{"id":2036,"date":"2025-04-14T09:07:36","date_gmt":"2025-04-14T09:07:36","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2036"},"modified":"2025-04-22T03:29:56","modified_gmt":"2025-04-22T03:29:56","slug":"syringe-leakage-testing-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/sv\/syringe-leakage-testing-iso-11040-4\/","title":{"rendered":"Test av sprutl\u00e4ckage - ISO 11040-4 Bilaga G2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2036\" class=\"elementor elementor-2036\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b47b928 e-flex e-con-boxed e-con e-parent\" data-id=\"b47b928\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e8261b4 elementor-widget elementor-widget-heading\" data-id=\"e8261b4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Test av sprutl\u00e4ckage<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6fa5bf elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"a6fa5bf\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03e5049 elementor-widget elementor-widget-heading\" data-id=\"03e5049\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bilaga G2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2170a2 e-flex e-con-boxed e-con e-parent\" data-id=\"b2170a2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec36001 elementor-widget elementor-widget-text-editor\" data-id=\"ec36001\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"375\" data-end=\"1050\">Inom omr\u00e5det tillverkning av l\u00e4kemedel och medicintekniska produkter, <em data-start=\"459\" data-end=\"484\">l\u00e4ckagetestning av sprutor<\/em> \u00e4r en kritisk kvalitetss\u00e4kringsprocess. Den s\u00e4kerst\u00e4ller att <strong data-start=\"542\" data-end=\"564\">f\u00f6rfyllda sprutor<\/strong> beh\u00e5ller sin sterilitet och inte l\u00e4cker under transport, f\u00f6rvaring eller anv\u00e4ndning. F\u00f6r att uppfylla str\u00e4nga regulatoriska f\u00f6rv\u00e4ntningar m\u00e5ste tillverkarna f\u00f6lja internationella standarder som <strong data-start=\"736\" data-end=\"751\">ISO 11040-4<\/strong>, s\u00e4rskilt <strong data-start=\"764\" data-end=\"776\">Bilaga G2<\/strong>, som inneh\u00e5ller en beskrivning av <strong data-start=\"797\" data-end=\"830\">Testmetod f\u00f6r v\u00e4tskel\u00e4ckage<\/strong> f\u00f6r f\u00f6rslutningssystem f\u00f6r sprutor.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ebf1ff6 elementor-widget elementor-widget-heading\" data-id=\"ebf1ff6\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vad \u00e4r sprutl\u00e4ckagetestning?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f9a4f4 elementor-widget elementor-widget-text-editor\" data-id=\"1f9a4f4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1115\" data-end=\"1487\">L\u00e4ckagetestning av sprutor utv\u00e4rderar om sprutans f\u00f6rslutningssystem - antingen en <strong data-start=\"1232\" data-end=\"1249\">N\u00e5lskydd<\/strong> eller <strong data-start=\"1253\" data-end=\"1264\">spetslock<\/strong>-kan motst\u00e5 inre tryck utan att v\u00e4tska l\u00e4cker ut. Enligt <strong data-start=\"1344\" data-end=\"1368\">ISO 11040-4 Bilaga G2<\/strong>\u00e4r standardprovtrycket <strong data-start=\"1400\" data-end=\"1411\">110 kPa<\/strong>som simulerar verkliga f\u00f6rh\u00e5llanden vid fyllning eller transport av sprutor.<\/p><h3 data-start=\"1489\" data-end=\"1718\">Varf\u00f6r det \u00e4r viktigt<\/h3><p class=\"\" data-start=\"1489\" data-end=\"1718\">L\u00e4ckage \u00e4ventyrar inte bara produktens sterilitet, utan kan ocks\u00e5 orsaka felaktiga doseringar och s\u00e4kerhetsrisker. Efter en <strong data-start=\"1626\" data-end=\"1657\">standardiserat testf\u00f6rfarande<\/strong> s\u00e4kerst\u00e4ller konsekvens, tillf\u00f6rlitlighet och regelefterlevnad.