{"id":2610,"date":"2026-05-07T08:15:19","date_gmt":"2026-05-07T08:15:19","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2610"},"modified":"2026-05-07T08:46:47","modified_gmt":"2026-05-07T08:46:47","slug":"iso-8537","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/sk\/iso-8537\/","title":{"rendered":"ISO 8537"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2610\" class=\"elementor elementor-2610\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0662493 e-flex e-con-boxed e-con e-parent\" data-id=\"0662493\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fc37773 elementor-widget elementor-widget-heading\" data-id=\"fc37773\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8537 <br><small><small>Testovanie funk\u010dnosti inzul\u00ednovej injek\u010dnej strieka\u010dky<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-25d7b19 e-con-full e-flex e-con e-child\" data-id=\"25d7b19\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d257432 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"d257432\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"314\" data-end=\"683\">Norma ISO 8537 stanovuje po\u017eiadavky na v\u00fdkonnos\u0165 a sk\u00fa\u0161anie pre <strong data-start=\"378\" data-end=\"417\">steriln\u00e9 inzul\u00ednov\u00e9 injek\u010dn\u00e9 strieka\u010dky na jedno pou\u017eitie<\/strong>, s ihlami alebo bez nich. Norma sa zameriava na bezpe\u010dnos\u0165 injek\u010dn\u00fdch strieka\u010diek, ich funk\u010dnos\u0165, tesniace vlastnosti, presnos\u0165 d\u00e1vkovania a prev\u00e1dzkov\u00fa spo\u013eahlivos\u0165. V\u00fdrobcovia a laborat\u00f3ri\u00e1 zabezpe\u010duj\u00face kontrolu kvality vyu\u017e\u00edvaj\u00fa normu ISO 8537 na overenie, \u010di injek\u010dn\u00e9 strieka\u010dky funguj\u00fa konzistentne po\u010das klinick\u00e9ho pou\u017e\u00edvania.<\/p><p data-start=\"685\" data-end=\"1021\">Pre v\u00fdrobcov injek\u010dn\u00fdch strieka\u010diek znamen\u00e1 dodr\u017eiavanie normy ISO 8537 zv\u00fd\u0161enie spo\u013eahlivosti v\u00fdrobkov, podporu pri pod\u00e1van\u00ed \u017eiadost\u00ed o registr\u00e1ciu a zn\u00ed\u017eenie riz\u00edk spojen\u00fdch s netesnos\u0165ou, poruchou piestu alebo nepresn\u00fdm d\u00e1vkovan\u00edm. Laborat\u00f3ri\u00e1m zabezpe\u010duj\u00facim kontrolu kvality t\u00e1to norma poskytuje validovan\u00e9 postupy na hodnotenie v\u00fdkonnosti injek\u010dn\u00fdch strieka\u010diek v kontrolovan\u00fdch podmienkach.<\/p><p data-start=\"1023\" data-end=\"1207\">Ke\u010f\u017ee inzul\u00ednov\u00e9 injek\u010dn\u00e9 strieka\u010dky vy\u017eaduj\u00fa presn\u00e9 d\u00e1vkovanie a spo\u013eahliv\u00e9 tesnenie, <strong data-start=\"1105\" data-end=\"1138\">testovanie funk\u010dnosti injek\u010dnej strieka\u010dky<\/strong> zohr\u00e1va k\u013e\u00fa\u010dov\u00fa \u00falohu v priebehu cel\u00e9ho v\u00fdvoja a v\u00fdroby produktu.<\/p><p data-start=\"1209\" data-end=\"1536\">Spolo\u010dnos\u0165 Cell Instruments pon\u00faka \u0161pecializovan\u00e9 testovacie syst\u00e9my ur\u010den\u00e9 pre v\u00fdrobcov injek\u010dn\u00fdch strieka\u010diek, laborat\u00f3ri\u00e1 zaoberaj\u00face sa zdravotn\u00edckymi pom\u00f4ckami a t\u00edmy zodpovedn\u00e9 za kvalitu farmaceutick\u00fdch obalov. Tieto pr\u00edstroje umo\u017e\u0148uj\u00fa automatick\u00e9 meranie sily, hodnotenie tesnosti vo v\u00e1kuu, testovanie tesnosti a anal\u00fdzu m\u0155tveho priestoru v s\u00falade s metodikami normy ISO 8537.