{"id":2429,"date":"2025-11-06T07:49:46","date_gmt":"2025-11-06T07:49:46","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2429"},"modified":"2025-11-06T07:55:39","modified_gmt":"2025-11-06T07:55:39","slug":"iso-9626","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/pt\/iso-9626\/","title":{"rendered":"ISO 9626"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2429\" class=\"elementor elementor-2429\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5aa439d7 e-flex e-con-boxed e-con e-parent\" data-id=\"5aa439d7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-442ef7 elementor-widget elementor-widget-text-editor\" data-id=\"442ef7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><\/h2>\n<!-- \/wp:heading -->\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8d2ddaa e-flex e-con-boxed e-con e-parent\" data-id=\"8d2ddaa\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1da949 elementor-widget elementor-widget-heading\" data-id=\"a1da949\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 9626 <br><small><small>Teste de tubos de agulha de a\u00e7o inoxid\u00e1vel<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28c31c0 e-con-full e-flex e-con e-child\" data-id=\"28c31c0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b07c887 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"b07c887\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"463\" data-end=\"992\"><strong data-start=\"463\" data-end=\"475\">ISO 9626<\/strong> especifica os requisitos e <strong data-start=\"507\" data-end=\"557\">m\u00e9todos de ensaio para tubos de agulhas de a\u00e7o inoxid\u00e1vel<\/strong> utilizados no fabrico de dispositivos m\u00e9dicos, tais como agulhas hipod\u00e9rmicas e c\u00e2nulas. Esta norma internacional garante que os tubos utilizados em aplica\u00e7\u00f5es m\u00e9dicas cumprem requisitos consistentes de desempenho e seguran\u00e7a. Dois testes-chave da ISO 9626 s\u00e3o <strong data-start=\"814\" data-end=\"842\">ensaio de rigidez da tubagem<\/strong> e o <strong data-start=\"851\" data-end=\"892\">resist\u00eancia da tubagem ao ensaio de rutura<\/strong>que s\u00e3o essenciais para avaliar a integridade mec\u00e2nica e a durabilidade dos tubos de a\u00e7o inoxid\u00e1vel.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34234b5 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"34234b5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/11\/ISO-9626-\u2013-Stainless-Steel-Needle-Tubing-Stiffness-and-Break-Strength-Testing.webp\" class=\"attachment-full size-full wp-image-2435\" alt=\"ISO 9626 - Ensaios de rigidez e de resist\u00eancia \u00e0 rutura de tubos de agulhas de a\u00e7o inoxid\u00e1vel\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/11\/ISO-9626-\u2013-Stainless-Steel-Needle-Tubing-Stiffness-and-Break-Strength-Testing.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/11\/ISO-9626-\u2013-Stainless-Steel-Needle-Tubing-Stiffness-and-Break-Strength-Testing-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/11\/ISO-9626-\u2013-Stainless-Steel-Needle-Tubing-Stiffness-and-Break-Strength-Testing-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/11\/ISO-9626-\u2013-Stainless-Steel-Needle-Tubing-Stiffness-and-Break-Strength-Testing-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0df13d1 elementor-widget elementor-widget-heading\" data-id=\"0df13d1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">O que \u00e9 a norma ISO 9626?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-185e4a4 elementor-widget elementor-widget-text-editor\" data-id=\"185e4a4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1422\">A norma ISO 9626, t\u00edtulo completo <em data-start=\"1346\" data-end=\"1450\">\"Tubagem de agulhas de a\u00e7o inoxid\u00e1vel para o fabrico de dispositivos m\u00e9dicos - Requisitos e m\u00e9todos de ensaio\"<\/em>, aplica-se a <strong data-start=\"1463\" data-end=\"1502\">tubo r\u00edgido de agulha em a\u00e7o inoxid\u00e1vel<\/strong> apto para o fabrico de agulhas hipod\u00e9rmicas e outros componentes de dispositivos m\u00e9dicos.<\/p>\n<p data-start=\"1283\" data-end=\"1620\">A norma ISO 9626 desempenha um papel crucial na garantia de que os tubos de a\u00e7o inoxid\u00e1vel utilizados para agulhas m\u00e9dicas t\u00eam suficiente <strong data-start=\"1393\" data-end=\"1416\">resist\u00eancia mec\u00e2nica<\/strong>, <strong data-start=\"1418\" data-end=\"1433\">flexibilidade<\/strong>e <strong data-start=\"1439\" data-end=\"1464\">resist\u00eancia \u00e0 fadiga<\/strong>. A tubagem que n\u00e3o cumpra estes requisitos pode resultar na flex\u00e3o ou quebra da agulha durante a utiliza\u00e7\u00e3o, colocando em risco os doentes e os profissionais de sa\u00fade.