{"id":2225,"date":"2025-07-17T03:26:50","date_gmt":"2025-07-17T03:26:50","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2225"},"modified":"2025-07-17T03:32:17","modified_gmt":"2025-07-17T03:32:17","slug":"break-loose-and-glide-force-testing","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/pt\/break-loose-and-glide-force-testing\/","title":{"rendered":"Ensaio de for\u00e7a de rutura e deslizamento para papel: ISO 7886 e avalia\u00e7\u00e3o da seringa"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2225\" class=\"elementor elementor-2225\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9145dad e-flex e-con-boxed e-con e-parent\" data-id=\"9145dad\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a89c638 elementor-widget elementor-widget-heading\" data-id=\"a89c638\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Teste de for\u00e7a de rutura e deslizamento: Um indicador-chave do desempenho da seringa<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b6a1371 e-flex e-con-boxed e-con e-parent\" data-id=\"b6a1371\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-693eb6e elementor-widget elementor-widget-text-editor\" data-id=\"693eb6e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"538\" data-end=\"945\">Nos sectores farmac\u00eautico e dos dispositivos m\u00e9dicos, <strong data-start=\"591\" data-end=\"630\">ensaios de rutura e de for\u00e7a de deslizamento<\/strong> \u00e9 um procedimento cr\u00edtico utilizado para avaliar a capacidade de utiliza\u00e7\u00e3o e a qualidade das seringas. Estes testes determinam a for\u00e7a necess\u00e1ria para iniciar (soltar) e continuar (deslizar) o movimento do \u00eambolo dentro do corpo da seringa. Os resultados t\u00eam um impacto direto na conformidade do produto, no conforto da inje\u00e7\u00e3o e na seguran\u00e7a do doente.<\/p><p data-start=\"947\" data-end=\"1391\">Este m\u00e9todo de ensaio \u00e9 especialmente importante para os fabricantes que desenvolvem <strong data-start=\"1016\" data-end=\"1091\">seringas pr\u00e9-cheias, subconjuntos est\u00e9reis e componentes de auto-injectores<\/strong>. Um \u00eambolo demasiado apertado ou solto pode levar a erros de dosagem, desprendimento do \u00eambolo ou fluxo inconsistente de medica\u00e7\u00e3o - todos estes factores representam riscos de seguran\u00e7a. Por este motivo, o processo de teste est\u00e1 claramente descrito em v\u00e1rias normas internacionais, incluindo <strong data-start=\"1341\" data-end=\"1355\">ISO 7886-1<\/strong>, <strong data-start=\"1357\" data-end=\"1372\">ISO 11040-4<\/strong>e <strong data-start=\"1378\" data-end=\"1390\">ISO 8537<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ee73ce6 e-flex e-con-boxed e-con e-parent\" data-id=\"ee73ce6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7316cbe elementor-widget elementor-widget-heading\" data-id=\"7316cbe\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Teste da for\u00e7a de deslizamento da seringa e normas internacionais de conformidade<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4fe64ba e-flex e-con-boxed e-con e-parent\" data-id=\"4fe64ba\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-697f2ea elementor-widget elementor-widget-text-editor\" data-id=\"697f2ea\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1470\" data-end=\"1745\">Os organismos reguladores estabeleceram requisitos rigorosos para garantir que o desempenho da seringa \u00e9 fi\u00e1vel e reprodut\u00edvel. <strong data-start=\"1585\" data-end=\"1616\">Teste da for\u00e7a de deslizamento da seringa<\/strong> avalia o comportamento do atrito em condi\u00e7\u00f5es espec\u00edficas, com o objetivo de detetar varia\u00e7\u00f5es na lubrifica\u00e7\u00e3o ou nas propriedades do material.