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b939f5 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"5b939f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"630\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes.webp\" class=\"attachment-full size-full wp-image-2613\" alt=\"ISO 8537 \u2013 Sk\u00fa\u0161anie funk\u010dnosti inzul\u00ednov\u00fdch injek\u010dn\u00fdch strieka\u010diek\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes.webp 500w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes-238x300.webp 238w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes-10x12.webp 10w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77936bb elementor-widget elementor-widget-heading\" data-id=\"77936bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sk\u00fa\u0161anie funk\u010dnosti injek\u010dn\u00fdch strieka\u010diek pod\u013ea normy ISO 8537<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e0637a3 e-grid e-con-full e-con e-child\" data-id=\"e0637a3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d71bda6 elementor-widget elementor-widget-text-editor\" data-id=\"d71bda6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1586\" data-end=\"1769\">Norma ISO 8537 zah\u0155\u0148a viacero hodnoten\u00ed v\u00fdkonnosti, ktor\u00e9 ur\u010duj\u00fa, \u010di je injek\u010dn\u00e1 strieka\u010dka schopn\u00e1 bezpe\u010dnej a presnej prev\u00e1dzky po\u010das ods\u00e1vania a vstrekovania. Norma zah\u0155\u0148a sk\u00fa\u0161ky:<\/p><ul data-start=\"1771\" data-end=\"1938\"><li data-section-id=\"1oxsryt\" data-start=\"1771\" data-end=\"1802\">\u00danik vzduchu po\u010das ods\u00e1vania<\/li><li data-section-id=\"b62ksi\" data-start=\"1803\" data-end=\"1837\">\u00danik kvapaliny pri stla\u010den\u00ed<\/li><li data-section-id=\"143ln9z\" data-start=\"1838\" data-end=\"1862\">P\u00f4sobiaca sila piesta<\/li><li data-section-id=\"1trb4xg\" data-start=\"1863\" data-end=\"1879\">Neporu\u0161enos\u0165 tesnenia<\/li><li data-section-id=\"77dvwg\" data-start=\"1880\" data-end=\"1899\">Objem m\u0155tveho priestoru<\/li><li data-section-id=\"gfc932\" data-start=\"1900\" data-end=\"1938\">Netesnos\u0165 spoja medzi ihlou a tryskou<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d841201 elementor-widget elementor-widget-text-editor\" data-id=\"d841201\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1940\" data-end=\"1978\">Tieto testy pom\u00e1haj\u00fa v\u00fdrobcom pos\u00fadi\u0165:<\/p><ul data-start=\"1980\" data-end=\"2145\"><li data-section-id=\"4m7yx6\" data-start=\"1980\" data-end=\"2009\">Konzistencia tesnenia piestu<\/li><li data-section-id=\"jtny4m\" data-start=\"2010\" data-end=\"2039\">Celistvos\u0165 valca a trysky<\/li><li data-section-id=\"13p4qmo\" data-start=\"2040\" data-end=\"2067\">\u00da\u010dinnos\u0165 mazania<\/li><li data-section-id=\"1rxkfq7\" data-start=\"2068\" data-end=\"2093\">Presnos\u0165 pod\u00e1vania d\u00e1vky<\/li><li data-section-id=\"njxgtt\" data-start=\"2094\" data-end=\"2145\">Spo\u013eahlivos\u0165 spojenia medzi injek\u010dnou strieka\u010dkou a ihlou<\/li><\/ul><p data-start=\"2147\" data-end=\"2270\">Modern\u00e9 laborat\u00f3ri\u00e1 \u010doraz \u010dastej\u0161ie zav\u00e1dzaj\u00fa automatizovan\u00e9 testovacie syst\u00e9my s cie\u013eom zlep\u0161i\u0165 opakovate\u013enos\u0165 v\u00fdsledkov a zn\u00ed\u017ei\u0165 vplyv obsluhy na v\u00fdsledky.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84b6ee2 elementor-widget elementor-widget-heading\" data-id=\"84b6ee2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sk\u00fa\u0161ka tesnosti injek\u010dn\u00fdch strieka\u010diek pod\u013ea normy ISO 8537<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d186872 elementor-widget elementor-widget-text-editor\" data-id=\"d186872\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2324\" data-end=\"2507\"><strong data-start=\"2324\" data-end=\"2348\">Testovanie tesnosti injek\u010dn\u00fdch strieka\u010diek<\/strong> je jedn\u00fdm z najd\u00f4le\u017eitej\u0161\u00edch postupov op\u00edsan\u00fdch v norme ISO 8537. T\u00e1to norma hodnot\u00ed \u00fanik vzduchu aj \u00fanik kvapaliny za r\u00f4znych tlakov\u00fdch podmienok.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-47c3651 e-grid e-con-full e-con e-child\" data-id=\"47c3651\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-bd0c720 e-con-full e-flex e-con e-child\" data-id=\"bd0c720\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb605b0 elementor-widget elementor-widget-heading\" data-id=\"eb605b0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00danik vzduchu po\u010das ods\u00e1vania<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1310954 elementor-widget elementor-widget-text-editor\" data-id=\"1310954\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2544\" data-end=\"2684\">V pr\u00edlohe B a pr\u00edlohe F s\u00fa op\u00edsan\u00e9 met\u00f3dy na zis\u0165ovanie \u00faniku vzduchu cez tesnenie piesta a spoje trysky injek\u010dnej strieka\u010dky za podmienok v\u00e1kuov\u00e9ho tlaku.