{"id":2610,"date":"2026-05-07T08:15:19","date_gmt":"2026-05-07T08:15:19","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2610"},"modified":"2026-05-07T08:46:47","modified_gmt":"2026-05-07T08:46:47","slug":"iso-8537","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/pl\/iso-8537\/","title":{"rendered":"ISO 8537"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2610\" class=\"elementor elementor-2610\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0662493 e-flex e-con-boxed e-con e-parent\" data-id=\"0662493\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fc37773 elementor-widget elementor-widget-heading\" data-id=\"fc37773\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8537 <br><small><small>Testowanie dzia\u0142ania strzykawki do podawania insuliny<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-25d7b19 e-con-full e-flex e-con e-child\" data-id=\"25d7b19\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d257432 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"d257432\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"314\" data-end=\"683\">Norma ISO 8537 okre\u015bla wymagania dotycz\u0105ce w\u0142a\u015bciwo\u015bci u\u017cytkowych i bada\u0144 dla <strong data-start=\"378\" data-end=\"417\">sterylne strzykawki do insuliny jednorazowego u\u017cytku<\/strong>, zar\u00f3wno z ig\u0142ami, jak i bez nich. Norma ta koncentruje si\u0119 na bezpiecze\u0144stwie strzykawek, ich funkcjonalno\u015bci, szczelno\u015bci, dok\u0142adno\u015bci dawkowania oraz niezawodno\u015bci dzia\u0142ania. Producenci i laboratoria kontroli jako\u015bci stosuj\u0105 norm\u0119 ISO 8537 w celu sprawdzenia, czy strzykawki dzia\u0142aj\u0105 sp\u00f3jnie podczas stosowania klinicznego.<\/p><p data-start=\"685\" data-end=\"1021\">Dla producent\u00f3w strzykawek zgodno\u015b\u0107 z norm\u0105 ISO 8537 zwi\u0119ksza niezawodno\u015b\u0107 produkt\u00f3w, u\u0142atwia procesy rejestracji produkt\u00f3w oraz ogranicza ryzyko zwi\u0105zane z wyciekami, awariami t\u0142oka lub niedok\u0142adnym dozowaniem. Laboratoriom kontroli jako\u015bci norma ta zapewnia sprawdzone procedury oceny dzia\u0142ania strzykawek w kontrolowanych warunkach.<\/p><p data-start=\"1023\" data-end=\"1207\">Poniewa\u017c strzykawki insulinowe wymagaj\u0105 precyzyjnego podawania i stabilnego uszczelnienia, <strong data-start=\"1105\" data-end=\"1138\">Testowanie funkcjonalno\u015bci strzykawki<\/strong> odgrywa kluczow\u0105 rol\u0119 na wszystkich etapach rozwoju i produkcji produktu.<\/p><p data-start=\"1209\" data-end=\"1536\">Firma Cell Instruments dostarcza specjalistyczne systemy testowe przeznaczone dla producent\u00f3w strzykawek, laboratori\u00f3w zajmuj\u0105cych si\u0119 wyrobami medycznymi oraz zespo\u0142\u00f3w ds. jako\u015bci opakowa\u0144 farmaceutycznych. Urz\u0105dzenia te umo\u017cliwiaj\u0105 automatyczny pomiar si\u0142y, ocen\u0119 szczelno\u015bci pr\u00f3\u017cniowej, badania szczelno\u015bci oraz analiz\u0119 przestrzeni martwej zgodnie z metodami okre\u015blonymi w normie ISO 8537.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b939f5 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"5b939f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"630\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes.webp\" class=\"attachment-full size-full wp-image-2613\" alt=\"ISO 8537 \u2013 Badanie funkcjonalno\u015bci strzykawek insulinowych\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes.webp 500w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes-238x300.webp 238w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes-10x12.webp 10w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77936bb elementor-widget elementor-widget-heading\" data-id=\"77936bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 8537 \u2013 Badanie sprawno\u015bci strzykawek<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e0637a3 