{"id":2087,"date":"2025-04-27T08:38:09","date_gmt":"2025-04-27T08:38:09","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2087"},"modified":"2025-04-27T08:47:19","modified_gmt":"2025-04-27T08:47:19","slug":"luer-lock-rings-pull-off-force-test","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/pt\/luer-lock-rings-pull-off-force-test\/","title":{"rendered":"Teste de for\u00e7a de arrancamento de an\u00e9is Luer Lock - ISO 11040-4 Anexo G3"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2087\" class=\"elementor elementor-2087\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a57182 e-flex e-con-boxed e-con e-parent\" data-id=\"7a57182\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-caf1aa9 elementor-widget elementor-widget-heading\" data-id=\"caf1aa9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">An\u00e9is Luer Lock For\u00e7a de arranque<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27efcf2 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"27efcf2\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49edf54 elementor-widget elementor-widget-heading\" data-id=\"49edf54\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Anexo G3<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-03ddeb3 e-flex e-con-boxed e-con e-parent\" data-id=\"03ddeb3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ccea8f2 elementor-widget elementor-widget-text-editor\" data-id=\"ccea8f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"455\" data-end=\"1006\">Nos sectores farmac\u00eautico e dos dispositivos m\u00e9dicos, a <em data-start=\"531\" data-end=\"563\">an\u00e9is de bloqueio luer for\u00e7a de extra\u00e7\u00e3o<\/em> \u00e9 um par\u00e2metro cr\u00edtico para garantir a fiabilidade e a seguran\u00e7a das seringas pr\u00e9-cheias. O teste correto verifica a fixa\u00e7\u00e3o segura do adaptador de fecho luer lock (LLA) para evitar o desprendimento acidental durante a utiliza\u00e7\u00e3o.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c963d8 elementor-widget elementor-widget-heading\" data-id=\"0c963d8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Import\u00e2ncia da for\u00e7a de extra\u00e7\u00e3o dos an\u00e9is Luer Lock<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee545a5 elementor-widget elementor-widget-text-editor\" data-id=\"ee545a5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1013\" data-end=\"1449\">O <em data-start=\"1076\" data-end=\"1108\">an\u00e9is de bloqueio luer for\u00e7a de extra\u00e7\u00e3o<\/em> mede a for\u00e7a axial necess\u00e1ria para separar o sistema de colarinho LLA do corpo da seringa. Testes exactos garantem que a seringa mant\u00e9m a integridade durante o manuseamento, enchimento e administra\u00e7\u00e3o, reduzindo o risco de falha do dispositivo. As normas regulamentares exigem estes testes para proteger a seguran\u00e7a dos doentes e apoiar as declara\u00e7\u00f5es de desempenho do produto.<\/p><p class=\"\" data-start=\"1451\" data-end=\"1734\">Para os fabricantes e ag\u00eancias de inspe\u00e7\u00e3o de qualidade, especialmente os que servem os mercados m\u00e9dico, farmac\u00eautico e de cuidados de sa\u00fade, \u00e9 essencial dominar este teste. <strong data-start=\"1610\" data-end=\"1630\">Instrumentos celulares<\/strong> fornece solu\u00e7\u00f5es avan\u00e7adas que satisfazem estes requisitos rigorosos com elevada precis\u00e3o e fiabilidade.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4912cb5 elementor-widget elementor-widget-heading\" data-id=\"4912cb5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Requisito do anexo G3 da norma ISO 11040-4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9bf8207 elementor-widget elementor-widget-text-editor\" data-id=\"9bf8207\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1741\" data-end=\"2070\"><em data-start=\"1838\" data-end=\"1851\">ISO 11040-4<\/em> define os requisitos aplic\u00e1veis aos recipientes de vidro para inject\u00e1veis e \u00e0s seringas submontadas esterilizadas prontas a encher. Especificamente, <em data-start=\"1981\" data-end=\"2003\">ISO 11040-4 Anexo G3<\/em> pormenoriza o m\u00e9todo de medi\u00e7\u00e3o <em data-start=\"2037\" data-end=\"2069\">an\u00e9is de bloqueio luer for\u00e7a de extra\u00e7\u00e3o<\/em>.