{"id":2036,"date":"2025-04-14T09:07:36","date_gmt":"2025-04-14T09:07:36","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2036"},"modified":"2025-04-22T03:29:56","modified_gmt":"2025-04-22T03:29:56","slug":"syringe-leakage-testing-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/pl\/syringe-leakage-testing-iso-11040-4\/","title":{"rendered":"Test szczelno\u015bci strzykawki - ISO 11040-4, za\u0142\u0105cznik G2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2036\" class=\"elementor elementor-2036\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b47b928 e-flex e-con-boxed e-con e-parent\" data-id=\"b47b928\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e8261b4 elementor-widget elementor-widget-heading\" data-id=\"e8261b4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Test szczelno\u015bci strzykawki<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6fa5bf elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"a6fa5bf\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03e5049 elementor-widget elementor-widget-heading\" data-id=\"03e5049\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Za\u0142\u0105cznik G2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2170a2 e-flex e-con-boxed e-con e-parent\" data-id=\"b2170a2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec36001 elementor-widget elementor-widget-text-editor\" data-id=\"ec36001\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"375\" data-end=\"1050\">W dziedzinie produkcji farmaceutyk\u00f3w i urz\u0105dze\u0144 medycznych, <em data-start=\"459\" data-end=\"484\">Testowanie szczelno\u015bci strzykawki<\/em> jest krytycznym procesem zapewniania jako\u015bci. Zapewnia on, \u017ce <strong data-start=\"542\" data-end=\"564\">ampu\u0142kostrzykawki<\/strong> zachowuj\u0105 sterylno\u015b\u0107 i nie przeciekaj\u0105 podczas transportu, przechowywania lub u\u017cytkowania. Aby spe\u0142ni\u0107 rygorystyczne oczekiwania regulacyjne, producenci musz\u0105 przestrzega\u0107 mi\u0119dzynarodowych standard\u00f3w, takich jak <strong data-start=\"736\" data-end=\"751\">ISO 11040-4<\/strong>w szczeg\u00f3lno\u015bci <strong data-start=\"764\" data-end=\"776\">Za\u0142\u0105cznik G2<\/strong>kt\u00f3ry przedstawia <strong data-start=\"797\" data-end=\"830\">metoda badania wycieku cieczy<\/strong> do system\u00f3w zamykania strzykawek.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ebf1ff6 elementor-widget elementor-widget-heading\" data-id=\"ebf1ff6\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Czym jest test szczelno\u015bci strzykawki?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f9a4f4 elementor-widget elementor-widget-text-editor\" data-id=\"1f9a4f4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1115\" data-end=\"1487\">Testy szczelno\u015bci strzykawki oceniaj\u0105, czy system zamykania strzykawki - albo <strong data-start=\"1232\" data-end=\"1249\">os\u0142ona ig\u0142y<\/strong> lub <strong data-start=\"1253\" data-end=\"1264\">za\u015blepka<\/strong>-mo\u017ce wytrzyma\u0107 ci\u015bnienie wewn\u0119trzne, nie pozwalaj\u0105c na ucieczk\u0119 p\u0142ynu. Wed\u0142ug <strong data-start=\"1344\" data-end=\"1368\">ISO 11040-4 Za\u0142\u0105cznik G2<\/strong>Standardowe ci\u015bnienie testowe wynosi <strong data-start=\"1400\" data-end=\"1411\">110 kPa<\/strong>symuluj\u0105c rzeczywiste warunki podczas nape\u0142niania lub transportu strzykawki.<\/p><h3 data-start=\"1489\" data-end=\"1718\">Dlaczego to ma znaczenie<\/h3><p class=\"\" data-start=\"1489\" data-end=\"1718\">Wyciek nie tylko zagra\u017ca sterylno\u015bci produktu, ale mo\u017ce r\u00f3wnie\u017c powodowa\u0107 niedok\u0142adno\u015bci dawkowania i zagro\u017cenia dla bezpiecze\u0144stwa. Po <strong data-start=\"1626\" data-end=\"1657\">znormalizowana procedura testowa<\/strong> zapewnia sp\u00f3jno\u015b\u0107, niezawodno\u015b\u0107 i zgodno\u015b\u0107 z przepisami.