e-grid e-con-full e-con e-child\" data-id=\"e0637a3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d71bda6 elementor-widget elementor-widget-text-editor\" data-id=\"d71bda6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1586\" data-end=\"1769\">Norma ISO 8537 obejmuje szereg bada\u0144 wydajno\u015bciowych, kt\u00f3re pozwalaj\u0105 ustali\u0107, czy strzykawka mo\u017ce dzia\u0142a\u0107 bezpiecznie i precyzyjnie podczas zasysania i wstrzykiwania. Norma ta obejmuje badania dotycz\u0105ce:<\/p><ul data-start=\"1771\" data-end=\"1938\"><li data-section-id=\"1oxsryt\" data-start=\"1771\" data-end=\"1802\">Wyciek powietrza podczas aspiracji<\/li><li data-section-id=\"b62ksi\" data-start=\"1803\" data-end=\"1837\">Wyciek cieczy pod wp\u0142ywem \u015bciskania<\/li><li data-section-id=\"143ln9z\" data-start=\"1838\" data-end=\"1862\">Si\u0142a robocza t\u0142oka<\/li><li data-section-id=\"1trb4xg\" data-start=\"1863\" data-end=\"1879\">Szczelno\u015b\u0107 uszczelnienia<\/li><li data-section-id=\"77dvwg\" data-start=\"1880\" data-end=\"1899\">Obj\u0119to\u015b\u0107 przestrzeni martwej<\/li><li data-section-id=\"gfc932\" data-start=\"1900\" data-end=\"1938\">Nieszczelno\u015b\u0107 po\u0142\u0105czenia ig\u0142y z dysz\u0105<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d841201 elementor-widget elementor-widget-text-editor\" data-id=\"d841201\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1940\" data-end=\"1978\">Testy te pomagaj\u0105 producentom oceni\u0107:<\/p><ul data-start=\"1980\" data-end=\"2145\"><li data-section-id=\"4m7yx6\" data-start=\"1980\" data-end=\"2009\">Jednorodno\u015b\u0107 uszczelnienia t\u0142oka<\/li><li data-section-id=\"jtny4m\" data-start=\"2010\" data-end=\"2039\">Ci\u0105g\u0142o\u015b\u0107 korpusu i dyszy<\/li><li data-section-id=\"13p4qmo\" data-start=\"2040\" data-end=\"2067\">Skuteczno\u015b\u0107 smarowania<\/li><li data-section-id=\"1rxkfq7\" data-start=\"2068\" data-end=\"2093\">Precyzja podawania dawki<\/li><li data-section-id=\"njxgtt\" data-start=\"2094\" data-end=\"2145\">Niezawodno\u015b\u0107 po\u0142\u0105czenia mi\u0119dzy strzykawk\u0105 a ig\u0142\u0105<\/li><\/ul><p data-start=\"2147\" data-end=\"2270\">Wsp\u00f3\u0142czesne laboratoria coraz cz\u0119\u015bciej wdra\u017caj\u0105 zautomatyzowane systemy badawcze w celu poprawy powtarzalno\u015bci wynik\u00f3w i ograniczenia zmienno\u015bci wynikaj\u0105cej z dzia\u0142a\u0144 operatora.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84b6ee2 elementor-widget elementor-widget-heading\" data-id=\"84b6ee2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Badanie szczelno\u015bci strzykawek zgodnie z norm\u0105 ISO 8537<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d186872 elementor-widget elementor-widget-text-editor\" data-id=\"d186872\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2324\" data-end=\"2507\"><strong data-start=\"2324\" data-end=\"2348\">Testowanie szczelno\u015bci strzykawki<\/strong> jest jedn\u0105 z najwa\u017cniejszych procedur opisanych w normie ISO 8537. Norma ta pozwala oceni\u0107 zar\u00f3wno nieszczelno\u015b\u0107 powietrzn\u0105, jak i nieszczelno\u015b\u0107 cieczy w r\u00f3\u017cnych warunkach ci\u015bnieniowych.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-47c3651 e-grid e-con-full e-con e-child\" data-id=\"47c3651\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-bd0c720 e-con-full e-flex e-con e-child\" data-id=\"bd0c720\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb605b0 elementor-widget elementor-widget-heading\" data-id=\"eb605b0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wyciek powietrza podczas odsysania<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1310954 elementor-widget elementor-widget-text-editor\" data-id=\"1310954\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2544\" data-end=\"2684\">W za\u0142\u0105czniku B i za\u0142\u0105czniku F opisano metody wykrywania wyciek\u00f3w powietrza w okolicy uszczelnienia t\u0142oka oraz po\u0142\u0105cze\u0144 dyszy strzykawki w warunkach pr\u00f3\u017cniowych.