{"id":2658,"date":"2026-08-13T00:08:37","date_gmt":"2026-08-13T00:08:37","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2658"},"modified":"2026-08-13T00:08:40","modified_gmt":"2026-08-13T00:08:40","slug":"tubing-stiffness-tester-for-iso-9626","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/sk\/tubing-stiffness-tester-for-iso-9626\/","title":{"rendered":"Pr\u00edstroj na meranie tuhosti hadi\u010diek: Sk\u00fa\u0161ka tuhosti zdravotn\u00edckych hadi\u010diek pod\u013ea normy ISO 9626"},"content":{"rendered":"<h2 class=\"wp-block-heading\">\u010co je to pr\u00edstroj na meranie tuhosti had\u00edc?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>pr\u00edstroj na meranie tuhosti had\u00edc<\/strong> meria odolnos\u0165 zdravotn\u00edckych hadi\u010diek vo\u010di deform\u00e1cii pri p\u00f4soben\u00ed ur\u010denej sily. V pr\u00edpade hadi\u010diek pre injek\u010dn\u00e9 ihly a in\u00fdch zdravotn\u00edckych hadi\u010diek m\u00e1 tuhos\u0165 priamy vplyv na ohybnos\u0165, vlastnosti pri zav\u00e1dzan\u00ed, mechanick\u00fa spo\u013eahlivos\u0165 a bezpe\u010dnos\u0165. T\u00e1to <strong>TS-01 Pr\u00edstroj na meranie tuhosti had\u00edc<\/strong> vyv\u00edja kontrolovan\u00fa silu smeruj\u00facu nadol na stred podopretej vzorky r\u00farky a meria v\u00fdsledn\u00e9 jej vych\u00fdlenie. Tento pr\u00edstup k sk\u00fa\u0161aniu podporuje <strong>sk\u00fa\u0161anie tuhosti zdravotn\u00edckych hadi\u010diek<\/strong> v s\u00falade s <strong>ISO 9626<\/strong> a <strong>GB\/T 18457<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image aligncenter uagb-block-f73b64ff wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" srcset=\"\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Tubing-Stiffness-Tester: ISO-9626-Medical-Tubing-Stiffness-Test.webp\" alt=\"Pr\u00edstroj na meranie tuhosti hadi\u010diek: Sk\u00fa\u0161ka tuhosti zdravotn\u00edckych hadi\u010diek pod\u013ea normy ISO 9626\" class=\"uag-image-2661\" width=\"428\" height=\"428\" title=\"Pr\u00edstroj na meranie tuhosti hadi\u010diek: Sk\u00fa\u0161ka tuhosti zdravotn\u00edckych hadi\u010diek pod\u013ea normy ISO 9626\" role=\"img\" data-srcset=\"\"\/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Pre\u010do je tuhos\u0165 hadi\u010diek d\u00f4le\u017eit\u00e1 pre zdravotn\u00edcke pom\u00f4cky?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Lek\u00e1rske hadi\u010dky musia dosiahnu\u0165 primeran\u00fa rovnov\u00e1hu medzi <strong>sila a pru\u017enos\u0165<\/strong>. Ak je hadica pr\u00edli\u0161 ohybn\u00e1, m\u00f4\u017ee sa pri manipul\u00e1cii a pou\u017e\u00edvan\u00ed ohn\u00fa\u0165, zdeformova\u0165 alebo po\u0161kodi\u0165. Ak je naopak pr\u00edli\u0161 tuh\u00e1, m\u00f4\u017ee ma\u0165 nedostato\u010dn\u00fa ohybnos\u0165 a za ur\u010dit\u00fdch podmienok m\u00f4\u017ee by\u0165 n\u00e1chylnej\u0161ia na lom z krehkosti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pre v\u00fdrobcov zdravotn\u00edckych pom\u00f4cok m\u00f4\u017ee testovanie tuhosti hadi\u010diek pom\u00f4c\u0165 pri hodnoten\u00ed:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Odolnos\u0165 vo\u010di deform\u00e1cii pri za\u0165a\u017een\u00ed<\/li>\n\n\n\n<li>Flexibilita a mechanick\u00e9 vlastnosti<\/li>\n\n\n\n<li>Konzistentnos\u0165 medzi v\u00fdrobn\u00fdmi \u0161ar\u017eami<\/li>\n\n\n\n<li>Vhodnos\u0165 hadi\u010diek pre lek\u00e1rske \u00fa\u010dely<\/li>\n\n\n\n<li>S\u00falad s platn\u00fdmi \u0161pecifik\u00e1ciami a normami<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Preto je kontrolovan\u00e9 <strong>sk\u00fa\u0161ka tuhosti hadi\u010diek zdravotn\u00edckych pom\u00f4cok<\/strong> poskytuje u\u017eito\u010dn\u00e9 mechanick\u00e9 \u00fadaje pre v\u00fdber materi\u00e1lu, riadenie v\u00fdrobn\u00e9ho procesu, vstupn\u00fa kontrolu a z\u00e1vere\u010dn\u00e9 overenie kvality.