{"id":1893,"date":"2025-01-24T05:40:31","date_gmt":"2025-01-24T05:40:31","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=1893"},"modified":"2025-04-02T06:30:55","modified_gmt":"2025-04-02T06:30:55","slug":"syringe-glide-force-testing-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/pl\/syringe-glide-force-testing-iso-11040-4\/","title":{"rendered":"Testowanie si\u0142y po\u015blizgu strzykawki | ISO 11040-4 Za\u0142\u0105cznik E"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"1893\" class=\"elementor elementor-1893\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c8f6b32 e-flex e-con-boxed e-con e-parent\" data-id=\"c8f6b32\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3871c01 elementor-widget elementor-widget-heading\" data-id=\"3871c01\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Testowanie si\u0142y po\u015blizgu strzykawki<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28eeae4 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"28eeae4\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c6f7aa elementor-widget elementor-widget-heading\" data-id=\"9c6f7aa\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Za\u0142\u0105cznik E<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-60074b4 e-flex e-con-boxed e-con e-parent\" data-id=\"60074b4\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-9e604be e-con-full e-flex e-con e-child\" data-id=\"9e604be\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-815caf1 elementor-widget elementor-widget-text-editor\" data-id=\"815caf1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>W bran\u017cy medycznej i farmaceutycznej zapewnienie wydajno\u015bci i jako\u015bci strzykawek ma kluczowe znaczenie. Jedn\u0105 z krytycznych metod oceny funkcjonalno\u015bci strzykawki jest <strong>Testowanie si\u0142y po\u015blizgu strzykawki ISO 11040-4<\/strong>. Norma ta pomaga producentom zapewni\u0107, \u017ce strzykawki, smarowane lub niesmarowane, dzia\u0142aj\u0105 sp\u00f3jnie i niezawodnie, gdy s\u0105 u\u017cywane do podawania lek\u00f3w.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf043c8 elementor-widget elementor-widget-heading\" data-id=\"bf043c8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Czym jest test si\u0142y po\u015blizgu strzykawki ISO 11040-4?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7514f4b elementor-widget elementor-widget-text-editor\" data-id=\"7514f4b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Norma ISO 11040-4 okre\u015bla procedur\u0119 pomiaru <strong>si\u0142a po\u015blizgu<\/strong> strzykawki, czyli si\u0142a wymagana do przesuni\u0119cia t\u0142oka w cylindrze. Test ten jest niezb\u0119dny do oceny jako\u015bci i sp\u00f3jno\u015bci strzykawek, zw\u0142aszcza gdy s\u0105 one u\u017cywane w zastosowaniach medycznych.<\/p><p>Cel tych test\u00f3w jest dwojaki:<\/p><ol><li><strong>Ocena smarowania<\/strong>: Pomaga okre\u015bli\u0107 skuteczno\u015b\u0107 smarowania wewn\u0105trz cylindra strzykawki, zwykle za pomoc\u0105 oleju silikonowego lub innych materia\u0142\u00f3w.<\/li><li><strong>Strzykawki niesmarowane<\/strong>: Test ocenia r\u00f3wnie\u017c niesmarowane strzykawki, w tym te wype\u0142nione wod\u0105 do wstrzykiwa\u0144, symuluj\u0105c rzeczywiste warunki u\u017cytkowania.<\/li><\/ol><p>Procedura ta zapewnia, \u017ce strzykawki spe\u0142niaj\u0105 okre\u015blone standardy si\u0142y po\u015blizgu, zmniejszaj\u0105c tarcie podczas wstrzykiwania i zapewniaj\u0105c bezpiecze\u0144stwo i komfort pacjenta.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91331e3 elementor-widget elementor-widget-heading\" data-id=\"91331e3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Znaczenie si\u0142y po\u015blizgu w strzykawkach<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61602c4 elementor-widget elementor-widget-text-editor\" data-id=\"61602c4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Test si\u0142y po\u015blizgu nie polega tylko na zapewnieniu p\u0142ynnego ruchu t\u0142oka. Si\u0142a po\u015blizgu wskazuje <strong>jako\u015b\u0107 wykonania<\/strong> strzykawki:<\/p><ul><li><strong>Du\u017ca si\u0142a po\u015blizgu<\/strong>: Nadmierne tarcie mo\u017ce prowadzi\u0107 do dyskomfortu podczas wstrzykiwania, a nawet mo\u017ce powodowa\u0107 trudno\u015bci w podawaniu leku przez pracownik\u00f3w s\u0142u\u017cby zdrowia.