<\/p><p data-start=\"2686\" data-end=\"2719\">Tento postup zvy\u010dajne zah\u0155\u0148a:<\/p><ol data-start=\"2721\" data-end=\"2926\"><li data-section-id=\"8f51yc\" data-start=\"2721\" data-end=\"2764\">Naplnenie injek\u010dnej strieka\u010dky destilovanou vodou<\/li><li data-section-id=\"11xil91\" data-start=\"2765\" data-end=\"2822\">Pripojenie injek\u010dnej strieka\u010dky ku kompatibilnej ku\u017ee\u013eovej spojke<\/li><li data-section-id=\"1w8sjai\" data-start=\"2823\" data-end=\"2852\">Vytvorenie podtlaku<\/li><li data-section-id=\"nzi51v\" data-start=\"2853\" data-end=\"2885\">Monitorovanie stability tlaku<\/li><li data-section-id=\"ad7xt5\" data-start=\"2886\" data-end=\"2926\">Zistenie \u00faniku alebo tvorby bubl\u00edn<\/li><\/ol><p data-start=\"2928\" data-end=\"3143\">Norma ISO 8537 stanovuje \u00farove\u0148 v\u00e1kua na <strong data-start=\"2965\" data-end=\"3010\">88 kPa pod okolit\u00fdm atmosf\u00e9rick\u00fdm tlakom<\/strong> na pos\u00fadenie netesnosti ods\u00e1vacieho syst\u00e9mu. Obsluha sleduje injek\u010dn\u00fa strieka\u010dku z h\u013eadiska poklesu tlaku, tvorby bubl\u00edn a uvo\u013enenia gumovej z\u00e1tky.<\/p><p data-start=\"3145\" data-end=\"3164\">Tento test overuje:<\/p><ul data-start=\"3166\" data-end=\"3287\"><li data-section-id=\"31dbu3\" data-start=\"3166\" data-end=\"3189\">Neporu\u0161enos\u0165 tesnenia piesta<\/li><li data-section-id=\"10m5ixj\" data-start=\"3190\" data-end=\"3222\">Tesniaca schopnos\u0165 n\u00e1boja ihly<\/li><li data-section-id=\"17ziab\" data-start=\"3223\" data-end=\"3252\">Stabilita pripojenia trysky<\/li><li data-section-id=\"1way5n8\" data-start=\"3253\" data-end=\"3287\">Odolnos\u0165 vo\u010di \u00faniku pri aspir\u00e1cii<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28726d3 e-con-full e-flex e-con e-child\" data-id=\"28726d3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4cf6b78 elementor-widget elementor-widget-heading\" data-id=\"4cf6b78\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e1kuov\u00e9 testovanie tesnosti \u2013 farmaceutick\u00e9 aplik\u00e1cie<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a833751 elementor-widget elementor-widget-text-editor\" data-id=\"a833751\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3339\" data-end=\"3513\">A <strong data-start=\"3341\" data-end=\"3376\">sk\u00fa\u0161ka tesnosti vo v\u00e1kuu vo farmaceutickom priemysle<\/strong> Tento postup je nevyhnutn\u00fd v pr\u00edpade lek\u00e1rskych injek\u010dn\u00fdch strieka\u010diek pou\u017e\u00edvan\u00fdch na pod\u00e1vanie inzul\u00ednu, preto\u017ee aj minim\u00e1lny \u00fanik m\u00f4\u017ee ovplyvni\u0165 presnos\u0165 d\u00e1vkovania alebo sterilitu.<\/p><p data-start=\"3515\" data-end=\"3595\">Spolo\u010dnos\u0165 Cell Instruments odpor\u00fa\u010da automatizovan\u00e9 syst\u00e9my na testovanie tesnosti vo v\u00e1kuu, ktor\u00e9 s\u00fa vybaven\u00e9:<\/p><ul data-start=\"3597\" data-end=\"3738\"><li data-section-id=\"le59d7\" data-start=\"3597\" data-end=\"3632\">Vysoko presn\u00e9 regul\u00e1tory v\u00e1kua<\/li><li data-section-id=\"1jdfnmj\" data-start=\"3633\" data-end=\"3662\">Digit\u00e1lne monitorovanie tlaku<\/li><li data-section-id=\"105a6xv\" data-start=\"3663\" data-end=\"3684\">Anal\u00fdza poklesu \u00faniku<\/li><li data-section-id=\"fca3b5\" data-start=\"3685\" data-end=\"3712\">Programovate\u013en\u00e1 doba udr\u017eania<\/li><li data-section-id=\"cixp3u\" data-start=\"3713\" data-end=\"3738\">Softv\u00e9r na zaznamen\u00e1vanie \u00fadajov<\/li><\/ul><p data-start=\"3740\" data-end=\"3896\">Tieto syst\u00e9my zvy\u0161uj\u00fa opakovate\u013enos\u0165 v porovnan\u00ed s manu\u00e1lnymi met\u00f3dami merania v\u00e1kua a pom\u00e1haj\u00fa laborat\u00f3ri\u00e1m splni\u0165 po\u017eiadavky na dokument\u00e1ciu pod\u013ea GMP a ISO.