{"id":2225,"date":"2025-07-17T03:26:50","date_gmt":"2025-07-17T03:26:50","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2225"},"modified":"2025-07-17T03:32:17","modified_gmt":"2025-07-17T03:32:17","slug":"break-loose-and-glide-force-testing","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/pl\/break-loose-and-glide-force-testing\/","title":{"rendered":"Testy si\u0142y zrywaj\u0105cej i \u015blizgowej dla papieru: ISO 7886 i ocena strzykawki"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2225\" class=\"elementor elementor-2225\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9145dad e-flex e-con-boxed e-con e-parent\" data-id=\"9145dad\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a89c638 elementor-widget elementor-widget-heading\" data-id=\"a89c638\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testy si\u0142y luzu i po\u015blizgu: Kluczowy wska\u017anik wydajno\u015bci strzykawki<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b6a1371 e-flex e-con-boxed e-con e-parent\" data-id=\"b6a1371\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-693eb6e elementor-widget elementor-widget-text-editor\" data-id=\"693eb6e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"538\" data-end=\"945\">W bran\u017cy farmaceutycznej i urz\u0105dze\u0144 medycznych, <strong data-start=\"591\" data-end=\"630\">Testowanie luzu i si\u0142y po\u015blizgu<\/strong> to krytyczna procedura stosowana do oceny u\u017cyteczno\u015bci i jako\u015bci strzykawek. Testy te okre\u015blaj\u0105, jaka si\u0142a jest wymagana do rozpocz\u0119cia (poluzowania) i kontynuowania (po\u015blizgu) ruchu t\u0142oka w cylindrze strzykawki. Wyniki maj\u0105 bezpo\u015bredni wp\u0142yw na zgodno\u015b\u0107 produktu, komfort iniekcji i bezpiecze\u0144stwo pacjenta.<\/p><p data-start=\"947\" data-end=\"1391\">Ta metoda testowania jest szczeg\u00f3lnie istotna dla producent\u00f3w opracowuj\u0105cych <strong data-start=\"1016\" data-end=\"1091\">ampu\u0142kostrzykawki, sterylne podzespo\u0142y i elementy automatycznych wstrzykiwaczy<\/strong>. Zbyt ciasny lub lu\u017any t\u0142ok mo\u017ce prowadzi\u0107 do b\u0142\u0119d\u00f3w dozowania, od\u0142\u0105czenia t\u0142oka lub niesp\u00f3jnego przep\u0142ywu leku - wszystko to stanowi zagro\u017cenie dla bezpiecze\u0144stwa. Z tego powodu proces testowania jest jasno opisany w wielu mi\u0119dzynarodowych standardach, w tym <strong data-start=\"1341\" data-end=\"1355\">ISO 7886-1<\/strong>, <strong data-start=\"1357\" data-end=\"1372\">ISO 11040-4<\/strong>oraz <strong data-start=\"1378\" data-end=\"1390\">ISO 8537<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ee73ce6 e-flex e-con-boxed e-con e-parent\" data-id=\"ee73ce6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7316cbe elementor-widget elementor-widget-heading\" data-id=\"7316cbe\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testowanie si\u0142y po\u015blizgu strzykawki i mi\u0119dzynarodowe standardy zgodno\u015bci<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4fe64ba e-flex e-con-boxed e-con e-parent\" data-id=\"4fe64ba\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-697f2ea elementor-widget elementor-widget-text-editor\" data-id=\"697f2ea\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1470\" data-end=\"1745\">Organy regulacyjne ustanowi\u0142y surowe wymagania, aby zapewni\u0107 niezawodne i powtarzalne dzia\u0142anie strzykawki. <strong data-start=\"1585\" data-end=\"1616\">Testowanie si\u0142y po\u015blizgu strzykawki<\/strong> ocenia zachowanie tarcia w okre\u015blonych warunkach w celu wykrycia zmian w smarowaniu lub w\u0142a\u015bciwo\u015bciach materia\u0142u.