<\/p><p data-start=\"2686\" data-end=\"2719\">Procedura zazwyczaj obejmuje:<\/p><ol data-start=\"2721\" data-end=\"2926\"><li data-section-id=\"8f51yc\" data-start=\"2721\" data-end=\"2764\">Nape\u0142nianie strzykawki wod\u0105 destylowan\u0105<\/li><li data-section-id=\"11xil91\" data-start=\"2765\" data-end=\"2822\">Pod\u0142\u0105czenie strzykawki do kompatybilnego z\u0142\u0105cza sto\u017ckowego<\/li><li data-section-id=\"1w8sjai\" data-start=\"2823\" data-end=\"2852\">Stosowanie podci\u015bnienia<\/li><li data-section-id=\"nzi51v\" data-start=\"2853\" data-end=\"2885\">Monitorowanie stabilno\u015bci ci\u015bnienia<\/li><li data-section-id=\"ad7xt5\" data-start=\"2886\" data-end=\"2926\">Stwierdzenie wycieku lub tworzenia si\u0119 p\u0119cherzyk\u00f3w<\/li><\/ol><p data-start=\"2928\" data-end=\"3143\">Norma ISO 8537 okre\u015bla poziom pr\u00f3\u017cni wynosz\u0105cy <strong data-start=\"2965\" data-end=\"3010\">88 kPa poni\u017cej ci\u015bnienia atmosferycznego otoczenia<\/strong> w celu oceny szczelno\u015bci uk\u0142adu odsysaj\u0105cego. Operatorzy obserwuj\u0105 strzykawk\u0119 pod k\u0105tem spadku ci\u015bnienia, tworzenia si\u0119 p\u0119cherzyk\u00f3w powietrza oraz oddzielania si\u0119 gumowego korka.<\/p><p data-start=\"3145\" data-end=\"3164\">Ten test sprawdza:<\/p><ul data-start=\"3166\" data-end=\"3287\"><li data-section-id=\"31dbu3\" data-start=\"3166\" data-end=\"3189\">Nienaruszalno\u015b\u0107 uszczelnienia t\u0142oka<\/li><li data-section-id=\"10m5ixj\" data-start=\"3190\" data-end=\"3222\">Skuteczno\u015b\u0107 uszczelnienia z\u0142\u0105cza ig\u0142y<\/li><li data-section-id=\"17ziab\" data-start=\"3223\" data-end=\"3252\">Stabilno\u015b\u0107 po\u0142\u0105czenia dyszy<\/li><li data-section-id=\"1way5n8\" data-start=\"3253\" data-end=\"3287\">Odporno\u015b\u0107 na wyciek podczas aspiracji<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28726d3 e-con-full e-flex e-con e-child\" data-id=\"28726d3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4cf6b78 elementor-widget elementor-widget-heading\" data-id=\"4cf6b78\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pr\u00f3ba szczelno\u015bci pr\u00f3\u017cniowej \u2013 zastosowania w przemy\u015ble farmaceutycznym<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a833751 elementor-widget elementor-widget-text-editor\" data-id=\"a833751\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3339\" data-end=\"3513\">A <strong data-start=\"3341\" data-end=\"3376\">pr\u00f3ba szczelno\u015bci pr\u00f3\u017cniowej w przemy\u015ble farmaceutycznym<\/strong> Procedura ta ma zasadnicze znaczenie w przypadku strzykawek medycznych stosowanych do podawania insuliny, poniewa\u017c nawet niewielki wyciek mo\u017ce wp\u0142yn\u0105\u0107 na dok\u0142adno\u015b\u0107 dawkowania lub sterylno\u015b\u0107.<\/p><p data-start=\"3515\" data-end=\"3595\">Firma Cell Instruments zaleca stosowanie zautomatyzowanych system\u00f3w do testowania szczelno\u015bci pr\u00f3\u017cniowej, wyposa\u017conych w:<\/p><ul data-start=\"3597\" data-end=\"3738\"><li data-section-id=\"le59d7\" data-start=\"3597\" data-end=\"3632\">Wysokoprecyzyjne regulatory pr\u00f3\u017cniowe<\/li><li data-section-id=\"1jdfnmj\" data-start=\"3633\" data-end=\"3662\">Cyfrowe monitorowanie ci\u015bnienia<\/li><li data-section-id=\"105a6xv\" data-start=\"3663\" data-end=\"3684\">Analiza zaniku wycieku<\/li><li data-section-id=\"fca3b5\" data-start=\"3685\" data-end=\"3712\">Programowalny czas utrzymywania<\/li><li data-section-id=\"cixp3u\" data-start=\"3713\" data-end=\"3738\">Oprogramowanie do rejestracji danych<\/li><\/ul><p data-start=\"3740\" data-end=\"3896\">Systemy te zapewniaj\u0105 wi\u0119ksz\u0105 powtarzalno\u015b\u0107 wynik\u00f3w w por\u00f3wnaniu z r\u0119cznymi metodami oceny pr\u00f3\u017cni i pomagaj\u0105 laboratoriom spe\u0142nia\u0107 wymagania dotycz\u0105ce dokumentacji wynikaj\u0105ce z GMP i norm ISO.