{"id":2105,"date":"2025-05-07T06:56:33","date_gmt":"2025-05-07T06:56:33","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2105"},"modified":"2025-05-07T06:56:34","modified_gmt":"2025-05-07T06:56:34","slug":"lla-collar-torque-resistance","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/ro\/lla-collar-torque-resistance\/","title":{"rendered":"Rezisten\u021ba la torsiune a colierului LLA"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2105\" class=\"elementor elementor-2105\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f46df2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f46df2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2444a elementor-widget elementor-widget-heading\" data-id=\"7b2444a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Rezisten\u021ba la torsiune a colierului LLA<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edec19 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8edec19\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e4ea1f elementor-widget elementor-widget-heading\" data-id=\"0e4ea1f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Anexa G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3053d41 e-flex e-con-boxed e-con e-parent\" data-id=\"3053d41\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d4d20a elementor-widget elementor-widget-text-editor\" data-id=\"7d4d20a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"376\" data-end=\"978\">\u00cen produc\u021bia farmaceutic\u0103, asigurarea integrit\u0103\u021bii mecanice a seringilor preumplute este esen\u021bial\u0103 pentru siguran\u021ba \u0219i performan\u021ba produsului. Un factor cheie \u00een aceast\u0103 integritate este <strong data-start=\"567\" data-end=\"599\">Rezisten\u021ba la cuplu a gulerului LLA<\/strong>, care m\u0103soar\u0103 rezisten\u021ba gulerului adaptorului Luer Lock (LLA) la torsiune. Aceast\u0103 proprietate garanteaz\u0103 c\u0103 gulerul poate rezista for\u021bei de rota\u021bie atunci c\u00e2nd personalul medical ata\u0219eaz\u0103 butuci de ac sau conectori compatibili. Efectuarea acestui test \u00een conformitate cu <em data-start=\"862\" data-end=\"875\">ISO 11040-4<\/em> \u0219i <em data-start=\"880\" data-end=\"890\">Anexa G4<\/em> ajut\u0103 produc\u0103torii s\u0103 respecte reglement\u0103rile \u0219i s\u0103 ofere produse sigure \u0219i func\u021bionale.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0043965 elementor-widget elementor-widget-heading\" data-id=\"0043965\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rezisten\u021ba la torsiune a colierului LLA \u0219i importan\u021ba acesteia<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef59016 elementor-widget elementor-widget-text-editor\" data-id=\"ef59016\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"985\" data-end=\"1456\"><strong data-start=\"1047\" data-end=\"1079\">Rezisten\u021ba la cuplu a gulerului LLA<\/strong> se refer\u0103 la capacitatea colierului adaptor Luer Lock de pe o sering\u0103 de a rezista la rotire sau sl\u0103bire atunci c\u00e2nd se aplic\u0103 un cuplu. \u00cen utilizarea real\u0103, acest lucru simuleaz\u0103 stresul mecanic exercitat atunci c\u00e2nd un clinician conecteaz\u0103 un dispozitiv compatibil Luer-lock. E\u0219ecul rezisten\u021bei la cuplu poate duce la scurgeri, administrarea necorespunz\u0103toare a medicamentului sau contaminare - riscuri grave \u00een mediul clinic.