<\/p><p data-start=\"1747\" data-end=\"2087\"><strong data-start=\"1747\" data-end=\"1761\">ISO 7886-1<\/strong><br data-start=\"1761\" data-end=\"1764\" \/>Niniejszy standard ma zastosowanie do <strong data-start=\"1789\" data-end=\"1820\">sterylne strzykawki jednorazowego u\u017cytku<\/strong>. Definiuje metody pomiaru si\u0142y zar\u00f3wno dla warto\u015bci zerwania, jak i po\u015blizgu, kt\u00f3re musz\u0105 pozosta\u0107 w ustalonych zakresach, aby zagwarantowa\u0107 p\u0142ynne dzia\u0142anie. Zazwyczaj stosowana pr\u0119dko\u015b\u0107 testowa to <strong data-start=\"2010\" data-end=\"2024\">100 mm\/min<\/strong>i zalecane jest pozyskiwanie danych z wysok\u0105 cz\u0119stotliwo\u015bci\u0105 (\u2265500 Hz).<\/p><p data-start=\"2089\" data-end=\"2451\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"2089\" data-end=\"2104\">ISO 11040-4<\/strong><\/a><br data-start=\"2104\" data-end=\"2107\" \/>Koncentruje si\u0119 na <strong data-start=\"2118\" data-end=\"2158\">szklane beczki na ampu\u0142kostrzykawki<\/strong>Standard ten obejmuje <strong data-start=\"2183\" data-end=\"2194\">Za\u0142\u0105cznik E<\/strong>kt\u00f3ry okre\u015bla metod\u0119 testowania si\u0142y po\u015blizgu dla sterylnych podzespo\u0142\u00f3w. Okre\u015bla ona wymagania dotycz\u0105ce <strong data-start=\"2300\" data-end=\"2366\">Zatyczka t\u0142oka, wn\u0119trze cylindra i smarowanie olejem silikonowym<\/strong>. Sta\u0142e niskie tarcie jest niezb\u0119dne do spe\u0142nienia kryteri\u00f3w okre\u015blonych w tym standardzie.<\/p><p data-start=\"2453\" data-end=\"2717\"><strong data-start=\"2453\" data-end=\"2465\">ISO 8537<\/strong><br data-start=\"2465\" data-end=\"2468\" \/>Zaprojektowany dla <strong data-start=\"2481\" data-end=\"2501\">strzykawki insulinowe<\/strong>Norma ta k\u0142adzie nacisk na dok\u0142adne podawanie dawki poprzez kontrol\u0119 ruchu t\u0142oka. Odporno\u015b\u0107 na po\u015blizg jest szczeg\u00f3lnie istotna w urz\u0105dzeniach do podawania insuliny, gdzie sta\u0142a szybko\u015b\u0107 wstrzykiwania zapewnia bezpieczne zarz\u0105dzanie glukoz\u0105.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f96e75b e-flex e-con-boxed e-con e-parent\" data-id=\"f96e75b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab96e67 elementor-widget elementor-widget-heading\" data-id=\"ab96e67\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedury testowe i parametry<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e898377 e-flex e-con-boxed e-con e-parent\" data-id=\"e898377\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6c4a14 elementor-widget elementor-widget-text-editor\" data-id=\"e6c4a14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2760\" data-end=\"2842\">Procedura testowania si\u0142y zrywaj\u0105cej i \u015blizgowej przebiega zgodnie z ustrukturyzowanym formatem:<\/p><ol data-start=\"2844\" data-end=\"3739\"><li data-start=\"2844\" data-end=\"2990\"><p data-start=\"2847\" data-end=\"2990\"><strong data-start=\"2847\" data-end=\"2862\">Przygotowanie<\/strong><br data-start=\"2862\" data-end=\"2865\" \/>U\u017cycie <strong data-start=\"2872\" data-end=\"2901\">wysterylizowane puste strzykawki<\/strong> gotowy do nape\u0142nienia. Zainstalowa\u0107 kompatybilny ogranicznik t\u0142oka z okre\u015blonymi poziomami smarowania.<\/p><\/li><li data-start=\"2992\" data-end=\"3220\"><p data-start=\"2995\" data-end=\"3220\"><strong data-start=\"2995\" data-end=\"3004\">Konfiguracja<\/strong><br data-start=\"3004\" data-end=\"3007\" \/>Umie\u015bci\u0107 strzykawk\u0119 w uniwersalnej maszynie testuj\u0105cej lub dedykowanym urz\u0105dzeniu, takim jak <strong data-start=\"3094\" data-end=\"3155\">Tester rezystancji przesuwnej strzykawki Cell Instruments SSR-01<\/strong>. Przymocuj go za pomoc\u0105 odpowiedniego wyr\u00f3wnania uchwytu, aby zapewni\u0107 ruch osiowy.<\/p><\/li><li data-start=\"3222\" data-end=\"3419\"><p data-start=\"3225\" data-end=\"3419\"><strong data-start=\"3225\" data-end=\"3238\">Wykonanie<\/strong><br data-start=\"3238\" data-end=\"3241\" \/>Zainicjowa\u0107 ruch t\u0142oka z pr\u0119dko\u015bci\u0105 100 mm\/min. Urz\u0105dzenie testuj\u0105ce rejestruje <strong data-start=\"3319\" data-end=\"3355\">si\u0142a zrywaj\u0105ca (pocz\u0105tkowa warto\u015b\u0107 szczytowa)<\/strong> i <strong data-start=\"3364\" data-end=\"3418\">si\u0142a po\u015blizgu (\u015brednia si\u0142a podczas ci\u0105g\u0142ego ruchu)<\/strong>.