{"id":2105,"date":"2025-05-07T06:56:33","date_gmt":"2025-05-07T06:56:33","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2105"},"modified":"2025-05-07T06:56:34","modified_gmt":"2025-05-07T06:56:34","slug":"lla-collar-torque-resistance","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/sl\/lla-collar-torque-resistance\/","title":{"rendered":"Odpornost na navor za ovratnik LLA"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2105\" class=\"elementor elementor-2105\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f46df2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f46df2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2444a elementor-widget elementor-widget-heading\" data-id=\"7b2444a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Odpornost na navor za ovratnik LLA<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edec19 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8edec19\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e4ea1f elementor-widget elementor-widget-heading\" data-id=\"0e4ea1f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Priloga G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3053d41 e-flex e-con-boxed e-con e-parent\" data-id=\"3053d41\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d4d20a elementor-widget elementor-widget-text-editor\" data-id=\"7d4d20a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"376\" data-end=\"978\">V farmacevtski proizvodnji je zagotavljanje mehanske celovitosti prednapolnjenih brizg klju\u010dnega pomena za varnost in u\u010dinkovitost izdelka. Eden klju\u010dnih dejavnikov te celovitosti je <strong data-start=\"567\" data-end=\"599\">Odpornost na navor ovratnika LLA<\/strong>, ki meri trdnost obro\u010da adapterja Luer Lock (LLA) pri navoru. Ta lastnost zagotavlja, da ovratnik prenese vrtilno silo, ko medicinsko osebje pritrdi pesto igle ali zdru\u017eljive priklju\u010dke. Izvedba tega preskusa v skladu z <em data-start=\"862\" data-end=\"875\">ISO 11040-4<\/em> in . <em data-start=\"880\" data-end=\"890\">Priloga G4<\/em> pomaga proizvajalcem izpolnjevati predpise in zagotavljati varne in funkcionalne izdelke.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0043965 elementor-widget elementor-widget-heading\" data-id=\"0043965\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Odpor na navor ovratnice LLA in to je pomembno<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef59016 elementor-widget elementor-widget-text-editor\" data-id=\"ef59016\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"985\" data-end=\"1456\"><strong data-start=\"1047\" data-end=\"1079\">Odpornost na navor ovratnika LLA<\/strong> se nana\u0161a na sposobnost obro\u010da Luer Lock na brizgalki, da se ob uporabi navora ne obrne ali zrahlja. Pri dejanski uporabi to simulira mehansko obremenitev, ki nastane, ko zdravnik priklju\u010di napravo, zdru\u017eljivo s klju\u010davnico Luer. Pomanjkljiva odpornost na navor lahko povzro\u010di uhajanje, nepravilno dajanje zdravila ali kontaminacijo - resna tveganja v klini\u010dnih okoljih.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77afa8a elementor-widget elementor-widget-heading\" data-id=\"77afa8a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standard za presku\u0161anje brizg - ISO 11040-4, Priloga G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f4cc74 e-con-full e-flex e-con e-child\" data-id=\"9f4cc74\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0879ad7 elementor-widget elementor-widget-text-editor\" data-id=\"0879ad7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1463\" data-end=\"1902\">Spletna stran <strong data-start=\"1525\" data-end=\"1540\">ISO 11040-4<\/strong> standard z naslovom <em data-start=\"1558\" data-end=\"1673\">Prednapolnjene injekcijske brizge - 4. del: Stekleni sodi za injiciranje in sterilizirane sestavljene brizge, pripravljene za polnjenje<\/em>, opisuje stroge preskusne metode za zagotavljanje zanesljivosti izdelka. <em data-start=\"1737\" data-end=\"1747\">Priloga G4<\/em> posebej podrobno opisuje metodo za ocenjevanje <strong data-start=\"1794\" data-end=\"1826\">Odpornost na navor ovratnika LLA<\/strong>zato je nepogre\u0161ljiv za proizvajalce, ki se ukvarjajo z <strong data-start=\"1882\" data-end=\"1901\">testiranje z brizgalko<\/strong>.<\/p><p class=\"\" data-start=\"1904\" data-end=\"1941\">Klju\u010dni poudarki iz Priloge G4 vklju\u010dujejo:<\/p><ul><li data-start=\"1944\" data-end=\"2066\"><strong data-start=\"1944\" data-end=\"1963\">Testno na\u010delo:<\/strong> Preveri, ali ovratnik LLA vzdr\u017ei navor med pritrditvijo standardnega sto\u017e\u010dastega nastavka 6% Luer.