{"id":2124,"date":"2025-05-23T08:22:54","date_gmt":"2025-05-23T08:22:54","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2124"},"modified":"2025-05-23T08:22:55","modified_gmt":"2025-05-23T08:22:55","slug":"iso-9187-1","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/ro\/iso-9187-1\/","title":{"rendered":"ISO 9187-1"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2124\" class=\"elementor elementor-2124\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a8d4331 e-con-full e-flex e-con e-parent\" data-id=\"a8d4331\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9697cf0 elementor-widget elementor-widget-heading\" data-id=\"9697cf0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Test de \u00eendoire \u00een trei puncte a fiolei<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d5a4a9d elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"d5a4a9d\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-71786c6 elementor-widget elementor-widget-heading\" data-id=\"71786c6\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 9187-1<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-288a03b e-flex e-con-boxed e-con e-parent\" data-id=\"288a03b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4f75139 elementor-widget elementor-widget-text-editor\" data-id=\"4f75139\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"443\" data-end=\"845\"><em data-start=\"443\" data-end=\"455\">ISO 9187-1<\/em> este un standard interna\u021bional esen\u021bial care define\u0219te cerin\u021bele pentru fiolele de sticl\u0103 utilizate pentru medicamentele injectabile. Asigurarea c\u0103 aceste fiole \u00eendeplinesc standardele mecanice \u0219i chimice necesare este esen\u021bial\u0103 at\u00e2t pentru siguran\u021ba pacien\u021bilor, c\u00e2t \u0219i pentru conformitatea cu reglement\u0103rile. Acest standard define\u0219te specifica\u021biile pentru rezisten\u021ba hidrolitic\u0103, calitatea recoacerii \u0219i, cel mai important, <strong data-start=\"821\" data-end=\"844\">for\u021ba de rupere a fiolei<\/strong>.<\/p><p data-start=\"847\" data-end=\"1237\">\u00cen ambalarea produselor farmaceutice \u0219i fabricarea dispozitivelor medicale, \u00een\u021belegerea \u0219i aplicarea ISO 9187-1 este vital\u0103 pentru prevenirea riscurilor asociate cu integritatea slab\u0103 a fiolelor - cum ar fi contaminarea cu cioburi de sticl\u0103 sau ruperea imprevizibil\u0103 \u00een timpul administr\u0103rii medicamentului. Testarea adecvat\u0103, inclusiv <strong data-start=\"1130\" data-end=\"1158\">\u00eencercare de \u00eencovoiere \u00een trei puncte<\/strong> \u0219i <strong data-start=\"1163\" data-end=\"1191\">testul for\u021bei de rupere a fiolei<\/strong>, garanteaz\u0103 o calitate \u0219i o utilitate constante.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a63edf elementor-widget elementor-widget-heading\" data-id=\"9a63edf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Principalele cerin\u021be ale ISO 9187-1<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-157872d elementor-widget elementor-widget-text-editor\" data-id=\"157872d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1280\" data-end=\"1351\">ISO 9187-1:2010 specific\u0103 trei criterii principale de performan\u021b\u0103 pentru fiole:<\/p><ul><li data-start=\"1355\" data-end=\"1489\"><strong data-start=\"1355\" data-end=\"1381\">Rezisten\u021b\u0103 hidrolitic\u0103:<\/strong> Suprafa\u021ba intern\u0103 a fiolelor trebuie s\u0103 respecte clasificarea sticlei ISO 4802 HC 1 pentru a asigura stabilitatea chimic\u0103.<\/li><li data-start=\"1492\" data-end=\"1647\"><strong data-start=\"1492\" data-end=\"1514\">Calitatea de recoacere:<\/strong> Ampolele nu trebuie s\u0103 prezinte o \u00eent\u00e2rziere optic\u0103 mai mare de 50 nm pe mm de sticl\u0103, prevenind tensiunile interne care ar putea afecta durabilitatea.