{"id":2087,"date":"2025-04-27T08:38:09","date_gmt":"2025-04-27T08:38:09","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2087"},"modified":"2025-04-27T08:47:19","modified_gmt":"2025-04-27T08:47:19","slug":"luer-lock-rings-pull-off-force-test","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/sl\/luer-lock-rings-pull-off-force-test\/","title":{"rendered":"Preskus sile odpiranja obro\u010dkov Luer Lock - ISO 11040-4, Priloga G3"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2087\" class=\"elementor elementor-2087\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a57182 e-flex e-con-boxed e-con e-parent\" data-id=\"7a57182\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-caf1aa9 elementor-widget elementor-widget-heading\" data-id=\"caf1aa9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Obro\u010dki Luer Lock Sila odpiranja<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27efcf2 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"27efcf2\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49edf54 elementor-widget elementor-widget-heading\" data-id=\"49edf54\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Priloga G3<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-03ddeb3 e-flex e-con-boxed e-con e-parent\" data-id=\"03ddeb3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ccea8f2 elementor-widget elementor-widget-text-editor\" data-id=\"ccea8f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"455\" data-end=\"1006\">V farmacevtski industriji in industriji medicinskih pripomo\u010dkov je <em data-start=\"531\" data-end=\"563\">obro\u010dki za zaklepanje luer s silo odpiranja<\/em> je klju\u010dni parameter za zagotavljanje zanesljivosti in varnosti prednapolnjenih brizg. Z ustreznim testiranjem se preveri varna pritrditev adapterja z zaklepom Luer (LLA), da se prepre\u010di nenamerno odlepitev med uporabo.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c963d8 elementor-widget elementor-widget-heading\" data-id=\"0c963d8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pomen sile odpiranja obro\u010dev Luer Lock<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee545a5 elementor-widget elementor-widget-text-editor\" data-id=\"ee545a5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1013\" data-end=\"1449\">Spletna stran <em data-start=\"1076\" data-end=\"1108\">obro\u010dki za zaklepanje luer s silo odpiranja<\/em> meri aksialno mo\u010d, ki je potrebna za lo\u010ditev sistema ovratnika LLA od cilindra brizge. Natan\u010dno testiranje zagotavlja, da brizga ohrani celovitost med rokovanjem, polnjenjem in dajanjem, kar zmanj\u0161uje tveganje okvare pripomo\u010dka. Regulativni standardi predpisujejo te preskuse za za\u0161\u010dito varnosti bolnikov in podporo trditvam o u\u010dinkovitosti izdelka.<\/p><p class=\"\" data-start=\"1451\" data-end=\"1734\">Za proizvajalce in agencije za nadzor kakovosti, zlasti tiste, ki delujejo na podro\u010dju medicine, farmacije in zdravstva, je obvladovanje tega preskusa bistvenega pomena. <strong data-start=\"1610\" data-end=\"1630\">Celi\u010dni instrumenti<\/strong> ponuja napredne re\u0161itve, ki izpolnjujejo te stroge zahteve z visoko natan\u010dnostjo in zanesljivostjo.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4912cb5 elementor-widget elementor-widget-heading\" data-id=\"4912cb5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Priloga G3 Zahteva<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9bf8207 elementor-widget elementor-widget-text-editor\" data-id=\"9bf8207\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1741\" data-end=\"2070\"><em data-start=\"1838\" data-end=\"1851\">ISO 11040-4<\/em> opredeljuje zahteve za steklene sod\u010dke za injiciranje in sterilizirane sestavljene brizge, pripravljene za polnjenje. Natan\u010dneje, <em data-start=\"1981\" data-end=\"2003\">ISO 11040-4 Priloga G3<\/em> podrobnosti o metodi merjenja <em data-start=\"2037\" data-end=\"2069\">obro\u010dki za zaklepanje luer s silo odpiranja<\/em>.