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa6d2ef elementor-widget elementor-widget-heading\" data-id=\"fa6d2ef\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Metody badania szczelno\u015bci uszczelnie\u0144 strzykawek<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0cbf91c elementor-widget elementor-widget-text-editor\" data-id=\"0cbf91c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3943\" data-end=\"4074\">The <strong data-start=\"3947\" data-end=\"3978\">badanie szczelno\u015bci uszczelnienia strzykawki<\/strong> ocenia, czy podczas kompresji lub zasysania mo\u017ce dochodzi\u0107 do przedostawania si\u0119 cieczy lub powietrza przez po\u0142\u0105czenia uszczelniaj\u0105ce.<\/p><p data-start=\"4076\" data-end=\"4122\">Za\u0142\u0105cznik E do normy ISO 8537 dotyczy wyciek\u00f3w cieczy w nast\u0119puj\u0105cych miejscach:<\/p><ul data-start=\"4124\" data-end=\"4190\"><li data-section-id=\"z11dbz\" data-start=\"4124\" data-end=\"4138\">Uszczelnienia t\u0142ok\u00f3w<\/li><li data-section-id=\"1p89988\" data-start=\"4139\" data-end=\"4167\">Z\u0142\u0105cza dysz strzykawkowych<\/li><li data-section-id=\"1aynqcu\" data-start=\"4168\" data-end=\"4190\">Z\u0142\u0105cza iglicowo-cylindrowe<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b34aa1c e-grid e-con-full e-con e-child\" data-id=\"b34aa1c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7afb7c0 elementor-widget elementor-widget-text-editor\" data-id=\"7afb7c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4365\" data-end=\"4389\">Podczas test\u00f3w operatorzy wytwarzaj\u0105 ci\u015bnienie wewn\u0119trzne wynosz\u0105ce <strong data-start=\"4251\" data-end=\"4277\">300 kPa ci\u015bnienia manometrycznego<\/strong> i utrzymywa\u0107 nacisk przez 30 sekund, wywieraj\u0105c jednocze\u015bnie si\u0142\u0119 boczn\u0105 na t\u0142ok.<\/p><p data-start=\"4365\" data-end=\"4389\">Procedura ocenia:<\/p><ul data-start=\"4391\" data-end=\"4508\"><li data-section-id=\"1k1t3bu\" data-start=\"4391\" data-end=\"4420\">Odporno\u015b\u0107 uszczelki na odkszta\u0142cenia<\/li><li data-section-id=\"vhj5a5\" data-start=\"4421\" data-end=\"4457\">Przeciek w warunkach obci\u0105\u017cenia bocznego<\/li><li data-section-id=\"1ubek41\" data-start=\"4458\" data-end=\"4485\">Stabilno\u015b\u0107 ruchu t\u0142oka<\/li><li data-section-id=\"tj03kp\" data-start=\"4486\" data-end=\"4508\">Integralno\u015b\u0107 po\u0142\u0105czenia<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5283d17 elementor-widget elementor-widget-text-editor\" data-id=\"5283d17\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4510\" data-end=\"4558\">Niezawodny system kontroli szczelno\u015bci powinien zapewnia\u0107:<\/p><ul data-start=\"4560\" data-end=\"4689\"><li data-section-id=\"1ogn8km\" data-start=\"4560\" data-end=\"4588\">Stabilne wytwarzanie ci\u015bnienia<\/li><li data-section-id=\"81fo7t\" data-start=\"4589\" data-end=\"4617\">Precyzyjne wywieranie si\u0142y<\/li><li data-section-id=\"vtwu91\" data-start=\"4618\" data-end=\"4647\">Wykrywanie wyciek\u00f3w w czasie rzeczywistym<\/li><li data-section-id=\"198rl1a\" data-start=\"4648\" data-end=\"4689\">Monitorowanie przemieszcze\u0144 w wysokiej rozdzielczo\u015bci<\/li><\/ul><p data-start=\"4691\" data-end=\"4868\">Firma Cell Instruments oferuje rozwi\u0105zania w zakresie wykrywania wyciek\u00f3w ci\u015bnieniowych i kontroli szczelno\u015bci, przeznaczone do strzykawek insulinowych, system\u00f3w Luer, pojemnik\u00f3w farmaceutycznych oraz opakowa\u0144 medycznych.