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d11a485 elementor-widget elementor-widget-heading\" data-id=\"d11a485\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span style=\"font-size: 2.82353rem;\">ISO 11040-4 Za\u0142\u0105cznik G2 <\/span>Wymagania testowe<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-036bd3c e-con-full e-flex e-con e-child\" data-id=\"036bd3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7d2acf2 e-con-full e-flex e-con e-child\" data-id=\"7d2acf2\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8616b8 e-con-full e-flex e-con e-child\" data-id=\"f8616b8\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3773a30 elementor-widget elementor-widget-heading\" data-id=\"3773a30\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pr\u00f3bka do testowania szczelno\u015bci strzykawki<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f461568 elementor-widget elementor-widget-text-editor\" data-id=\"f461568\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Nale\u017cy u\u017cywa\u0107 wy\u0142\u0105cznie odczynnik\u00f3w klasy analitycznej i sterylnych, gotowych do nape\u0142nienia podzespo\u0142\u00f3w strzykawek. Pr\u00f3bki musz\u0105 pozosta\u0107 nietkni\u0119te przez <strong data-start=\"1927\" data-end=\"1948\">co najmniej 12 godzin<\/strong> po ustawieniu zamkni\u0119cia przed rozpocz\u0119ciem testu. Ten czas retencji zapewnia stabilizacj\u0119 zamkni\u0119cia.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-551a42f elementor-widget elementor-widget-heading\" data-id=\"551a42f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tester szczelno\u015bci strzykawki<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9fd1b0f elementor-widget elementor-widget-text-editor\" data-id=\"9fd1b0f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2046\" data-end=\"2117\">Za\u0142\u0105cznik G2 okre\u015bla dwie g\u0142\u00f3wne metody testowania:<\/p><ul><li data-start=\"2120\" data-end=\"2211\"><strong data-start=\"2120\" data-end=\"2149\">Mechaniczne zwi\u0119kszanie ci\u015bnienia<\/strong> przy u\u017cyciu <strong data-start=\"2158\" data-end=\"2211\">uniwersalna maszyna do pr\u00f3b rozci\u0105gania i \u015bciskania<\/strong><\/li><li data-start=\"2120\" data-end=\"2211\"><strong style=\"font-size: 16px;\" data-start=\"2214\" data-end=\"2253\">Ci\u015bnienie oparte na spr\u0119\u017conym powietrzu<\/strong><span style=\"font-size: 16px;\">preferowane tam, gdzie tarcie o \u015bcian\u0119 wp\u0142ywa na dok\u0142adno\u015b\u0107<\/span><\/li><\/ul><p class=\"\" data-start=\"2303\" data-end=\"2494\"><strong data-start=\"2303\" data-end=\"2354\">Tester strzykawek medycznych MST-01 firmy Cell Instruments<\/strong> oferuje kompleksowe rozwi\u0105zanie. Obs\u0142uguje zar\u00f3wno testy si\u0142owe, jak i ci\u015bnieniowe, idealne do zapewnienia zgodno\u015bci z normami ISO.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d3d2fd elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"8d3d2fd\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"Test szczelno\u015bci strzykawki ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d84a26e elementor-widget elementor-widget-heading\" data-id=\"d84a26e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Procedura testowania szczelno\u015bci strzykawki<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1a41478 e-grid e-con-full e-con e-child\" data-id=\"1a41478\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-51c8a4e elementor-widget elementor-widget-text-editor\" data-id=\"51c8a4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ol data-start=\"2526\" data-end=\"2787\"><li class=\"\" data-start=\"2526\" data-end=\"2603\"><p class=\"\" data-start=\"2529\" data-end=\"2603\">W\u0142o\u017cy\u0107 strzykawk\u0119 do <strong data-start=\"2555\" data-end=\"2573\">uchwyt strzykawki<\/strong> z zainstalowanym systemem zamykania.<\/p><\/li><li class=\"\" data-start=\"2604\" data-end=\"2665\"><p class=\"\" data-start=\"2607\" data-end=\"2665\">Nape\u0142ni\u0107 wod\u0105 destylowan\u0105 do 1\/3 do 2\/3 nominalnej obj\u0119to\u015bci.<\/p><\/li><li class=\"\" data-start=\"2666\" data-end=\"2706\"><p class=\"\" data-start=\"2669\" data-end=\"2706\">Zastosowa\u0107 ci\u015bnienie 110 kPa przez 5 sekund.