{"id":2429,"date":"2025-11-06T07:49:46","date_gmt":"2025-11-06T07:49:46","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2429"},"modified":"2025-11-06T07:55:39","modified_gmt":"2025-11-06T07:55:39","slug":"iso-9626","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/ro\/iso-9626\/","title":{"rendered":"ISO 9626"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2429\" class=\"elementor elementor-2429\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5aa439d7 e-flex e-con-boxed e-con e-parent\" data-id=\"5aa439d7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-442ef7 elementor-widget elementor-widget-text-editor\" data-id=\"442ef7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><\/h2>\n<!-- \/wp:heading -->\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8d2ddaa e-flex e-con-boxed e-con e-parent\" data-id=\"8d2ddaa\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1da949 elementor-widget elementor-widget-heading\" data-id=\"a1da949\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 9626 <br><small><small>Testul tubului cu ac din o\u021bel inoxidabil<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28c31c0 e-con-full e-flex e-con e-child\" data-id=\"28c31c0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b07c887 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"b07c887\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"463\" data-end=\"992\"><strong data-start=\"463\" data-end=\"475\">ISO 9626<\/strong> specific\u0103 cerin\u021bele \u0219i <strong data-start=\"507\" data-end=\"557\">metode de testare pentru tuburile cu ac din o\u021bel inoxidabil<\/strong> utilizate \u00een fabricarea dispozitivelor medicale, cum ar fi acele hipodermice \u0219i canulele. Acest standard interna\u021bional garanteaz\u0103 c\u0103 tubulatura utilizat\u0103 \u00een aplica\u021bii medicale \u00eendepline\u0219te cerin\u021be coerente de performan\u021b\u0103 \u0219i siguran\u021b\u0103. Dou\u0103 teste-cheie \u00een conformitate cu ISO 9626 sunt <strong data-start=\"814\" data-end=\"842\">testul de rigiditate a tubului<\/strong> \u0219i <strong data-start=\"851\" data-end=\"892\">rezisten\u021ba tubului la testul de rupere<\/strong>, care sunt esen\u021biale pentru evaluarea integrit\u0103\u021bii mecanice \u0219i a durabilit\u0103\u021bii tuburilor din o\u021bel inoxidabil.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34234b5 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"34234b5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/11\/ISO-9626---Stainless-Steel-Needle-Tubing-Stiffness-and-Break-Strength-Testing.webp\" class=\"attachment-full size-full wp-image-2435\" alt=\"ISO 9626 - Testarea rigidit\u0103\u021bii \u0219i rezisten\u021bei la rupere a tuburilor cu ac din o\u021bel inoxidabil\" srcset=\"\" sizes=\"(max-width: 600px) 100vw, 600px\" data-srcset=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0df13d1 elementor-widget elementor-widget-heading\" data-id=\"0df13d1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ce este ISO 9626?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-185e4a4 elementor-widget elementor-widget-text-editor\" data-id=\"185e4a4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1422\">Standardul ISO 9626, titlu complet <em data-start=\"1346\" data-end=\"1450\">\"Tuburi ac din o\u021bel inoxidabil pentru fabricarea dispozitivelor medicale - Cerin\u021be \u0219i metode de testare\"<\/em>, se aplic\u0103 la <strong data-start=\"1463\" data-end=\"1502\">tub ac rigid din o\u021bel inoxidabil<\/strong> adecvat\u0103 pentru fabricarea acelor hipodermice \u0219i a altor componente ale dispozitivelor medicale.<\/p>\n<p data-start=\"1283\" data-end=\"1620\">ISO 9626 joac\u0103 un rol crucial \u00een asigurarea faptului c\u0103 tuburile din o\u021bel inoxidabil utilizate pentru ace medicale au suficiente <strong data-start=\"1393\" data-end=\"1416\">rezisten\u021b\u0103 mecanic\u0103<\/strong>, <strong data-start=\"1418\" data-end=\"1433\">flexibilitate<\/strong>, \u0219i <strong data-start=\"1439\" data-end=\"1464\">rezisten\u021b\u0103 la oboseal\u0103<\/strong>. Tuburile care nu \u00eendeplinesc aceste cerin\u021be pot duce la \u00eendoirea sau ruperea acului \u00een timpul utiliz\u0103rii, prezent\u00e2nd riscuri pentru pacien\u021bi \u0219i personalul medical.<\/p>\n<p data-start=\"1622\" data-end=\"1645\">Standardul define\u0219te:<\/p>\n<ul>\n<li data-start=\"1648\" data-end=\"1705\"><strong data-start=\"1648\" data-end=\"1675\">Specifica\u021bii materiale<\/strong> pentru tuburi din o\u021bel inoxidabil.