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1592e7 elementor-widget elementor-widget-heading\" data-id=\"d1592e7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testowanie si\u0142y po\u015blizgu strzykawki<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86fac58 elementor-widget elementor-widget-text-editor\" data-id=\"86fac58\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4907\" data-end=\"5032\"><strong data-start=\"4907\" data-end=\"4938\">Testowanie si\u0142y po\u015blizgu strzykawki<\/strong> mierzy si\u0142\u0119 niezb\u0119dn\u0105 do zainicjowania i utrzymania ruchu t\u0142oka podczas wyrzucania cieczy.<\/p><p data-start=\"5034\" data-end=\"5176\">W za\u0142\u0105czniku C do normy ISO 8537 okre\u015blono spos\u00f3b wykorzystania mechanicznej maszyny badawczej do rejestrowania si\u0142y nacisku t\u0142oka podczas wypychania wody ze strzykawki.<\/p><p data-start=\"5178\" data-end=\"5206\">Test ten zasadniczo mierzy:<\/p><ul data-start=\"5208\" data-end=\"5305\"><li data-section-id=\"uhip3k\" data-start=\"5208\" data-end=\"5227\">Si\u0142a wyrywaj\u0105ca<\/li><li data-section-id=\"d3dsxi\" data-start=\"5228\" data-end=\"5241\">Si\u0142a po\u015blizgu<\/li><li data-section-id=\"td0rt7\" data-start=\"5242\" data-end=\"5267\">\u015arednia si\u0142a robocza<\/li><li data-section-id=\"fqmeyx\" data-start=\"5268\" data-end=\"5305\">Zapewnij r\u00f3wnomierno\u015b\u0107 si\u0142y podczas ca\u0142ego ruchu<\/li><\/ul><p data-start=\"5307\" data-end=\"5456\">Stabilna charakterystyka si\u0142y po\u015blizgu ma kluczowe znaczenie, poniewa\u017c zbyt du\u017ca si\u0142a mo\u017ce ograniczy\u0107 wygod\u0119 u\u017cytkowania, natomiast zbyt ma\u0142y op\u00f3r mo\u017ce utrudni\u0107 kontrol\u0119 dawkowania.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18cc935 elementor-widget elementor-widget-heading\" data-id=\"18cc935\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">G\u0142\u00f3wne czynniki wp\u0142ywaj\u0105ce na si\u0142\u0119 \u015blizgow\u0105<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d703620 e-grid e-con-full e-con e-child\" data-id=\"d703620\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c02067 elementor-widget elementor-widget-text-editor\" data-id=\"5c02067\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5497\" data-end=\"5556\">Na w\u0142a\u015bciwo\u015bci \u015blizgowe strzykawki wp\u0142ywa kilka parametr\u00f3w:<\/p><ul data-start=\"5558\" data-end=\"5684\"><li data-section-id=\"1futzim\" data-start=\"5558\" data-end=\"5591\">R\u00f3wnomierno\u015b\u0107 smarowania silikonem<\/li><li data-section-id=\"kuh4lo\" data-start=\"5592\" data-end=\"5617\">Materia\u0142, z kt\u00f3rego wykonano gumowy korek<\/li><li data-section-id=\"53gmea\" data-start=\"5618\" data-end=\"5647\">Dok\u0142adno\u015b\u0107 wymiarowa lufy<\/li><li data-section-id=\"5t72bj\" data-start=\"5648\" data-end=\"5666\">Tarcie powierzchniowe<\/li><li data-section-id=\"198q7yk\" data-start=\"5667\" data-end=\"5684\">\u015arednica ig\u0142y<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9cd7bf elementor-widget elementor-widget-text-editor\" data-id=\"a9cd7bf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5686\" data-end=\"5745\">Profesjonalny system do badania si\u0142y strzykawki powinien obejmowa\u0107:<\/p><ul data-start=\"5747\" data-end=\"5906\"><li data-section-id=\"ne6nqw\" data-start=\"5747\" data-end=\"5779\">Technologia precyzyjnych czujnik\u00f3w wagowych<\/li><li data-section-id=\"1wxb0hx\" data-start=\"5780\" data-end=\"5811\">Sterowanie ruchem ze sta\u0142\u0105 pr\u0119dko\u015bci\u0105<\/li><li data-section-id=\"h51txm\" data-start=\"5812\" data-end=\"5847\">Analiza krzywej si\u0142a\u2013przemieszczenie<\/li><li data-section-id=\"gjpujf\" data-start=\"5848\" data-end=\"5874\">Regulowane uchwyty testowe<\/li><li data-section-id=\"19afykk\" data-start=\"5875\" data-end=\"5906\">Komputerowe gromadzenie danych<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef0db14 elementor-widget elementor-widget-text-editor\" data-id=\"ef0db14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Firma Cell Instruments zaleca stosowanie uniwersalnych system\u00f3w do bada\u0144 materia\u0142\u00f3w, wyposa\u017conych w dostosowane do indywidualnych potrzeb uchwyty do strzykawek, przeznaczonych do bada\u0144 si\u0142y t\u0142oka zgodnie z norm\u0105 ISO 8537.