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d11a485 elementor-widget elementor-widget-heading\" data-id=\"d11a485\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span style=\"font-size: 2.82353rem;\">ISO 11040-4 Bilaga G2 <\/span>Testkrav<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-036bd3c e-con-full e-flex e-con e-child\" data-id=\"036bd3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7d2acf2 e-con-full e-flex e-con e-child\" data-id=\"7d2acf2\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8616b8 e-con-full e-flex e-con e-child\" data-id=\"f8616b8\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3773a30 elementor-widget elementor-widget-heading\" data-id=\"3773a30\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Prov f\u00f6r test av sprutl\u00e4ckage<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f461568 elementor-widget elementor-widget-text-editor\" data-id=\"f461568\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Anv\u00e4nd endast reagenser av analytisk kvalitet och sterila, f\u00e4rdigfyllda sprutunderenheter. Proverna m\u00e5ste f\u00f6rbli or\u00f6rda i <strong data-start=\"1927\" data-end=\"1948\">minst 12 timmar<\/strong> efter st\u00e4ngning innan provning p\u00e5b\u00f6rjas. Denna retentionstid s\u00e4kerst\u00e4ller stabilisering av f\u00f6rslutningen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-551a42f elementor-widget elementor-widget-heading\" data-id=\"551a42f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">L\u00e4ckagetestare f\u00f6r sprutor<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9fd1b0f elementor-widget elementor-widget-text-editor\" data-id=\"9fd1b0f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2046\" data-end=\"2117\">I bilaga G2 specificeras tv\u00e5 huvudsakliga testmetoder:<\/p><ul><li data-start=\"2120\" data-end=\"2211\"><strong data-start=\"2120\" data-end=\"2149\">Mekanisk trycks\u00e4ttning<\/strong> med hj\u00e4lp av en <strong data-start=\"2158\" data-end=\"2211\">universell drag- och tryckprovningsmaskin<\/strong><\/li><li data-start=\"2120\" data-end=\"2211\"><strong style=\"font-size: 16px;\" data-start=\"2214\" data-end=\"2253\">Trycks\u00e4ttning baserad p\u00e5 tryckluft<\/strong><span style=\"font-size: 16px;\">, f\u00f6redras d\u00e4r v\u00e4ggfriktion p\u00e5verkar noggrannheten<\/span><\/li><\/ul><p class=\"\" data-start=\"2303\" data-end=\"2494\"><strong data-start=\"2303\" data-end=\"2354\">Cell Instruments' MST-01 Tester f\u00f6r medicinska sprutor<\/strong> erbjuder en helt\u00e4ckande l\u00f6sning. Den st\u00f6der b\u00e5de kraftbaserad och tryckbaserad provning, vilket \u00e4r perfekt f\u00f6r att s\u00e4kerst\u00e4lla \u00f6verensst\u00e4mmelse med ISO-standarder.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d3d2fd elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"8d3d2fd\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 l\u00e4ckagetest av sprutor\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d84a26e elementor-widget elementor-widget-heading\" data-id=\"d84a26e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Testf\u00f6rfarande f\u00f6r sprutl\u00e4ckage<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1a41478 e-grid e-con-full e-con e-child\" data-id=\"1a41478\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-51c8a4e elementor-widget elementor-widget-text-editor\" data-id=\"51c8a4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ol data-start=\"2526\" data-end=\"2787\"><li class=\"\" data-start=\"2526\" data-end=\"2603\"><p class=\"\" data-start=\"2529\" data-end=\"2603\">F\u00f6r in sprutan i en <strong data-start=\"2555\" data-end=\"2573\">Spruth\u00e5llare<\/strong> med st\u00e4ngningssystem p\u00e5 plats.<\/p><\/li><li class=\"\" data-start=\"2604\" data-end=\"2665\"><p class=\"\" data-start=\"2607\" data-end=\"2665\">Fyll p\u00e5 med destillerat vatten till 1\/3 till 2\/3 av den nominella volymen.<\/p><\/li><li class=\"\" data-start=\"2666\" data-end=\"2706\"><p class=\"\" data-start=\"2669\" data-end=\"2706\">Applicera ett tryck p\u00e5 110 kPa under 5 sekunder.<\/p><\/li><li class=\"\" data-start=\"2707\" data-end=\"2787\"><p class=\"\" data-start=\"2710\" data-end=\"2787\">Sl\u00e4pp trycket och <strong data-start=\"2731\" data-end=\"2764\">Inspektera f\u00f6r externa droppar<\/strong> eller att topplocket lossnar.