{"id":2272,"date":"2025-07-21T06:29:17","date_gmt":"2025-07-21T06:29:17","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2272"},"modified":"2025-08-01T06:19:34","modified_gmt":"2025-08-01T06:19:34","slug":"packaging-compression-strength-tester","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/ru\/packaging-compression-strength-tester\/","title":{"rendered":"\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0441\u043e\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0442\u0435\u0441\u0442\u0435\u0440\u0430 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438 \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0438 \u043d\u0430 \u0441\u0436\u0430\u0442\u0438\u0435"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2272\" class=\"elementor elementor-2272\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-19858ab e-flex e-con-boxed e-con e-parent\" data-id=\"19858ab\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-78ab2fd elementor-widget elementor-widget-heading\" data-id=\"78ab2fd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0441\u043e\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0442\u0435\u0441\u0442\u0435\u0440\u0430 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438 \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0438 \u043d\u0430 \u0441\u0436\u0430\u0442\u0438\u0435<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-519ba26 e-flex e-con-boxed e-con e-parent\" data-id=\"519ba26\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-31bfde3 elementor-widget elementor-widget-text-editor\" data-id=\"31bfde3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>In today\u2019s fast-paced logistics and pharmaceutical supply chains, <em data-start=\"661\" data-end=\"700\">packaging compression strength tester<\/em> solutions are indispensable for safeguarding product quality and consumer safety. At <strong data-start=\"786\" data-end=\"806\">\u041a\u043b\u0435\u0442\u043e\u0447\u043d\u044b\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u044b<\/strong>, we understand the significance of maintaining packaging integrity under real-world stress. This article provides a professional yet accessible overview of compression testing, guided by ISO 12048, and introduces effective testing methods that enhance packaging reliability\u2014especially when using high-performance equipment like the <strong data-start=\"1139\" data-end=\"1176\">\u0422\u0435\u0441\u0442\u0435\u0440 \u0441\u0436\u0430\u0442\u0438\u044f \u043f\u0430\u043a\u0435\u0442\u043e\u0432 PCT-01<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-273ed48 e-flex e-con-boxed e-con e-parent\" data-id=\"273ed48\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8b60793 elementor-widget elementor-widget-heading\" data-id=\"8b60793\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Understanding the Role of Packaging Compression Strength Tester<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ef5cba8 e-flex e-con-boxed e-con e-parent\" data-id=\"ef5cba8\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f4a2392 elementor-widget elementor-widget-text-editor\" data-id=\"f4a2392\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1253\" data-end=\"1665\">A <strong data-start=\"1255\" data-end=\"1296\">packaging compression strength tester<\/strong> is a precision instrument designed to measure how much compressive force a packaging unit can endure before it deforms or fails. Commonly applied to <strong data-start=\"1446\" data-end=\"1470\">composite film packs<\/strong>, <strong data-start=\"1472\" data-end=\"1489\">infusion bags<\/strong>, <strong data-start=\"1491\" data-end=\"1510\">plastic bottles<\/strong>, \u0438 <strong data-start=\"1516\" data-end=\"1541\">corrugated containers<\/strong>, this test provides essential data for packaging engineers, quality control professionals, and regulatory compliance teams.<\/p><p data-start=\"1667\" data-end=\"2050\">This type of testing is vital in medical, food, and logistics industries where packages may face <strong data-start=\"1764\" data-end=\"1785\">stacking pressure<\/strong>, <strong data-start=\"1787\" data-end=\"1807\">transport shocks<\/strong>, \u0438 <strong data-start=\"1813\" data-end=\"1843\">prolonged warehouse stress<\/strong>. Ensuring a packaging solution withstands compressive forces not only protects the contents but also contributes to environmental sustainability by reducing material waste due to damage or product spoilage.