<\/p><p data-start=\"1747\" data-end=\"2087\"><strong data-start=\"1747\" data-end=\"1761\">ISO 7886-1<\/strong><br data-start=\"1761\" data-end=\"1764\" \/>Esta norma aplica-se a <strong data-start=\"1789\" data-end=\"1820\">seringas esterilizadas de utiliza\u00e7\u00e3o \u00fanica<\/strong>. Define m\u00e9todos de medi\u00e7\u00e3o de for\u00e7a para os valores de rutura e de deslizamento, que devem permanecer dentro de intervalos pr\u00e9-estabelecidos para garantir o bom funcionamento. A velocidade de ensaio normalmente utilizada \u00e9 <strong data-start=\"2010\" data-end=\"2024\">100 mm\/min<\/strong>e recomenda-se a aquisi\u00e7\u00e3o de dados a alta frequ\u00eancia (\u2265500 Hz).<\/p><p data-start=\"2089\" data-end=\"2451\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/pt\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"2089\" data-end=\"2104\">ISO 11040-4<\/strong><\/a><br data-start=\"2104\" data-end=\"2107\" \/>Focado em <strong data-start=\"2118\" data-end=\"2158\">recipientes de vidro para seringas pr\u00e9-cheias<\/strong>Esta norma inclui <strong data-start=\"2183\" data-end=\"2194\">Anexo E<\/strong>que especifica o m\u00e9todo de ensaio de for\u00e7a de deslizamento para subconjuntos esterilizados. Define os requisitos para o <strong data-start=\"2300\" data-end=\"2366\">rolha de \u00eambolo, interior do tambor e lubrifica\u00e7\u00e3o com \u00f3leo de silicone<\/strong>. Um atrito consistentemente baixo \u00e9 essencial para cumprir os crit\u00e9rios definidos nesta norma.<\/p><p data-start=\"2453\" data-end=\"2717\"><strong data-start=\"2453\" data-end=\"2465\">ISO 8537<\/strong><br data-start=\"2465\" data-end=\"2468\" \/>Concebido para <strong data-start=\"2481\" data-end=\"2501\">seringas de insulina<\/strong>Esta norma enfatiza a administra\u00e7\u00e3o precisa da dose atrav\u00e9s do controlo do movimento do \u00eambolo. A resist\u00eancia ao deslizamento \u00e9 especialmente cr\u00edtica nos dispositivos de administra\u00e7\u00e3o de insulina, onde uma taxa de inje\u00e7\u00e3o constante garante uma gest\u00e3o segura da glicose.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f96e75b e-flex e-con-boxed e-con e-parent\" data-id=\"f96e75b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab96e67 elementor-widget elementor-widget-heading\" data-id=\"ab96e67\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedimentos e par\u00e2metros de ensaio<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e898377 e-flex e-con-boxed e-con e-parent\" data-id=\"e898377\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6c4a14 elementor-widget elementor-widget-text-editor\" data-id=\"e6c4a14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2760\" data-end=\"2842\">O procedimento para os ensaios de rutura e de for\u00e7a de deslizamento segue um formato estruturado:<\/p><ol data-start=\"2844\" data-end=\"3739\"><li data-start=\"2844\" data-end=\"2990\"><p data-start=\"2847\" data-end=\"2990\"><strong data-start=\"2847\" data-end=\"2862\">Prepara\u00e7\u00e3o<\/strong><br data-start=\"2862\" data-end=\"2865\" \/>Utiliza\u00e7\u00e3o <strong data-start=\"2872\" data-end=\"2901\">seringas vazias esterilizadas<\/strong> pronto a encher. Instalar uma rolha de \u00eambolo compat\u00edvel com n\u00edveis de lubrifica\u00e7\u00e3o definidos.<\/p><\/li><li data-start=\"2992\" data-end=\"3220\"><p data-start=\"2995\" data-end=\"3220\"><strong data-start=\"2995\" data-end=\"3004\">Configura\u00e7\u00e3o<\/strong><br data-start=\"3004\" data-end=\"3007\" \/>Colocar a seringa numa m\u00e1quina de ensaio universal ou num equipamento dedicado, como o <strong data-start=\"3094\" data-end=\"3155\">Cell Instruments SSR-01 Testador de resist\u00eancia de deslizamento de seringa<\/strong>. Fixe-o com o alinhamento correto da fixa\u00e7\u00e3o para garantir o movimento axial.<\/p><\/li><li data-start=\"3222\" data-end=\"3419\"><p data-start=\"3225\" data-end=\"3419\"><strong data-start=\"3225\" data-end=\"3238\">Execu\u00e7\u00e3o<\/strong><br data-start=\"3238\" data-end=\"3241\" \/>Iniciar o movimento do \u00eambolo a 100 mm\/min. O equipamento de ensaio regista o <strong data-start=\"3319\" data-end=\"3355\">for\u00e7a de rutura (pico inicial)<\/strong> e o <strong data-start=\"3364\" data-end=\"3418\">for\u00e7a de deslizamento (for\u00e7a m\u00e9dia durante o movimento cont\u00ednuo)<\/strong>.