<\/p><p class=\"\" data-start=\"2072\" data-end=\"2096\">V skladu s Prilogo G3:<\/p><ul data-start=\"2097\" data-end=\"2989\"><li class=\"\" data-start=\"2097\" data-end=\"2237\"><p class=\"\" data-start=\"2099\" data-end=\"2237\"><strong data-start=\"2099\" data-end=\"2112\">Na\u010delo<\/strong>: S preskusom se oceni, ali je sistem LLA odporen na dolo\u010deno osno silo odriva, ko je priklju\u010den na standardni priklju\u010dek luer.<\/p><\/li><li class=\"\" data-start=\"2238\" data-end=\"2444\"><p class=\"\" data-start=\"2240\" data-end=\"2444\"><strong data-start=\"2240\" data-end=\"2253\">Aparat<\/strong>: Potreben je univerzalni stroj za natezno in tla\u010dno testiranje, ki lahko deluje pri <strong data-start=\"2346\" data-end=\"2373\">preskusna hitrost 20 mm\/min<\/strong>. Obremenilna celica s tipi\u010dnim obmo\u010djem <strong data-start=\"2411\" data-end=\"2428\">10 N do 100 N<\/strong> je treba uporabiti.<\/p><\/li><li class=\"\" data-start=\"2445\" data-end=\"2524\"><p class=\"\" data-start=\"2447\" data-end=\"2524\"><strong data-start=\"2447\" data-end=\"2462\">Priprava<\/strong>: Preskusni vzorci morajo ustrezati pogojem proizvodnega procesa.<\/p><\/li><li class=\"\" data-start=\"2525\" data-end=\"2751\"><p class=\"\" data-start=\"2527\" data-end=\"2751\"><strong data-start=\"2527\" data-end=\"2540\">Postopek<\/strong>: Ko odstranite pokrov\u010dek konice, brizgalko namestite v dr\u017ealo, ne da bi na LLA izvajali predtlak. Naprava nato vle\u010de s konstantno hitrostjo, dokler se ovratnik LLA ne odlepi, pri \u010demer se zabele\u017ei najve\u010dja sila.<\/p><\/li><li class=\"\" data-start=\"2752\" data-end=\"2851\"><p class=\"\" data-start=\"2754\" data-end=\"2851\"><strong data-start=\"2754\" data-end=\"2765\">Rezultati<\/strong>: Najve\u010dja sila iz krivulje sila-premik predstavlja odrivno mo\u010d.<\/p><\/li><li class=\"\" data-start=\"2852\" data-end=\"2989\"><p class=\"\" data-start=\"2854\" data-end=\"2989\"><strong data-start=\"2854\" data-end=\"2871\">Dokumentacija<\/strong>: Poro\u010dilo mora vsebovati preskusno hitrost, najvi\u0161jo vrednost, \u0161tevilo vzorcev, pozitivne\/negativne rezultate in vsa opa\u017eena odstopanja.<\/p><\/li><\/ul><p class=\"\" data-start=\"2991\" data-end=\"3102\">Sledenje <em data-start=\"3001\" data-end=\"3023\">ISO 11040-4 Priloga G3<\/em> zagotavlja, da so rezultati zanesljivi, ponovljivi in mednarodno sprejeti.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd67e63 elementor-widget elementor-widget-heading\" data-id=\"cd67e63\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kako izvesti test sile odriva obro\u010dev Luer Lock<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec7a39c elementor-widget elementor-widget-text-editor\" data-id=\"ec7a39c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3109\" data-end=\"3263\">Izvedba natan\u010dnega <a href=\"https:\/\/www.pharmacopoeiatest.com\/sl\/luer-lock-rings-pull-off-force-test\/\"><em data-start=\"3193\" data-end=\"3225\">obro\u010dki za zaklepanje luer s silo odpiranja<\/em> test<\/a> vklju\u010duje ve\u010d pomembnih korakov:<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-08466dd e-con-full e-flex e-con e-child\" data-id=\"08466dd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-33a3c77 elementor-widget elementor-widget-text-editor\" data-id=\"33a3c77\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>1. Priprava vzorca<\/strong><\/p><ul><li data-start=\"3292\" data-end=\"3363\">Uporabite sterilizirane sestavljene brizge, ki odra\u017eajo proizvodne pogoje.<\/li><li data-start=\"3292\" data-end=\"3363\">Odstranite pokrov\u010dek konice, ne da bi obremenili sistem ovratnika LLA.