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d212999 e-flex e-con-boxed e-con e-parent\" data-id=\"d212999\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3062c82 elementor-widget elementor-widget-heading\" data-id=\"3062c82\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 12048: Testing Framework and Significance<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-699cf71 e-flex e-con-boxed e-con e-parent\" data-id=\"699cf71\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1263d69 elementor-widget elementor-widget-text-editor\" data-id=\"1263d69\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2108\" data-end=\"2380\">\u0421\u0430\u0439\u0442 <a href=\"https:\/\/www.iso.org\/standard\/20810.html\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"2112\" data-end=\"2125\">ISO 12048<\/strong><\/a> standard\u2014titled <em data-start=\"2142\" data-end=\"2253\">\u201cPackaging \u2014 Complete, filled transport packages \u2014 Compression and stacking tests using a compression tester\u201d<\/em>\u2014is a widely accepted benchmark that outlines procedures for assessing compressive strength in a structured, repeatable manner.<\/p><p data-start=\"2382\" data-end=\"2424\">Key highlights from <strong data-start=\"2402\" data-end=\"2415\">ISO 12048<\/strong> \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:<\/p><ul><li data-start=\"2428\" data-end=\"2565\"><strong data-start=\"2428\" data-end=\"2447\">Test Objectives<\/strong>: Evaluate the packaging\u2019s structural integrity and the protection it provides to its contents under vertical loads.<\/li><li data-start=\"2568\" data-end=\"2669\"><strong data-start=\"2568\" data-end=\"2587\">Test Conditions<\/strong>: Samples must be preconditioned at 23\u00b0C and 50% relative humidity for 48 hours.<\/li><li data-start=\"2672\" data-end=\"2800\"><strong data-start=\"2672\" data-end=\"2690\">Test Execution<\/strong>: A constant compression speed\u2014(10 \u00b1 3) mm\/min\u2014is applied until failure or a predefined endpoint is reached.<\/li><li data-start=\"2803\" data-end=\"2891\"><strong data-start=\"2803\" data-end=\"2827\">Measurement Accuracy<\/strong>: The tester must provide force measurements within \u00b12% error.<\/li><li data-start=\"2894\" data-end=\"3022\"><strong data-start=\"2894\" data-end=\"2919\">Platen Specifications<\/strong>: Parallelism between pressure plates must be within 1:1000 tolerance for accurate force application.<\/li><li data-start=\"3025\" data-end=\"3144\"><strong data-start=\"3025\" data-end=\"3043\">Data Recording<\/strong>: Continuous load vs. deformation data capture is mandatory to identify peak load and failure points.<\/li><\/ul><p data-start=\"3146\" data-end=\"3301\">These provisions ensure that testing reflects real-world scenarios and supports decision-making in <strong data-start=\"3245\" data-end=\"3300\">design, quality assurance, and packaging compliance<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3b29aa8 e-flex e-con-boxed e-con e-parent\" data-id=\"3b29aa8\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-abc6410 elementor-widget elementor-widget-heading\" data-id=\"abc6410\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test Execution: From Setup to Interpretation<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d536a4f e-flex e-con-boxed e-con e-parent\" data-id=\"d536a4f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f1afc5c elementor-widget elementor-widget-text-editor\" data-id=\"f1afc5c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3358\" data-end=\"3445\">Proper use of a <strong data-start=\"3374\" data-end=\"3415\">packaging compression strength tester<\/strong> follows a structured process:<\/p><ol data-start=\"3447\" data-end=\"4145\"><li data-start=\"3447\" data-end=\"3571\"><p data-start=\"3450\" data-end=\"3571\"><strong data-start=\"3450\" data-end=\"3487\">Sample Preparation &amp; Conditioning<\/strong><br data-start=\"3487\" data-end=\"3490\" \/>Ensure test samples are clean, undamaged, and preconditioned as per ISO 12048.