<\/p><\/li><li data-start=\"3421\" data-end=\"3597\"><p data-start=\"3424\" data-end=\"3472\"><strong data-start=\"3424\" data-end=\"3440\">Captura de dados<\/strong><br data-start=\"3440\" data-end=\"3443\" \/>Registar os principais dados, incluindo:<\/p><ul data-start=\"3476\" data-end=\"3597\"><li data-start=\"3476\" data-end=\"3500\"><p data-start=\"3478\" data-end=\"3500\">For\u00e7a de rutura (f\u2080)<\/p><\/li><li data-start=\"3504\" data-end=\"3526\"><p data-start=\"3506\" data-end=\"3526\">For\u00e7a de deslizamento m\u00e9dia (F)<\/p><\/li><li data-start=\"3530\" data-end=\"3558\"><p data-start=\"3532\" data-end=\"3558\">For\u00e7a m\u00e1xima de deslizamento (F\u2098\u2090\u2093)<\/p><\/li><li data-start=\"3562\" data-end=\"3597\"><p data-start=\"3564\" data-end=\"3597\">Dist\u00e2ncia de viagem e dura\u00e7\u00e3o do ensaio<\/p><\/li><\/ul><\/li><li data-start=\"3599\" data-end=\"3739\"><p data-start=\"3602\" data-end=\"3739\"><strong data-start=\"3602\" data-end=\"3616\">Avalia\u00e7\u00e3o<\/strong><br data-start=\"3616\" data-end=\"3619\" \/>Os resultados s\u00e3o comparados com os limites de especifica\u00e7\u00e3o das normas ISO 7886-1, ISO 11040-4 ou ISO 8537, consoante o tipo de seringa.<\/p><\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94fd533 e-flex e-con-boxed e-con e-parent\" data-id=\"94fd533\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f724e30 elementor-widget elementor-widget-heading\" data-id=\"f724e30\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Problemas comuns detectados atrav\u00e9s de testes de for\u00e7a de deslizamento<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-422d4c4 e-flex e-con-boxed e-con e-parent\" data-id=\"422d4c4\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbff8ed elementor-widget elementor-widget-text-editor\" data-id=\"dbff8ed\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3802\" data-end=\"3888\">Os testes de for\u00e7a de rutura e deslizamento revelam problemas cr\u00edticos de qualidade da seringa, tais como:<\/p><ul data-start=\"3890\" data-end=\"4134\"><li data-start=\"3890\" data-end=\"3961\"><p data-start=\"3892\" data-end=\"3961\"><strong data-start=\"3892\" data-end=\"3914\">Fric\u00e7\u00e3o excessiva<\/strong> devido a um revestimento de silicone insuficiente ou irregular<\/p><\/li><li data-start=\"3962\" data-end=\"4012\"><p data-start=\"3964\" data-end=\"4012\"><strong data-start=\"3964\" data-end=\"3985\">\u00eambolos colados<\/strong>que afectam a precis\u00e3o da dose<\/p><\/li><li data-start=\"4013\" data-end=\"4072\"><p data-start=\"4015\" data-end=\"4072\"><strong data-start=\"4015\" data-end=\"4043\">Incompatibilidade de materiais<\/strong> entre o tambor e o \u00eambolo<\/p><\/li><li data-start=\"4073\" data-end=\"4134\"><p data-start=\"4075\" data-end=\"4134\"><strong data-start=\"4075\" data-end=\"4100\">Desconex\u00e3o do \u00eambolo<\/strong> ou fuga de veda\u00e7\u00e3o sob for\u00e7a axial<\/p><\/li><\/ul><p data-start=\"4136\" data-end=\"4237\">A identifica\u00e7\u00e3o destes problemas durante a I&amp;D ou a produ\u00e7\u00e3o protege os processos a jusante e os resultados dos doentes.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-358cd95 e-flex e-con-boxed e-con e-parent\" data-id=\"358cd95\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1be87be elementor-widget elementor-widget-heading\" data-id=\"1be87be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Equipamento recomendado: Testador de resist\u00eancia de deslizamento de seringa SSR-01 da Cell Instruments<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-97d0577 e-flex e-con-boxed e-con e-parent\" data-id=\"97d0577\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4f6c718 e-con-full e-flex e-con e-child\" data-id=\"4f6c718\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-495d6e6 elementor-widget