<\/li>\n<li data-start=\"1708\" data-end=\"1775\"><strong data-start=\"1708\" data-end=\"1734\">Toleran\u021be dimensionale<\/strong> inclusiv grosimea \u0219i diametrul peretelui.<\/li>\n<li data-start=\"1778\" data-end=\"1853\"><strong data-start=\"1778\" data-end=\"1807\">Teste de propriet\u0103\u021bi mecanice<\/strong>, cum ar fi rigiditatea \u0219i rezisten\u021ba la rupere.<\/li>\n<\/ul>\n<p data-start=\"1855\" data-end=\"1991\">Aderarea la ISO 9626 ajut\u0103 produc\u0103torii s\u0103 men\u021bin\u0103 calitatea constant\u0103 a produselor \u0219i s\u0103 respecte reglement\u0103rile interna\u021bionale privind dispozitivele medicale.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-304c484 elementor-widget elementor-widget-heading\" data-id=\"304c484\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Atunci c\u00e2nd se evalueaz\u0103 tubulatura dispozitivelor medicale, dou\u0103 aspecte de performan\u021b\u0103 mecanic\u0103 sunt deosebit de importante:<\/p>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a08344a elementor-widget elementor-widget-heading\" data-id=\"a08344a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Testul de rigiditate a tubului<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8605095 elementor-widget elementor-widget-text-editor\" data-id=\"8605095\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2030\" data-end=\"2392\">The <strong data-start=\"2034\" data-end=\"2062\">testul de rigiditate a tubului<\/strong> evalueaz\u0103 rezisten\u021ba tubului ac din o\u021bel inoxidabil la deformare atunci c\u00e2nd este aplicat\u0103 o for\u021b\u0103. \u00cen conformitate cu ISO 9626 anexa B, testul presupune sus\u021binerea unei lungimi specificate de tub la ambele capete \u0219i aplicarea unei for\u021be cunoscute <strong data-start=\"2287\" data-end=\"2319\">for\u021b\u0103 descendent\u0103 la centrul s\u0103u<\/strong>. Cantitatea de <strong data-start=\"2335\" data-end=\"2349\">deviere<\/strong> este apoi m\u0103surat\u0103 pentru a determina rigiditatea.<\/p>\n<p data-start=\"2394\" data-end=\"2540\">Acest test ofer\u0103 informa\u021bii despre c\u00e2t de mult se va flexa tubulatura sub sarcin\u0103 - un factor cheie \u00een asigurarea <strong data-start=\"2498\" data-end=\"2537\">stabilitatea acului \u00een timpul inser\u021biei<\/strong>.<\/p>\n<h4 data-start=\"2542\" data-end=\"2567\">Prezentare general\u0103 a procedurii<\/h4>\n<ol data-start=\"2568\" data-end=\"2856\">\n<li data-start=\"2568\" data-end=\"2669\">\n<p data-start=\"2571\" data-end=\"2669\">Tubulatura este plasat\u0103 pe un <strong data-start=\"2597\" data-end=\"2628\">aparat de testare a rigidit\u0103\u021bii<\/strong> cu un interval definit \u00een func\u021bie de dimensiunea sa.<\/p>\n<\/li>\n<li data-start=\"2670\" data-end=\"2768\">\n<p data-start=\"2673\" data-end=\"2768\">A <strong data-start=\"2675\" data-end=\"2694\">piston de \u00eenc\u0103rcare<\/strong> aplic\u0103 o for\u021b\u0103 descendent\u0103 la o vitez\u0103 cuprins\u0103 \u00eentre <strong data-start=\"2739\" data-end=\"2765\">1 mm\/min \u0219i 10 mm\/min<\/strong>.<\/p>\n<\/li>\n<li data-start=\"2769\" data-end=\"2856\">\n<p data-start=\"2772\" data-end=\"2856\">The <strong data-start=\"2776\" data-end=\"2790\">deviere<\/strong> la punctul de \u00eenc\u0103rcare este \u00eenregistrat\u0103 la cea mai apropiat\u0103 <strong data-start=\"2842\" data-end=\"2853\">0,01 mm<\/strong>.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"2858\" data-end=\"3058\">O rigiditate mai mare indic\u0103 o tubulatur\u0103 mai puternic\u0103 care rezist\u0103 la \u00eendoire, \u00een timp ce o rigiditate mai mic\u0103 poate sugera o flexibilitate sporit\u0103. Ambele propriet\u0103\u021bi sunt importante \u00een func\u021bie de aplica\u021bia medical\u0103 preconizat\u0103.<\/p>\n<p data-start=\"3060\" data-end=\"3349\"><strong data-start=\"3060\" data-end=\"3098\">Tester de rigiditate Cell Instruments<\/strong> ofer\u0103 un sistem de \u00eenc\u0103rcare controlat cu precizie \u0219i m\u0103surare digital\u0103 a deplas\u0103rii, \u00een deplin\u0103 conformitate cu cerin\u021bele ISO 9626. Acesta permite laboratoarelor s\u0103 efectueze <strong data-start=\"3260\" data-end=\"3309\">teste de rigiditate a tuburilor cu ace din o\u021bel inoxidabil<\/strong> cu acurate\u021be \u0219i repetabilitate ridicate.