{"id":1893,"date":"2025-01-24T05:40:31","date_gmt":"2025-01-24T05:40:31","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=1893"},"modified":"2025-04-02T06:30:55","modified_gmt":"2025-04-02T06:30:55","slug":"syringe-glide-force-testing-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/ro\/syringe-glide-force-testing-iso-11040-4\/","title":{"rendered":"Testarea for\u021bei de alunecare a seringii | ISO 11040-4 Anexa E"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"1893\" class=\"elementor elementor-1893\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c8f6b32 e-flex e-con-boxed e-con e-parent\" data-id=\"c8f6b32\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3871c01 elementor-widget elementor-widget-heading\" data-id=\"3871c01\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Testarea for\u021bei de alunecare a seringii<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28eeae4 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"28eeae4\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c6f7aa elementor-widget elementor-widget-heading\" data-id=\"9c6f7aa\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Anexa E<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-60074b4 e-flex e-con-boxed e-con e-parent\" data-id=\"60074b4\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-9e604be e-con-full e-flex e-con e-child\" data-id=\"9e604be\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-815caf1 elementor-widget elementor-widget-text-editor\" data-id=\"815caf1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>\u00cen industria medical\u0103 \u0219i farmaceutic\u0103, asigurarea performan\u021bei \u0219i calit\u0103\u021bii seringilor este esen\u021bial\u0103. O metod\u0103 critic\u0103 pentru evaluarea func\u021bionalit\u0103\u021bii seringilor este prin <strong>Testarea for\u021bei de alunecare a seringii ISO 11040-4<\/strong>. Acest standard ajut\u0103 produc\u0103torii s\u0103 se asigure c\u0103 seringile, lubrifiate sau nelubrifiate, func\u021bioneaz\u0103 \u00een mod constant \u0219i fiabil atunci c\u00e2nd sunt utilizate pentru administrarea medicamentelor.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf043c8 elementor-widget elementor-widget-heading\" data-id=\"bf043c8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ce este testarea for\u021bei de alunecare a seringii ISO 11040-4?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7514f4b elementor-widget elementor-widget-text-editor\" data-id=\"7514f4b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>ISO 11040-4 prezint\u0103 procedura de m\u0103surare a <strong>for\u021b\u0103 de alunecare<\/strong> a unei seringi, care este for\u021ba necesar\u0103 pentru a deplasa pistonul \u00een interiorul cilindrului. Acest test este vital pentru evaluarea calit\u0103\u021bii \u0219i consisten\u021bei seringilor, \u00een special atunci c\u00e2nd acestea sunt utilizate \u00een aplica\u021bii medicale.<\/p><p>Scopul acestei test\u0103ri este dublu:<\/p><ol><li><strong>Evaluarea lubrifierii<\/strong>: Ajut\u0103 la determinarea eficacit\u0103\u021bii lubrifierii din interiorul cilindrului seringii, realizat\u0103 de obicei cu ulei de silicon sau alte materiale.<\/li><li><strong>Seringi nelubrifiate<\/strong>: De asemenea, testul evalueaz\u0103 seringile nelubrifiate, inclusiv cele umplute cu ap\u0103 pentru injectare, simul\u00e2nd condi\u021biile reale de utilizare.<\/li><\/ol><p>Aceast\u0103 procedur\u0103 asigur\u0103 c\u0103 seringile \u00eendeplinesc anumite standarde privind for\u021ba de alunecare, reduc\u00e2nd frecarea \u00een timpul injec\u021biei \u0219i asigur\u00e2nd siguran\u021ba \u0219i confortul pacientului.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91331e3 elementor-widget elementor-widget-heading\" data-id=\"91331e3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Importan\u021ba for\u021bei de alunecare \u00een seringi<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61602c4 elementor-widget elementor-widget-text-editor\" data-id=\"61602c4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Testul for\u021bei de alunecare nu se refer\u0103 doar la asigurarea unei mi\u0219c\u0103ri u\u0219oare a pistonului. For\u021ba de alunecare indic\u0103 <strong>calitatea performan\u021bei<\/strong> a seringii:<\/p><ul><li><strong>For\u021b\u0103 mare de alunecare<\/strong>: Frecarea excesiv\u0103 poate duce la disconfort \u00een timpul inject\u0103rii \u0219i ar putea chiar cauza dificult\u0103\u021bi pentru personalul medical \u00een administrarea medicamentului.