<\/p>\n<p data-start=\"1622\" data-end=\"1645\">A norma define:<\/p>\n<ul>\n<li data-start=\"1648\" data-end=\"1705\"><strong data-start=\"1648\" data-end=\"1675\">Especifica\u00e7\u00f5es do material<\/strong> para tubos de a\u00e7o inoxid\u00e1vel.<\/li>\n<li data-start=\"1708\" data-end=\"1775\"><strong data-start=\"1708\" data-end=\"1734\">Toler\u00e2ncias dimensionais<\/strong> incluindo a espessura e o di\u00e2metro da parede.<\/li>\n<li data-start=\"1778\" data-end=\"1853\"><strong data-start=\"1778\" data-end=\"1807\">Ensaios de propriedades mec\u00e2nicas<\/strong>como a rigidez e a resist\u00eancia \u00e0 rutura.<\/li>\n<\/ul>\n<p data-start=\"1855\" data-end=\"1991\">A ades\u00e3o \u00e0 norma ISO 9626 ajuda os fabricantes a manter uma qualidade consistente dos produtos e a cumprir os regulamentos internacionais relativos a dispositivos m\u00e9dicos.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-304c484 elementor-widget elementor-widget-heading\" data-id=\"304c484\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ao avaliar a tubagem de dispositivos m\u00e9dicos, dois aspectos do desempenho mec\u00e2nico s\u00e3o especialmente significativos:<\/p>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a08344a elementor-widget elementor-widget-heading\" data-id=\"a08344a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ensaio de rigidez da tubagem<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8605095 elementor-widget elementor-widget-text-editor\" data-id=\"8605095\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2030\" data-end=\"2392\">O <strong data-start=\"2034\" data-end=\"2062\">ensaio de rigidez da tubagem<\/strong> avalia a resist\u00eancia \u00e0 deforma\u00e7\u00e3o da tubagem de agulhas de a\u00e7o inoxid\u00e1vel quando \u00e9 aplicada uma for\u00e7a. De acordo com o Anexo B da norma ISO 9626, o teste envolve o apoio de um comprimento espec\u00edfico de tubo em ambas as extremidades e a aplica\u00e7\u00e3o de uma for\u00e7a conhecida <strong data-start=\"2287\" data-end=\"2319\">for\u00e7a descendente no seu centro<\/strong>. O montante de <strong data-start=\"2335\" data-end=\"2349\">deflex\u00e3o<\/strong> \u00e9 ent\u00e3o medido para determinar a rigidez.<\/p>\n<p data-start=\"2394\" data-end=\"2540\">Este teste permite saber at\u00e9 que ponto a tubagem se flexiona sob carga - um fator-chave para garantir que a <strong data-start=\"2498\" data-end=\"2537\">estabilidade da agulha durante a inser\u00e7\u00e3o<\/strong>.<\/p>\n<h4 data-start=\"2542\" data-end=\"2567\">Vis\u00e3o geral do procedimento<\/h4>\n<ol data-start=\"2568\" data-end=\"2856\">\n<li data-start=\"2568\" data-end=\"2669\">\n<p data-start=\"2571\" data-end=\"2669\">A tubagem \u00e9 colocada num <strong data-start=\"2597\" data-end=\"2628\">aparelho de ensaio da rigidez<\/strong> com um intervalo definido em fun\u00e7\u00e3o do seu tamanho.<\/p>\n<\/li>\n<li data-start=\"2670\" data-end=\"2768\">\n<p data-start=\"2673\" data-end=\"2768\">A <strong data-start=\"2675\" data-end=\"2694\">\u00eambolo de carga<\/strong> aplica uma for\u00e7a para baixo a uma velocidade entre <strong data-start=\"2739\" data-end=\"2765\">1 mm\/min e 10 mm\/min<\/strong>.<\/p>\n<\/li>\n<li data-start=\"2769\" data-end=\"2856\">\n<p data-start=\"2772\" data-end=\"2856\">O <strong data-start=\"2776\" data-end=\"2790\">deflex\u00e3o<\/strong> no ponto de carregamento \u00e9 registada com a precis\u00e3o de <strong data-start=\"2842\" data-end=\"2853\">0,01 mm<\/strong>.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"2858\" data-end=\"3058\">Uma maior rigidez indica tubos mais fortes que resistem \u00e0 flex\u00e3o, enquanto uma menor rigidez pode sugerir uma maior flexibilidade. Ambas as propriedades s\u00e3o importantes, dependendo da aplica\u00e7\u00e3o m\u00e9dica pretendida.<\/p>\n<p data-start=\"3060\" data-end=\"3349\"><strong data-start=\"3060\" data-end=\"3098\">Testador de rigidez da Cell Instruments<\/strong> oferece um sistema de carga controlado com precis\u00e3o e uma medi\u00e7\u00e3o digital do deslocamento, totalmente em conformidade com os requisitos da norma ISO 9626. Permite aos laborat\u00f3rios efetuar <strong data-start=\"3260\" data-end=\"3309\">ensaios de rigidez de tubos de agulhas de a\u00e7o inoxid\u00e1vel<\/strong> com elevada precis\u00e3o e repetibilidade.