elementor-widget-text-editor\" data-id=\"495d6e6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4330\" data-end=\"4474\">Para executar estes testes com precis\u00e3o e em conformidade com as normas ISO, a Cell Instruments oferece o<a href=\"https:\/\/www.pharmacopoeiatest.com\/pt\/syringes-plunger-glide-force-tester\/\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"4430\" data-end=\"4440\">SSR-01<\/strong><\/a>. Este instrumento foi concebido para:<\/p><ul data-start=\"4476\" data-end=\"4766\"><li data-start=\"4476\" data-end=\"4534\"><p data-start=\"4478\" data-end=\"4534\"><strong data-start=\"4478\" data-end=\"4501\">Medi\u00e7\u00e3o exacta<\/strong> de for\u00e7a de rutura e de deslizamento<\/p><\/li><li data-start=\"4535\" data-end=\"4596\"><p data-start=\"4537\" data-end=\"4596\"><strong data-start=\"4537\" data-end=\"4563\">Velocidades de teste ajust\u00e1veis<\/strong> e defini\u00e7\u00f5es de teste program\u00e1veis<\/p><\/li><li data-start=\"4597\" data-end=\"4657\"><p data-start=\"4599\" data-end=\"4657\"><strong data-start=\"4599\" data-end=\"4625\">Visualiza\u00e7\u00e3o de dados em tempo real<\/strong> atrav\u00e9s de um ecr\u00e3 t\u00e1til HMI de 7 polegadas<\/p><\/li><li data-start=\"4658\" data-end=\"4712\"><p data-start=\"4660\" data-end=\"4712\"><strong data-start=\"4660\" data-end=\"4686\">Micro-impressora incorporada<\/strong> para comunica\u00e7\u00e3o imediata<\/p><\/li><li data-start=\"4713\" data-end=\"4766\"><p data-start=\"4715\" data-end=\"4766\"><strong data-start=\"4715\" data-end=\"4736\">Dispositivos flex\u00edveis<\/strong> para diferentes formatos de seringa<\/p><\/li><\/ul><p data-start=\"4768\" data-end=\"4893\">A sua interface intuitiva e o seu desempenho robusto tornam-no ideal para <strong data-start=\"4838\" data-end=\"4859\">garantia de qualidade<\/strong> e <strong data-start=\"4864\" data-end=\"4892\">laborat\u00f3rios de desenvolvimento de produtos<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7285d35 e-con-full e-flex e-con e-child\" data-id=\"7285d35\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f5e0678 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"f5e0678\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp\" class=\"attachment-medium_large size-medium_large wp-image-2227\" alt=\"a M\u00e1quina de Teste de For\u00e7a de Desprendimento e Deslizamento - uma solu\u00e7\u00e3o vers\u00e1til e de alta precis\u00e3o adaptada para testes de seringas e materiais de embalagem.\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-1024x1024.webp 1024w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1.webp 1080w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d9ef370 e-flex e-con-boxed e-con e-parent\" data-id=\"d9ef370\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-354bdaf elementor-widget elementor-widget-heading\" data-id=\"354bdaf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Porque \u00e9 que este teste \u00e9 importante para os fabricantes<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9e66002 e-flex e-con-boxed e-con e-parent\" data-id=\"9e66002\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-aae1c87 e-con-full e-flex e-con e-child\" data-id=\"aae1c87\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf49733 elementor-widget elementor-widget-video\" data-id=\"bf49733\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=Jv55XhLaURk&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;modestbranding&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2cf2943 e-con-full e-flex e-con e-child\" data-id=\"2cf2943\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c0dc11 elementor-widget elementor-widget-text-editor\" data-id=\"0c0dc11\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"4948\" data-end=\"5007\"><p data-start=\"4950\" data-end=\"5007\"><strong data-start=\"4950\" data-end=\"4981\">Apoia os registos regulamentares<\/strong> com dados em conformidade com a norma ISO<\/p><\/li><li data-start=\"5008\" data-end=\"5082\"><p data-start=\"5010\" data-end=\"5082\"><strong