<\/p><\/li><li data-start=\"3573\" data-end=\"3739\"><p data-start=\"3576\" data-end=\"3739\"><strong data-start=\"3576\" data-end=\"3595\">Equipment Setup<\/strong><br data-start=\"3595\" data-end=\"3598\" \/>The specimen is placed between <strong data-start=\"3632\" data-end=\"3668\">parallel upper and lower platens<\/strong> of the tester. Accurate alignment is critical to avoid skewed results.<\/p><\/li><li data-start=\"3741\" data-end=\"3864\"><p data-start=\"3744\" data-end=\"3864\"><strong data-start=\"3744\" data-end=\"3763\">Test Parameters<\/strong><br data-start=\"3763\" data-end=\"3766\" \/>Set compression speed, endpoint conditions (load, deformation, or collapse), and safety limits.<\/p><\/li><li data-start=\"3866\" data-end=\"3993\"><p data-start=\"3869\" data-end=\"3993\"><strong data-start=\"3869\" data-end=\"3881\">Test Run<\/strong><br data-start=\"3881\" data-end=\"3884\" \/>The upper platen compresses the specimen. Real-time data on load and deformation are displayed and logged.<\/p><\/li><li data-start=\"3995\" data-end=\"4145\"><p data-start=\"3998\" data-end=\"4145\"><strong data-start=\"3998\" data-end=\"4010\">Analysis<\/strong><br data-start=\"4010\" data-end=\"4013\" \/>Review force-deformation curves to determine <strong data-start=\"4061\" data-end=\"4086\">maximum load capacity<\/strong>, <strong data-start=\"4088\" data-end=\"4116\">elastic deformation zone<\/strong>, \u0438 <strong data-start=\"4122\" data-end=\"4144\">failure thresholds<\/strong>.<\/p><\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b558a18 e-flex e-con-boxed e-con e-parent\" data-id=\"b558a18\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1f3d5cc elementor-widget elementor-widget-video\" data-id=\"1f3d5cc\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=Zcv0ejzEkW0&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;play_on_mobile&quot;:&quot;yes&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3379482 e-flex e-con-boxed e-con e-parent\" data-id=\"3379482\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5eec8d3 elementor-widget elementor-widget-heading\" data-id=\"5eec8d3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why Choose the PCT-01 Package Compression Tester from Cell Instruments<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6dff4a0 e-flex e-con-boxed e-con e-parent\" data-id=\"6dff4a0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf3f851 elementor-widget elementor-widget-text-editor\" data-id=\"bf3f851\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4228\" data-end=\"4531\">At Cell Instruments, our <strong data-start=\"4253\" data-end=\"4290\">\u0422\u0435\u0441\u0442\u0435\u0440 \u0441\u0436\u0430\u0442\u0438\u044f \u043f\u0430\u043a\u0435\u0442\u043e\u0432 PCT-01<\/strong> offers cutting-edge features that ensure <strong data-start=\"4332\" data-end=\"4354\">accurate, reliable<\/strong>, \u0438 <strong data-start=\"4360\" data-end=\"4382\">standard-compliant<\/strong> testing. With precise load cells, automatic data logging, and customizable test settings, the PCT-01 is ideal for evaluating packaging formats like:<\/p><ul data-start=\"4533\" data-end=\"4679\"><li data-start=\"4533\" data-end=\"4582\"><p data-start=\"4535\" data-end=\"4582\"><strong data-start=\"4535\" data-end=\"4580\">Medical infusion bags and plastic bottles<\/strong><\/p><\/li><li data-start=\"4583\" data-end=\"4623\"><p data-start=\"4585\" data-end=\"4623\"><strong data-start=\"4585\" data-end=\"4621\">Food trays and laminated pouches<\/strong><\/p><\/li><li data-start=\"4624\" data-end=\"4679\"><p data-start=\"4626\" data-end=\"4679\"><strong data-start=\"4626\" data-end=\"4679\">Blood bags and pharmaceutical secondary packaging<\/strong><\/p><\/li><\/ul><p data-start=\"4681\" data-end=\"4787\">Additionally, the <strong data-start=\"4699\" data-end=\"4709\">PCT-01<\/strong> meets all critical requirements of <strong data-start=\"4745\" data-end=\"4758\">ISO 12048<\/strong> \u0438 <strong data-start=\"4763\" data-end=\"4776\">ASTM D642<\/strong>, offering:<\/p><ul data-start=\"4789\" data-end=\"4986\"><li data-start=\"4789\" data-end=\"4834\"><p data-start=\"4791\" data-end=\"4834\"><strong data-start=\"4791\" data-end=\"4832\">Force measurement accuracy within \u00b12%<\/strong><\/p><\/li><li data-start=\"4835\" data-end=\"4877\"><p data-start=\"4837\" data-end=\"4877\"><strong data-start=\"4837\" data-end=\"4875\">Customizable compression endpoints<\/strong><\/p><\/li><li