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77afa8a elementor-widget elementor-widget-heading\" data-id=\"77afa8a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standard de testare a seringilor - ISO 11040-4 Anexa G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f4cc74 e-con-full e-flex e-con e-child\" data-id=\"9f4cc74\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0879ad7 elementor-widget elementor-widget-text-editor\" data-id=\"0879ad7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1463\" data-end=\"1902\">The <strong data-start=\"1525\" data-end=\"1540\">ISO 11040-4<\/strong> standard, intitulat <em data-start=\"1558\" data-end=\"1673\">Seringi preumplute - Partea 4: Butoaie de sticl\u0103 pentru injectabile \u0219i seringi subansamblate sterilizate gata de umplere<\/em>define\u0219te metode de testare riguroase pentru a asigura fiabilitatea produsului. <em data-start=\"1737\" data-end=\"1747\">Anexa G4<\/em> detaliaz\u0103 \u00een mod specific metoda de evaluare <strong data-start=\"1794\" data-end=\"1826\">Rezisten\u021ba la cuplu a gulerului LLA<\/strong>, ceea ce \u00eel face indispensabil pentru produc\u0103torii implica\u021bi \u00een <strong data-start=\"1882\" data-end=\"1901\">testarea seringii<\/strong>.<\/p><p class=\"\" data-start=\"1904\" data-end=\"1941\">Punctele cheie din anexa G4 includ:<\/p><ul><li data-start=\"1944\" data-end=\"2066\"><strong data-start=\"1944\" data-end=\"1963\">Principiul de testare:<\/strong> Verific\u0103 dac\u0103 gulerul LLA poate rezista la cuplu \u00een timpul ata\u0219\u0103rii unui racord conic Luer standard 6%.<\/li><li data-start=\"2069\" data-end=\"2129\"><strong data-start=\"2069\" data-end=\"2099\">Rata de e\u0219antionare recomandat\u0103:<\/strong> 500 Hz pentru m\u0103sur\u0103tori de v\u00e2rf.<\/li><li data-start=\"2132\" data-end=\"2186\"><strong data-start=\"2132\" data-end=\"2160\">Standard Viteza de rota\u021bie:<\/strong> 20 rpm sau dup\u0103 cum s-a convenit.<\/li><li data-start=\"2189\" data-end=\"2255\"><strong data-start=\"2189\" data-end=\"2212\">Ie\u0219ire de m\u0103surare:<\/strong> Cuplu maxim la ini\u021bierea mi\u0219c\u0103rii gulerului.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1ed627 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"d1ed627\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"236\" height=\"361\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp\" class=\"attachment-full size-full wp-image-2107\" alt=\"Rezisten\u021ba la torsiune a colierului LLA - Testarea seringii ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp 236w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing-196x300.webp 196w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47df98e elementor-widget elementor-widget-heading\" data-id=\"47df98e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Echipament de testare pentru rezisten\u021ba la torsiune a colierului LLA<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4baaf8e elementor-widget elementor-widget-text-editor\" data-id=\"4baaf8e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2262\" data-end=\"2400\">Efectuarea testului necesit\u0103 instrumenta\u021bie de precizie. Configura\u021bia standard include:<\/p><ul><li data-start=\"2403\" data-end=\"2556\"><strong data-start=\"2403\" data-end=\"2441\">Tester de cuplu cu dispozitiv de rota\u021bie<\/strong>: Trebuie s\u0103 fie capabil s\u0103 detecteze cuplul de v\u00e2rf cu o rezolu\u021bie de <strong data-start=\"2507\" data-end=\"2519\">0,05 Ncm<\/strong>, intervalul ideal fiind <strong data-start=\"2539\" data-end=\"2555\">p\u00e2n\u0103 la 35 Ncm<\/strong>.<\/li><li data-start=\"2559\" data-end=\"2630\"><strong data-start=\"2559\" data-end=\"2581\">LLA Collar Gripper<\/strong>: Prinde \u00een siguran\u021b\u0103 gulerul f\u0103r\u0103 a-l deteriora.<\/li><li data-start=\"2633\" data-end=\"2737\"><strong data-start=\"2633\" data-end=\"2661\">Suport de sering\u0103 rotativ<\/strong>: Permite rotirea precis\u0103 \u0219i constant\u0103 a seringii sau a dispozitivului de \u00eenchidere.