data-start=\"5010\" data-end=\"5040\">Melhora a usabilidade do produto<\/strong> eliminando a ader\u00eancia ou o fluxo irregular<\/p><\/li><li data-start=\"5083\" data-end=\"5144\"><p data-start=\"5085\" data-end=\"5144\"><strong data-start=\"5085\" data-end=\"5115\">Aumenta a uniformidade dos lotes<\/strong> para produ\u00e7\u00e3o de grandes volumes<\/p><\/li><li data-start=\"5145\" data-end=\"5201\"><p data-start=\"5147\" data-end=\"5201\"><strong data-start=\"5147\" data-end=\"5173\">Reduz o risco de recolha<\/strong> devido a falha mec\u00e2nica<\/p><\/li><li data-start=\"5202\" data-end=\"5283\"><p data-start=\"5204\" data-end=\"5283\"><strong data-start=\"5204\" data-end=\"5232\">Aumenta o conforto do paciente<\/strong>especialmente para auto-injectores e seringas de insulina<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0c0191b e-flex e-con-boxed e-con e-parent\" data-id=\"0c0191b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4180a60 elementor-widget elementor-widget-heading\" data-id=\"4180a60\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclus\u00e3o<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fa9b8b6 e-flex e-con-boxed e-con e-parent\" data-id=\"fa9b8b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-28ecdb2 elementor-widget elementor-widget-text-editor\" data-id=\"28ecdb2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5306\" data-end=\"5729\"><strong data-start=\"5306\" data-end=\"5345\">Teste de for\u00e7a de rutura e deslizamento<\/strong> \u00e9 uma parte fundamental da avalia\u00e7\u00e3o da qualidade das seringas. Aderir a <a href=\"https:\/\/www.pharmacopoeiatest.com\/pt\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5411\" data-end=\"5425\">ISO 7886-1<\/strong><\/a>, <strong data-start=\"5427\" data-end=\"5442\">ISO 11040-4<\/strong>e <strong data-start=\"5448\" data-end=\"5460\">ISO 8537<\/strong> garante a fiabilidade dos produtos, a conformidade regulamentar e a seguran\u00e7a na administra\u00e7\u00e3o de medicamentos. Ao investir em instrumentos avan\u00e7ados como o <strong data-start=\"5583\" data-end=\"5615\">SSR-01 de<a href=\"https:\/\/www.celtec.cn\" target=\"_blank\" rel=\"noopener\"> Instrumentos celulares<\/a><\/strong>Com a ajuda de um sistema de gest\u00e3o de seringas, os fabricantes podem fornecer com confian\u00e7a seringas de elevado desempenho que satisfazem as expectativas da ind\u00fastria e dos doentes.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Testes de for\u00e7a de quebra e deslizamento: Um indicador-chave do desempenho da seringa Nas ind\u00fastrias farmac\u00eautica e de dispositivos m\u00e9dicos, o teste de for\u00e7a de quebra e deslizamento \u00e9 um procedimento cr\u00edtico utilizado para avaliar a usabilidade e a qualidade das seringas. Estes testes determinam a quantidade de for\u00e7a necess\u00e1ria para iniciar (soltar) e continuar (deslizar) o movimento [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2225","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/pt\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Break Loose and Glide Force Testing: A Key Indicator of Syringe Performance In the pharmaceutical and medical device industries, break loose and glide force testing is a critical procedure used to evaluate the usability and quality of syringes. These tests determine how much force is required to start (break loose) and continue (glide) the movement&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts\/2225","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/comments?post=2225"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts\/2225\/revisions"}],"predecessor-version":[{"id":2251,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts\/2225\/revisions\/2251"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/media?parent=2225"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/categories?post=2225"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/tags?post=2225"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}