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa6d2ef elementor-widget elementor-widget-heading\" data-id=\"fa6d2ef\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Met\u00f3dy testovania integrity tesnenia injek\u010dn\u00fdch strieka\u010diek<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0cbf91c elementor-widget elementor-widget-text-editor\" data-id=\"0cbf91c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3943\" data-end=\"4074\">Str\u00e1nka <strong data-start=\"3947\" data-end=\"3978\">sk\u00fa\u0161ka tesnosti injek\u010dnej strieka\u010dky<\/strong> posudzuje, \u010di m\u00f4\u017ee tekutina alebo vzduch prenikn\u00fa\u0165 cez tesniace rozhrania po\u010das kompresie alebo ods\u00e1vania.<\/p><p data-start=\"4076\" data-end=\"4122\">Pr\u00edloha E normy ISO 8537 sa zameriava na \u00fanik kvapal\u00edn v nasleduj\u00facich pr\u00edpadoch:<\/p><ul data-start=\"4124\" data-end=\"4190\"><li data-section-id=\"z11dbz\" data-start=\"4124\" data-end=\"4138\">Tesnenia piestov<\/li><li data-section-id=\"1p89988\" data-start=\"4139\" data-end=\"4167\">Pripojenia trysiek injek\u010dn\u00fdch strieka\u010diek<\/li><li data-section-id=\"1aynqcu\" data-start=\"4168\" data-end=\"4190\">Spojky ihly a valca<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b34aa1c e-grid e-con-full e-con e-child\" data-id=\"b34aa1c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7afb7c0 elementor-widget elementor-widget-text-editor\" data-id=\"7afb7c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4365\" data-end=\"4389\">Po\u010das testovania oper\u00e1tori vytv\u00e1raj\u00fa vn\u00fatorn\u00fd tlak vo v\u00fd\u0161ke <strong data-start=\"4251\" data-end=\"4277\">300 kPa manometrick\u00fd tlak<\/strong> a udr\u017eujte tlak po dobu 30 sek\u00fand, pri\u010dom na piest p\u00f4sobte bo\u010dnou silou.<\/p><p data-start=\"4365\" data-end=\"4389\">Postup vyhodnocuje:<\/p><ul data-start=\"4391\" data-end=\"4508\"><li data-section-id=\"1k1t3bu\" data-start=\"4391\" data-end=\"4420\">Odolnos\u0165 tesnenia proti deform\u00e1cii<\/li><li data-section-id=\"vhj5a5\" data-start=\"4421\" data-end=\"4457\">\u00danik pri bo\u010dnom za\u0165a\u017een\u00ed<\/li><li data-section-id=\"1ubek41\" data-start=\"4458\" data-end=\"4485\">Stabilita pohybu piesta<\/li><li data-section-id=\"tj03kp\" data-start=\"4486\" data-end=\"4508\">Integrita pripojenia<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5283d17 elementor-widget elementor-widget-text-editor\" data-id=\"5283d17\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4510\" data-end=\"4558\">Spo\u013eahliv\u00fd syst\u00e9m kontroly tesnosti by mal zabezpe\u010dova\u0165:<\/p><ul data-start=\"4560\" data-end=\"4689\"><li data-section-id=\"1ogn8km\" data-start=\"4560\" data-end=\"4588\">Stabiln\u00e1 tvorba tlaku<\/li><li data-section-id=\"81fo7t\" data-start=\"4589\" data-end=\"4617\">Presn\u00e9 p\u00f4sobenie sily<\/li><li data-section-id=\"vtwu91\" data-start=\"4618\" data-end=\"4647\">Detekcia \u00faniku v re\u00e1lnom \u010dase<\/li><li data-section-id=\"198rl1a\" data-start=\"4648\" data-end=\"4689\">Monitorovanie posunu s vysok\u00fdm rozl\u00ed\u0161en\u00edm<\/li><\/ul><p data-start=\"4691\" data-end=\"4868\">Spolo\u010dnos\u0165 Cell Instruments pon\u00faka rie\u0161enia na meranie \u00faniku tlaku a kontrolu tesnosti, ktor\u00e9 s\u00fa vhodn\u00e9 pre inzul\u00ednov\u00e9 strieka\u010dky, syst\u00e9my Luer, farmaceutick\u00e9 obaly a aplik\u00e1cie v oblasti zdravotn\u00edckych obalov.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1592e7 elementor-widget elementor-widget-heading\" data-id=\"d1592e7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testovanie sily sklzu strieka\u010dky<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86fac58 elementor-widget elementor-widget-text-editor\" data-id=\"86fac58\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4907\" data-end=\"5032\"><strong data-start=\"4907\" data-end=\"4938\">Testovanie sily sklzu strieka\u010dky<\/strong> meria silu potrebn\u00fa na spustenie a udr\u017eanie pohybu piesta po\u010das vytl\u00e1\u010dania kvapaliny.