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d451ca elementor-widget elementor-widget-text-editor\" data-id=\"5d451ca\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3427\" data-end=\"3452\"><strong>2. Nastavitev testa<\/strong><\/p><ul><li data-start=\"3455\" data-end=\"3551\">Brizgo namestite v <strong data-start=\"3480\" data-end=\"3498\">dr\u017ealo za brizgo<\/strong> in pritrdite ovratnik LLA v <strong data-start=\"3532\" data-end=\"3550\">naprava za prijemalo<\/strong>.<\/li><li data-start=\"3455\" data-end=\"3551\">Pazite, da med nastavljanjem ne pritiskate na ovratnik.<\/li><li data-start=\"3455\" data-end=\"3551\">Umerite merilno celico na \"ni\u010d\", ne da bi uporabili predhodno obremenitev.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-95882a3 e-con-full e-flex e-con e-child\" data-id=\"95882a3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b1efd9c elementor-widget elementor-widget-text-editor\" data-id=\"b1efd9c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3675\" data-end=\"3699\"><strong>Izvajanje testa<\/strong><\/p><ul><li>Hitrost stroja nastavite na <strong data-start=\"3727\" data-end=\"3740\">20 mm\/min<\/strong>.<\/li><li>Za\u010dnite test vle\u010denja in spremljajte razmerje med silo in premikom.<\/li><li>Zabele\u017eite najve\u010djo silo, ko se ovratnik LLA odlepi od brizge.<\/li><\/ul><p class=\"\" data-start=\"3875\" data-end=\"3902\"><strong data-start=\"3875\" data-end=\"3900\">Analiza rezultatov<\/strong><\/p><ul><li data-start=\"3905\" data-end=\"3964\">Dolo\u010dite najvi\u0161jo to\u010dko na grafu sile in premikanja.<\/li><li data-start=\"3905\" data-end=\"3964\">Primerjajte jo z dolo\u010denimi mejnimi vrednostmi in dolo\u010dite, ali je uspe\u0161no ali neuspe\u0161no.<\/li><li data-start=\"3905\" data-end=\"3964\">Dokumentirajte vse parametre, vklju\u010dno s koli\u010dinami vzorcev, napakami in odstopanji.<\/li><\/ul><p class=\"\" data-start=\"4110\" data-end=\"4222\">A <strong data-start=\"4112\" data-end=\"4139\">frekvenca vzor\u010denja 500 Hz<\/strong> je priporo\u010dljivo, da med testiranjem zajamete natan\u010dne najvi\u0161je meritve.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37beef7 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"37beef7\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"496\" height=\"500\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp\" class=\"attachment-full size-full wp-image-2089\" alt=\"Preskus sile odpiranja obro\u010dkov Luer Lock - ISO 11040-4, Priloga G3\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp 496w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-298x300.webp 298w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-150x150.webp 150w\" sizes=\"(max-width: 496px) 100vw, 496px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fe809e1 e-con-full e-flex e-con e-child\" data-id=\"fe809e1\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-517a11d e-con-full e-flex e-con e-child\" data-id=\"517a11d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-661f7f9 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"661f7f9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 testiranje pu\u0161\u010danja brizge\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-63b418a e-con-full e-flex e-con e-child\" data-id=\"63b418a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-45b4a2d elementor-widget elementor-widget-heading\" data-id=\"45b4a2d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Priporo\u010dena oprema za natan\u010dno testiranje<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef6391d elementor-widget elementor-widget-text-editor\" data-id=\"ef6391d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4229\" data-end=\"4441\">Na spletni strani <strong data-start=\"4281\" data-end=\"4301\">Celi\u010dni instrumenti<\/strong>smo specializirani za zagotavljanje <strong data-start=\"4330\" data-end=\"4375\">univerzalni natezni in tla\u010dni preizku\u0161evalniki<\/strong> po meri za aplikacije za testiranje z brizgalko. Na\u0161i sistemi ponujajo:<\/p><ul data-start=\"4442\" data-end=\"4731\"><li class=\"\" data-start=\"4442\" data-end=\"4503\"><p class=\"\" data-start=\"4444\" data-end=\"4503\">Visokofrekven\u010dno vzor\u010denje (do 500 Hz) za najve\u010djo natan\u010dnost.