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ako funguje pr\u00edstroj na meranie tuhosti had\u00edc?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Z\u00e1kladn\u00fd princ\u00edp je jednoduch\u00fd. Trubica ur\u010denej d\u013a\u017eky je <strong>podopren\u00e9 na oboch koncoch<\/strong>, pri\u010dom na jeho stred p\u00f4sob\u00ed kontrolovan\u00e1 sila. Pr\u00edstroj n\u00e1sledne meria, o ko\u013eko sa hadica ohne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zariadenie TS-01 vyu\u017e\u00edva na vykonanie tohto merania sn\u00edma\u010d za\u0165a\u017eenia a \u0161peci\u00e1lny piest. Piest p\u00f4sob\u00ed na hadicu vertik\u00e1lnou silou. Jeho spodn\u00fd koniec obsahuje <strong>konfigur\u00e1cia s tup\u00fdm klinom, pri\u010dom povrchy s\u00fa navz\u00e1jom naklonen\u00e9 pod uhlom 60\u00b0<\/strong>, spolu s valcovitou plochou s polomerom 1 mm a d\u013a\u017ekou najmenej 5 mm.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Syst\u00e9m m\u00f4\u017ee vyvin\u00fa\u0165 silu a\u017e <strong>60 N<\/strong> s presnos\u0165ou sily <strong>\u00b10,01 N<\/strong>, pri\u010dom priehyb potrubia je mo\u017en\u00e9 zmera\u0165 na <strong>0,01 mm<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Z\u00e1kladn\u00fd vz\u0165ah mo\u017eno koncep\u010dne vyjadri\u0165 takto:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P\u00f4sobiaca sila \u2192 Deform\u00e1cia hadice \u2192 Hodnotenie tuhosti<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Men\u0161ie prehnutie pri rovnakej p\u00f4sobiacej sile vo v\u0161eobecnosti sved\u010d\u00ed o v\u00e4\u010d\u0161ej odolnosti vo\u010di deform\u00e1cii, zatia\u013e \u010do v\u00e4\u010d\u0161ie prehnutie nazna\u010duje, \u017ee vzorka hadice je pru\u017enej\u0161ia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sk\u00fa\u0161anie tuhosti had\u00edc pod\u013ea normy ISO 9626<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>ISO 9626<\/strong> predstavuje d\u00f4le\u017eit\u00fd referen\u010dn\u00fd dokument pre mechanick\u00e9 po\u017eiadavky a sk\u00fa\u0161anie ihlov\u00fdch r\u00farok z nehrdzavej\u00facej ocele pou\u017e\u00edvan\u00fdch pri v\u00fdrobe zdravotn\u00edckych pom\u00f4cok. Poskytuje \u0161tandardizovan\u00fd r\u00e1mec na hodnotenie vlastnost\u00ed r\u00farok, vr\u00e1tane mechanick\u00fdch charakterist\u00edk relevantn\u00fdch pre ich zam\u00fd\u0161\u013ean\u00e9 pou\u017eitie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pri vykon\u00e1van\u00ed <strong>Sk\u00fa\u0161anie tuhosti had\u00edc pod\u013ea normy ISO 9626<\/strong>, je nevyhnutn\u00e9 riadi\u0165 sk\u00fa\u0161obn\u00fa silu, podoprenie vzorky, polohu za\u0165a\u017eenia a meranie deform\u00e1cie. Pou\u017eit\u00edm \u0161pecializovan\u00e9ho <strong>pr\u00edstroj na meranie tuhosti had\u00edc<\/strong> pom\u00e1ha laborat\u00f3ri\u00e1m udr\u017eiava\u0165 konzistentn\u00e9 podmienky testovania a zni\u017eova\u0165 odch\u00fdlky sp\u00f4soben\u00e9 obsluhou.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>GB\/T 18457<\/strong> je \u010fal\u0161ia platn\u00e1 norma pre ihlov\u00e9 r\u00farky z nehrdzavej\u00facej ocele a m\u00f4\u017ee sl\u00fa\u017ei\u0165 ako referen\u010dn\u00fd dokument pre pr\u00edslu\u0161n\u00e9 po\u017eiadavky na sk\u00fa\u0161anie.