<\/li><li data-start=\"1650\" data-end=\"1792\"><strong data-start=\"1650\" data-end=\"1669\">For\u021ba de rupere:<\/strong> Ampulele trebuie s\u0103 se rup\u0103 curat \u0219i previzibil \u00eentr-un punct slab predefinit, marcat de obicei printr-un inel ceramic sau o linie marcat\u0103.<\/li><\/ul><p data-start=\"1794\" data-end=\"1932\">E\u0219ecul \u00een oricare dintre aceste categorii poate duce la rechemarea produselor, r\u0103nirea utilizatorilor sau compromiterea sterilit\u0103\u021bii - toate acestea put\u00e2nd fi evitate cu teste solide.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e9081f elementor-widget elementor-widget-heading\" data-id=\"6e9081f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testul for\u021bei de rupere a fiolelor: Asigurarea unei deschideri sigure<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2af776b elementor-widget elementor-widget-text-editor\" data-id=\"2af776b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1992\" data-end=\"2303\">The <strong data-start=\"1996\" data-end=\"2024\">testul for\u021bei de rupere a fiolei<\/strong> este o parte fundamental\u0103 a conformit\u0103\u021bii cu ISO 9187-1. Acest test evalueaz\u0103 for\u021ba mecanic\u0103 necesar\u0103 pentru a rupe fiola la punctul de rupere desemnat. Procesul implic\u0103 utilizarea unei ma\u0219ini de testare la trac\u021biune, cum ar fi Cell Instruments' <strong data-start=\"2254\" data-end=\"2264\">BST-01<\/strong>, pentru a m\u0103sura \u0219i \u00eenregistra for\u021ba maxim\u0103.<\/p><p data-start=\"2305\" data-end=\"2342\">Parametrii cheie pentru acest test includ:<\/p><ul><li data-start=\"2346\" data-end=\"2381\"><strong data-start=\"2346\" data-end=\"2361\">Viteza de testare:<\/strong> Tipic 10 mm\/min<\/li><li data-start=\"2384\" data-end=\"2424\"><strong data-start=\"2384\" data-end=\"2412\">Domeniul de m\u0103surare a for\u021bei:<\/strong> P\u00e2n\u0103 la 200 N<\/li><li data-start=\"2427\" data-end=\"2484\"><strong data-start=\"2427\" data-end=\"2456\">Condi\u021bionarea temperaturii:<\/strong> 20 \u00b0C \u00b1 5 \u00b0C \u00eenainte de testare<\/li><li data-start=\"2487\" data-end=\"2591\"><strong data-start=\"2487\" data-end=\"2497\">Configurare:<\/strong> Flaconul este \u00eenc\u0103rcat \u00eentre dou\u0103 bare metalice; for\u021ba este aplicat\u0103 perpendicular pe axa sa.<\/li><\/ul><p data-start=\"2593\" data-end=\"2765\">O rupere consecvent\u0103 \u0219i previzibil\u0103 confirm\u0103 at\u00e2t calitatea fabrica\u021biei, c\u00e2t \u0219i siguran\u021ba utilizatorului. O for\u021b\u0103 de rupere excesiv\u0103 sau inconsecvent\u0103 poate indica o recoacere slab\u0103 sau probleme structurale.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f2e137 elementor-widget elementor-widget-heading\" data-id=\"1f2e137\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testul de \u00eendoire \u00een trei puncte: Evaluarea rezisten\u021bei la flexiune<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0481648 elementor-widget elementor-widget-text-editor\" data-id=\"0481648\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2831\" data-end=\"3116\">De\u0219i nu este metoda principal\u0103 conform ISO 9187-1, metoda <strong data-start=\"2885\" data-end=\"2913\">\u00eencercare de \u00eencovoiere \u00een trei puncte<\/strong> este utilizat pentru a analiza flexibilitatea mecanic\u0103 \u0219i fragilitatea materialelor pentru fiole, \u00een special \u00een timpul cercet\u0103rii \u0219i dezvolt\u0103rii \u0219i al analizei defec\u021biunilor. Aceasta ajut\u0103 la identificarea sl\u0103biciunilor structurale \u0219i la optimizarea compozi\u021biei materialului.