<\/p><\/li><\/ol><p class=\"\" data-start=\"2789\" data-end=\"2867\">Denna metod replikerar \u00f6vertrycksscenarier och bekr\u00e4ftar t\u00e4tningens integritet.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5676ace elementor-widget elementor-widget-video\" data-id=\"5676ace\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=XHOmBV4js_E&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2614162 e-flex e-con-boxed e-con e-parent\" data-id=\"2614162\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-72ac59a elementor-widget elementor-widget-heading\" data-id=\"72ac59a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Testning Tolkning av resultaten<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70afec8 elementor-widget elementor-widget-text-editor\" data-id=\"70afec8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2904\" data-end=\"2921\">F\u00f6r att klara provet:<\/p><ul><li data-start=\"2924\" data-end=\"3001\"><strong data-start=\"2924\" data-end=\"2946\">Inga v\u00e4tskedroppar<\/strong> ska vara synliga runt spetslocket eller n\u00e5lskyddet.<\/li><li data-start=\"2924\" data-end=\"3001\"><span style=\"font-size: 16px;\">St\u00e4ngningen m\u00e5ste <\/span><strong style=\"font-size: 16px;\" data-start=\"3021\" data-end=\"3040\">f\u00f6rbli p\u00e5 plats<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3004\" data-end=\"3041\"><span style=\"font-size: 16px;\">Visuell inspektion bekr\u00e4ftar om en spruta \u00e4r godk\u00e4nd eller underk\u00e4nd.<\/span><\/li><\/ul><p class=\"\" data-start=\"3103\" data-end=\"3134\">Testrapporten b\u00f6r inneh\u00e5lla:<\/p><ul><li data-start=\"3137\" data-end=\"3162\">P\u00e5f\u00f6rt tryck eller kraft<\/li><li data-start=\"3137\" data-end=\"3162\">Antal testade prover<\/li><li data-start=\"3137\" data-end=\"3162\">Antal godk\u00e4nda eller underk\u00e4nda<\/li><li data-start=\"3137\" data-end=\"3162\">Eventuella avvikelser som observerats under testet<\/li><\/ul><p class=\"\" data-start=\"3259\" data-end=\"3336\">Korrekt dokumentation \u00e4r avg\u00f6rande f\u00f6r myndighetsrevisioner och kvalitetsuppf\u00f6ljning.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-87c6b33 elementor-widget elementor-widget-heading\" data-id=\"87c6b33\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">L\u00e4ckagetestare f\u00f6r f\u00f6rfylld spruta<small>--Mera applikationer<\/small><\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd20d14 elementor-widget elementor-widget-text-editor\" data-id=\"cd20d14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3408\" data-end=\"3534\"><strong data-start=\"3408\" data-end=\"3435\">Test av sprutl\u00e4ckage<\/strong> \u00e4r bara en aspekt av <strong data-start=\"3458\" data-end=\"3487\">testning av f\u00f6rfyllda sprutor<\/strong> under <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a>. Tillverkarna unders\u00f6ker ocks\u00e5:<\/p><ul><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"3537\" data-end=\"3567\">Kolvens glidmotst\u00e5nd<\/strong><\/a><\/li><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/syringes-needle-penetration-test-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-size: 16px;\" data-start=\"3570\" data-end=\"3598\">N\u00e5lens penetrationskraft<\/strong><\/a><\/li><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/needle-bonding-strength-test-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-size: 16px;\" data-start=\"3601\" data-end=\"3641\">Bindningsstyrka mellan n\u00e5l och nav<\/strong><\/a><\/li><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-size: 16px;\" data-start=\"3644\" data-end=\"3676\">Fasth\u00e5llning av kolv (utdragbar)<\/strong><\/a><\/li><\/ul><p class=\"\" data-start=\"3678\" data-end=\"3926\"><strong data-start=\"3678\" data-end=\"3688\">MST-01<\/strong> integrerar dessa funktioner i en enda, kompakt testenhet. Den m\u00f6jligg\u00f6r