media?parent=2225"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/categories?post=2225"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/tags?post=2225"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}