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80ffe02 elementor-widget elementor-widget-heading\" data-id=\"80ffe02\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Rezisten\u021ba tubului la rupere<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24288c0 elementor-widget elementor-widget-text-editor\" data-id=\"24288c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3396\" data-end=\"3665\">The <strong data-start=\"3400\" data-end=\"3441\">rezisten\u021ba tubului la testul de rupere<\/strong> (ISO 9626 anexa C) evalueaz\u0103 capacitatea tubului de a rezista la \u00eencovoieri repetate f\u0103r\u0103 a se fisura sau rupe. Acest lucru simuleaz\u0103 condi\u021biile reale \u00een care un ac poate fi supus unor solicit\u0103ri ciclice \u00een timpul manipul\u0103rii sau utiliz\u0103rii.<\/p>\n<h4 data-start=\"3667\" data-end=\"3688\">Principiul de testare<\/h4>\n<p data-start=\"3689\" data-end=\"4019\">Un cap\u0103t al tubului este fixat rigid, iar un <strong data-start=\"3735\" data-end=\"3761\">for\u021b\u0103 de \u00eencovoiere repetat\u0103<\/strong> este aplicat\u0103 la o anumit\u0103 distan\u021b\u0103. Tubulatura este \u00eendoit\u0103 alternativ \u00een direc\u021bii opuse \u00eentr-un unghi definit - de obicei <strong data-start=\"3887\" data-end=\"3920\">25\u00b0 pentru tuburi cu pere\u021bi normali<\/strong>, <strong data-start=\"3922\" data-end=\"3945\">20\u00b0 pentru pere\u021bi sub\u021biri<\/strong>, \u0219i <strong data-start=\"3951\" data-end=\"3987\">15\u00b0 pentru tuburi cu pere\u021bi ultra-sub\u021biri<\/strong> - pentru <strong data-start=\"3994\" data-end=\"4016\">20 de cicluri complete<\/strong>.<\/p>\n<p data-start=\"4021\" data-end=\"4096\">Dup\u0103 testare, tubulatura este examinat\u0103 vizual pentru a detecta orice semne de rupere.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-54ef89d e-flex e-con-boxed e-con e-child\" data-id=\"54ef89d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d72668b elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"d72668b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong data-start=\"4098\" data-end=\"4143\">Instrumente celulare' <a href=\"https:\/\/www.pharmacopoeiatest.com\/ro\/medical-needle-break-resistance-tester\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">Tester de rezisten\u021b\u0103 la rupere<\/a><\/strong> are control programabil al mi\u0219c\u0103rii ciclice \u0219i un sistem precis de deplasare unghiular\u0103, permi\u021b\u00e2nd evaluarea precis\u0103 a <strong data-start=\"4276\" data-end=\"4298\">rezisten\u021b\u0103 la oboseal\u0103<\/strong> \u0219i <strong data-start=\"4303\" data-end=\"4317\">durabilitate<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d56cba elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"5d56cba\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/ro\/medical-needle-break-resistance-tester\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp\" class=\"attachment-large size-large wp-image-1924\" alt=\"Tester de rezisten\u021b\u0103 la ruperea acului medical\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp 1000w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-768x768.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7bc2f44 elementor-widget elementor-widget-heading\" data-id=\"7bc2f44\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00centreb\u0103ri frecvente<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7e535a elementor-widget elementor-widget-toggle\" data-id=\"d7e535a\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2261\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2261\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q1: Ce este ISO 9626?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2261\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2261\"><p data-start=\"5213\" data-end=\"5511\"><strong data-start=\"5241\" data-end=\"5247\">A:<\/strong> <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener\">ISO 9626<\/a> este un standard interna\u021bional care specific\u0103 cerin\u021bele \u0219i metodele de testare pentru <strong data-start=\"5335\" data-end=\"5368\">tub de ac din o\u021bel inoxidabil<\/strong> utilizate \u00een fabricarea dispozitivelor medicale. Acesta define\u0219te parametrii pentru dimensiuni, rigiditate, rezisten\u021b\u0103 la rupere \u0219i performan\u021be mecanice generale.<\/p>\n<p data-start=\"5513\" data-end=\"5787\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2262\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2262\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q2: De ce este important\u0103 rigiditatea tubului de testare?