{"id":2267,"date":"2025-07-21T07:08:11","date_gmt":"2025-07-21T07:08:11","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2267"},"modified":"2025-07-21T07:21:09","modified_gmt":"2025-07-21T07:21:09","slug":"ampoule-mechanical-strength-tester","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/ro\/ampoule-mechanical-strength-tester\/","title":{"rendered":"Tester de rezisten\u021b\u0103 mecanic\u0103 a fiolelor \u00een conformitate cu ISO 9187"},"content":{"rendered":"<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-fccd8bb\" id=\"introduction\" data-block-id=\"fccd8bb\"><h2 class=\"stk-block-heading__text\">Introducere<\/h2><\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-7387b849 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-uagb-container uagb-block-61ff3f36 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/ro\/category\/product\/ampoule-break-test\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp\" alt=\"tester de rezisten\u021b\u0103 mecanic\u0103 pentru fiole\" class=\"wp-image-2280\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><figcaption class=\"wp-element-caption\">BST-01 Tester de spargere a fiolelor <\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Evaluarea precis\u0103 a <strong>tester de rezisten\u021b\u0103 mecanic\u0103 pentru fiole <\/strong>este esen\u021bial\u0103 \u00een controlul calit\u0103\u021bii produselor farmaceutice. Fiolele de sticl\u0103 utilizate pentru solu\u021bii injectabile trebuie s\u0103 fie suficient de rezistente pentru a men\u021bine sterilitatea \u00een timpul transportului \u0219i depozit\u0103rii, dar suficient de u\u0219or de deschis f\u0103r\u0103 for\u021b\u0103 excesiv\u0103. ISO 9187 ofer\u0103 proceduri de testare standardizate pentru evaluarea acestor calit\u0103\u021bi, \u00een special <strong>m\u0103surarea for\u021bei de rupere pentru fiolele de sticl\u0103<\/strong>. Acest articol v\u0103 ghideaz\u0103 prin procedura complet\u0103 de testare utiliz\u00e2nd <strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/ro\/category\/product\/ampoule-break-test\/\">BST-01 <strong>Tester de rezisten\u021b\u0103 mecanic\u0103 pentru fiole<\/strong><\/a><\/strong> de la Cell Instruments, asigur\u00e2nd conformitatea cu reglement\u0103rile \u0219i siguran\u021ba produselor.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-2c9d7c5\" id=\"breaking-force-measurement-for-glass-ampoules-using-bst-01-ampoule-tester\" data-block-id=\"2c9d7c5\"><h2 class=\"stk-block-heading__text\">M\u0103surarea for\u021bei de rupere pentru fiolele de sticl\u0103 cu ajutorul testerului de fiole BST-01<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>For\u021ba de rupere<\/strong> este un parametru-cheie \u00een integritatea mecanic\u0103 a fiolelor. ISO 9187-1:2010 \u0219i ISO 9187-2 definesc criterii stricte pentru m\u0103surarea acestei for\u021be la constric\u021bia fiolei, marcat\u0103 de obicei cu un inel ceramic sau un pigment colorat.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>BST-01 <strong>Tester de rezisten\u021b\u0103 mecanic\u0103 pentru fiole<\/strong><\/strong> de la Cell Instruments este conceput special pentru acest scop. Acesta ofer\u0103 <strong>m\u0103sur\u0103tori precise \u0219i repetabile ale for\u021bei<\/strong>, \u00een conformitate cu <strong>ISO 7500-1<\/strong> \u0219i <strong>ISO 9187<\/strong> specifica\u021bii. Cu o vitez\u0103 de testare controlat\u0103 de 10 mm\/min \u0219i o gam\u0103 de for\u021be de 200 N, BST-01 asigur\u0103 rezultate fiabile pentru laboratoarele QC \u0219i unit\u0103\u021bile de produc\u021bie.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Caracteristicile principale ale BST-01:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00cen deplin\u0103 conformitate cu metoda de testare ISO 9187<\/li>\n\n\n\n<li>Sistem integrat de m\u0103surare a for\u021bei de trac\u021biune<\/li>\n\n\n\n<li>Vitez\u0103 programabil\u0103 \u0219i \u00eenregistrare a datelor<\/li>\n\n\n\n<li>Ideal pentru <strong>m\u0103surarea for\u021bei de rupere pentru fiolele de sticl\u0103<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Utilizarea testerului BST-01 nu numai c\u0103 \u00eembun\u0103t\u0103\u021be\u0219te eficien\u021ba, dar ajut\u0103 \u0219i la detectarea <strong>recoacere inconsecvent\u0103<\/strong> sau <strong>rezisten\u021b\u0103 hidrolitic\u0103 slab\u0103<\/strong>, ceea ce ar putea compromite siguran\u021ba pacien\u021bilor.