<\/li><li data-start=\"2069\" data-end=\"2129\"><strong data-start=\"2069\" data-end=\"2099\">Priporo\u010dena hitrost vzor\u010denja:<\/strong> 500 Hz za maksimalne meritve.<\/li><li data-start=\"2132\" data-end=\"2186\"><strong data-start=\"2132\" data-end=\"2160\">Standardna hitrost vrtenja:<\/strong> 20 vrtljajev na minuto ali po dogovoru.<\/li><li data-start=\"2189\" data-end=\"2255\"><strong data-start=\"2189\" data-end=\"2212\">Izhod meritev:<\/strong> Najve\u010dji navor ob za\u010detku gibanja ovratnice.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1ed627 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"d1ed627\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"236\" height=\"361\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp\" class=\"attachment-full size-full wp-image-2107\" alt=\"Odpornost na navor ovratnice LLA - presku\u0161anje z brizgalko po standardu ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp 236w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing-196x300.webp 196w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47df98e elementor-widget elementor-widget-heading\" data-id=\"47df98e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Preskusna oprema za odpornost na navor ovratnice LLA<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4baaf8e elementor-widget elementor-widget-text-editor\" data-id=\"4baaf8e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2262\" data-end=\"2400\">Za izvedbo preskusa so potrebni natan\u010dni instrumenti. Standardna nastavitev vklju\u010duje:<\/p><ul><li data-start=\"2403\" data-end=\"2556\"><strong data-start=\"2403\" data-end=\"2441\">Tester navora z napravo za vrtenje<\/strong>: mora biti sposoben zaznati najve\u010dji navor z lo\u010dljivostjo <strong data-start=\"2507\" data-end=\"2519\">0,05 Ncm<\/strong>, idealno obmo\u010dje je <strong data-start=\"2539\" data-end=\"2555\">do 35 Ncm<\/strong>.<\/li><li data-start=\"2559\" data-end=\"2630\"><strong data-start=\"2559\" data-end=\"2581\">Prijemalo za ovratnik LLA<\/strong>: Varno vpne ovratnik, ne da bi ga po\u0161kodoval.<\/li><li data-start=\"2633\" data-end=\"2737\"><strong data-start=\"2633\" data-end=\"2661\">Vrtljivo dr\u017ealo za brizgo<\/strong>: Omogo\u010da natan\u010dno in dosledno vrtenje brizge ali zaporke.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0058def elementor-widget elementor-widget-heading\" data-id=\"0058def\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vodnik po korakih za izvedbo testa<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e82ef56 elementor-widget elementor-widget-text-editor\" data-id=\"e82ef56\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2938\" data-end=\"3119\">Strokovnjaki za nadzor kakovosti lahko upo\u0161tevajo te korake, da zagotovijo natan\u010dno in standardizirano testiranje <strong data-start=\"3086\" data-end=\"3118\">Odpornost na navor ovratnika LLA<\/strong>:<\/p><ol><li data-start=\"3124\" data-end=\"3195\"><strong data-start=\"3124\" data-end=\"3134\">Vstavite<\/strong> sterilizirano sestavljeno brizgo vstavite v dr\u017ealo brizge.<\/li><li data-start=\"3199\" data-end=\"3231\"><strong data-start=\"3199\" data-end=\"3209\">Odstranite<\/strong> Ro\u010dno odstranite pokrov\u010dek konice.<\/li><li data-start=\"3235\" data-end=\"3297\"><strong data-start=\"3235\" data-end=\"3244\">Mount<\/strong> zategovalnik ovratnice LLA varno pritrdite na ovratnico LLA.<\/li><li data-start=\"3301\" data-end=\"3355\"><strong data-start=\"3301\" data-end=\"3309\">Zero<\/strong> celico navora za odpravo navora prednapetosti.<\/li><li data-start=\"3359\" data-end=\"3416\"><strong data-start=\"3359\" data-end=\"3366\">Nastavite<\/strong> hitrost vrtenja nastavite na 20 vrtljajev na minuto (ali kakor je primerno).<\/li><li data-start=\"3420\" data-end=\"3509\"><strong data-start=\"3420\" data-end=\"3432\">Za\u010detek<\/strong> test z vrtenjem brizge ali zapirala za 90\u00b0 v predvideni smeri.<\/li><li data-start=\"3513\" data-end=\"3568\"><strong data-start=\"3513\" data-end=\"3523\">Zapis<\/strong> najve\u010dji navor, ko se za\u010dne premikati ovratnica.<\/li><\/ol><p class=\"\" data-start=\"3570\" data-end=\"3675\">Ta vrednost navora odra\u017ea <strong data-start=\"3601\" data-end=\"3623\">najve\u010dja odpornost<\/strong> ki jih ponuja ovratnik LLA pod operativnimi obremenitvami.