<\/p><\/li><li class=\"\" data-start=\"2707\" data-end=\"2787\"><p class=\"\" data-start=\"2710\" data-end=\"2787\">Zwolnij ci\u015bnienie i <strong data-start=\"2731\" data-end=\"2764\">Kontrola pod k\u0105tem kropel zewn\u0119trznych<\/strong> lub od\u0142\u0105czenie nasadki.<\/p><\/li><\/ol><p class=\"\" data-start=\"2789\" data-end=\"2867\">Metoda ta odtwarza scenariusze nadci\u015bnienia i potwierdza integralno\u015b\u0107 uszczelnienia.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5676ace elementor-widget elementor-widget-video\" data-id=\"5676ace\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=XHOmBV4js_E&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2614162 e-flex e-con-boxed e-con e-parent\" data-id=\"2614162\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-72ac59a elementor-widget elementor-widget-heading\" data-id=\"72ac59a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Testowanie i interpretacja wynik\u00f3w<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70afec8 elementor-widget elementor-widget-text-editor\" data-id=\"70afec8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2904\" data-end=\"2921\">Aby zda\u0107 test:<\/p><ul><li data-start=\"2924\" data-end=\"3001\"><strong data-start=\"2924\" data-end=\"2946\">Brak kropelek cieczy<\/strong> powinna by\u0107 widoczna wok\u00f3\u0142 nasadki ko\u0144c\u00f3wki lub os\u0142ony ig\u0142y.<\/li><li data-start=\"2924\" data-end=\"3001\"><span style=\"font-size: 16px;\">Zamkni\u0119cie musi <\/span><strong style=\"font-size: 16px;\" data-start=\"3021\" data-end=\"3040\">pozosta\u0107 na miejscu<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3004\" data-end=\"3041\"><span style=\"font-size: 16px;\">Kontrola wzrokowa potwierdza, czy strzykawka przesz\u0142a pomy\u015blnie, czy nie.<\/span><\/li><\/ul><p class=\"\" data-start=\"3103\" data-end=\"3134\">Raport z testu powinien zawiera\u0107:<\/p><ul><li data-start=\"3137\" data-end=\"3162\">Zastosowany nacisk lub si\u0142a<\/li><li data-start=\"3137\" data-end=\"3162\">Liczba przetestowanych pr\u00f3bek<\/li><li data-start=\"3137\" data-end=\"3162\">Liczba zaliczonych lub niezaliczonych<\/li><li data-start=\"3137\" data-end=\"3162\">Wszelkie odchylenia zaobserwowane podczas testu<\/li><\/ul><p class=\"\" data-start=\"3259\" data-end=\"3336\">W\u0142a\u015bciwa dokumentacja ma zasadnicze znaczenie dla audyt\u00f3w regulacyjnych i \u015bledzenia jako\u015bci.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-87c6b33 elementor-widget elementor-widget-heading\" data-id=\"87c6b33\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tester szczelno\u015bci ampu\u0142kostrzykawek<small>--Wi\u0119cej aplikacji<\/small><\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd20d14 elementor-widget elementor-widget-text-editor\" data-id=\"cd20d14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3408\" data-end=\"3534\"><strong data-start=\"3408\" data-end=\"3435\">Testowanie szczelno\u015bci strzykawki<\/strong> jest tylko jednym z aspekt\u00f3w <strong data-start=\"3458\" data-end=\"3487\">Testowanie ampu\u0142kostrzykawek<\/strong> pod <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a>. Producenci badaj\u0105 r\u00f3wnie\u017c:<\/p><ul><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"3537\" data-end=\"3567\">Op\u00f3r \u015blizgowy t\u0142oka<\/strong><\/a><\/li><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/syringes-needle-penetration-test-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-size: 16px;\" data-start=\"3570\" data-end=\"3598\">Si\u0142a penetracji ig\u0142y<\/strong><\/a><\/li><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/needle-bonding-strength-test-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-size: 16px;\" data-start=\"3601\" data-end=\"3641\">Si\u0142a wi\u0105zania mi\u0119dzy ig\u0142\u0105 a piast\u0105<\/strong><\/a><\/li><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-size: 16px;\" data-start=\"3644\" data-end=\"3676\">Zatrzymanie t\u0142oka (wysuwanie)<\/strong><\/a><\/li><\/ul><p class=\"\" data-start=\"3678\" data-end=\"3926\"><strong data-start=\"3678\" data-end=\"3688\">MST-01<\/strong> integruje te funkcje w