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0058def elementor-widget elementor-widget-heading\" data-id=\"0058def\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ghid pas cu pas pentru efectuarea testului<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e82ef56 elementor-widget elementor-widget-text-editor\" data-id=\"e82ef56\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2938\" data-end=\"3119\">Profesioni\u0219tii \u00een controlul calit\u0103\u021bii pot urma ace\u0219ti pa\u0219i pentru a asigura testarea corect\u0103 \u0219i standardizat\u0103 a <strong data-start=\"3086\" data-end=\"3118\">Rezisten\u021ba la cuplu a gulerului LLA<\/strong>:<\/p><ol><li data-start=\"3124\" data-end=\"3195\"><strong data-start=\"3124\" data-end=\"3134\">Introduce\u021bi<\/strong> seringa subansamblat\u0103 sterilizat\u0103 \u00een suportul seringii.<\/li><li data-start=\"3199\" data-end=\"3231\"><strong data-start=\"3199\" data-end=\"3209\">Elimina\u021bi<\/strong> capacul v\u00e2rfului manual.<\/li><li data-start=\"3235\" data-end=\"3297\"><strong data-start=\"3235\" data-end=\"3244\">Munte<\/strong> clema de prindere a colierului LLA bine fixat\u0103 pe colierul LLA.<\/li><li data-start=\"3301\" data-end=\"3355\"><strong data-start=\"3301\" data-end=\"3309\">Zero<\/strong> celula de cuplu pentru a elimina cuplul de pre\u00eenc\u0103rcare.<\/li><li data-start=\"3359\" data-end=\"3416\"><strong data-start=\"3359\" data-end=\"3366\">Set<\/strong> viteza de rota\u021bie la 20 rpm (sau dup\u0103 caz).<\/li><li data-start=\"3420\" data-end=\"3509\"><strong data-start=\"3420\" data-end=\"3432\">Ini\u021biere<\/strong> testul prin rotirea seringii sau a dispozitivului de \u00eenchidere cu 90\u00b0 \u00een direc\u021bia indicat\u0103.<\/li><li data-start=\"3513\" data-end=\"3568\"><strong data-start=\"3513\" data-end=\"3523\">\u00cenregistrare<\/strong> cuplul maxim atunci c\u00e2nd \u00eencepe mi\u0219carea gulerului.<\/li><\/ol><p class=\"\" data-start=\"3570\" data-end=\"3675\">Aceast\u0103 valoare a cuplului reflect\u0103 <strong data-start=\"3601\" data-end=\"3623\">rezisten\u021b\u0103 maxim\u0103<\/strong> oferite de gulerul LLA \u00een condi\u021bii de stres opera\u021bional.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d445bbc e-con-full e-flex e-con e-child\" data-id=\"d445bbc\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-defbeb6 e-con-full e-flex e-con e-child\" data-id=\"defbeb6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c54c92 elementor-widget elementor-widget-heading\" data-id=\"1c54c92\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Raportarea testelor \u0219i controlul calit\u0103\u021bii<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-669ef67 elementor-widget elementor-widget-text-editor\" data-id=\"669ef67\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3682\" data-end=\"3799\">\u00cen conformitate cu ISO 11040-4 anexa G4, un raport de testare complet trebuie s\u0103 includ\u0103:<\/p><ul><li data-start=\"3802\" data-end=\"3826\">Valori de v\u00e2rf ale cuplului (Ncm)<\/li><li data-start=\"3829\" data-end=\"3849\">Viteza de rota\u021bie (rpm)<\/li><li data-start=\"3852\" data-end=\"3876\">Num\u0103rul de probe testate<\/li><li data-start=\"3879\" data-end=\"3896\">Rezultate pozitive\/neperformante<\/li><li data-start=\"3899\" data-end=\"3931\">Note privind abaterile sau anomaliile<\/li><\/ul><p class=\"\" data-start=\"3933\" data-end=\"4059\">Aceast\u0103 documenta\u021bie asigur\u0103 trasabilitatea \u0219i conformitatea, ambele esen\u021biale pentru auditurile de reglementare \u0219i certificarea lans\u0103rii produsului.