<\/p><p data-start=\"5034\" data-end=\"5176\">Pr\u00edloha C normy ISO 8537 stanovuje pou\u017eitie mechanick\u00e9ho sk\u00fa\u0161obn\u00e9ho zariadenia na zaznamen\u00e1vanie prev\u00e1dzkovej sily piestu po\u010das vytl\u00e1\u010dania vody zo strieka\u010dky.<\/p><p data-start=\"5178\" data-end=\"5206\">Tento test vo v\u0161eobecnosti meria:<\/p><ul data-start=\"5208\" data-end=\"5305\"><li data-section-id=\"uhip3k\" data-start=\"5208\" data-end=\"5227\">Vo\u013en\u00e1 sila<\/li><li data-section-id=\"d3dsxi\" data-start=\"5228\" data-end=\"5241\">K\u013azav\u00e1 sila<\/li><li data-section-id=\"td0rt7\" data-start=\"5242\" data-end=\"5267\">Priemern\u00e1 prev\u00e1dzkov\u00e1 sila<\/li><li data-section-id=\"fqmeyx\" data-start=\"5268\" data-end=\"5305\">Zabezpe\u010dte rovnomernos\u0165 sily po\u010das cel\u00e9ho zdvihu<\/li><\/ul><p data-start=\"5307\" data-end=\"5456\">Stabiln\u00fd v\u00fdkon v oblasti klznej sily je k\u013e\u00fa\u010dov\u00fd, preto\u017ee nadmern\u00e1 sila m\u00f4\u017ee zn\u00ed\u017ei\u0165 pou\u017eite\u013enos\u0165, zatia\u013e \u010do nedostato\u010dn\u00fd odpor m\u00f4\u017ee ohrozi\u0165 kontrolu d\u00e1vkovania.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18cc935 elementor-widget elementor-widget-heading\" data-id=\"18cc935\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">K\u013e\u00fa\u010dov\u00e9 faktory ovplyv\u0148uj\u00face vztlakov\u00fa silu<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d703620 e-grid e-con-full e-con e-child\" data-id=\"d703620\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c02067 elementor-widget elementor-widget-text-editor\" data-id=\"5c02067\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5497\" data-end=\"5556\">Na k\u013azav\u00e9 vlastnosti injek\u010dnej strieka\u010dky vpl\u00fdva nieko\u013eko parametrov:<\/p><ul data-start=\"5558\" data-end=\"5684\"><li data-section-id=\"1futzim\" data-start=\"5558\" data-end=\"5591\">Rovnomernos\u0165 nan\u00e1\u0161ania silik\u00f3nov\u00e9ho maziva<\/li><li data-section-id=\"kuh4lo\" data-start=\"5592\" data-end=\"5617\">Materi\u00e1l gumovej z\u00e1tky<\/li><li data-section-id=\"53gmea\" data-start=\"5618\" data-end=\"5647\">Rozmerov\u00e1 presnos\u0165 hlavne<\/li><li data-section-id=\"5t72bj\" data-start=\"5648\" data-end=\"5666\">Povrchov\u00e9 trenie<\/li><li data-section-id=\"198q7yk\" data-start=\"5667\" data-end=\"5684\">Priemer ihly<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9cd7bf elementor-widget elementor-widget-text-editor\" data-id=\"a9cd7bf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5686\" data-end=\"5745\">Profesion\u00e1lny syst\u00e9m na meranie sily p\u00f4sobiacej na injek\u010dn\u00fa strieka\u010dku by mal obsahova\u0165:<\/p><ul data-start=\"5747\" data-end=\"5906\"><li data-section-id=\"ne6nqw\" data-start=\"5747\" data-end=\"5779\">Technol\u00f3gia presn\u00fdch sn\u00edma\u010dov za\u0165a\u017eenia<\/li><li data-section-id=\"1wxb0hx\" data-start=\"5780\" data-end=\"5811\">Riadenie pohybu s kon\u0161tantnou r\u00fdchlos\u0165ou<\/li><li data-section-id=\"h51txm\" data-start=\"5812\" data-end=\"5847\">Anal\u00fdza krivky sily a posunutia<\/li><li data-section-id=\"gjpujf\" data-start=\"5848\" data-end=\"5874\">Nastavite\u013en\u00e9 sk\u00fa\u0161obn\u00e9 pr\u00edpravky<\/li><li data-section-id=\"19afykk\" data-start=\"5875\" data-end=\"5906\">Po\u010d\u00edta\u010dov\u00e9 zber \u00fadajov<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef0db14 elementor-widget elementor-widget-text-editor\" data-id=\"ef0db14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Spolo\u010dnos\u0165 Cell Instruments odpor\u00fa\u010da univerz\u00e1lne syst\u00e9my na sk\u00fa\u0161anie materi\u00e1lov vybaven\u00e9 \u0161peci\u00e1lne prisp\u00f4soben\u00fdmi dr\u017eiakmi na injek\u010dn\u00e9 strieka\u010dky pre sk\u00fa\u0161ky sily piestu pod\u013ea normy ISO 8537.