{"id":2087,"date":"2025-04-27T08:38:09","date_gmt":"2025-04-27T08:38:09","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2087"},"modified":"2025-04-27T08:47:19","modified_gmt":"2025-04-27T08:47:19","slug":"luer-lock-rings-pull-off-force-test","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/nl\/luer-lock-rings-pull-off-force-test\/","title":{"rendered":"Test van de trekkracht van luersluitringen - ISO 11040-4 Bijlage G3"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2087\" class=\"elementor elementor-2087\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a57182 e-flex e-con-boxed e-con e-parent\" data-id=\"7a57182\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-caf1aa9 elementor-widget elementor-widget-heading\" data-id=\"caf1aa9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luersluitringen Trekkracht<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27efcf2 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"27efcf2\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49edf54 elementor-widget elementor-widget-heading\" data-id=\"49edf54\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bijlage G3<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-03ddeb3 e-flex e-con-boxed e-con e-parent\" data-id=\"03ddeb3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ccea8f2 elementor-widget elementor-widget-text-editor\" data-id=\"ccea8f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"455\" data-end=\"1006\">In de farmaceutische industrie en de sector voor medische apparatuur is de <em data-start=\"531\" data-end=\"563\">luer borgringen trekkracht<\/em> is een kritieke parameter om de betrouwbaarheid en veiligheid van voorgevulde spuiten te garanderen. Door goed te testen wordt gecontroleerd of de luer lock-adapter (LLA) goed vastzit, zodat deze niet per ongeluk losraakt tijdens gebruik.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c963d8 elementor-widget elementor-widget-heading\" data-id=\"0c963d8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Het belang van Luer Lock ringen pull-off kracht<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee545a5 elementor-widget elementor-widget-text-editor\" data-id=\"ee545a5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1013\" data-end=\"1449\">De <em data-start=\"1076\" data-end=\"1108\">luer borgringen trekkracht<\/em> meet de axiale kracht die nodig is om het LLA-kraagsysteem los te maken van het spuitvat. Nauwkeurige tests zorgen ervoor dat de spuit zijn integriteit behoudt tijdens het hanteren, vullen en toedienen, waardoor de kans op defecten aan het apparaat afneemt. Regelgevende normen schrijven deze tests voor om de veiligheid van de pati\u00ebnt te beschermen en claims over productprestaties te ondersteunen.<\/p><p class=\"\" data-start=\"1451\" data-end=\"1734\">Voor fabrikanten en kwaliteitsinspectiebureaus, met name voor de medische, farmaceutische en gezondheidszorgmarkten, is het essentieel om deze test onder de knie te krijgen. <strong data-start=\"1610\" data-end=\"1630\">Cel Instrumenten<\/strong> biedt geavanceerde oplossingen die met hoge precisie en betrouwbaarheid aan deze strenge eisen voldoen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4912cb5 elementor-widget elementor-widget-heading\" data-id=\"4912cb5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bijlage G3 Vereiste<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9bf8207 elementor-widget elementor-widget-text-editor\" data-id=\"9bf8207\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1741\" data-end=\"2070\"><em data-start=\"1838\" data-end=\"1851\">ISO 11040-4<\/em> definieert de eisen voor glazen vaten voor injectables en gesteriliseerde subassemblagespuiten die klaar zijn om gevuld te worden. Specifiek, <em data-start=\"1981\" data-end=\"2003\">ISO 11040-4 Bijlage G3<\/em> beschrijft de methode voor het meten van <em data-start=\"2037\" data-end=\"2069\">luer borgringen trekkracht<\/em>.