<\/p><p class=\"\" data-start=\"2072\" data-end=\"2096\">De acordo com o Anexo G3:<\/p><ul data-start=\"2097\" data-end=\"2989\"><li class=\"\" data-start=\"2097\" data-end=\"2237\"><p class=\"\" data-start=\"2099\" data-end=\"2237\"><strong data-start=\"2099\" data-end=\"2112\">Princ\u00edpio<\/strong>: O teste avalia se o sistema LLA pode resistir a uma for\u00e7a de tra\u00e7\u00e3o axial definida quando ligado a um encaixe luer padr\u00e3o.<\/p><\/li><li class=\"\" data-start=\"2238\" data-end=\"2444\"><p class=\"\" data-start=\"2240\" data-end=\"2444\"><strong data-start=\"2240\" data-end=\"2253\">Aparelhos<\/strong>: \u00c9 necess\u00e1ria uma m\u00e1quina universal de ensaio de tra\u00e7\u00e3o e compress\u00e3o, capaz de funcionar a uma velocidade de <strong data-start=\"2346\" data-end=\"2373\">velocidade de ensaio de 20 mm\/min<\/strong>. Uma c\u00e9lula de carga com uma gama t\u00edpica de <strong data-start=\"2411\" data-end=\"2428\">10 N a 100 N<\/strong> deve ser utilizado.<\/p><\/li><li class=\"\" data-start=\"2445\" data-end=\"2524\"><p class=\"\" data-start=\"2447\" data-end=\"2524\"><strong data-start=\"2447\" data-end=\"2462\">Prepara\u00e7\u00e3o<\/strong>: As amostras de ensaio devem corresponder \u00e0s condi\u00e7\u00f5es do processo de produ\u00e7\u00e3o.<\/p><\/li><li class=\"\" data-start=\"2525\" data-end=\"2751\"><p class=\"\" data-start=\"2527\" data-end=\"2751\"><strong data-start=\"2527\" data-end=\"2540\">Procedimento<\/strong>: Ap\u00f3s remover a tampa da ponta, a seringa \u00e9 posicionada num suporte sem aplicar press\u00e3o pr\u00e9via \u00e0 LLA. A m\u00e1quina puxa ent\u00e3o a uma velocidade constante at\u00e9 o colar da LLA se soltar, registando o pico de for\u00e7a.<\/p><\/li><li class=\"\" data-start=\"2752\" data-end=\"2851\"><p class=\"\" data-start=\"2754\" data-end=\"2851\"><strong data-start=\"2754\" data-end=\"2765\">Resultados<\/strong>: A for\u00e7a de pico da curva for\u00e7a-deslocamento representa a resist\u00eancia ao arrancamento.<\/p><\/li><li class=\"\" data-start=\"2852\" data-end=\"2989\"><p class=\"\" data-start=\"2854\" data-end=\"2989\"><strong data-start=\"2854\" data-end=\"2871\">Documenta\u00e7\u00e3o<\/strong>: O relat\u00f3rio deve incluir a velocidade de ensaio, o valor de pico, o n\u00famero de amostras, os resultados de aprova\u00e7\u00e3o\/reprova\u00e7\u00e3o e quaisquer desvios observados.<\/p><\/li><\/ul><p class=\"\" data-start=\"2991\" data-end=\"3102\">A seguir <em data-start=\"3001\" data-end=\"3023\">ISO 11040-4 Anexo G3<\/em> garante que os resultados s\u00e3o fi\u00e1veis, reprodut\u00edveis e internacionalmente aceites.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd67e63 elementor-widget elementor-widget-heading\" data-id=\"cd67e63\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Como efetuar o teste de for\u00e7a de arrancamento dos an\u00e9is Luer Lock<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec7a39c elementor-widget elementor-widget-text-editor\" data-id=\"ec7a39c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3109\" data-end=\"3263\">Realiza\u00e7\u00e3o de uma an\u00e1lise exacta <a href=\"https:\/\/www.pharmacopoeiatest.com\/pt\/luer-lock-rings-pull-off-force-test\/\"><em data-start=\"3193\" data-end=\"3225\">an\u00e9is de bloqueio luer for\u00e7a de extra\u00e7\u00e3o<\/em> teste<\/a> envolve v\u00e1rias etapas cr\u00edticas:<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-08466dd e-con-full e-flex e-con e-child\" data-id=\"08466dd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-33a3c77 elementor-widget elementor-widget-text-editor\" data-id=\"33a3c77\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>1. Prepara\u00e7\u00e3o da amostra<\/strong><\/p><ul><li data-start=\"3292\" data-end=\"3363\">Utilizar seringas submontadas esterilizadas que reflictam as condi\u00e7\u00f5es de produ\u00e7\u00e3o.<\/li><li data-start=\"3292\" data-end=\"3363\">Retirar a tampa da ponta sem sobrecarregar o sistema de colarinho LLA.