<\/p><\/li><li data-start=\"3421\" data-end=\"3597\"><p data-start=\"3424\" data-end=\"3472\"><strong data-start=\"3424\" data-end=\"3440\">Przechwytywanie danych<\/strong><br data-start=\"3440\" data-end=\"3443\" \/>Rejestrowanie kluczowych danych, w tym:<\/p><ul data-start=\"3476\" data-end=\"3597\"><li data-start=\"3476\" data-end=\"3500\"><p data-start=\"3478\" data-end=\"3500\">Si\u0142a zrywaj\u0105ca (f\u2080)<\/p><\/li><li data-start=\"3504\" data-end=\"3526\"><p data-start=\"3506\" data-end=\"3526\">\u015arednia si\u0142a po\u015blizgu (F)<\/p><\/li><li data-start=\"3530\" data-end=\"3558\"><p data-start=\"3532\" data-end=\"3558\">Maksymalna si\u0142a po\u015blizgu (F\u2098\u2090\u2093)<\/p><\/li><li data-start=\"3562\" data-end=\"3597\"><p data-start=\"3564\" data-end=\"3597\">Odleg\u0142o\u015b\u0107 podr\u00f3\u017cy i czas trwania testu<\/p><\/li><\/ul><\/li><li data-start=\"3599\" data-end=\"3739\"><p data-start=\"3602\" data-end=\"3739\"><strong data-start=\"3602\" data-end=\"3616\">Ocena<\/strong><br data-start=\"3616\" data-end=\"3619\" \/>Wyniki s\u0105 por\u00f3wnywane z limitami specyfikacji ISO 7886-1, ISO 11040-4 lub ISO 8537, w zale\u017cno\u015bci od typu strzykawki.<\/p><\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94fd533 e-flex e-con-boxed e-con e-parent\" data-id=\"94fd533\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f724e30 elementor-widget elementor-widget-heading\" data-id=\"f724e30\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Typowe problemy wykryte podczas test\u00f3w si\u0142y po\u015blizgu<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-422d4c4 e-flex e-con-boxed e-con e-parent\" data-id=\"422d4c4\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbff8ed elementor-widget elementor-widget-text-editor\" data-id=\"dbff8ed\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3802\" data-end=\"3888\">Testy luzu i si\u0142y po\u015blizgu ujawniaj\u0105 krytyczne problemy zwi\u0105zane z jako\u015bci\u0105 strzykawek, takie jak<\/p><ul data-start=\"3890\" data-end=\"4134\"><li data-start=\"3890\" data-end=\"3961\"><p data-start=\"3892\" data-end=\"3961\"><strong data-start=\"3892\" data-end=\"3914\">Nadmierne tarcie<\/strong> z niewystarczaj\u0105cej lub nier\u00f3wnej pow\u0142oki silikonowej<\/p><\/li><li data-start=\"3962\" data-end=\"4012\"><p data-start=\"3964\" data-end=\"4012\"><strong data-start=\"3964\" data-end=\"3985\">Zacinaj\u0105ce si\u0119 t\u0142oki<\/strong>wp\u0142ywaj\u0105ce na dok\u0142adno\u015b\u0107 dawki<\/p><\/li><li data-start=\"4013\" data-end=\"4072\"><p data-start=\"4015\" data-end=\"4072\"><strong data-start=\"4015\" data-end=\"4043\">Niezgodno\u015b\u0107 materia\u0142owa<\/strong> mi\u0119dzy luf\u0105 a t\u0142okiem<\/p><\/li><li data-start=\"4073\" data-end=\"4134\"><p data-start=\"4075\" data-end=\"4134\"><strong data-start=\"4075\" data-end=\"4100\">Od\u0142\u0105czenie t\u0142oka<\/strong> lub wyciek uszczelnienia pod wp\u0142ywem si\u0142y osiowej<\/p><\/li><\/ul><p data-start=\"4136\" data-end=\"4237\">Zidentyfikowanie tych problem\u00f3w na etapie bada\u0144 i rozwoju lub produkcji chroni dalsze procesy i wyniki pacjent\u00f3w.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-358cd95 e-flex e-con-boxed e-con e-parent\" data-id=\"358cd95\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1be87be elementor-widget elementor-widget-heading\" data-id=\"1be87be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Zalecany sprz\u0119t: Cell Instruments SSR-01 Tester rezystancji przesuwnej strzykawki<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-97d0577 e-flex e-con-boxed e-con e-parent\" data-id=\"97d0577\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4f6c718 e-con-full e-flex e-con e-child\" data-id=\"4f6c718\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-495d6e6 