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4d61be elementor-widget elementor-widget-heading\" data-id=\"c4d61be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mierka na m\u0155tvy priestor pre inzul\u00ednov\u00e9 strieka\u010dky<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2c205a elementor-widget elementor-widget-text-editor\" data-id=\"a2c205a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6115\" data-end=\"6239\"><strong data-start=\"6115\" data-end=\"6141\">Meranie m\u0155tveho priestoru<\/strong> ur\u010duje objem tekutiny, ktor\u00fd zostane vo vn\u00fatri injek\u010dnej strieka\u010dky po \u00faplnom stla\u010den\u00ed piestu.<\/p><p data-start=\"6241\" data-end=\"6394\">N\u00edzky m\u0155tvy priestor je obzvl\u00e1\u0161\u0165 d\u00f4le\u017eit\u00fd pri inzul\u00ednov\u00fdch injek\u010dn\u00fdch strieka\u010dk\u00e1ch, preto\u017ee zvy\u0161ky lieku m\u00f4\u017eu ovplyvni\u0165 presnos\u0165 d\u00e1vkovania a zv\u00fd\u0161i\u0165 mno\u017estvo farmaceutick\u00e9ho odpadu.<\/p><p data-start=\"6396\" data-end=\"6484\">Pr\u00edloha D normy ISO 8537 opisuje gravimetrick\u00fa sk\u00fa\u0161obn\u00fa met\u00f3du zalo\u017een\u00fa na meran\u00ed hmotnosti vody.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3582f04 e-grid e-con-full e-con e-child\" data-id=\"3582f04\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-e4e0eef e-con-full e-flex e-con e-child\" data-id=\"e4e0eef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ee7135a elementor-widget elementor-widget-heading\" data-id=\"ee7135a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Postup merania m\u0155tveho priestoru<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60271a8 elementor-widget elementor-widget-text-editor\" data-id=\"60271a8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6524\" data-end=\"6547\">Postup zah\u0155\u0148a:<\/p><ol data-start=\"6549\" data-end=\"6719\"><li data-section-id=\"5n54cf\" data-start=\"6549\" data-end=\"6578\">V\u00e1\u017eenie pr\u00e1zdnej injek\u010dnej strieka\u010dky<\/li><li data-section-id=\"1po99wn\" data-start=\"6579\" data-end=\"6622\">Naplnenie injek\u010dnej strieka\u010dky destilovanou vodou<\/li><li data-section-id=\"q59tts\" data-start=\"6623\" data-end=\"6656\">\u00dapln\u00e9 vypustenie vody<\/li><li data-section-id=\"1w7zx7c\" data-start=\"6657\" data-end=\"6682\">Op\u00e4tovn\u00e9 zv\u00e1\u017eenie injek\u010dnej strieka\u010dky<\/li><li data-section-id=\"1bth81y\" data-start=\"6683\" data-end=\"6719\">V\u00fdpo\u010det objemu zadr\u017eanej vody<\/li><\/ol><p data-start=\"6721\" data-end=\"6791\">Zost\u00e1vaj\u00faci objem vody zodpoved\u00e1 objemu m\u0155tveho priestoru injek\u010dnej strieka\u010dky.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c8b1057 e-con-full e-flex e-con e-child\" data-id=\"c8b1057\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c4747c elementor-widget elementor-widget-heading\" data-id=\"7c4747c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">V\u00fdznam testovania v m\u0155tvom priestore<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac04fa1 elementor-widget elementor-widget-text-editor\" data-id=\"ac04fa1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6831\" data-end=\"6883\">Meranie m\u0155tveho priestoru pom\u00e1ha v\u00fdrobcom pos\u00fadi\u0165:<\/p><ul data-start=\"6885\" data-end=\"6993\"><li data-section-id=\"1yt1bzi\" data-start=\"6885\" data-end=\"6902\">Presnos\u0165 d\u00e1vkovania<\/li><li data-section-id=\"to7kax\" data-start=\"6903\" data-end=\"6928\">Zvy\u0161kov\u00e1 retencia lieku<\/li><li data-section-id=\"1uwyw95\" data-start=\"6929\" data-end=\"6962\">Optimaliz\u00e1cia kon\u0161trukcie injek\u010dnej strieka\u010dky<\/li><li data-section-id=\"19wzgi9\" data-start=\"6963\" data-end=\"6993\">\u00da\u010dinnos\u0165 kon\u0161trukcie ihlov\u00e9ho n\u00e1boja<\/li><\/ul><p data-start=\"6995\" data-end=\"7121\">Spolo\u010dnos\u0165 Cell Instruments pon\u00faka integr\u00e1ciu presn\u00fdch v\u00e1h a testovacie platformy na mieru pre automatizovan\u00fa anal\u00fdzu m\u0155tveho priestoru.