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4d61be elementor-widget elementor-widget-heading\" data-id=\"c4d61be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Skala \u201eDead Space\u201d w strzykawkach insulinowych<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2c205a elementor-widget elementor-widget-text-editor\" data-id=\"a2c205a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6115\" data-end=\"6239\"><strong data-start=\"6115\" data-end=\"6141\">Pomiar przestrzeni martwej<\/strong> okre\u015bla obj\u0119to\u015b\u0107 cieczy pozostaj\u0105c\u0105 w strzykawce po ca\u0142kowitym wci\u015bni\u0119ciu t\u0142oka.<\/p><p data-start=\"6241\" data-end=\"6394\">Ma\u0142a przestrze\u0144 martwa ma szczeg\u00f3lne znaczenie w przypadku strzykawek do insuliny, poniewa\u017c pozosta\u0142o\u015bci leku mog\u0105 wp\u0142ywa\u0107 na dok\u0142adno\u015b\u0107 dawkowania i zwi\u0119ksza\u0107 ilo\u015b\u0107 odpad\u00f3w farmaceutycznych.<\/p><p data-start=\"6396\" data-end=\"6484\">W za\u0142\u0105czniku D do normy ISO 8537 opisano grawimetryczn\u0105 metod\u0119 badawcz\u0105 opart\u0105 na pomiarze masy wody.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3582f04 e-grid e-con-full e-con e-child\" data-id=\"3582f04\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-e4e0eef e-con-full e-flex e-con e-child\" data-id=\"e4e0eef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ee7135a elementor-widget elementor-widget-heading\" data-id=\"ee7135a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Procedura pomiaru przestrzeni martwej<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60271a8 elementor-widget elementor-widget-text-editor\" data-id=\"60271a8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6524\" data-end=\"6547\">Procedura obejmuje:<\/p><ol data-start=\"6549\" data-end=\"6719\"><li data-section-id=\"5n54cf\" data-start=\"6549\" data-end=\"6578\">Zwa\u017cenie pustej strzykawki<\/li><li data-section-id=\"1po99wn\" data-start=\"6579\" data-end=\"6622\">Nape\u0142nianie strzykawki wod\u0105 destylowan\u0105<\/li><li data-section-id=\"q59tts\" data-start=\"6623\" data-end=\"6656\">Ca\u0142kowite usuni\u0119cie wody<\/li><li data-section-id=\"1w7zx7c\" data-start=\"6657\" data-end=\"6682\">Ponowne zwa\u017cenie strzykawki<\/li><li data-section-id=\"1bth81y\" data-start=\"6683\" data-end=\"6719\">Obliczanie obj\u0119to\u015bci zatrzymanej wody<\/li><\/ol><p data-start=\"6721\" data-end=\"6791\">Pozosta\u0142a obj\u0119to\u015b\u0107 wody odpowiada obj\u0119to\u015bci martwej przestrzeni strzykawki.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c8b1057 e-con-full e-flex e-con e-child\" data-id=\"c8b1057\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c4747c elementor-widget elementor-widget-heading\" data-id=\"7c4747c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Znaczenie test\u00f3w w przestrzeni martwej<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac04fa1 elementor-widget elementor-widget-text-editor\" data-id=\"ac04fa1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6831\" data-end=\"6883\">Pomiar przestrzeni martwej pomaga producentom w ocenie:<\/p><ul data-start=\"6885\" data-end=\"6993\"><li data-section-id=\"1yt1bzi\" data-start=\"6885\" data-end=\"6902\">Dok\u0142adno\u015b\u0107 dawkowania<\/li><li data-section-id=\"to7kax\" data-start=\"6903\" data-end=\"6928\">Pozosta\u0142o\u015bci leku w organizmie<\/li><li data-section-id=\"1uwyw95\" data-start=\"6929\" data-end=\"6962\">Optymalizacja konstrukcji strzykawki<\/li><li data-section-id=\"19wzgi9\" data-start=\"6963\" data-end=\"6993\">Wydajno\u015b\u0107 konstrukcji z\u0142\u0105cza ig\u0142y<\/li><\/ul><p data-start=\"6995\" data-end=\"7121\">Firma Cell Instruments oferuje integracj\u0119 wag precyzyjnych oraz dostosowane do indywidualnych potrzeb platformy testowe do automatycznej analizy przestrzeni martwej.