elementor-widget elementor-widget-text-editor\" data-id=\"495d6e6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4330\" data-end=\"4474\">Aby wykona\u0107 te testy dok\u0142adnie i zgodnie z normami ISO, Cell Instruments oferuje<a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/syringes-plunger-glide-force-tester\/\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"4430\" data-end=\"4440\">SSR-01<\/strong><\/a>. Ten instrument jest przeznaczony do:<\/p><ul data-start=\"4476\" data-end=\"4766\"><li data-start=\"4476\" data-end=\"4534\"><p data-start=\"4478\" data-end=\"4534\"><strong data-start=\"4478\" data-end=\"4501\">Precyzyjny pomiar<\/strong> zerwania i si\u0142y po\u015blizgu<\/p><\/li><li data-start=\"4535\" data-end=\"4596\"><p data-start=\"4537\" data-end=\"4596\"><strong data-start=\"4537\" data-end=\"4563\">Regulowane pr\u0119dko\u015bci testu<\/strong> i programowalne ustawienia testowe<\/p><\/li><li data-start=\"4597\" data-end=\"4657\"><p data-start=\"4599\" data-end=\"4657\"><strong data-start=\"4599\" data-end=\"4625\">Wy\u015bwietlanie danych w czasie rzeczywistym<\/strong> za po\u015brednictwem 7-calowego ekranu dotykowego HMI<\/p><\/li><li data-start=\"4658\" data-end=\"4712\"><p data-start=\"4660\" data-end=\"4712\"><strong data-start=\"4660\" data-end=\"4686\">Wbudowana mikrodrukarka<\/strong> do natychmiastowego zg\u0142oszenia<\/p><\/li><li data-start=\"4713\" data-end=\"4766\"><p data-start=\"4715\" data-end=\"4766\"><strong data-start=\"4715\" data-end=\"4736\">Elastyczny osprz\u0119t<\/strong> dla r\u00f3\u017cnych format\u00f3w strzykawek<\/p><\/li><\/ul><p data-start=\"4768\" data-end=\"4893\">Jego intuicyjny interfejs i solidna wydajno\u015b\u0107 sprawiaj\u0105, \u017ce jest idealny zar\u00f3wno dla <strong data-start=\"4838\" data-end=\"4859\">zapewnienie jako\u015bci<\/strong> oraz <strong data-start=\"4864\" data-end=\"4892\">laboratoria rozwoju produkt\u00f3w<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7285d35 e-con-full e-flex e-con e-child\" data-id=\"7285d35\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f5e0678 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"f5e0678\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp\" class=\"attachment-medium_large size-medium_large wp-image-2227\" alt=\"Maszyna do testowania si\u0142y zrywania i po\u015blizgu - wszechstronne, precyzyjne rozwi\u0105zanie dostosowane do testowania strzykawek i materia\u0142\u00f3w opakowaniowych.\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-1024x1024.webp 1024w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1.webp 1080w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d9ef370 e-flex e-con-boxed e-con e-parent\" data-id=\"d9ef370\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-354bdaf elementor-widget elementor-widget-heading\" data-id=\"354bdaf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dlaczego to badanie ma znaczenie dla producent\u00f3w<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9e66002 e-flex e-con-boxed e-con e-parent\" data-id=\"9e66002\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-aae1c87 e-con-full e-flex e-con e-child\" data-id=\"aae1c87\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf49733 elementor-widget elementor-widget-video\" data-id=\"bf49733\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=Jv55XhLaURk&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;modestbranding&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2cf2943 e-con-full e-flex e-con e-child\" data-id=\"2cf2943\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c0dc11 elementor-widget elementor-widget-text-editor\" data-id=\"0c0dc11\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"4948\" data-end=\"5007\"><p data-start=\"4950\" data-end=\"5007\"><strong data-start=\"4950\" data-end=\"4981\">Obs\u0142uguje zg\u0142oszenia regulacyjne<\/strong> z danymi zgodnymi z ISO<\/p><\/li><li data-start=\"5008\" data-end=\"5082\"><p