jednej, kompaktowej jednostce testuj\u0105cej. Umo\u017cliwia pe\u0142n\u0105 weryfikacj\u0119 mechaniczn\u0105 <strong data-start=\"3796\" data-end=\"3833\">puste sterylne strzykawki jednorazowego u\u017cytku<\/strong>, zgodne nie tylko z norm\u0105 ISO 11040-4, ale tak\u017ce <a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"3880\" data-end=\"3894\">ISO 7886-1<\/strong><\/a>, <strong data-start=\"3896\" data-end=\"3908\">ISO 8537<\/strong>oraz <strong data-start=\"3914\" data-end=\"3925\">USP 382<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1288b5d elementor-widget elementor-widget-heading\" data-id=\"1288b5d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dlaczego warto wybra\u0107 MST-01 do testowania szczelno\u015bci strzykawki?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-601b24a elementor-widget elementor-widget-text-editor\" data-id=\"601b24a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4001\" data-end=\"4057\">The <strong data-start=\"4005\" data-end=\"4038\">Tester strzykawek medycznych MST-01<\/strong> wyr\u00f3\u017cnia si\u0119 dzi\u0119ki:<\/p><ul><li data-start=\"4060\" data-end=\"4110\"><strong data-start=\"4060\" data-end=\"4085\">Mo\u017cliwo\u015b\u0107 przeprowadzania wielu test\u00f3w<\/strong> wbudowane w jedn\u0105 platform\u0119<\/li><li data-start=\"4060\" data-end=\"4110\"><strong style=\"font-size: 16px;\" data-start=\"4113\" data-end=\"4138\">System sterowany przez PLC<\/strong><span style=\"font-size: 16px;\"> i 7-calowy ekran dotykowy<\/span><\/li><li data-start=\"4060\" data-end=\"4110\"><strong style=\"font-size: 16px;\" data-start=\"4164\" data-end=\"4209\">Precyzyjne sterowanie si\u0142\u0105 i przemieszczeniem<\/strong><\/li><li data-start=\"4060\" data-end=\"4110\"><strong style=\"font-size: 16px;\" data-start=\"4212\" data-end=\"4236\">Monitorowanie w czasie rzeczywistym<\/strong><span style=\"font-size: 16px;\"> i wbudowana mikrodrukarka<\/span><\/li><\/ul><p class=\"\" data-start=\"4264\" data-end=\"4549\">Ta wszechstronno\u015b\u0107 zapewnia dok\u0142adne, wydajne i powtarzalne testy szczelno\u015bci strzykawek przy jednoczesnym spe\u0142nieniu globalnych standard\u00f3w. Dzi\u0119ki konfigurowalnym uchwytom i programowalnym konfiguracjom testowym, MST-01 zapewnia <strong data-start=\"4458\" data-end=\"4476\">op\u0142acalny<\/strong> oraz <strong data-start=\"4481\" data-end=\"4498\">przyjazny dla u\u017cytkownika<\/strong> rozwi\u0105zanie dla farmaceutycznych zespo\u0142\u00f3w kontroli jako\u015bci.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Leakage Testing ISO 11040-4 Annex G2 In the field of pharmaceutical and medical device manufacturing, syringe leakage testing is a critical quality assurance process. It ensures that prefilled syringes maintain sterility and do not leak during transport, storage, or use. To meet stringent regulatory expectations, manufacturers must follow international standards such as ISO 11040-4, [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2036","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/pl\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Syringe Leakage Testing ISO 11040-4 Annex G2 In the field of pharmaceutical and medical device manufacturing, syringe leakage testing is a critical quality assurance process. It ensures that prefilled syringes maintain sterility and do not leak during transport, storage, or use. To meet stringent regulatory expectations, manufacturers must follow international standards such as ISO 11040-4,&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/2036","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/comments?post=2036"}],"version-history":[{"count":6,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/2036\/revisions"}],"predecessor-version":[{"id":2055,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/2036\/revisions\/2055"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/media?parent=2036"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/categories?post=2036"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/tags?post=2036"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}