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8195461 elementor-widget elementor-widget-heading\" data-id=\"8195461\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Zalecany sprz\u0119t badawczy zapewniaj\u0105cy zgodno\u015b\u0107 z norm\u0105 ISO 8537<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-129d4b6 elementor-widget elementor-widget-text-editor\" data-id=\"129d4b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"7186\" data-end=\"7244\">Aby zapewni\u0107 zgodno\u015b\u0107 z norm\u0105 ISO 8537, laboratoria zazwyczaj stosuj\u0105:<\/p><div class=\"TyagGW_tableContainer\"><div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"7246\" data-end=\"7579\"><thead data-start=\"7246\" data-end=\"7284\"><tr data-start=\"7246\" data-end=\"7284\"><th class=\"\" data-start=\"7246\" data-end=\"7258\" data-col-size=\"sm\">Pytanie testowe<\/th><th class=\"\" data-start=\"7258\" data-end=\"7284\" data-col-size=\"sm\">Zalecany instrument<\/th><\/tr><\/thead><tbody data-start=\"7295\" data-end=\"7579\"><tr data-start=\"7295\" data-end=\"7342\"><td style=\"text-align: center;\" data-start=\"7295\" data-end=\"7320\" data-col-size=\"sm\">Badanie szczelno\u015bci metod\u0105 pr\u00f3\u017cniow\u0105<\/td><td style=\"text-align: center;\" data-start=\"7320\" data-end=\"7342\" data-col-size=\"sm\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/vacuum-leak-tester-for-syringe-plunger-stopper-and-seal\/\">Tester szczelno\u015bci strzykawek SLT-02<\/a><\/td><\/tr><tr data-start=\"7402\" data-end=\"7456\"><td style=\"text-align: center;\" data-start=\"7402\" data-end=\"7427\" data-col-size=\"sm\">Si\u0142a robocza t\u0142oka<\/td><td style=\"text-align: center;\" data-start=\"7427\" data-end=\"7456\" data-col-size=\"sm\"><p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/syringes-plunger-glide-force-tester\/\">SSR-01 Tester oporu przesuwu strzykawki<\/a><\/p><\/td><\/tr><tr data-start=\"7457\" data-end=\"7513\"><td style=\"text-align: center;\" data-start=\"7457\" data-end=\"7479\" data-col-size=\"sm\">Analiza przestrzeni martwej<\/td><td style=\"text-align: center;\" data-start=\"7479\" data-end=\"7513\" data-col-size=\"sm\">System pomiar\u00f3w grawimetrycznych<\/td><\/tr><tr data-start=\"7514\" data-end=\"7579\"><td style=\"text-align: center;\" data-start=\"7514\" data-end=\"7543\" data-col-size=\"sm\">Badanie szczelno\u015bci po\u0142\u0105cze\u0144<\/td><td style=\"text-align: center;\" data-start=\"7543\" data-end=\"7579\" data-col-size=\"sm\"><div class=\"elementor-element elementor-element-9d87235 elementor-widget elementor-widget-heading\" data-id=\"9d87235\" data-element_type=\"widget\" data-widget_type=\"heading.default\"><div class=\"elementor-widget-container\"><p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/syringe-plunger-seal-integrity-tester\/\">SPPT-01 Tester szczelno\u015bci nadci\u015bnieniowej strzykawki<\/a><\/p><\/div><\/div><\/td><\/tr><\/tbody><\/table><\/div><\/div><p data-start=\"7581\" data-end=\"7773\">Firma Cell Instruments oferuje dostosowane do indywidualnych potrzeb rozwi\u0105zania automatyzacyjne dla laboratori\u00f3w zajmuj\u0105cych si\u0119 badaniem strzykawek, w tym systemy wielostanowiskowe, oprogramowanie do zarz\u0105dzania danymi oraz zintegrowane platformy kontroli jako\u015bci.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b08dc9a elementor-widget elementor-widget-heading\" data-id=\"b08dc9a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Najcz\u0119\u015bciej zadawane pytania<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e8bf18 elementor-widget elementor-widget-text-editor\" data-id=\"3e8bf18\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>Czym jest norma ISO 8537?