<\/p><\/li><li class=\"\" data-start=\"4504\" data-end=\"4582\"><p class=\"\" data-start=\"4506\" data-end=\"4582\">Po meri izdelana dr\u017eala za brizge in prijemala LLA, skladna s specifikacijami ISO.<\/p><\/li><li class=\"\" data-start=\"4583\" data-end=\"4658\"><p class=\"\" data-start=\"4585\" data-end=\"4658\">Obremenilne celice so primerne za razli\u010dne preskusne sile med 10 N in 100 N.<\/p><\/li><li class=\"\" data-start=\"4659\" data-end=\"4731\"><p class=\"\" data-start=\"4661\" data-end=\"4731\">Intuitivna programska oprema za popolno sledljivost parametrov in enostavno poro\u010danje.<\/p><\/li><\/ul><p class=\"\" data-start=\"4733\" data-end=\"4901\">Na\u0161e re\u0161itve zagotavljajo skladnost z <em data-start=\"4773\" data-end=\"4786\">ISO 11040-4<\/em> in pomagajo zagotavljati najvi\u0161jo kakovost izdelkov za na\u0161e stranke v farmacevtski industriji in industriji medicinskih pripomo\u010dkov.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d05f85d elementor-widget elementor-widget-text-editor\" data-id=\"d05f85d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4908\" data-end=\"5324\">Razumevanje in natan\u010dno merjenje <em data-start=\"4968\" data-end=\"5000\">obro\u010dki za zaklepanje luer s silo odpiranja<\/em> v skladu z <em data-start=\"5014\" data-end=\"5036\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Priloga G3<\/em> je klju\u010dnega pomena za zagotavljanje varnosti in zanesljivosti brizge. Z upo\u0161tevanjem pravilnih metod in uporabo skladnih, zelo natan\u010dnih testnih instrumentov iz <strong data-start=\"5187\" data-end=\"5207\">Celi\u010dni instrumenti<\/strong>, lahko ekipe za nadzor kakovosti z gotovostjo preverijo delovanje izdelka, izpolnijo regulativne standarde in za\u0161\u010ditijo kon\u010dne uporabnike.<\/p><p class=\"\" data-start=\"5326\" data-end=\"5511\">\u010ce potrebujete pomo\u010d pri izbiri ali prilagoditvi prave opreme za testiranje za potrebe testiranja z brizgalko, <strong data-start=\"5437\" data-end=\"5471\">\u0161e danes stopite v stik z dru\u017ebo Cell Instruments<\/strong> in si oglejte na\u0161o celotno paleto re\u0161itev.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Sila izvleka obro\u010dkov Luer Lock ISO 11040-4 Priloga G3 V farmacevtski industriji in industriji medicinskih pripomo\u010dkov je sila izvleka obro\u010dkov Luer Lock klju\u010dni parameter za zagotavljanje zanesljivosti in varnosti prednapolnjenih brizg. Z ustreznim presku\u0161anjem se preveri varna pritrditev adapterja za zaklep luer (LLA), da se prepre\u010di nenamerno odlepitev med uporabo. Pomembnost [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2087","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/sl\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Lock Rings Pull-Off Force ISO 11040-4 Annex G3 In the pharmaceutical and medical device industries, the luer lock rings pull-off force is a critical parameter to ensure the reliability and safety of prefilled syringes. Proper testing verifies the secure attachment of the luer lock adaptor (LLA) to prevent accidental detachment during use. Importance of&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/posts\/2087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/comments?post=2087"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/posts\/2087\/revisions"}],"predecessor-version":[{"id":2101,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/posts\/2087\/revisions\/2101"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/media?parent=2087"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/categories?post=2087"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sl\/wp-json\/wp\/v2\/tags?post=2087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}