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80ffe02 elementor-widget elementor-widget-heading\" data-id=\"80ffe02\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Resist\u00eancia dos tubos \u00e0 rutura<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24288c0 elementor-widget elementor-widget-text-editor\" data-id=\"24288c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3396\" data-end=\"3665\">O <strong data-start=\"3400\" data-end=\"3441\">resist\u00eancia da tubagem ao ensaio de rutura<\/strong> (ISO 9626 Anexo C) avalia a capacidade do tubo para resistir a flex\u00f5es repetidas sem fissuras ou roturas. Isto simula as condi\u00e7\u00f5es do mundo real em que uma agulha pode ser sujeita a tens\u00f5es c\u00edclicas durante o manuseamento ou a utiliza\u00e7\u00e3o.<\/p>\n<h4 data-start=\"3667\" data-end=\"3688\">Princ\u00edpio de teste<\/h4>\n<p data-start=\"3689\" data-end=\"4019\">Uma extremidade da tubagem \u00e9 fixada rigidamente e uma <strong data-start=\"3735\" data-end=\"3761\">for\u00e7a de flex\u00e3o repetida<\/strong> \u00e9 aplicado a uma dist\u00e2ncia espec\u00edfica. A tubagem \u00e9 dobrada alternadamente em direc\u00e7\u00f5es opostas atrav\u00e9s de um \u00e2ngulo definido - normalmente <strong data-start=\"3887\" data-end=\"3920\">25\u00b0 para tubos de parede regular<\/strong>, <strong data-start=\"3922\" data-end=\"3945\">20\u00b0 para paredes finas<\/strong>e <strong data-start=\"3951\" data-end=\"3987\">15\u00b0 para tubos de paredes ultra-finas<\/strong> - para <strong data-start=\"3994\" data-end=\"4016\">20 ciclos completos<\/strong>.<\/p>\n<p data-start=\"4021\" data-end=\"4096\">Ap\u00f3s o teste, a tubagem \u00e9 examinada visualmente para detetar quaisquer sinais de rutura.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-54ef89d e-flex e-con-boxed e-con e-child\" data-id=\"54ef89d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d72668b elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"d72668b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong data-start=\"4098\" data-end=\"4143\">Instrumentos celulares\". <a href=\"https:\/\/www.pharmacopoeiatest.com\/pt\/medical-needle-break-resistance-tester\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">Testador de resist\u00eancia \u00e0 rutura<\/a><\/strong> possui um controlo de movimento c\u00edclico program\u00e1vel e um sistema de deslocamento angular preciso, permitindo uma avalia\u00e7\u00e3o exacta da <strong data-start=\"4276\" data-end=\"4298\">resist\u00eancia \u00e0 fadiga<\/strong> e <strong data-start=\"4303\" data-end=\"4317\">durabilidade<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d56cba elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"5d56cba\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/pt\/medical-needle-break-resistance-tester\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp\" class=\"attachment-large size-large wp-image-1924\" alt=\"Testador de resist\u00eancia \u00e0 quebra de agulhas m\u00e9dicas\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp 1000w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-768x768.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7bc2f44 elementor-widget elementor-widget-heading\" data-id=\"7bc2f44\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Perguntas frequentes<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7e535a elementor-widget elementor-widget-toggle\" data-id=\"d7e535a\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2261\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2261\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q1: O que \u00e9 a norma ISO 9626?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2261\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2261\"><p data-start=\"5213\" data-end=\"5511\"><strong data-start=\"5241\" data-end=\"5247\">A:<\/strong> <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener\">ISO 9626<\/a> \u00e9 uma norma internacional que especifica os requisitos e m\u00e9todos de ensaio para <strong data-start=\"5335\" data-end=\"5368\">tubo de agulha de a\u00e7o inoxid\u00e1vel<\/strong> utilizados no fabrico de dispositivos m\u00e9dicos. Define par\u00e2metros para dimens\u00f5es, rigidez, resist\u00eancia \u00e0 rutura e desempenho mec\u00e2nico global.<\/p>\n<p data-start=\"5513\" data-end=\"5787\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2262\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2262\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q2: Porque \u00e9 que a rigidez do ensaio de tubagem \u00e9 importante?