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-66f05dd\" id=\"a-href-https-www-pharmacopoeiatest-com-iso-9187-1-iso-9187-a-standards-technical-testing-guidelines\" data-block-id=\"66f05dd\"><h2 class=\"stk-block-heading__text\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/ro\/iso-9187-1\/\">ISO 9187<\/a> Standarde: Orient\u0103ri privind testarea tehnic\u0103<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 9187 prezint\u0103 metodologia \u0219i criteriile de acceptare pentru evaluarea <strong>rezisten\u021ba mecanic\u0103 a fiolelor<\/strong>. Mai jos sunt prezentate elementele critice pe care trebuie s\u0103 le respecta\u021bi:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Rezisten\u021b\u0103 hidrolitic\u0103<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ampulele trebuie s\u0103 \u00eendeplineasc\u0103 <strong>ISO 4802 HC1<\/strong> clasa de rezisten\u021b\u0103 hidrolitic\u0103, asigur\u00e2nd durabilitatea suprafe\u021bei interne \u00eempotriva solu\u021biilor apoase.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Calitatea recoacerii<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ampulele nu trebuie s\u0103 prezinte o \u00eent\u00e2rziere optic\u0103 peste <strong>50 nm\/mm grosime sticl\u0103<\/strong>. Recoacerea necorespunz\u0103toare cre\u0219te tensiunea intern\u0103, duc\u00e2nd la rupere \u00een timpul manipul\u0103rii sau transportului.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Procedura de testare a for\u021bei de rupere<\/h3>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-dda3e97\" data-block-id=\"dda3e97\"><p class=\"stk-block-text__text\">    <strong>1.Aparat:<\/strong> Folosi\u021bi un aparat de \u00eencercare la trac\u021biune \u00een conformitate cu <strong>ISO 7500-1<\/strong>, cum ar fi <strong>BST-01 Tester de rezisten\u021b\u0103 mecanic\u0103 pentru fiole<\/strong>.<br>    <strong>2.Viteza de testare:<\/strong> 10 mm\/min sau o putere echivalent\u0103 de 20 N\/s.<br>    <strong>3.Force Range:<\/strong> Cel pu\u021bin 200 N.<br>    <strong>4.Preg\u0103tirea probei:<\/strong><br>             Stare la <strong>20 \u00b1 5 \u00b0C<\/strong>.<br>             Selecta\u021bi probele \u00een func\u021bie de <strong>ISO 2859-1<\/strong>, nivelul de inspec\u021bie S-4.<br>    <strong>5.Setup:<\/strong><br>            Pozi\u021biona\u021bi fiola \u00eentre dou\u0103 bare.<br>            Aplica\u021bi o for\u021b\u0103 la 90\u00b0 fa\u021b\u0103 de axa sa.<br>            Ruperea trebuie s\u0103 fie curat\u0103 \u0219i s\u0103 se \u00eenregistreze for\u021ba.<\/p><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Pozi\u021bia \u0219i stabilitatea punctului de rupere (ISO 9187-2)<\/h3>\n\n\n\n<figure class=\"wp-block-embed alignright is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"ISO 9187-1 tester de spargere a fiolelor BST-01\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/fL78KBZwj3g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-74b8b2e\" data-block-id=\"74b8b2e\"><p class=\"stk-block-text__text\">                                               Punctul de rupere marcat prin culoare trebuie s\u0103 fie <strong>centrat \u00b11 mm<\/strong>.<br>                                               Trebuie s\u0103 reziste:<br>                                                   <strong>30 de minute la 120 \u00b0C<\/strong>, apoi imersiune \u00een <strong>30 \u00b0C ap\u0103<\/strong><br>                                                   <strong>Cicluri de sterilizare \u0219i solven\u021bi de cur\u0103\u021bare<\/strong><br>                                               Nerespectarea acestor indica\u021bii poate duce la o for\u021b\u0103 de rupere excesiv\u0103, f\u0103c\u00e2nd fiola nesigur\u0103 sau neconform\u0103.<\/p><\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-d535f6f\" id=\"why-mechanical-strength-testing-matters\" data-block-id=\"d535f6f\"><h2 class=\"stk-block-heading__text\">                De ce este important\u0103 testarea rezisten\u021bei mecanice<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Performan\u021b\u0103 <strong>test de rezisten\u021b\u0103 mecanic\u0103 a fiolei<\/strong> nu \u00eenseamn\u0103 doar adoptarea unui regulament. Aceasta asigur\u0103:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Siguran\u021ba pacien\u021bilor:<\/strong> prevenirea particulelor de sticl\u0103 sau a spargerii for\u021bate<\/li>\n\n\n\n<li><strong>Consisten\u021ba fabrica\u021biei:<\/strong> detectarea timpurie a defectelor<\/li>\n\n\n\n<li><strong>Conformitatea cu reglement\u0103rile:<\/strong> evitarea respingerilor \u0219i a rechem\u0103rilor<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Exemplu din lumea real\u0103:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">O uzin\u0103 farmaceutic\u0103 de top care utilizeaz\u0103 BST-01 a ob\u021binut o <strong>Reducere 30%<\/strong> \u00een reclama\u021biile legate de spargerea fiolelor dup\u0103 standardizarea testelor conforme cu ISO 9187.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-25932c4\" id=\"choosing-the-right-ampoule-mechanical-strength-tester\" data-block-id=\"25932c4\"><h2 class=\"stk-block-heading__text\">Alegerea testerului corect de rezisten\u021b\u0103 mecanic\u0103 a fiolelor.