<\/li><li><strong>For\u021b\u0103 de alunecare redus\u0103<\/strong>: Frecarea insuficient\u0103 poate duce la scurgeri, f\u0103c\u00e2nd seringa nesigur\u0103 \u0219i poten\u021bial nesigur\u0103 pentru utilizarea medical\u0103.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a343f22 elementor-widget elementor-widget-heading\" data-id=\"a343f22\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Materiale necesare pentru testarea for\u021bei de alunecare a seringii ISO 11040-4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78bacbc elementor-widget elementor-widget-text-editor\" data-id=\"78bacbc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Pentru o testare eficient\u0103, sunt necesare anumite materiale \u0219i echipamente, inclusiv:<\/p><ul><li><strong>Seringi sterilizate<\/strong>: Seringile testate trebuie s\u0103 fie preg\u0103tite pentru umplere, cu sterilizare corespunz\u0103toare pentru a evita contaminarea.<\/li><li><strong>Dopuri de piston<\/strong>: Acestea trebuie s\u0103 fie compatibile cu \u021beava seringii \u0219i cu utilizarea prev\u0103zut\u0103.<\/li><li><strong>Tije de piston<\/strong>: Acestea sunt esen\u021biale pentru aplicarea for\u021bei necesare \u00een timpul test\u0103rii.<\/li><\/ul><p>Aceste materiale trebuie s\u0103 fie convenite \u00eentre produc\u0103tor \u0219i client, acord\u00e2ndu-se o aten\u021bie deosebit\u0103 tipului de dop al pistonului \u0219i lubrifierii acestuia.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba26707 elementor-widget elementor-widget-heading\" data-id=\"ba26707\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aparatur\u0103 utilizat\u0103 \u00een testarea ISO 11040-4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e84859 elementor-widget elementor-widget-image\" data-id=\"3e84859\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/ro\/medical-syringe-tester\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/elementor\/thumbs\/syringe-glide-force-testing-iso-11040-4-1-scaled-r0grycyljh00j2lr5tp8u0op55p1txljfuzjxlcwi0.webp\" title=\"testarea for\u021bei de alunecare a seringii iso 11040 4\" alt=\"testarea for\u021bei de alunecare a seringii iso 11040 4\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e366efc elementor-widget elementor-widget-text-editor\" data-id=\"e366efc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Testarea ISO 11040-4 necesit\u0103 echipamente specializate:<\/p><ul><li><strong>Ma\u0219in\u0103 universal\u0103 de testare la trac\u021biune \u0219i compresiune<\/strong>: Acest aparat este utilizat pentru a aplica for\u021ba la o anumit\u0103 vitez\u0103, de obicei 100 mm\/min, pentru a m\u0103sura cu exactitate for\u021ba de alunecare. Gama de for\u021be ar trebui s\u0103 mearg\u0103 p\u00e2n\u0103 la cel pu\u021bin 50 N, \u00een func\u021bie de specifica\u021biile seringii.<\/li><li><strong>Suport sering\u0103 \u0219i pl\u0103ci adaptoare<\/strong>: Acestea sunt utilizate pentru a men\u021bine seringa \u00een pozi\u021bie \u00een timpul testului, asigur\u00e2ndu-se c\u0103 for\u021ba este aplicat\u0103 corect.<\/li><li><strong>Tub de aerisire sau unealt\u0103 de oprire a vidului<\/strong>: Acest instrument este utilizat pentru instalarea dopului pistonului \u00een cilindrul seringii, men\u021bin\u00e2nd sterilitatea \u0219i pozi\u021bionarea corect\u0103.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e772501 elementor-widget elementor-widget-heading\" data-id=\"e772501\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedura de efectuare a testului\n<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1923553 elementor-widget elementor-widget-text-editor\" data-id=\"1923553\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Testul ISO 11040-4 privind for\u021ba de alunecare urmeaz\u0103 o procedur\u0103 sistematic\u0103:<\/p><ol><li><strong>Introduce\u021bi opritorul pistonului<\/strong>: A\u0219eza\u021bi dopul pistonului \u00een corpul seringii folosind fie un tub de aerisire, fie o metod\u0103 de astupare prin vid.<\/li><li><strong>Setarea tijei plonjorului<\/strong>: Ata\u0219a\u021bi tija pistonului la dop, asigur\u00e2ndu-v\u0103 c\u0103 se aliniaz\u0103 cu dispozitivul de testare.<\/li><li><strong>Introduce\u021bi seringa \u00een dispozitivul de testare<\/strong>: Pozi\u021biona\u021bi seringa \u00een placa adaptoare a ma\u0219inii de testare la trac\u021biune.