data-start=\"4878\" data-end=\"4933\"><p data-start=\"4880\" data-end=\"4933\"><strong data-start=\"4880\" data-end=\"4931\">Parallel platen design with overload protection<\/strong><\/p><\/li><li data-start=\"4934\" data-end=\"4986\"><p data-start=\"4936\" data-end=\"4986\"><strong data-start=\"4936\" data-end=\"4986\">Real-time curve plotting for advanced analysis<\/strong><\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-76c9214 e-flex e-con-boxed e-con e-parent\" data-id=\"76c9214\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-03bb959 elementor-widget elementor-widget-heading\" data-id=\"03bb959\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Benefits of Compression Testing for Packaging Development<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e88a9e2 elementor-widget elementor-widget-text-editor\" data-id=\"e88a9e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5056\" data-end=\"5162\">Implementing compression tests with a quality-certified <strong data-start=\"5112\" data-end=\"5153\">packaging compression strength tester<\/strong> ensures:<\/p><ul data-start=\"5164\" data-end=\"5455\"><li data-start=\"5164\" data-end=\"5224\"><p data-start=\"5166\" data-end=\"5224\"><strong data-start=\"5166\" data-end=\"5196\">Improved packaging designs<\/strong> with validated durability<\/p><\/li><li data-start=\"5225\" data-end=\"5296\"><p data-start=\"5227\" data-end=\"5296\"><strong data-start=\"5227\" data-end=\"5251\">Fewer product losses<\/strong> due to collapse or crushing during transit<\/p><\/li><li data-start=\"5297\" data-end=\"5381\"><p data-start=\"5299\" data-end=\"5381\"><strong data-start=\"5299\" data-end=\"5324\">\u0421\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u0435 \u043d\u043e\u0440\u043c\u0430\u0442\u0438\u0432\u043d\u044b\u0445 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439<\/strong> across pharmaceutical, food, and e-commerce industries<\/p><\/li><li data-start=\"5382\" data-end=\"5455\"><p data-start=\"5384\" data-end=\"5455\"><strong data-start=\"5384\" data-end=\"5420\">Sustainable packaging strategies<\/strong> through optimized material usage<\/p><\/li><\/ul><p data-start=\"5457\" data-end=\"5619\">Moreover, aligning tests with <strong data-start=\"5487\" data-end=\"5500\">ISO 12048<\/strong> not only enhances credibility with partners and clients but also supports global market access for regulated products.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-168e688 e-flex e-con-boxed e-con e-parent\" data-id=\"168e688\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-74ba442 elementor-widget elementor-widget-heading\" data-id=\"74ba442\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-47a1664 e-flex e-con-boxed e-con e-parent\" data-id=\"47a1664\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-dd081dd e-con-full e-flex e-con e-child\" data-id=\"dd081dd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b020a18 elementor-widget elementor-widget-image\" data-id=\"b020a18\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.PCT-01-Compression-Tester_11zon-300x300.webp\" class=\"attachment-medium size-medium wp-image-2283\" alt=\"The packaging compression strength tester about ISO 12048.\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.PCT-01-Compression-Tester_11zon-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.PCT-01-Compression-Tester_11zon-1024x1024.webp 1024w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.PCT-01-Compression-Tester_11zon-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.PCT-01-Compression-Tester_11zon-768x768.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.PCT-01-Compression-Tester_11zon.webp 1080w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-432195b e-con-full e-flex e-con e-child\" data-id=\"432195b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a7846a7 elementor-widget elementor-widget-text-editor\" data-id=\"a7846a7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5642\" data-end=\"6040\">Understanding and applying the principles of <a href=\"https:\/\/www.packqc.com\/standards-iso-12048\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5687\" data-end=\"5700\">ISO 12048<\/strong> <\/a>through an advanced <a href=\"https:\/\/www.pharmacopoeiatest.com\/ru\/plastic-infusion-bottle-compression-test\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5721\" data-end=\"5762\">packaging compression strength tester<\/strong><\/a> like Cell Instruments\u2019 <strong data-start=\"5786\" data-end=\"5796\">PCT-01<\/strong> empowers packaging professionals to make data-driven decisions. From <strong data-start=\"5866\" data-end=\"5891\">medical infusion bags<\/strong> to <strong data-start=\"5895\" data-end=\"5916\">retail containers<\/strong>, compression testing is an essential quality tool for ensuring product safety, regulatory compliance, and brand reputation.