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d445bbc e-con-full e-flex e-con e-child\" data-id=\"d445bbc\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-defbeb6 e-con-full e-flex e-con e-child\" data-id=\"defbeb6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c54c92 elementor-widget elementor-widget-heading\" data-id=\"1c54c92\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Poro\u010danje o preskusih in nadzor kakovosti<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-669ef67 elementor-widget elementor-widget-text-editor\" data-id=\"669ef67\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3682\" data-end=\"3799\">V skladu s Prilogo G4 k standardu ISO 11040-4 mora iz\u010drpno poro\u010dilo o preskusu vsebovati:<\/p><ul><li data-start=\"3802\" data-end=\"3826\">Vrednosti najve\u010djega navora (Ncm)<\/li><li data-start=\"3829\" data-end=\"3849\">Hitrost vrtenja (vrtljaji na minuto)<\/li><li data-start=\"3852\" data-end=\"3876\">\u0160tevilo testiranih vzorcev<\/li><li data-start=\"3879\" data-end=\"3896\">Rezultati uspe\u0161no\/neuspe\u0161no<\/li><li data-start=\"3899\" data-end=\"3931\">Opombe o odstopanjih ali nepravilnostih<\/li><\/ul><p class=\"\" data-start=\"3933\" data-end=\"4059\">Ta dokumentacija zagotavlja sledljivost in skladnost, ki sta klju\u010dnega pomena za regulativne revizije in certificiranje izdaje izdelka.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb68c8a e-con-full e-flex e-con e-child\" data-id=\"cb68c8a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c067893 elementor-widget elementor-widget-heading\" data-id=\"c067893\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prednosti avtomatiziranega testiranja navora<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36ac35a elementor-widget elementor-widget-text-editor\" data-id=\"36ac35a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4066\" data-end=\"4277\">V podjetju Cell Instruments smo specializirani za precizne preskusne sisteme, vklju\u010dno s preizku\u0161evalniki navora, prilagojenimi za <strong data-start=\"4211\" data-end=\"4243\">Odpornost na navor ovratnika LLA<\/strong> ocenjevanja. Avtomatizacija izbolj\u0161uje:<\/p><ul><li data-start=\"4280\" data-end=\"4309\"><strong data-start=\"4280\" data-end=\"4309\">Ponovljivost meritev<\/strong><\/li><li data-start=\"4312\" data-end=\"4329\"><strong data-start=\"4312\" data-end=\"4329\">Natan\u010dnost podatkov<\/strong><\/li><li data-start=\"4332\" data-end=\"4358\"><strong data-start=\"4332\" data-end=\"4358\">Operativna u\u010dinkovitost<\/strong><\/li><li data-start=\"4361\" data-end=\"4385\"><strong data-start=\"4361\" data-end=\"4385\">Zagotavljanje skladnosti<\/strong><\/li><\/ul><p class=\"\" data-start=\"4387\" data-end=\"4527\">Prilagojene naprave in integracija programske opreme laboratorijem omogo\u010dajo racionalizacijo delovnih postopkov testiranja brizg, pri \u010demer strogo upo\u0161tevajo smernice ISO.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11ccf92 elementor-widget elementor-widget-text-editor\" data-id=\"11ccf92\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4984\" data-end=\"5514\">Razumevanje in izvajanje <strong data-start=\"5036\" data-end=\"5068\">Odpornost na navor ovratnika LLA<\/strong> test v skladu z <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5092\" data-end=\"5107\">ISO 11040-4<\/strong><\/a> in . <strong data-start=\"5112\" data-end=\"5124\">Priloga G4<\/strong> je bistvenega pomena za zagotavljanje kakovosti brizg. Ta preskus \u0161\u010diti pred mehanskimi okvarami med klini\u010dno uporabo in pomaga proizvajalcem ohranjati najvi\u0161je standarde varnosti bolnikov. Na spletni strani <strong data-start=\"5308\" data-end=\"5328\">Celi\u010dni instrumenti<\/strong>zagotavljamo najsodobnej\u0161e re\u0161itve za testiranje navora, ki so skladne z globalnimi standardi in potrebami industrije ter proizvajalcem brizg zagotavljajo zanesljive podatke in regulativno zaupanje.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Odpornost na navor obro\u010da LLA ISO 11040-4 Priloga G4 V farmacevtski proizvodnji je zagotavljanje mehanske celovitosti prednapolnjenih brizg klju\u010dnega pomena za varnost in u\u010dinkovitost izdelka. Eden klju\u010dnih dejavnikov te celovitosti je odpornost na navor na obro\u010dek LLA, ki meri trdnost obro\u010dka adapterja Luer Lock (LLA) pri navoru. Ta lastnost zagotavlja, da je ovratnik [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2105","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/sl\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/posts\/2105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/comments?post=2105"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/posts\/2105\/revisions"}],"predecessor-version":[{"id":2111,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/posts\/2105\/revisions\/2111"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/media?parent=2105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/categories?post=2105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/tags?post=2105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}