<\/strong><br \/>ISO 8537 to mi\u0119dzynarodowa norma okre\u015blaj\u0105ca wymagania i metody bada\u0144 dotycz\u0105ce sterylnych strzykawek do insuliny jednorazowego u\u017cytku, zar\u00f3wno z ig\u0142ami, jak i bez igie\u0142.<\/p><p><strong>Czym jest badanie szczelno\u015bci strzykawek zgodnie z norm\u0105 ISO 8537?<\/strong><br \/>Badanie szczelno\u015bci strzykawek polega na ocenie wyciek\u00f3w powietrza lub cieczy przez uszczelnienia t\u0142oka, dysze strzykawek oraz po\u0142\u0105czenia igie\u0142 w warunkach pr\u00f3\u017cni lub pod ci\u015bnieniem.<\/p><p><strong>Dlaczego badanie si\u0142y przesuwu strzykawki jest wa\u017cne?<\/strong><br \/>Badanie si\u0142y przesuwu pozwala sprawdzi\u0107, czy t\u0142ok porusza si\u0119 p\u0142ynnie i r\u00f3wnomiernie, co gwarantuje precyzyjne podawanie insuliny oraz prawid\u0142owe dzia\u0142anie strzykawki.<\/p><p><strong>Czym jest test szczelno\u015bci uszczelnienia strzykawki?<\/strong><br \/>Test szczelno\u015bci uszczelnienia strzykawki pozwala ustali\u0107, czy powierzchnie styku zapewniaj\u0105 szczelno\u015b\u0107 w warunkach kompresji i zasysania.<\/p><p><strong>W jaki spos\u00f3b przeprowadza si\u0119 pomiar przestrzeni martwej?<\/strong><br \/>Pomiar martwej przestrzeni opiera si\u0119 na metodzie grawimetrycznej, polegaj\u0105cej na por\u00f3wnaniu masy strzykawki przed i po usuni\u0119ciu wody w celu okre\u015blenia obj\u0119to\u015bci pozosta\u0142ego p\u0142ynu.<\/p><p><strong>Do czego s\u0142u\u017c\u0105 te instrumenty? <a href=\"https:\/\/www.iso.org\/standard\/60510.html\" target=\"_blank\" rel=\"noopener\">ISO 8537<\/a> testowanie?<\/strong><br \/>Do typowych przyrz\u0105d\u00f3w nale\u017c\u0105 pr\u00f3\u017cniowe testery szczelno\u015bci, uniwersalne maszyny do bada\u0144, systemy do pomiaru spadku ci\u015bnienia oraz urz\u0105dzenia do pomiar\u00f3w grawimetrycznych.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 8537 \u2013 Badanie funkcjonalno\u015bci strzykawek insulinowych Norma ISO 8537 okre\u015bla wymagania dotycz\u0105ce w\u0142a\u015bciwo\u015bci u\u017cytkowych i bada\u0144 sterylnych strzykawek insulinowych jednorazowego u\u017cytku, z ig\u0142ami lub bez. Norma ta koncentruje si\u0119 na bezpiecze\u0144stwie strzykawek, ich funkcjonalno\u015bci, szczelno\u015bci, dok\u0142adno\u015bci dawkowania oraz niezawodno\u015bci dzia\u0142ania. Producenci i laboratoria kontroli jako\u015bci stosuj\u0105 norm\u0119 ISO 8537 w celu weryfikacji, czy strzykawki dzia\u0142aj\u0105 sp\u00f3jnie podczas stosowania klinicznego. [\u2026]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2610","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/pl\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 8537 Syringe Functionality Testing for Insulin Syringe ISO 8537 specifies the performance and testing requirements for sterile single-use insulin syringes, with or without needles. The standard focuses on syringe safety, functionality, sealing performance, dosage accuracy, and operational reliability. Manufacturers and quality laboratories use ISO 8537 to verify that syringes perform consistently during clinical use.&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/2610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/comments?post=2610"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/2610\/revisions"}],"predecessor-version":[{"id":2624,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/2610\/revisions\/2624"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/media?parent=2610"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/categories?post=2610"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/tags?post=2610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}