data-start=\"5010\" data-end=\"5082\"><strong data-start=\"5010\" data-end=\"5040\">Poprawia u\u017cyteczno\u015b\u0107 produktu<\/strong> eliminuj\u0105c zacinanie si\u0119 lub nieregularny przep\u0142yw<\/p><\/li><li data-start=\"5083\" data-end=\"5144\"><p data-start=\"5085\" data-end=\"5144\"><strong data-start=\"5085\" data-end=\"5115\">Zwi\u0119ksza jednorodno\u015b\u0107 partii<\/strong> do produkcji wielkoseryjnej<\/p><\/li><li data-start=\"5145\" data-end=\"5201\"><p data-start=\"5147\" data-end=\"5201\"><strong data-start=\"5147\" data-end=\"5173\">Zmniejsza ryzyko wycofania produktu<\/strong> z powodu awarii mechanicznej<\/p><\/li><li data-start=\"5202\" data-end=\"5283\"><p data-start=\"5204\" data-end=\"5283\"><strong data-start=\"5204\" data-end=\"5232\">Zwi\u0119ksza komfort pacjenta<\/strong>szczeg\u00f3lnie w przypadku wstrzykiwaczy automatycznych i strzykawek insulinowych<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0c0191b e-flex e-con-boxed e-con e-parent\" data-id=\"0c0191b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4180a60 elementor-widget elementor-widget-heading\" data-id=\"4180a60\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wnioski<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fa9b8b6 e-flex e-con-boxed e-con e-parent\" data-id=\"fa9b8b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-28ecdb2 elementor-widget elementor-widget-text-editor\" data-id=\"28ecdb2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5306\" data-end=\"5729\"><strong data-start=\"5306\" data-end=\"5345\">Testowanie luzu i si\u0142y po\u015blizgu<\/strong> jest podstawow\u0105 cz\u0119\u015bci\u0105 oceny jako\u015bci strzykawek. Przestrzeganie <a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5411\" data-end=\"5425\">ISO 7886-1<\/strong><\/a>, <strong data-start=\"5427\" data-end=\"5442\">ISO 11040-4<\/strong>oraz <strong data-start=\"5448\" data-end=\"5460\">ISO 8537<\/strong> zapewnia niezawodno\u015b\u0107 produktu, zgodno\u015b\u0107 z przepisami i bezpieczne dostarczanie lek\u00f3w. Inwestuj\u0105c w zaawansowane instrumenty, takie jak <strong data-start=\"5583\" data-end=\"5615\">SSR-01 od<a href=\"https:\/\/www.celtec.cn\" target=\"_blank\" rel=\"noopener\"> Cell Instruments<\/a><\/strong>Dzi\u0119ki temu producenci mog\u0105 bez obaw dostarcza\u0107 strzykawki o wysokiej wydajno\u015bci, kt\u00f3re spe\u0142niaj\u0105 oczekiwania zar\u00f3wno bran\u017cy, jak i pacjent\u00f3w.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Break Loose and Glide Force Testing: A Key Indicator of Syringe Performance In the pharmaceutical and medical device industries, break loose and glide force testing is a critical procedure used to evaluate the usability and quality of syringes. These tests determine how much force is required to start (break loose) and continue (glide) the movement [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2225","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/pl\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Break Loose and Glide Force Testing: A Key Indicator of Syringe Performance In the pharmaceutical and medical device industries, break loose and glide force testing is a critical procedure used to evaluate the usability and quality of syringes. These tests determine how much force is required to start (break loose) and continue (glide) the movement&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/2225","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/comments?post=2225"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/2225\/revisions"}],"predecessor-version":[{"id":2251,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/2225\/revisions\/2251"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/media?parent=2225"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/categories?post=2225"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/tags?post=2225"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}