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Polo\u017eka<\/th><th class=\"has-text-align-center\" data-align=\"center\">Funkcie modelu TS-01<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Platn\u00e9 normy<\/td><td class=\"has-text-align-center\" data-align=\"center\">ISO 9626, GB\/T 18457<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Maxim\u00e1lna kon\u0161tantn\u00e1 sila<\/td><td class=\"has-text-align-center\" data-align=\"center\">60 N alebo pod\u013ea potreby<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Presnos\u0165 sily<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b10,01 N<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Presnos\u0165 vych\u00fdlenia<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,01 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Testovacia r\u00fdchlos\u0165<\/td><td class=\"has-text-align-center\" data-align=\"center\">1\u2013500 mm\/min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Ovl\u00e1danie<\/td><td class=\"has-text-align-center\" data-align=\"center\">PLC<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Prev\u00e1dzka<\/td><td class=\"has-text-align-center\" data-align=\"center\">7-palcov\u00fd dotykov\u00fd displej HMI<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Nap\u00e1janie<\/td><td class=\"has-text-align-center\" data-align=\"center\">110\u2013220 V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Ako sa vykon\u00e1va sk\u00fa\u0161ka tuhosti had\u00edc?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Typick\u00fd postup testovania zah\u0155\u0148a nasleduj\u00face kroky:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Pripravte vzorku<\/strong> v s\u00falade s platn\u00fdmi po\u017eiadavkami na sk\u00fa\u0161anie.<\/li>\n\n\n\n<li><strong>Umiestnite hadicu<\/strong> na up\u00ednacom zariaden\u00ed so stanovenou d\u013a\u017ekou sk\u00fa\u0161ky.<\/li>\n\n\n\n<li><strong>Vyrovnajte piest<\/strong> s stredom hadice.<\/li>\n\n\n\n<li><strong>Nastavte parametre testu<\/strong>, vr\u00e1tane sily alebo r\u00fdchlosti sk\u00fa\u0161ky.<\/li>\n\n\n\n<li><strong>P\u00f4sobte silou smerom nadol<\/strong> cez sn\u00edma\u010d za\u0165a\u017eenia a piest.<\/li>\n\n\n\n<li><strong>Meranie priehybu hadice<\/strong> po\u010das na\u010d\u00edtavania.<\/li>\n\n\n\n<li><strong>Zaznamenejte v\u00fdsledok testu<\/strong> na \u00fa\u010dely hodnotenia a porovnania kvality.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Pr\u00edstroj TS-01 sa po vykonan\u00ed testu automaticky vr\u00e1ti do v\u00fdchodiskovej polohy, \u010do m\u00f4\u017ee zv\u00fd\u0161i\u0165 efekt\u00edvnos\u0165 testovania v pr\u00edpadoch, ke\u010f laborat\u00f3ri\u00e1 potrebuj\u00fa vyhodnoti\u0165 viacero vzoriek.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ak\u00e9 zariadenia sa pou\u017e\u00edvaj\u00fa na testovanie tuhosti zdravotn\u00edckych hadi\u010diek?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u0160pecializovan\u00fd <strong>pr\u00edstroj na meranie tuhosti had\u00edc<\/strong> zvy\u010dajne sa sklad\u00e1 z riaden\u00e9ho sk\u00fa\u0161obn\u00e9ho r\u00e1mu, syst\u00e9mu merania za\u0165a\u017eenia, piestu, dr\u017eiaka sk\u00fa\u0161obn\u00e9ho telesa a softv\u00e9ru alebo rozhrania na nastavenie a zaznamen\u00e1vanie sk\u00fa\u0161obn\u00fdch podmienok.