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d451ca elementor-widget elementor-widget-text-editor\" data-id=\"5d451ca\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3427\" data-end=\"3452\"><strong>2. Configurar o teste<\/strong><\/p><ul><li data-start=\"3455\" data-end=\"3551\">Montar a seringa no <strong data-start=\"3480\" data-end=\"3498\">suporte de seringa<\/strong> e fixar o colarinho LLA no <strong data-start=\"3532\" data-end=\"3550\">dispositivo de preens\u00e3o<\/strong>.<\/li><li data-start=\"3455\" data-end=\"3551\">Assegurar que n\u00e3o \u00e9 exercida qualquer press\u00e3o sobre o colarinho durante a montagem.<\/li><li data-start=\"3455\" data-end=\"3551\">Calibrar a c\u00e9lula de carga para \"zero\" sem aplicar pr\u00e9-carga.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-95882a3 e-con-full e-flex e-con e-child\" data-id=\"95882a3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b1efd9c elementor-widget elementor-widget-text-editor\" data-id=\"b1efd9c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3675\" data-end=\"3699\"><strong>Execu\u00e7\u00e3o do teste<\/strong><\/p><ul><li>Ajustar a velocidade da m\u00e1quina para <strong data-start=\"3727\" data-end=\"3740\">20 mm\/min<\/strong>.<\/li><li>Iniciar o teste de tra\u00e7\u00e3o, monitorizando a for\u00e7a versus o deslocamento.<\/li><li>Registar o pico de for\u00e7a quando o colar LLA se soltar da seringa.<\/li><\/ul><p class=\"\" data-start=\"3875\" data-end=\"3902\"><strong data-start=\"3875\" data-end=\"3900\">Analisar os resultados<\/strong><\/p><ul><li data-start=\"3905\" data-end=\"3964\">Identificar o ponto mais alto do gr\u00e1fico for\u00e7a-deslocamento.<\/li><li data-start=\"3905\" data-end=\"3964\">Compare-o com os limites especificados para determinar a aprova\u00e7\u00e3o ou reprova\u00e7\u00e3o.<\/li><li data-start=\"3905\" data-end=\"3964\">Documentar todos os par\u00e2metros, incluindo as quantidades de amostras, as falhas e os desvios.<\/li><\/ul><p class=\"\" data-start=\"4110\" data-end=\"4222\">A <strong data-start=\"4112\" data-end=\"4139\">taxa de amostragem de 500 Hz<\/strong> \u00e9 recomendado para garantir a capta\u00e7\u00e3o de medi\u00e7\u00f5es de pico exactas durante o teste.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37beef7 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"37beef7\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"496\" height=\"500\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp\" class=\"attachment-full size-full wp-image-2089\" alt=\"Teste de for\u00e7a de arrancamento de an\u00e9is Luer Lock - ISO 11040-4 Anexo G3\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp 496w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-298x300.webp 298w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-150x150.webp 150w\" sizes=\"(max-width: 496px) 100vw, 496px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fe809e1 e-con-full e-flex e-con e-child\" data-id=\"fe809e1\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-517a11d e-con-full e-flex e-con e-child\" data-id=\"517a11d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-661f7f9 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"661f7f9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"Ensaio de fugas em seringas ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-63b418a e-con-full e-flex e-con e-child\" data-id=\"63b418a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-45b4a2d elementor-widget elementor-widget-heading\" data-id=\"45b4a2d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Equipamento recomendado para testes exactos<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef6391d elementor-widget elementor-widget-text-editor\" data-id=\"ef6391d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4229\" data-end=\"4441\">Em <strong data-start=\"4281\" data-end=\"4301\">Instrumentos celulares<\/strong>, somos especializados em fornecer <strong data-start=\"4330\" data-end=\"4375\">aparelhos universais de teste de tra\u00e7\u00e3o e compress\u00e3o<\/strong> personalizados para aplica\u00e7\u00f5es de teste com seringas. Os nossos sistemas oferecem:<\/p><ul data-start=\"4442\" data-end=\"4731\"><li class=\"\" data-start=\"4442\" data-end=\"4503\"><p class=\"\" data-start=\"4444\" data-end=\"4503\">Amostragem de alta frequ\u00eancia (at\u00e9 500 Hz) para uma precis\u00e3o m\u00e1xima.