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8195461 elementor-widget elementor-widget-heading\" data-id=\"8195461\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Odpor\u00fa\u010dan\u00e9 sk\u00fa\u0161obn\u00e9 zariadenia na zabezpe\u010denie s\u00faladu s normou ISO 8537<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-129d4b6 elementor-widget elementor-widget-text-editor\" data-id=\"129d4b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"7186\" data-end=\"7244\">Na zabezpe\u010denie s\u00faladu s normou ISO 8537 laborat\u00f3ri\u00e1 be\u017ene pou\u017e\u00edvaj\u00fa:<\/p><div class=\"TyagGW_tableContainer\"><div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"7246\" data-end=\"7579\"><thead data-start=\"7246\" data-end=\"7284\"><tr data-start=\"7246\" data-end=\"7284\"><th class=\"\" data-start=\"7246\" data-end=\"7258\" data-col-size=\"sm\">Testov\u00e1 \u00faloha<\/th><th class=\"\" data-start=\"7258\" data-end=\"7284\" data-col-size=\"sm\">Odpor\u00fa\u010dan\u00fd n\u00e1stroj<\/th><\/tr><\/thead><tbody data-start=\"7295\" data-end=\"7579\"><tr data-start=\"7295\" data-end=\"7342\"><td style=\"text-align: center;\" data-start=\"7295\" data-end=\"7320\" data-col-size=\"sm\">V\u00e1kuov\u00e9 testovanie tesnosti<\/td><td style=\"text-align: center;\" data-start=\"7320\" data-end=\"7342\" data-col-size=\"sm\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/sk\/vacuum-leak-tester-for-syringe-plunger-stopper-and-seal\/\">SLT-02 Tester netesnost\u00ed injek\u010dn\u00fdch strieka\u010diek<\/a><\/td><\/tr><tr data-start=\"7402\" data-end=\"7456\"><td style=\"text-align: center;\" data-start=\"7402\" data-end=\"7427\" data-col-size=\"sm\">P\u00f4sobiaca sila piesta<\/td><td style=\"text-align: center;\" data-start=\"7427\" data-end=\"7456\" data-col-size=\"sm\"><p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/sk\/syringes-plunger-glide-force-tester\/\">SSR-01 Tester posuvn\u00e9ho odporu strieka\u010dky<\/a><\/p><\/td><\/tr><tr data-start=\"7457\" data-end=\"7513\"><td style=\"text-align: center;\" data-start=\"7457\" data-end=\"7479\" data-col-size=\"sm\">Anal\u00fdza m\u0155tveho priestoru<\/td><td style=\"text-align: center;\" data-start=\"7479\" data-end=\"7513\" data-col-size=\"sm\">Gravimetrick\u00fd merac\u00ed syst\u00e9m<\/td><\/tr><tr data-start=\"7514\" data-end=\"7579\"><td style=\"text-align: center;\" data-start=\"7514\" data-end=\"7543\" data-col-size=\"sm\">Sk\u00fa\u0161ka tesnosti pripojen\u00ed<\/td><td style=\"text-align: center;\" data-start=\"7543\" data-end=\"7579\" data-col-size=\"sm\"><div class=\"elementor-element elementor-element-9d87235 elementor-widget elementor-widget-heading\" data-id=\"9d87235\" data-element_type=\"widget\" data-widget_type=\"heading.default\"><div class=\"elementor-widget-container\"><p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/sk\/syringe-plunger-seal-integrity-tester\/\">SPPT-01 Tester tesnosti injek\u010dnej strieka\u010dky s pozit\u00edvnym tlakom<\/a><\/p><\/div><\/div><\/td><\/tr><\/tbody><\/table><\/div><\/div><p data-start=\"7581\" data-end=\"7773\">Spolo\u010dnos\u0165 Cell Instruments pon\u00faka automatiza\u010dn\u00e9 rie\u0161enia na mieru pre laborat\u00f3ri\u00e1 zaoberaj\u00face sa testovan\u00edm injek\u010dn\u00fdch strieka\u010diek, vr\u00e1tane viacstanicov\u00fdch syst\u00e9mov, softv\u00e9ru na spr\u00e1vu \u00fadajov a integrovan\u00fdch platforiem na kontrolu kvality.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b08dc9a elementor-widget elementor-widget-heading\" data-id=\"b08dc9a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u010casto kladen\u00e9 ot\u00e1zky<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e8bf18 elementor-widget elementor-widget-text-editor\" data-id=\"3e8bf18\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>\u010co je norma ISO 8537?