{"id":2087,"date":"2025-04-27T08:38:09","date_gmt":"2025-04-27T08:38:09","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2087"},"modified":"2025-04-27T08:47:19","modified_gmt":"2025-04-27T08:47:19","slug":"luer-lock-rings-pull-off-force-test","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/sv\/luer-lock-rings-pull-off-force-test\/","title":{"rendered":"Luer Lock-ringar - Test av utdragskraft - ISO 11040-4 Bilaga G3"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2087\" class=\"elementor elementor-2087\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a57182 e-flex e-con-boxed e-con e-parent\" data-id=\"7a57182\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-caf1aa9 elementor-widget elementor-widget-heading\" data-id=\"caf1aa9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer Lock-ringar Avdragskraft<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27efcf2 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"27efcf2\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49edf54 elementor-widget elementor-widget-heading\" data-id=\"49edf54\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bilaga G3<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-03ddeb3 e-flex e-con-boxed e-con e-parent\" data-id=\"03ddeb3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ccea8f2 elementor-widget elementor-widget-text-editor\" data-id=\"ccea8f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"455\" data-end=\"1006\">Inom l\u00e4kemedels- och medicinteknikindustrin \u00e4r <em data-start=\"531\" data-end=\"563\">luerl\u00e5sringar avdragskraft<\/em> \u00e4r en kritisk parameter f\u00f6r att s\u00e4kerst\u00e4lla tillf\u00f6rlitligheten och s\u00e4kerheten hos f\u00f6rfyllda sprutor. Korrekt testning verifierar att luerlockadaptern (LLA) sitter fast ordentligt f\u00f6r att f\u00f6rhindra oavsiktlig lossning under anv\u00e4ndning.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c963d8 elementor-widget elementor-widget-heading\" data-id=\"0c963d8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Betydelsen av Luer Lock-ringar Pull-Off-kraft<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee545a5 elementor-widget elementor-widget-text-editor\" data-id=\"ee545a5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1013\" data-end=\"1449\">Den <em data-start=\"1076\" data-end=\"1108\">luerl\u00e5sringar avdragskraft<\/em> m\u00e4ter den axiella styrka som kr\u00e4vs f\u00f6r att lossa LLA-kragsystemet fr\u00e5n sprutans hylsa. Noggrann testning s\u00e4kerst\u00e4ller att sprutan bibeh\u00e5ller sin integritet under hantering, fyllning och administrering, vilket minskar risken f\u00f6r fel p\u00e5 enheten. Dessa tester \u00e4r obligatoriska enligt g\u00e4llande standarder f\u00f6r att skydda patients\u00e4kerheten och st\u00f6dja p\u00e5st\u00e5enden om produktprestanda.<\/p><p class=\"\" data-start=\"1451\" data-end=\"1734\">F\u00f6r tillverkare och kvalitetsinspektionsorgan, s\u00e4rskilt de som betj\u00e4nar medicinska, farmaceutiska och h\u00e4lsov\u00e5rdsmarknader, \u00e4r det viktigt att beh\u00e4rska detta test. <strong data-start=\"1610\" data-end=\"1630\">Cellinstrument<\/strong> erbjuder avancerade l\u00f6sningar som uppfyller dessa str\u00e4nga krav med h\u00f6g precision och tillf\u00f6rlitlighet.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4912cb5 elementor-widget elementor-widget-heading\" data-id=\"4912cb5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bilaga G3 Krav<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9bf8207 elementor-widget elementor-widget-text-editor\" data-id=\"9bf8207\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1741\" data-end=\"2070\"><em data-start=\"1838\" data-end=\"1851\">ISO 11040-4<\/em> definierar kraven f\u00f6r glasfat f\u00f6r injicerbara l\u00e4kemedel och steriliserade sprutor som \u00e4r f\u00e4rdigmonterade och klara f\u00f6r fyllning. Specifikt f\u00f6r detta, <em data-start=\"1981\" data-end=\"2003\">ISO 11040-4 Bilaga G3<\/em> beskriver metoden f\u00f6r att m\u00e4ta <em data-start=\"2037\" data-end=\"2069\">luerl\u00e5sringar avdragskraft<\/em>.