fullst\u00e4ndig mekanisk verifiering av <strong data-start=\"3796\" data-end=\"3833\">tomma sterila eng\u00e5ngssprutor<\/strong>som inte bara uppfyller ISO 11040-4 utan \u00e4ven <a href=\"https:\/\/www.pharmacopoeiatest.com\/sv\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"3880\" data-end=\"3894\">ISO 7886-1<\/strong><\/a>, <strong data-start=\"3896\" data-end=\"3908\">ISO 8537<\/strong>, och <strong data-start=\"3914\" data-end=\"3925\">USP 382<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1288b5d elementor-widget elementor-widget-heading\" data-id=\"1288b5d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Varf\u00f6r v\u00e4lja MST-01 f\u00f6r test av sprutl\u00e4ckage<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-601b24a elementor-widget elementor-widget-text-editor\" data-id=\"601b24a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4001\" data-end=\"4057\">Den <strong data-start=\"4005\" data-end=\"4038\">MST-01 Tester f\u00f6r medicinska sprutor<\/strong> sticker ut p\u00e5 grund av:<\/p><ul><li data-start=\"4060\" data-end=\"4110\"><strong data-start=\"4060\" data-end=\"4085\">Kapacitet f\u00f6r flera tester<\/strong> inb\u00e4ddad i en plattform<\/li><li data-start=\"4060\" data-end=\"4110\"><strong style=\"font-size: 16px;\" data-start=\"4113\" data-end=\"4138\">PLC-kontrollerat system<\/strong><span style=\"font-size: 16px;\"> och 7-tums peksk\u00e4rm<\/span><\/li><li data-start=\"4060\" data-end=\"4110\"><strong style=\"font-size: 16px;\" data-start=\"4164\" data-end=\"4209\">Precisionsstyrning av kraft och f\u00f6rskjutning<\/strong><\/li><li data-start=\"4060\" data-end=\"4110\"><strong style=\"font-size: 16px;\" data-start=\"4212\" data-end=\"4236\">\u00d6vervakning i realtid<\/strong><span style=\"font-size: 16px;\"> och inbyggd mikroskrivare<\/span><\/li><\/ul><p class=\"\" data-start=\"4264\" data-end=\"4549\">Denna m\u00e5ngsidighet s\u00e4kerst\u00e4ller noggrann, effektiv och reproducerbar l\u00e4ckagetestning av sprutor samtidigt som globala standarder uppfylls. Med anpassningsbara fixturer och programmerbara testuppst\u00e4llningar ger MST-01 en <strong data-start=\"4458\" data-end=\"4476\">kostnadseffektiva<\/strong> och <strong data-start=\"4481\" data-end=\"4498\">anv\u00e4ndarv\u00e4nlig<\/strong> l\u00f6sning f\u00f6r kvalitetskontrollteam inom l\u00e4kemedelsindustrin.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Leakage Testing ISO 11040-4 Annex G2 In the field of pharmaceutical and medical device manufacturing, syringe leakage testing is a critical quality assurance process. It ensures that prefilled syringes maintain sterility and do not leak during transport, storage, or use. To meet stringent regulatory expectations, manufacturers must follow international standards such as ISO 11040-4, [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2036","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/sv\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Syringe Leakage Testing ISO 11040-4 Annex G2 In the field of pharmaceutical and medical device manufacturing, syringe leakage testing is a critical quality assurance process. It ensures that prefilled syringes maintain sterility and do not leak during transport, storage, or use. To meet stringent regulatory expectations, manufacturers must follow international standards such as ISO 11040-4,&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2036","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/comments?post=2036"}],"version-history":[{"count":6,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2036\/revisions"}],"predecessor-version":[{"id":2055,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/posts\/2036\/revisions\/2055"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/media?parent=2036"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/categories?post=2036"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sv\/wp-json\/wp\/v2\/tags?post=2036"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}