<\/li><li><strong>Niska si\u0142a po\u015blizgu<\/strong>: Niewystarczaj\u0105ce tarcie mo\u017ce powodowa\u0107 wycieki, czyni\u0105c strzykawk\u0119 zawodn\u0105 i potencjalnie niebezpieczn\u0105 do u\u017cytku medycznego.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a343f22 elementor-widget elementor-widget-heading\" data-id=\"a343f22\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Materia\u0142y wymagane do test\u00f3w si\u0142y po\u015blizgu strzykawki ISO 11040-4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78bacbc elementor-widget elementor-widget-text-editor\" data-id=\"78bacbc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Do skutecznego testowania niezb\u0119dne s\u0105 okre\u015blone materia\u0142y i sprz\u0119t, w tym<\/p><ul><li><strong>Sterylizowane strzykawki<\/strong>: Testowane strzykawki powinny by\u0107 gotowe do nape\u0142nienia i odpowiednio wysterylizowane, aby unikn\u0105\u0107 zanieczyszczenia.<\/li><li><strong>Zatyczki do t\u0142ok\u00f3w<\/strong>: Powinny one by\u0107 kompatybilne z cylindrem strzykawki i jej przeznaczeniem.<\/li><li><strong>Pr\u0119ty t\u0142oka<\/strong>: S\u0105 one niezb\u0119dne do przy\u0142o\u017cenia niezb\u0119dnej si\u0142y podczas test\u00f3w.<\/li><\/ul><p>Materia\u0142y te musz\u0105 zosta\u0107 uzgodnione mi\u0119dzy producentem a klientem, ze szczeg\u00f3lnym uwzgl\u0119dnieniem rodzaju korka t\u0142oka i jego smarowania.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba26707 elementor-widget elementor-widget-heading\" data-id=\"ba26707\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aparatura u\u017cywana w testach ISO 11040-4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e84859 elementor-widget elementor-widget-image\" data-id=\"3e84859\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/pl\/medical-syringe-tester\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/elementor\/thumbs\/syringe-glide-force-testing-iso-11040-4-1-scaled-r0grycyljh00j2lr5tp8u0op55p1txljfuzjxlcwi0.webp\" title=\"testowanie si\u0142y po\u015blizgu strzykawki iso 11040 4\" alt=\"testowanie si\u0142y po\u015blizgu strzykawki iso 11040 4\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e366efc elementor-widget elementor-widget-text-editor\" data-id=\"e366efc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Testy ISO 11040-4 wymagaj\u0105 specjalistycznego sprz\u0119tu:<\/p><ul><li><strong>Uniwersalna maszyna do pr\u00f3b rozci\u0105gania i \u015bciskania<\/strong>: Urz\u0105dzenie to s\u0142u\u017cy do przyk\u0142adania si\u0142y z okre\u015blon\u0105 pr\u0119dko\u015bci\u0105, zazwyczaj 100 mm\/min, w celu dok\u0142adnego pomiaru si\u0142y po\u015blizgu. Zakres si\u0142y powinien wynosi\u0107 co najmniej 50 N, w zale\u017cno\u015bci od specyfikacji strzykawki.<\/li><li><strong>Wspornik strzykawki i p\u0142ytki adaptera<\/strong>: S\u0142u\u017c\u0105 do przytrzymywania strzykawki w miejscu podczas testu, zapewniaj\u0105c prawid\u0142owe przy\u0142o\u017cenie si\u0142y.<\/li><li><strong>Rurka odpowietrzaj\u0105ca lub narz\u0119dzie do zatrzymywania pr\u00f3\u017cni<\/strong>: Narz\u0119dzie to s\u0142u\u017cy do instalowania zatyczki t\u0142oka w cylindrze strzykawki, zachowuj\u0105c sterylno\u015b\u0107 i prawid\u0142owe ustawienie.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e772501 elementor-widget elementor-widget-heading\" data-id=\"e772501\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedura przeprowadzania testu\n<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1923553 elementor-widget elementor-widget-text-editor\" data-id=\"1923553\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Test si\u0142y po\u015blizgu ISO 11040-4 przebiega zgodnie z systematyczn\u0105 procedur\u0105:<\/p><ol><li><strong>W\u0142\u00f3\u017c ogranicznik t\u0142oka<\/strong>: Umie\u015bci\u0107 korek t\u0142oka w cylindrze strzykawki przy u\u017cyciu rurki odpowietrzaj\u0105cej lub metody pr\u00f3\u017cniowej.<\/li><li><strong>Konfiguracja t\u0142oczyska<\/strong>: Przymocowa\u0107 pr\u0119t t\u0142oka do ogranicznika, upewniaj\u0105c si\u0119, \u017ce jest on wyr\u00f3wnany z urz\u0105dzeniem testuj\u0105cym.<\/li><li><strong>Umie\u015b\u0107 strzykawk\u0119 w urz\u0105dzeniu testuj\u0105cym<\/strong>: Umie\u015bci\u0107 strzykawk\u0119 w p\u0142ycie adaptera maszyny do pr\u00f3b rozci\u0105gania.