<\/p><p class=\"\" data-start=\"2072\" data-end=\"2096\">Enligt bilaga G3:<\/p><ul data-start=\"2097\" data-end=\"2989\"><li class=\"\" data-start=\"2097\" data-end=\"2237\"><p class=\"\" data-start=\"2099\" data-end=\"2237\"><strong data-start=\"2099\" data-end=\"2112\">Princip<\/strong>: Testet utv\u00e4rderar om LLA-systemet kan motst\u00e5 en definierad axiell avdragskraft n\u00e4r det ansluts till en standard luerkoppling.<\/p><\/li><li class=\"\" data-start=\"2238\" data-end=\"2444\"><p class=\"\" data-start=\"2240\" data-end=\"2444\"><strong data-start=\"2240\" data-end=\"2253\">Apparat<\/strong>: En universell drag- och tryckprovningsmaskin kr\u00e4vs, som kan arbeta vid en <strong data-start=\"2346\" data-end=\"2373\">testhastighet p\u00e5 20 mm\/min<\/strong>. En lastcell med ett typiskt intervall p\u00e5 <strong data-start=\"2411\" data-end=\"2428\">10 N till 100 N<\/strong> m\u00e5ste anv\u00e4ndas.<\/p><\/li><li class=\"\" data-start=\"2445\" data-end=\"2524\"><p class=\"\" data-start=\"2447\" data-end=\"2524\"><strong data-start=\"2447\" data-end=\"2462\">F\u00f6rberedelser<\/strong>: Testproverna m\u00e5ste motsvara f\u00f6rh\u00e5llandena i produktionsprocessen.<\/p><\/li><li class=\"\" data-start=\"2525\" data-end=\"2751\"><p class=\"\" data-start=\"2527\" data-end=\"2751\"><strong data-start=\"2527\" data-end=\"2540\">F\u00f6rfarande<\/strong>: Efter att spetslocket avl\u00e4gsnats placeras sprutan i en h\u00e5llare utan att f\u00f6rtryck appliceras p\u00e5 LLA. Maskinen drar sedan med konstant hastighet tills LLA-kragen lossnar, varvid den maximala kraften registreras.<\/p><\/li><li class=\"\" data-start=\"2752\" data-end=\"2851\"><p class=\"\" data-start=\"2754\" data-end=\"2851\"><strong data-start=\"2754\" data-end=\"2765\">Resultat<\/strong>: Den maximala kraften fr\u00e5n kraftf\u00f6rskjutningskurvan representerar avdragningsstyrkan.<\/p><\/li><li class=\"\" data-start=\"2852\" data-end=\"2989\"><p class=\"\" data-start=\"2854\" data-end=\"2989\"><strong data-start=\"2854\" data-end=\"2871\">Dokumentation<\/strong>: Rapporten ska inneh\u00e5lla testhastighet, toppv\u00e4rde, antal prover, godk\u00e4nda\/icke godk\u00e4nda resultat och eventuella avvikelser som observerats.<\/p><\/li><\/ul><p class=\"\" data-start=\"2991\" data-end=\"3102\">F\u00f6ljande <em data-start=\"3001\" data-end=\"3023\">ISO 11040-4 Bilaga G3<\/em> s\u00e4kerst\u00e4ller att resultaten \u00e4r tillf\u00f6rlitliga, reproducerbara och internationellt accepterade.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd67e63 elementor-widget elementor-widget-heading\" data-id=\"cd67e63\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hur man utf\u00f6r Luer Lock Rings Pull-Off Force Test<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec7a39c elementor-widget elementor-widget-text-editor\" data-id=\"ec7a39c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3109\" data-end=\"3263\">Genomf\u00f6ra en noggrann <a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/luer-lock-rings-pull-off-force-test\/\"><em data-start=\"3193\" data-end=\"3225\">luerl\u00e5sringar avdragskraft<\/em> test<\/a> omfattar flera grundl\u00e4ggande steg:<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-08466dd e-con-full e-flex e-con e-child\" data-id=\"08466dd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-33a3c77 elementor-widget elementor-widget-text-editor\" data-id=\"33a3c77\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>1. Beredning av prov<\/strong><\/p><ul><li data-start=\"3292\" data-end=\"3363\">Anv\u00e4nd steriliserade, monterade sprutor som speglar produktionsf\u00f6rh\u00e5llandena.<\/li><li data-start=\"3292\" data-end=\"3363\">Ta bort spetslocket utan att belasta LLA-kragsystemet.