<\/li><li><strong>Aplica\u021bi For\u021ba<\/strong>: \u00cencepe\u021bi testul de compresie, aplic\u00e2nd for\u021ba la viteza convenit\u0103, de obicei 100 mm\/min.<\/li><li><strong>M\u0103surarea for\u021bei maxime<\/strong>: \u00cenregistra\u021bi for\u021ba maxim\u0103 \u00eenregistrat\u0103 \u00een regiunea de testare a for\u021bei de alunecare, care este sec\u021biunea dintre for\u021ba ini\u021bial\u0103 \u0219i cre\u0219terea brusc\u0103 de la sf\u00e2r\u0219itul cursei pistonului.<\/li><li><strong>Se repet\u0103 pentru mai multe e\u0219antioane<\/strong>: Efectua\u021bi testul pentru mai multe seringi pentru a asigura coeren\u021ba.<\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b869036 elementor-widget elementor-widget-heading\" data-id=\"b869036\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Calcularea for\u021bei pistonului seringii<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c126a7 elementor-widget elementor-widget-text-editor\" data-id=\"1c126a7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Rezultatele testului sunt documentate, inclusiv:<\/p><ul><li><strong>For\u021ba maxim\u0103 de alunecare<\/strong>: Cea mai mare for\u021b\u0103 observat\u0103 \u00een regiunea de testare a for\u021bei de alunecare.<\/li><li><strong>For\u021ba medie de alunecare<\/strong>: For\u021ba medie calculat\u0103, care ofer\u0103 o imagine de ansamblu a performan\u021bei seringii.<\/li><li><strong>Documenta\u021bia de testare<\/strong>: Orice abateri sau observa\u021bii trebuie notate pentru trasabilitate \u0219i conformitate.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c72def5 elementor-widget elementor-widget-heading\" data-id=\"c72def5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Considera\u021bii cheie pentru testarea precis\u0103 a for\u021bei de alunecare<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9d3425 elementor-widget elementor-widget-text-editor\" data-id=\"f9d3425\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li><strong>Viteza de testare<\/strong>: De obicei, se utilizeaz\u0103 o vitez\u0103 de 100 mm\/min, dar aceasta poate varia \u00een func\u021bie de cerin\u021bele produc\u0103torului.<\/li><li><strong>Rata de e\u0219antionare<\/strong>: O rat\u0103 de e\u0219antionare mai mare (de exemplu, 500 Hz) este recomandat\u0103 pentru m\u0103sur\u0103tori de v\u00e2rf mai precise.<\/li><li><strong>Mediu de testare<\/strong>: Mediul de testare ar trebui s\u0103 fie controlat pentru a evita factorii externi care influen\u021beaz\u0103 rezultatele, cum ar fi temperatura sau umiditatea.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Testarea for\u021bei de alunecare a seringii ISO 11040-4 Anexa E \u00cen industria medical\u0103 \u0219i farmaceutic\u0103, asigurarea performan\u021bei \u0219i calit\u0103\u021bii seringilor este esen\u021bial\u0103. O metod\u0103 esen\u021bial\u0103 de evaluare a func\u021bionalit\u0103\u021bii seringii este testarea for\u021bei de alunecare a seringii ISO 11040-4. Acest standard ajut\u0103 produc\u0103torii s\u0103 se asigure c\u0103 seringile, lubrifiate sau nelubrifiate, func\u021bioneaz\u0103 \u00een mod constant \u0219i fiabil atunci c\u00e2nd [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-1893","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/ro\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Syringe Glide Force Testing ISO 11040-4 Annex E In the medical and pharmaceutical industries, ensuring the performance and quality of syringes is paramount. One critical method for assessing syringe functionality is through the ISO 11040-4 syringe glide force testing. This standard helps manufacturers ensure that syringes, whether lubricated or non-lubricated, perform consistently and reliably when&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/1893","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/comments?post=1893"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/1893\/revisions"}],"predecessor-version":[{"id":2012,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/posts\/1893\/revisions\/2012"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/media?parent=1893"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/categories?post=1893"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/ro\/wp-json\/wp\/v2\/tags?post=1893"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}