<\/p><p data-start=\"3118\" data-end=\"3392\">\u00cen acest test, fiola este sus\u021binut\u0103 \u00een dou\u0103 puncte, \u00een timp ce for\u021ba este aplicat\u0103 \u00een punctul median. Datele rezultate arat\u0103 c\u00e2t de mult stres poate suporta fiola \u00eenainte de a se rupe. Aceste informa\u021bii sunt utile la proiectarea fiolelor cu o grosime optim\u0103 a peretelui \u0219i profile de rupere.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a59304a elementor-widget elementor-widget-heading\" data-id=\"a59304a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">De ce s\u0103 utiliza\u021bi BST-01 de la Cell Instruments pentru conformitatea cu ISO 9187-1?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0e317f0 e-con-full e-flex e-con e-child\" data-id=\"0e317f0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b06973d elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"b06973d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3464\" data-end=\"3681\">Pentru a ob\u021bine rezultate repetabile \u0219i precise <strong data-start=\"3499\" data-end=\"3527\">testul for\u021bei de rupere a fiolei<\/strong> rezultate, Cell Instruments ofer\u0103 <strong data-start=\"3565\" data-end=\"3597\">BST-01 <a href=\"https:\/\/www.pharmacopoeiatest.com\/ro\/ampoule-breaking-tester\/\" target=\"_blank\" rel=\"noopener\">Tester de rezisten\u021b\u0103 la rupere<\/a><\/strong>. Acest instrument este construit special pentru conformitatea cu ISO 9187-1 \u0219i GB 2637 \u0219i dispune de:<\/p><ul><li data-start=\"3685\" data-end=\"3749\"><strong data-start=\"3685\" data-end=\"3714\">Celul\u0103 de \u00eenc\u0103rcare de \u00eenalt\u0103 precizie:<\/strong> Capteaz\u0103 valorile exacte ale for\u021bei de rupere.<\/li><li data-start=\"3752\" data-end=\"3824\"><strong data-start=\"3752\" data-end=\"3781\">Fitinguri interschimbabile:<\/strong> Suport\u0103 fiole de la 1 la 30 ml.<\/li><li data-start=\"3827\" data-end=\"3921\"><strong data-start=\"3827\" data-end=\"3867\">Control PLC \u0219i interfa\u021b\u0103 touchscreen:<\/strong> Ra\u021bionalizeaz\u0103 opera\u021biunile cu ajutorul automatiz\u0103rii u\u0219or de utilizat.<\/li><li data-start=\"3924\" data-end=\"4007\"><strong data-start=\"3924\" data-end=\"3954\">Set\u0103ri de vitez\u0103 reglabile:<\/strong> Personaliza\u021bi parametrii de testare pentru diferite tipuri de fiole.<\/li><li data-start=\"4010\" data-end=\"4078\"><strong data-start=\"4010\" data-end=\"4041\">Caracteristici de siguran\u021b\u0103 integrate:<\/strong> Preveni\u021bi r\u0103nirea din cauza fragmentelor de sticl\u0103.<\/li><li data-start=\"4081\" data-end=\"4167\"><strong data-start=\"4081\" data-end=\"4114\">Software op\u021bional \u0219i imprimare:<\/strong> Permite exportul de date \u0219i generarea imediat\u0103 de rapoarte.<\/li><\/ul><p data-start=\"4169\" data-end=\"4380\">BST-01 \u00eembun\u0103t\u0103\u021be\u0219te semnificativ fluxurile de lucru pentru controlul calit\u0103\u021bii \u00een <strong data-start=\"4232\" data-end=\"4260\">ambalaje farmaceutice<\/strong>, <strong data-start=\"4262\" data-end=\"4291\">produc\u021bia de dispozitive medicale<\/strong>, \u0219i <strong data-start=\"4297\" data-end=\"4317\">Mediile de cercetare \u0219i dezvoltare<\/strong> prin asigurarea faptului c\u0103 fiecare fiol\u0103 \u00eendepline\u0219te criterii mecanice stricte.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73c96d5 elementor-widget elementor-widget-image\" data-id=\"73c96d5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/ro\/ampoule-breaking-tester\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2024\/03\/Ampoule-Breaking-Tester.jpg\" class=\"attachment-large size-large wp-image-1498\" alt=\"tester de \u00eencovoiere \u00een trei puncte a fiolei\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2024\/03\/Ampoule-Breaking-Tester.jpg 1000w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2024\/03\/Ampoule-Breaking-Tester-300x300.jpg 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2024\/03\/Ampoule-Breaking-Tester-150x150.jpg 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2024\/03\/Ampoule-Breaking-Tester-768x768.