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d451ca elementor-widget elementor-widget-text-editor\" data-id=\"5d451ca\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3427\" data-end=\"3452\"><strong>2. Uppl\u00e4ggning av testet<\/strong><\/p><ul><li data-start=\"3455\" data-end=\"3551\">Montera sprutan i <strong data-start=\"3480\" data-end=\"3498\">Spruth\u00e5llare<\/strong> och s\u00e4kra LLA-kragen i <strong data-start=\"3532\" data-end=\"3550\">gripanordning<\/strong>.<\/li><li data-start=\"3455\" data-end=\"3551\">Se till att inget tryck ut\u00f6vas p\u00e5 kragen under installationen.<\/li><li data-start=\"3455\" data-end=\"3551\">Kalibrera lastcellen till \"noll\" utan att applicera f\u00f6rsp\u00e4nning.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-95882a3 e-con-full e-flex e-con e-child\" data-id=\"95882a3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b1efd9c elementor-widget elementor-widget-text-editor\" data-id=\"b1efd9c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3675\" data-end=\"3699\"><strong>Utf\u00f6rande av testet<\/strong><\/p><ul><li>St\u00e4ll in maskinens hastighet p\u00e5 <strong data-start=\"3727\" data-end=\"3740\">20 mm\/min<\/strong>.<\/li><li>P\u00e5b\u00f6rja dragprovet och \u00f6vervaka kraft kontra f\u00f6rskjutning.<\/li><li>Registrera den maximala kraften n\u00e4r LLA-kragen lossnar fr\u00e5n sprutan.<\/li><\/ul><p class=\"\" data-start=\"3875\" data-end=\"3902\"><strong data-start=\"3875\" data-end=\"3900\">Analys av resultaten<\/strong><\/p><ul><li data-start=\"3905\" data-end=\"3964\">Identifiera den h\u00f6gsta punkten p\u00e5 kraft-f\u00f6rskjutningsdiagrammet.<\/li><li data-start=\"3905\" data-end=\"3964\">J\u00e4mf\u00f6r med angivna gr\u00e4nsv\u00e4rden f\u00f6r att avg\u00f6ra om det \u00e4r godk\u00e4nt eller inte.<\/li><li data-start=\"3905\" data-end=\"3964\">Dokumentera alla parametrar, inklusive provm\u00e4ngder, fel och avvikelser.<\/li><\/ul><p class=\"\" data-start=\"4110\" data-end=\"4222\">A <strong data-start=\"4112\" data-end=\"4139\">samplingsfrekvens p\u00e5 500 Hz<\/strong> rekommenderas f\u00f6r att s\u00e4kerst\u00e4lla korrekta toppm\u00e4tningar under testningen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37beef7 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"37beef7\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"496\" height=\"500\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp\" class=\"attachment-full size-full wp-image-2089\" alt=\"Luer Lock-ringar - Test av utdragskraft - ISO 11040-4 Bilaga G3\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp 496w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-298x300.webp 298w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-150x150.webp 150w\" sizes=\"(max-width: 496px) 100vw, 496px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fe809e1 e-con-full e-flex e-con e-child\" data-id=\"fe809e1\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-517a11d e-con-full e-flex e-con e-child\" data-id=\"517a11d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-661f7f9 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"661f7f9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 l\u00e4ckagetest av sprutor\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-63b418a e-con-full e-flex e-con e-child\" data-id=\"63b418a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-45b4a2d elementor-widget elementor-widget-heading\" data-id=\"45b4a2d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rekommenderad utrustning f\u00f6r korrekt testning<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef6391d elementor-widget elementor-widget-text-editor\" data-id=\"ef6391d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4229\" data-end=\"4441\">Vid <strong data-start=\"4281\" data-end=\"4301\">Cellinstrument<\/strong>\u00e4r vi specialiserade p\u00e5 att tillhandah\u00e5lla <strong data-start=\"4330\" data-end=\"4375\">universella drag- och tryckprovare<\/strong> anpassade f\u00f6r sprutprovningsapplikationer. V\u00e5ra system erbjuder:<\/p><ul data-start=\"4442\" data-end=\"4731\"><li class=\"\" data-start=\"4442\" data-end=\"4503\"><p class=\"\" data-start=\"4444\" data-end=\"4503\">H\u00f6gfrekvent sampling (upp till 500 Hz) f\u00f6r h\u00f6gsta noggrannhet.