<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Cell Instruments este specializat\u0103 \u00een sisteme de testare mecanic\u0103 de \u00eenalt\u0103 precizie. Modelul <strong>BST-01 Tester de rezisten\u021b\u0103 mecanic\u0103 pentru fiole<\/strong> este optimizat pentru <strong>test de rezisten\u021b\u0103 mecanic\u0103 a fiolei<\/strong> \u0219i sprijin\u0103 automatizarea, trasabilitatea datelor \u0219i u\u0219urin\u021ba de utilizare a operatorului.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cu zeci de ani de experien\u021b\u0103 \u00een <strong>testarea ambalajelor dispozitivelor medicale \u0219i farmaceutice<\/strong>, Cell Instruments ofer\u0103 solu\u021bii personalizate pentru:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Controlul calit\u0103\u021bii fiolelor injectabile<\/li>\n\n\n\n<li>Caracterizarea materialelor<\/li>\n\n\n\n<li>Configura\u021bii de testare automat\u0103 personalizate<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dac\u0103 fluxul dvs. de control al calit\u0103\u021bii implic\u0103 fiole de sticl\u0103, BST-01 ofer\u0103 <strong>acurate\u021be, repetabilitate \u0219i conformitate<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-cea0f97\" id=\"conclusion\" data-block-id=\"cea0f97\"><h2 class=\"stk-block-heading__text\">Concluzie<\/h2><\/div>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-08e63b8\" data-block-id=\"08e63b8\"><style>.stk-08e63b8{margin-bottom:0px !important}.stk-08e63b8 .stk-block-text__text{text-shadow:none !important}<\/style><p class=\"stk-block-text__text\">Asigurarea rezisten\u021bei mecanice a fiolelor este esen\u021bial\u0103 pentru integritatea farmaceutic\u0103 \u0219i siguran\u021ba pacien\u021bilor. Prin aderarea la <a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>ISO 9187<\/strong> <\/a>\u0219i utilizarea de echipamente avansate, cum ar fi <strong>BST-01 Tester de rezisten\u021b\u0103 mecanic\u0103 pentru fiole<\/strong>, produc\u0103torii pot verifica cu \u00eencredere <strong>m\u0103surarea for\u021bei de rupere pentru fiolele de sticl\u0103<\/strong>. Testarea precis\u0103 nu numai c\u0103 garanteaz\u0103 calitatea produselor, dar spore\u0219te \u0219i conformitatea cu reglement\u0103rile \u0219i \u00eencrederea clien\u021bilor.<br>Pentru laboratoarele \u0219i produc\u0103torii care caut\u0103 solu\u021bii de testare fiabile \u0219i conforme cu ISO, <strong>Cell Instruments' BST-01<\/strong> este o alegere dovedit\u0103 pentru a v\u0103 sprijini programul de testare a fiolelor.<\/p><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Accurate evaluation of ampoule mechanical strength tester is critical in pharmaceutical quality control. Glass ampoules used for injectable solutions must be strong enough to maintain sterility during transportation and storage, yet easy enough to break open without excessive force. ISO 9187 provides standardized test procedures to assess these qualities, especially breaking force measurement for glass [&hellip;]<\/p>","protected":false},"author":1,"featured_media":2280,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2267","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"thumbnail":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp",150,150,true],"medium":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp",300,300,true],"medium_large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"1536x1536":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"2048x2048":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"trp-custom-language-flag":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",12,12,false]},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/ro\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Accurate evaluation of ampoule mechanical strength tester is critical in pharmaceutical quality control. Glass ampoules used for injectable solutions must be strong enough to maintain sterility during transportation and storage, yet easy enough to break open without excessive force. ISO 9187 provides standardized test procedures to assess these qualities, especially breaking force measurement for glass&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/comments?post=2267"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2267\/revisions"}],"predecessor-version":[{"id":2300,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2267\/revisions\/2300"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/media\/2280"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/media?parent=2267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/categories?post=2267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/tags?post=2267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}