<\/li><li><strong>Zastosuj si\u0142\u0119<\/strong>: Rozpocz\u0105\u0107 test \u015bciskania, przyk\u0142adaj\u0105c si\u0142\u0119 z ustalon\u0105 pr\u0119dko\u015bci\u0105, zazwyczaj 100 mm\/min.<\/li><li><strong>Pomiar maksymalnej si\u0142y<\/strong>: Zarejestrowa\u0107 maksymaln\u0105 si\u0142\u0119 odczuwan\u0105 w obszarze testowym si\u0142y po\u015blizgu, kt\u00f3ry jest odcinkiem mi\u0119dzy si\u0142\u0105 pocz\u0105tkow\u0105 a gwa\u0142townym wzrostem na ko\u0144cu skoku t\u0142oka.<\/li><li><strong>Powt\u00f3rz dla wielu pr\u00f3bek<\/strong>: Przeprowadzi\u0107 test dla kilku strzykawek, aby zapewni\u0107 sp\u00f3jno\u015b\u0107.<\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b869036 elementor-widget elementor-widget-heading\" data-id=\"b869036\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Obliczanie si\u0142y t\u0142oka strzykawki<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c126a7 elementor-widget elementor-widget-text-editor\" data-id=\"1c126a7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Wyniki testu s\u0105 dokumentowane, w tym:<\/p><ul><li><strong>Maksymalna si\u0142a po\u015blizgu<\/strong>: Najwy\u017csza si\u0142a zaobserwowana w obszarze testowym si\u0142y po\u015blizgu.<\/li><li><strong>\u015arednia si\u0142a po\u015blizgu<\/strong>: Obliczona \u015brednia si\u0142a, kt\u00f3ra zapewnia og\u00f3lny obraz wydajno\u015bci strzykawki.<\/li><li><strong>Dokumentacja testowa<\/strong>: Wszelkie odchylenia lub obserwacje nale\u017cy odnotowa\u0107 w celu zapewnienia identyfikowalno\u015bci i zgodno\u015bci.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c72def5 elementor-widget elementor-widget-heading\" data-id=\"c72def5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kluczowe aspekty dok\u0142adnego testowania si\u0142y po\u015blizgu<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9d3425 elementor-widget elementor-widget-text-editor\" data-id=\"f9d3425\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li><strong>Pr\u0119dko\u015b\u0107 testu<\/strong>: Zazwyczaj stosowana jest pr\u0119dko\u015b\u0107 100 mm\/min, ale mo\u017ce si\u0119 ona r\u00f3\u017cni\u0107 w zale\u017cno\u015bci od wymaga\u0144 producenta.<\/li><li><strong>Cz\u0119stotliwo\u015b\u0107 pr\u00f3bkowania<\/strong>: Wy\u017csza cz\u0119stotliwo\u015b\u0107 pr\u00f3bkowania (np. 500 Hz) jest zalecana dla dok\u0142adniejszych pomiar\u00f3w warto\u015bci szczytowych.<\/li><li><strong>\u015arodowisko testowe<\/strong>: \u015arodowisko testowe powinno by\u0107 kontrolowane, aby unikn\u0105\u0107 wp\u0142ywu czynnik\u00f3w zewn\u0119trznych na wyniki, takich jak temperatura lub wilgotno\u015b\u0107.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Glide Force Testing ISO 11040-4 Annex E In the medical and pharmaceutical industries, ensuring the performance and quality of syringes is paramount. One critical method for assessing syringe functionality is through the ISO 11040-4 syringe glide force testing. This standard helps manufacturers ensure that syringes, whether lubricated or non-lubricated, perform consistently and reliably when [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-1893","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/pl\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Syringe Glide Force Testing ISO 11040-4 Annex E In the medical and pharmaceutical industries, ensuring the performance and quality of syringes is paramount. One critical method for assessing syringe functionality is through the ISO 11040-4 syringe glide force testing. This standard helps manufacturers ensure that syringes, whether lubricated or non-lubricated, perform consistently and reliably when&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/1893","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/comments?post=1893"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/1893\/revisions"}],"predecessor-version":[{"id":2012,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/posts\/1893\/revisions\/2012"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/media?parent=1893"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/categories?post=1893"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/pl\/wp-json\/wp\/v2\/tags?post=1893"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}