<\/p><\/li><li class=\"\" data-start=\"4504\" data-end=\"4582\"><p class=\"\" data-start=\"4506\" data-end=\"4582\">Suportes de seringas personalizados e pin\u00e7as LLA em conformidade com as especifica\u00e7\u00f5es ISO.<\/p><\/li><li class=\"\" data-start=\"4583\" data-end=\"4658\"><p class=\"\" data-start=\"4585\" data-end=\"4658\">C\u00e9lulas de carga adequadas para uma gama de for\u00e7as de ensaio entre 10 N e 100 N.<\/p><\/li><li class=\"\" data-start=\"4659\" data-end=\"4731\"><p class=\"\" data-start=\"4661\" data-end=\"4731\">Software intuitivo para rastreabilidade total dos par\u00e2metros e relat\u00f3rios f\u00e1ceis.<\/p><\/li><\/ul><p class=\"\" data-start=\"4733\" data-end=\"4901\">As nossas solu\u00e7\u00f5es garantem a conformidade com <em data-start=\"4773\" data-end=\"4786\">ISO 11040-4<\/em> e ajudar a garantir a mais elevada qualidade dos produtos para os nossos clientes nas ind\u00fastrias farmac\u00eautica e de dispositivos m\u00e9dicos.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d05f85d elementor-widget elementor-widget-text-editor\" data-id=\"d05f85d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4908\" data-end=\"5324\">Compreender e medir com exatid\u00e3o os <em data-start=\"4968\" data-end=\"5000\">an\u00e9is de bloqueio luer for\u00e7a de extra\u00e7\u00e3o<\/em> de acordo com <em data-start=\"5014\" data-end=\"5036\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Anexo G3<\/em> \u00e9 crucial para garantir a seguran\u00e7a e fiabilidade das seringas. Seguindo os m\u00e9todos corretos e utilizando instrumentos de teste conformes e de alta precis\u00e3o da <strong data-start=\"5187\" data-end=\"5207\">Instrumentos celulares<\/strong>Com o sistema de controlo de qualidade, as equipas de controlo de qualidade podem verificar com confian\u00e7a o desempenho do produto, cumprir as normas regulamentares e proteger os utilizadores finais.<\/p><p class=\"\" data-start=\"5326\" data-end=\"5511\">Se precisar de ajuda para selecionar ou personalizar o equipamento de teste adequado para as suas necessidades de teste com seringas, <strong data-start=\"5437\" data-end=\"5471\">contactar a Cell Instruments hoje<\/strong> para explorar a nossa gama completa de solu\u00e7\u00f5es.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>For\u00e7a de arrancamento dos an\u00e9is Luer Lock ISO 11040-4 Anexo G3 Nas ind\u00fastrias farmac\u00eautica e de dispositivos m\u00e9dicos, a for\u00e7a de arrancamento dos an\u00e9is luer lock \u00e9 um par\u00e2metro cr\u00edtico para garantir a fiabilidade e seguran\u00e7a das seringas pr\u00e9-cheias. Um teste adequado verifica a fixa\u00e7\u00e3o segura do adaptador de fecho luer (LLA) para evitar o desprendimento acidental durante a utiliza\u00e7\u00e3o. Import\u00e2ncia do [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2087","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/pt\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Lock Rings Pull-Off Force ISO 11040-4 Annex G3 In the pharmaceutical and medical device industries, the luer lock rings pull-off force is a critical parameter to ensure the reliability and safety of prefilled syringes. Proper testing verifies the secure attachment of the luer lock adaptor (LLA) to prevent accidental detachment during use. Importance of&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts\/2087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/comments?post=2087"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts\/2087\/revisions"}],"predecessor-version":[{"id":2101,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/posts\/2087\/revisions\/2101"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/media?parent=2087"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/categories?post=2087"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pt\/wp-json\/wp\/v2\/tags?post=2087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}