<\/p><\/li><li class=\"\" data-start=\"4504\" data-end=\"4582\"><p class=\"\" data-start=\"4506\" data-end=\"4582\">Specialanpassade spruth\u00e5llare och LLA-gripdon enligt ISO-specifikationer.<\/p><\/li><li class=\"\" data-start=\"4583\" data-end=\"4658\"><p class=\"\" data-start=\"4585\" data-end=\"4658\">Lastceller som l\u00e4mpar sig f\u00f6r en rad olika testkrafter mellan 10 N och 100 N.<\/p><\/li><li class=\"\" data-start=\"4659\" data-end=\"4731\"><p class=\"\" data-start=\"4661\" data-end=\"4731\">Intuitiv programvara f\u00f6r fullst\u00e4ndig sp\u00e5rbarhet av parametrar och enkel rapportering.<\/p><\/li><\/ul><p class=\"\" data-start=\"4733\" data-end=\"4901\">V\u00e5ra l\u00f6sningar garanterar \u00f6verensst\u00e4mmelse med <em data-start=\"4773\" data-end=\"4786\">ISO 11040-4<\/em> och bidra till att s\u00e4kerst\u00e4lla h\u00f6gsta m\u00f6jliga produktkvalitet f\u00f6r v\u00e5ra kunder inom l\u00e4kemedels- och medicinteknikindustrin.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d05f85d elementor-widget elementor-widget-text-editor\" data-id=\"d05f85d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4908\" data-end=\"5324\">F\u00f6rst\u00e5else och korrekt m\u00e4tning av <em data-start=\"4968\" data-end=\"5000\">luerl\u00e5sringar avdragskraft<\/em> enligt <em data-start=\"5014\" data-end=\"5036\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Bilaga G3<\/em> \u00e4r avg\u00f6rande f\u00f6r att s\u00e4kerst\u00e4lla sprutans s\u00e4kerhet och tillf\u00f6rlitlighet. Genom att f\u00f6lja de korrekta metoderna och anv\u00e4nda kompatibla testinstrument med h\u00f6g precision fr\u00e5n <strong data-start=\"5187\" data-end=\"5207\">Cellinstrument<\/strong>kan kvalitetskontrollteam med s\u00e4kerhet verifiera produktens prestanda, uppfylla lagstadgade standarder och skydda slutanv\u00e4ndarna.<\/p><p class=\"\" data-start=\"5326\" data-end=\"5511\">Om du beh\u00f6ver hj\u00e4lp med att v\u00e4lja eller anpassa r\u00e4tt testutrustning f\u00f6r dina behov av spruttestning, <strong data-start=\"5437\" data-end=\"5471\">kontakta Cell Instruments idag<\/strong> f\u00f6r att utforska hela v\u00e5rt utbud av l\u00f6sningar.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Rings Pull-Off Force ISO 11040-4 Annex G3 Inom l\u00e4kemedels- och medicinteknisk industri \u00e4r luer lock-ringarnas dragkraft en kritisk parameter f\u00f6r att s\u00e4kerst\u00e4lla tillf\u00f6rlitligheten och s\u00e4kerheten hos f\u00f6rfyllda sprutor. Korrekt testning verifierar att luerl\u00e5sadaptern (LLA) \u00e4r s\u00e4kert fastsatt f\u00f6r att f\u00f6rhindra oavsiktlig lossning under anv\u00e4ndning. Betydelsen av [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2087","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/sv\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Lock Rings Pull-Off Force ISO 11040-4 Annex G3 In the pharmaceutical and medical device industries, the luer lock rings pull-off force is a critical parameter to ensure the reliability and safety of prefilled syringes. Proper testing verifies the secure attachment of the luer lock adaptor (LLA) to prevent accidental detachment during use. Importance of&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/comments?post=2087"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2087\/revisions"}],"predecessor-version":[{"id":2101,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2087\/revisions\/2101"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/media?parent=2087"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/categories?post=2087"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/tags?post=2087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}