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2262\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2262\"><p data-start=\"5513\" data-end=\"5787\"><strong data-start=\"5570\" data-end=\"5576\">A:<\/strong> The <strong data-start=\"5581\" data-end=\"5609\">testul de rigiditate a tubului<\/strong> asigur\u0103 c\u0103 tubulatura p\u0103streaz\u0103 o rigiditate suficient\u0103 \u0219i nu se \u00eendoaie excesiv sub sarcin\u0103. Este esen\u021bial pentru stabilitatea \u0219i precizia acelor medicale \u00een timpul inser\u021biei.<\/p>\n<p data-start=\"5789\" data-end=\"6071\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2263\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2263\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q3: Ce evalueaz\u0103 testul de rezisten\u021b\u0103 a tuburilor la rupere?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2263\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2263\"><p data-start=\"5789\" data-end=\"6071\"><strong data-start=\"5861\" data-end=\"5867\">A:<\/strong> Acest test m\u0103soar\u0103 capacitatea tubului de a rezista <strong data-start=\"5921\" data-end=\"5948\">cicluri repetate de \u00eendoire<\/strong> f\u0103r\u0103 cr\u0103p\u0103turi. Aceasta ajut\u0103 la confirmarea durabilit\u0103\u021bii \u0219i siguran\u021bei tuburilor medicale din o\u021bel inoxidabil \u00een aplica\u021biile clinice.<\/p>\n<p data-start=\"6073\" data-end=\"6350\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2264\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2264\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q4: Ce echipamente pot efectua teste ISO 9626?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2264\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2264\"><p data-start=\"6073\" data-end=\"6350\"><strong data-start=\"6129\" data-end=\"6135\">A:<\/strong> <strong data-start=\"6136\" data-end=\"6202\">Tester de rigiditate \u0219i tester de rezisten\u021b\u0103 la rupere Cell Instruments<\/strong> sunt special concepute pentru a efectua teste conforme cu ISO 9626, oferind un control precis al for\u021bei, m\u0103surare automat\u0103 \u0219i repetabilitate fiabil\u0103.<\/p>\n<p data-start=\"6352\" data-end=\"6632\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2265\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2265\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">\u00ce5: Cine ar trebui s\u0103 efectueze testele ISO 9626?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2265\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2265\"><p data-start=\"6352\" data-end=\"6632\"><strong data-start=\"6397\" data-end=\"6403\">A:<\/strong> ingineri de control al calit\u0103\u021bii, tehnicieni de laborator \u0219i produc\u0103tori de dispozitive medicale care produc sau valideaz\u0103 <strong data-start=\"6512\" data-end=\"6545\">tub de ac din o\u021bel inoxidabil<\/strong> ar trebui s\u0103 efectueze aceste teste pentru a asigura conformitatea cu standardele interna\u021bionale de siguran\u021b\u0103.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 9626 Stainless Steel Needle Tubing Test ISO 9626 specifies the requirements and test methods for stainless steel needle tubing used in the manufacture of medical devices such as hypodermic needles and cannulas. This international standard ensures that the tubing used in medical applications meets consistent performance and safety requirements. Two key tests under ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2429","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/ro\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 9626 Stainless Steel Needle Tubing Test ISO 9626 specifies the requirements and test methods for stainless steel needle tubing used in the manufacture of medical devices such as hypodermic needles and cannulas. This international standard ensures that the tubing used in medical applications meets consistent performance and safety requirements. Two key tests under ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/comments?post=2429"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2429\/revisions"}],"predecessor-version":[{"id":2445,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2429\/revisions\/2445"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/media?parent=2429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/categories?post=2429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/tags?post=2429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}