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2262\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2262\"><p data-start=\"5513\" data-end=\"5787\"><strong data-start=\"5570\" data-end=\"5576\">A:<\/strong> O <strong data-start=\"5581\" data-end=\"5609\">ensaio de rigidez da tubagem<\/strong> assegura que a tubagem mant\u00e9m uma rigidez suficiente e n\u00e3o se dobra excessivamente sob carga. \u00c9 essencial para a estabilidade e precis\u00e3o das agulhas m\u00e9dicas durante a inser\u00e7\u00e3o.<\/p>\n<p data-start=\"5789\" data-end=\"6071\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2263\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2263\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q3: O que \u00e9 que o teste de resist\u00eancia \u00e0 rutura da tubagem avalia?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2263\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2263\"><p data-start=\"5789\" data-end=\"6071\"><strong data-start=\"5861\" data-end=\"5867\">A:<\/strong> Este teste mede a capacidade da tubagem para suportar <strong data-start=\"5921\" data-end=\"5948\">ciclos de flex\u00e3o repetidos<\/strong> sem fissuras. Ajuda a confirmar a durabilidade e a seguran\u00e7a dos tubos m\u00e9dicos de a\u00e7o inoxid\u00e1vel em aplica\u00e7\u00f5es cl\u00ednicas.<\/p>\n<p data-start=\"6073\" data-end=\"6350\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2264\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2264\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q4: Que equipamento pode efetuar ensaios ISO 9626?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2264\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2264\"><p data-start=\"6073\" data-end=\"6350\"><strong data-start=\"6129\" data-end=\"6135\">A:<\/strong> <strong data-start=\"6136\" data-end=\"6202\">Aparelho de teste de rigidez e de resist\u00eancia \u00e0 rutura da Cell Instruments<\/strong> foram especificamente concebidos para realizar testes em conformidade com a norma ISO 9626, oferecendo um controlo preciso da for\u00e7a, medi\u00e7\u00e3o automatizada e repetibilidade fi\u00e1vel.<\/p>\n<p data-start=\"6352\" data-end=\"6632\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2265\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2265\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q5: Quem deve efetuar os ensaios ISO 9626?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2265\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2265\"><p data-start=\"6352\" data-end=\"6632\"><strong data-start=\"6397\" data-end=\"6403\">A:<\/strong> Engenheiros de controlo de qualidade, t\u00e9cnicos de laborat\u00f3rio e fabricantes de dispositivos m\u00e9dicos que produzem ou validam <strong data-start=\"6512\" data-end=\"6545\">tubo de agulha de a\u00e7o inoxid\u00e1vel<\/strong> deve efetuar estes ensaios para garantir a conformidade com as normas de seguran\u00e7a internacionais.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Teste de tubagem de agulha em a\u00e7o inoxid\u00e1vel ISO 9626 A ISO 9626 especifica os requisitos e m\u00e9todos de teste para tubagem de agulha em a\u00e7o inoxid\u00e1vel utilizada no fabrico de dispositivos m\u00e9dicos, tais como agulhas hipod\u00e9rmicas e c\u00e2nulas. Esta norma internacional garante que os tubos utilizados em aplica\u00e7\u00f5es m\u00e9dicas cumprem requisitos consistentes de desempenho e seguran\u00e7a. Dois ensaios-chave no \u00e2mbito da norma ISO [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2429","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/pt\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 9626 Stainless Steel Needle Tubing Test ISO 9626 specifies the requirements and test methods for stainless steel needle tubing used in the manufacture of medical devices such as hypodermic needles and cannulas. This international standard ensures that the tubing used in medical applications meets consistent performance and safety requirements. Two key tests under ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts\/2429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/comments?post=2429"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts\/2429\/revisions"}],"predecessor-version":[{"id":2445,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts\/2429\/revisions\/2445"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/media?parent=2429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/categories?post=2429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/tags?post=2429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}