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Tester de spargere a fiolelor ISO 9187-1<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f14933 elementor-widget elementor-widget-heading\" data-id=\"7f14933\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Concluzie: Conformitatea cu ISO 9187-1 este ne-negociabil\u0103<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6de918d elementor-widget elementor-widget-text-editor\" data-id=\"6de918d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4444\" data-end=\"4747\">Conformitatea cu <a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noopener\"><em data-start=\"4459\" data-end=\"4471\">ISO 9187-1<\/em><\/a> asigur\u0103 c\u0103 fiolele injectabile sunt sigure, func\u021bionale \u0219i consecvente. Prin efectuarea de teste standardizate, cum ar fi <strong data-start=\"4585\" data-end=\"4613\">testul for\u021bei de rupere a fiolei<\/strong> \u0219i <strong data-start=\"4622\" data-end=\"4650\">\u00eencercare de \u00eencovoiere \u00een trei puncte<\/strong>, produc\u0103torii pot verifica fiabilitatea produselor lor \u0219i pot evita e\u0219ecurile critice de calitate.<\/p><p data-start=\"4749\" data-end=\"5074\">Cu instrumente de precizie precum <strong data-start=\"4779\" data-end=\"4789\">BST-01<\/strong> de la <strong data-start=\"4795\" data-end=\"4815\">Instrumente celulare<\/strong>, profesioni\u0219tii pot \u00eendeplini cu \u00eencredere cerin\u021bele ISO \u0219i pot proteja integritatea produselor. Indiferent dac\u0103 lucra\u021bi \u00een domeniul produc\u021biei farmaceutice, al test\u0103rii de reglementare sau al cercet\u0103rii \u0219i dezvolt\u0103rii, testarea exact\u0103 a performan\u021bei fiolelor este esen\u021bial\u0103 pentru ob\u021binerea conformit\u0103\u021bii \u0219i protejarea utilizatorilor finali.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Test de \u00eendoire \u00een trei puncte a fiolei ISO 9187-1 ISO 9187-1 este un standard interna\u021bional esen\u021bial care define\u0219te cerin\u021bele pentru fiolele de sticl\u0103 utilizate pentru medicamentele injectabile. Asigurarea c\u0103 aceste fiole \u00eendeplinesc standardele mecanice \u0219i chimice necesare este esen\u021bial\u0103 at\u00e2t pentru siguran\u021ba pacien\u021bilor, c\u00e2t \u0219i pentru conformitatea cu reglement\u0103rile. Acest standard define\u0219te specifica\u021biile pentru rezisten\u021ba hidrolitic\u0103, calitatea recoacerii \u0219i cele mai [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2124","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/ro\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Ampoule Three Point Bend Test ISO 9187-1 ISO 9187-1 is a critical international standard that defines the requirements for glass ampoules used for injectable medications. Ensuring these ampoules meet the required mechanical and chemical standards is essential for both patient safety and regulatory compliance. This standard outlines specifications for hydrolytic resistance, annealing quality, and most&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2124","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/comments?post=2124"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2124\/revisions"}],"predecessor-version":[{"id":2132,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2124\/revisions\/2132"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/media?parent=2124"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/categories?post=2124"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/tags?post=2124"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}