<\/strong><br \/>ISO 8537 je medzin\u00e1rodn\u00e1 norma, ktor\u00e1 stanovuje po\u017eiadavky a sk\u00fa\u0161obn\u00e9 met\u00f3dy pre steriln\u00e9 inzul\u00ednov\u00e9 injek\u010dn\u00e9 strieka\u010dky na jedno pou\u017eitie s ihlou alebo bez nej.<\/p><p><strong>\u010co je to sk\u00fa\u0161ka tesnosti injek\u010dn\u00fdch strieka\u010diek pod\u013ea normy ISO 8537?<\/strong><br \/>Testovanie tesnosti injek\u010dn\u00fdch strieka\u010diek sl\u00fa\u017ei na pos\u00fadenie \u00faniku vzduchu alebo kvapaliny cez tesnenia piestu, trysky injek\u010dn\u00fdch strieka\u010diek a spojenia s ihlou za podmienok v\u00e1kua alebo tlaku.<\/p><p><strong>Pre\u010do je d\u00f4le\u017eit\u00e9 testovanie k\u013azavosti injek\u010dnej strieka\u010dky?<\/strong><br \/>Testovanie k\u013azavosti overuje, \u010di sa piest pohybuje plynulo a rovnomerne, \u010d\u00edm sa zaru\u010duje presn\u00e9 pod\u00e1vanie inzul\u00ednu a spr\u00e1vna funk\u010dnos\u0165 injek\u010dnej strieka\u010dky.<\/p><p><strong>\u010co je to test integrity tesnenia injek\u010dnej strieka\u010dky?<\/strong><br \/>Test integrity tesnenia injek\u010dnej strieka\u010dky sl\u00fa\u017ei na overenie, \u010di tesniace plochy zabra\u0148uj\u00fa \u00faniku tekutiny v podmienkach stla\u010denia a ods\u00e1vania.<\/p><p><strong>Ako prebieha meranie m\u0155tveho priestoru?<\/strong><br \/>Pri meran\u00ed m\u0155tveho priestoru sa pou\u017e\u00edva gravimetrick\u00e1 met\u00f3da, pri ktorej sa porovn\u00e1va hmotnos\u0165 injek\u010dnej strieka\u010dky pred a po vytla\u010den\u00ed vody, \u010d\u00edm sa ur\u010d\u00ed objem zvy\u0161kovej kvapaliny.<\/p><p><strong>Na \u010do sa pou\u017e\u00edvaj\u00fa tieto n\u00e1stroje <a href=\"https:\/\/www.iso.org\/standard\/60510.html\" target=\"_blank\" rel=\"noopener\">ISO 8537<\/a> testovanie?<\/strong><br \/>Medzi be\u017en\u00e9 pr\u00edstroje patria v\u00e1kuov\u00e9 tesnostn\u00e9 testery, univerz\u00e1lne sk\u00fa\u0161obn\u00e9 stroje, syst\u00e9my na meranie poklesu tlaku a gravimetrick\u00e9 meracie zariadenia.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 8537 Sk\u00fa\u0161anie funk\u010dnosti inzul\u00ednov\u00fdch strieka\u010diek \u2013 Norma ISO 8537 stanovuje po\u017eiadavky na v\u00fdkonnos\u0165 a sk\u00fa\u0161anie steriln\u00fdch inzul\u00ednov\u00fdch strieka\u010diek na jedno pou\u017eitie, s ihlou alebo bez nej. Norma sa zameriava na bezpe\u010dnos\u0165 injek\u010dn\u00fdch strieka\u010diek, ich funk\u010dnos\u0165, tesniace vlastnosti, presnos\u0165 d\u00e1vkovania a prev\u00e1dzkov\u00fa spo\u013eahlivos\u0165. V\u00fdrobcovia a laborat\u00f3ri\u00e1 zabezpe\u010duj\u00face kontrolu kvality pou\u017e\u00edvaj\u00fa normu ISO 8537 na overenie, \u010di injek\u010dn\u00e9 strieka\u010dky funguj\u00fa konzistentne po\u010das klinick\u00e9ho pou\u017e\u00edvania. [\u2026]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2610","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/sk\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 8537 Syringe Functionality Testing for Insulin Syringe ISO 8537 specifies the performance and testing requirements for sterile single-use insulin syringes, with or without needles. The standard focuses on syringe safety, functionality, sealing performance, dosage accuracy, and operational reliability. Manufacturers and quality laboratories use ISO 8537 to verify that syringes perform consistently during clinical use.&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/posts\/2610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/comments?post=2610"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/posts\/2610\/revisions"}],"predecessor-version":[{"id":2624,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/posts\/2610\/revisions\/2624"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/media?parent=2610"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/categories?post=2610"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/sk\/wp-json\/wp\/v2\/tags?post=2610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}