<\/p><p data-start=\"6042\" data-end=\"6210\">To learn more or schedule a demonstration, visit <strong data-start=\"6091\" data-end=\"6121\">Cell Instruments Co., Ltd.<\/strong> and explore how we can customize solutions to your specific packaging test requirements.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u0441\u043e\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0442\u0435\u0441\u0442\u0435\u0440\u0430 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438 \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0438 \u043d\u0430 \u0441\u0436\u0430\u0442\u0438\u0435 \u0412 \u0441\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0445 \u0431\u044b\u0441\u0442\u0440\u043e \u043c\u0435\u043d\u044f\u044e\u0449\u0438\u0445\u0441\u044f \u043b\u043e\u0433\u0438\u0441\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0438 \u0444\u0430\u0440\u043c\u0430\u0446\u0435\u0432\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0446\u0435\u043f\u043e\u0447\u043a\u0430\u0445 \u043f\u043e\u0441\u0442\u0430\u0432\u043e\u043a \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0442\u0435\u0441\u0442\u0435\u0440\u0430 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438 \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0438 \u043d\u0430 \u0441\u0436\u0430\u0442\u0438\u0435 \u043d\u0435\u0437\u0430\u043c\u0435\u043d\u0438\u043c\u044b \u0434\u043b\u044f \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u043f\u0440\u043e\u0434\u0443\u043a\u0446\u0438\u0438 \u0438 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u043f\u043e\u0442\u0440\u0435\u0431\u0438\u0442\u0435\u043b\u0435\u0439. \u041a\u043e\u043c\u043f\u0430\u043d\u0438\u044f Cell Instruments \u043f\u043e\u043d\u0438\u043c\u0430\u0435\u0442 \u0432\u0430\u0436\u043d\u043e\u0441\u0442\u044c \u0441\u043e\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u0443\u043f\u0430\u043a\u043e\u0432\u043a\u0438 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u0440\u0435\u0430\u043b\u044c\u043d\u044b\u0445 \u043d\u0430\u0433\u0440\u0443\u0437\u043e\u043a. \u0412 \u044d\u0442\u043e\u0439 \u0441\u0442\u0430\u0442\u044c\u0435 \u043f\u0440\u0435\u0434\u0441\u0442\u0430\u0432\u043b\u0435\u043d \u043f\u0440\u043e\u0444\u0435\u0441\u0441\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0438 \u0432 \u0442\u043e \u0436\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u043d\u044b\u0439 \u043e\u0431\u0437\u043e\u0440 \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u043d\u0430 \u0441\u0436\u0430\u0442\u0438\u0435, [...]...<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2272","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/ru\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Maximizing Package Integrity with Packaging Compression Strength Tester In today\u2019s fast-paced logistics and pharmaceutical supply chains, packaging compression strength tester solutions are indispensable for safeguarding product quality and consumer safety. At Cell Instruments, we understand the significance of maintaining packaging integrity under real-world stress. This article provides a professional yet accessible overview of compression testing,&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/posts\/2272","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/comments?post=2272"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/posts\/2272\/revisions"}],"predecessor-version":[{"id":2342,"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/posts\/2272\/revisions\/2342"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/media?parent=2272"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/categories?post=2272"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ru\/wp-json\/wp\/v2\/tags?post=2272"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}