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Model TS-01 obsahuje:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Prev\u00e1dzka riaden\u00e1 PLC<\/strong><\/li>\n\n\n\n<li><strong>7-palcov\u00fd dotykov\u00fd displej HMI<\/strong><\/li>\n\n\n\n<li><strong>Presn\u00e1 gu\u013e\u00f4\u010dkov\u00e1 vodiaca skrutka<\/strong><\/li>\n\n\n\n<li><strong>Variabiln\u00e1 testovacia r\u00fdchlos\u0165<\/strong><\/li>\n\n\n\n<li><strong>Ochrana proti pre\u0165a\u017eeniu<\/strong><\/li>\n\n\n\n<li><strong>Funkcia automatick\u00e9ho n\u00e1vratu<\/strong><\/li>\n\n\n\n<li><strong>Mikrotla\u010diare\u0148<\/strong><\/li>\n\n\n\n<li>Viacn\u00e1sobn\u00e9 up\u00ednacie zariadenia na sk\u00fa\u0161ky s p\u00f4soben\u00edm sily smerom nadol<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Tieto funkcie umo\u017e\u0148uj\u00fa laborat\u00f3ri\u00e1m vytvori\u0165 opakovate\u013en\u00e9 podmienky testovania a z\u00e1rove\u0148 zjednodu\u0161uj\u00fa be\u017en\u00fa prev\u00e1dzku.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pre\u010do pou\u017e\u00edva\u0165 \u0161pecializovan\u00fd pr\u00edstroj na meranie tuhosti had\u00edc?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ru\u010dn\u00e9 merania deform\u00e1cie m\u00f4\u017eu sp\u00f4sobi\u0165 odch\u00fdlky v za\u0165a\u017eovacej sile, umiestnen\u00ed vzorky a presnosti merania. \u0160pecializovan\u00fd pr\u00edstroj zabezpe\u010duje kontrolovan\u00e9 mechanick\u00e9 za\u0165a\u017eenie a digit\u00e1lne meranie, v\u010faka \u010domu je mo\u017en\u00e9 v\u00fdsledky \u013eah\u0161ie reprodukova\u0165 a porovn\u00e1va\u0165.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pre laborat\u00f3ri\u00e1, ktor\u00e9 pracuj\u00fa s <strong>sk\u00fa\u0161anie tuhosti zdravotn\u00edckych hadi\u010diek<\/strong>, medzi hlavn\u00e9 v\u00fdhody patria:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Riaden\u00e9 p\u00f4sobenie sily<\/strong><\/li>\n\n\n\n<li><strong>Presn\u00e9 meranie priehybu<\/strong><\/li>\n\n\n\n<li><strong>Opakovate\u013en\u00e9 testovacie podmienky<\/strong><\/li>\n\n\n\n<li><strong>Nastavite\u013en\u00e1 r\u00fdchlos\u0165 testovania<\/strong><\/li>\n\n\n\n<li><strong>Testovanie zameran\u00e9 na normy<\/strong><\/li>\n\n\n\n<li><strong>Efekt\u00edvna rutinn\u00e1 kontrola kvality<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Zariadenie TS-01 podporuje ako \u0161tandardn\u00e9 po\u017eiadavky na testovanie, tak aj individu\u00e1lne po\u017eiadavky na testovanie, pri\u010dom pon\u00faka maxim\u00e1lnu silu 60 N a konfigurovate\u013en\u00e9 testovacie podmienky.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Z\u00e1ver<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tuhos\u0165 hadi\u010diek je d\u00f4le\u017eitou mechanickou vlastnos\u0165ou zdravotn\u00edckych hadi\u010diek, preto\u017ee ovplyv\u0148uje ich ohybnos\u0165, odolnos\u0165 vo\u010di deform\u00e1cii a funk\u010dn\u00fa spo\u013eahlivos\u0165. A <strong>pr\u00edstroj na meranie tuhosti had\u00edc<\/strong> poskytuje kontrolovan\u00fa met\u00f3du p\u00f4sobenia sily na vzorku r\u00farky umiestnen\u00fa v podper\u00e1ch a merania jej priehybu. S podporou pre <strong><a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noreferrer noopener\">ISO 9626<\/a><\/strong> a <strong>GB\/T 18457<\/strong>, zariadenie TS-01 je ur\u010den\u00e9 pre laborat\u00f3ri\u00e1 a v\u00fdrobcov, ktor\u00ed sa zaoberaj\u00fa hodnoten\u00edm tuhosti zdravotn\u00edckych hadi\u010diek, kontrolou kvality, v\u00fdvojom materi\u00e1lov a kontrolou v\u00fdroby.