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb68c8a e-con-full e-flex e-con e-child\" data-id=\"cb68c8a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c067893 elementor-widget elementor-widget-heading\" data-id=\"c067893\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Avantajele test\u0103rii automate a momentului de torsiune<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36ac35a elementor-widget elementor-widget-text-editor\" data-id=\"36ac35a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4066\" data-end=\"4277\">La Cell Instruments, ne specializ\u0103m \u00een sisteme de testare de precizie, inclusiv testere de cuplu adaptate pentru <strong data-start=\"4211\" data-end=\"4243\">Rezisten\u021ba la cuplu a gulerului LLA<\/strong> evalu\u0103ri. Automatizarea \u00eembun\u0103t\u0103\u021be\u0219te:<\/p><ul><li data-start=\"4280\" data-end=\"4309\"><strong data-start=\"4280\" data-end=\"4309\">Repetabilitatea m\u0103sur\u0103rii<\/strong><\/li><li data-start=\"4312\" data-end=\"4329\"><strong data-start=\"4312\" data-end=\"4329\">Precizia datelor<\/strong><\/li><li data-start=\"4332\" data-end=\"4358\"><strong data-start=\"4332\" data-end=\"4358\">Eficien\u021b\u0103 opera\u021bional\u0103<\/strong><\/li><li data-start=\"4361\" data-end=\"4385\"><strong data-start=\"4361\" data-end=\"4385\">Asigurarea conformit\u0103\u021bii<\/strong><\/li><\/ul><p class=\"\" data-start=\"4387\" data-end=\"4527\">Dispozitivele personalizate \u0219i integrarea software-ului permit laboratoarelor s\u0103 eficientizeze fluxurile de lucru pentru testarea seringilor, respect\u00e2nd \u00een acela\u0219i timp cu stricte\u021be liniile directoare ISO.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11ccf92 elementor-widget elementor-widget-text-editor\" data-id=\"11ccf92\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4984\" data-end=\"5514\">\u00cen\u021belegerea \u0219i punerea \u00een aplicare a <strong data-start=\"5036\" data-end=\"5068\">Rezisten\u021ba la cuplu a gulerului LLA<\/strong> test \u00een conformitate cu <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5092\" data-end=\"5107\">ISO 11040-4<\/strong><\/a> \u0219i <strong data-start=\"5112\" data-end=\"5124\">Anexa G4<\/strong> este vital pentru asigurarea calit\u0103\u021bii seringilor. Acest test protejeaz\u0103 \u00eempotriva defec\u021biunilor mecanice \u00een timpul utiliz\u0103rii clinice \u0219i ajut\u0103 produc\u0103torii s\u0103 men\u021bin\u0103 cele mai \u00eenalte standarde de siguran\u021b\u0103 a pacien\u021bilor. La <strong data-start=\"5308\" data-end=\"5328\">Instrumente celulare<\/strong>, oferim solu\u021bii de testare a cuplului de ultim\u0103 genera\u021bie care se aliniaz\u0103 standardelor globale \u0219i nevoilor industriei, oferind produc\u0103torilor de seringi date fiabile \u0219i \u00eencredere \u00een reglementare.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Rezisten\u021ba la torsiune a colierului LLA ISO 11040-4 Anexa G4 \u00cen produc\u021bia farmaceutic\u0103, asigurarea integrit\u0103\u021bii mecanice a seringilor preumplute este esen\u021bial\u0103 pentru siguran\u021ba \u0219i performan\u021ba produsului. Un factor cheie al acestei integrit\u0103\u021bi este rezisten\u021ba la torsiune a gulerului LLA, care m\u0103soar\u0103 rezisten\u021ba gulerului adaptorului Luer Lock (LLA) la torsiune. Aceast\u0103 proprietate asigur\u0103 c\u0103 gulerul [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2105","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/ro\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/comments?post=2105"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2105\/revisions"}],"predecessor-version":[{"id":2111,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/2105\/revisions\/2111"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/media?parent=2105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/categories?post=2105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/tags?post=2105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}