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Str\u00e1nka <strong>TS-01 Pr\u00edstroj na meranie tuhosti had\u00edc<\/strong> zabezpe\u010duje kontrolovan\u00e9 p\u00f4sobenie sily, presn\u00e9 meranie deform\u00e1cie a flexibiln\u00e9 nastavenia sk\u00fa\u0161ok pre be\u017en\u00e9 laborat\u00f3rne testovanie. Ak sa va\u0161a aplik\u00e1cia t\u00fdka noriem ISO 9626, GB\/T 18457, sk\u00fa\u0161ok tuhosti zdravotn\u00edckych hadi\u010diek alebo \u0161pecializovan\u00e9ho hodnotenia hadi\u010diek, <strong>Mobiln\u00e9 n\u00e1stroje <\/strong>m\u00f4\u017eeme poskytn\u00fa\u0165 vhodn\u00e9 testovacie zariadenia, up\u00ednacie pr\u00edpravky a testovacie rie\u0161enia na mieru.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>\u010co je to tester tuhosti hadi\u010diek? Tester tuhosti hadi\u010diek meria odolnos\u0165 zdravotn\u00edckych hadi\u010diek vo\u010di deform\u00e1cii pri p\u00f4soben\u00ed \u0161pecifikovanej sily. V pr\u00edpade hadi\u010diek pre injek\u010dn\u00e9 ihly a in\u00fdch zdravotn\u00edckych hadi\u010diek m\u00e1 tuhos\u0165 priamy vplyv na ohybnos\u0165, vlastnosti pri zav\u00e1dzan\u00ed, mechanick\u00fa spo\u013eahlivos\u0165 a bezpe\u010dnos\u0165. Pr\u00edstroj na meranie tuhosti hadi\u010diek TS-01 p\u00f4sob\u00ed kontrolovanou silou smerom nadol na stred [\u2026]<\/p>","protected":false},"author":5,"featured_media":2661,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2658","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Tubing-Stiffness-Tester\uff1aISO-9626-Medical-Tubing-Stiffness-Test.webp",600,600,false],"thumbnail":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Tubing-Stiffness-Tester\uff1aISO-9626-Medical-Tubing-Stiffness-Test-150x150.webp",150,150,true],"medium":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Tubing-Stiffness-Tester\uff1aISO-9626-Medical-Tubing-Stiffness-Test-300x300.webp",300,300,true],"medium_large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Tubing-Stiffness-Tester\uff1aISO-9626-Medical-Tubing-Stiffness-Test.webp",600,600,false],"large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Tubing-Stiffness-Tester\uff1aISO-9626-Medical-Tubing-Stiffness-Test.webp",600,600,false],"1536x1536":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Tubing-Stiffness-Tester\uff1aISO-9626-Medical-Tubing-Stiffness-Test.webp",600,600,false],"2048x2048":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Tubing-Stiffness-Tester\uff1aISO-9626-Medical-Tubing-Stiffness-Test.webp",600,600,false],"trp-custom-language-flag":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Tubing-Stiffness-Tester\uff1aISO-9626-Medical-Tubing-Stiffness-Test-12x12.webp",12,12,true]},"uagb_author_info":{"display_name":"Editor","author_link":"https:\/\/www.pharmacopoeiatest.com\/sk\/author\/editor\/"},"uagb_comment_info":0,"uagb_excerpt":"What Is a Tubing Stiffness Tester? A tubing stiffness tester measures the resistance of medical tubing to deformation under a specified force. For hypodermic needle tubing and other medical tubing, stiffness directly affects flexibility, insertion performance, mechanical reliability, and safety. The TS-01 Tubing Stiffness Tester applies a controlled downward force to the center of a&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/posts\/2658","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/comments?post=2658"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/posts\/2658\/revisions"}],"predecessor-version":[{"id":2664,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/posts\/2658\/revisions\/2664"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/media\/2661"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/media?parent=2658"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/categories?post=2658"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/tags?post=2658"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}