<\/p><p class=\"\" data-start=\"2072\" data-end=\"2096\">Volgens Bijlage G3:<\/p><ul data-start=\"2097\" data-end=\"2989\"><li class=\"\" data-start=\"2097\" data-end=\"2237\"><p class=\"\" data-start=\"2099\" data-end=\"2237\"><strong data-start=\"2099\" data-end=\"2112\">Principe<\/strong>: De test beoordeelt of het LLA-systeem bestand is tegen een gedefinieerde axiale uittrekkracht bij aansluiting op een standaard luerfitting.<\/p><\/li><li class=\"\" data-start=\"2238\" data-end=\"2444\"><p class=\"\" data-start=\"2240\" data-end=\"2444\"><strong data-start=\"2240\" data-end=\"2253\">Apparaat<\/strong>: Er is een universele trek- en compressietestmachine nodig die kan werken bij een <strong data-start=\"2346\" data-end=\"2373\">testsnelheid van 20 mm\/min<\/strong>. Een meetcel met een typisch bereik van <strong data-start=\"2411\" data-end=\"2428\">10 N tot 100 N<\/strong> moet worden gebruikt.<\/p><\/li><li class=\"\" data-start=\"2445\" data-end=\"2524\"><p class=\"\" data-start=\"2447\" data-end=\"2524\"><strong data-start=\"2447\" data-end=\"2462\">Voorbereiding<\/strong>: Testmonsters moeten overeenkomen met de omstandigheden van het productieproces.<\/p><\/li><li class=\"\" data-start=\"2525\" data-end=\"2751\"><p class=\"\" data-start=\"2527\" data-end=\"2751\"><strong data-start=\"2527\" data-end=\"2540\">Procedure<\/strong>: Na het verwijderen van de tipdop wordt de spuit in een houder geplaatst zonder voordruk op de LLA uit te oefenen. De machine trekt vervolgens met constante snelheid totdat de LLA-kraag loslaat, waarbij de piekkracht wordt geregistreerd.<\/p><\/li><li class=\"\" data-start=\"2752\" data-end=\"2851\"><p class=\"\" data-start=\"2754\" data-end=\"2851\"><strong data-start=\"2754\" data-end=\"2765\">Resultaten<\/strong>: De piekkracht uit de kracht-verplaatsingscurve vertegenwoordigt de trekkracht.<\/p><\/li><li class=\"\" data-start=\"2852\" data-end=\"2989\"><p class=\"\" data-start=\"2854\" data-end=\"2989\"><strong data-start=\"2854\" data-end=\"2871\">Documentatie<\/strong>: Het rapport moet de testsnelheid, de piekwaarde, het aantal monsters, de goedkeurings- en afkeuringsresultaten en alle waargenomen afwijkingen bevatten.<\/p><\/li><\/ul><p class=\"\" data-start=\"2991\" data-end=\"3102\">Naar <em data-start=\"3001\" data-end=\"3023\">ISO 11040-4 Bijlage G3<\/em> garandeert dat resultaten betrouwbaar, reproduceerbaar en internationaal geaccepteerd zijn.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd67e63 elementor-widget elementor-widget-heading\" data-id=\"cd67e63\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hoe de Luer Lock Rings Trekkrachttest uit te voeren<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec7a39c elementor-widget elementor-widget-text-editor\" data-id=\"ec7a39c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3109\" data-end=\"3263\">Een nauwkeurige <a href=\"https:\/\/www.pharmacopoeiatest.com\/nl\/luer-lock-rings-pull-off-force-test\/\"><em data-start=\"3193\" data-end=\"3225\">luer borgringen trekkracht<\/em> test<\/a> omvat verschillende belangrijke stappen:<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-08466dd e-con-full e-flex e-con e-child\" data-id=\"08466dd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-33a3c77 elementor-widget elementor-widget-text-editor\" data-id=\"33a3c77\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>1. Monstervoorbereiding<\/strong><\/p><ul><li data-start=\"3292\" data-end=\"3363\">Gebruik gesteriliseerde subassemblagespuiten die de productieomstandigheden weerspiegelen.<\/li><li data-start=\"3292\" data-end=\"3363\">Verwijder de dop zonder het LLA kraagsysteem te belasten.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d451ca elementor-widget elementor-widget-text-editor\" data-id=\"5d451ca\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3427\" data-end=\"3452\"><strong>2. De test opzetten<\/strong><\/p><ul><li data-start=\"3455\" data-end=\"3551\">Monteer de spuit in de <strong data-start=\"3480\" data-end=\"3498\">spuithouder<\/strong> en zet de LLA-kraag vast in de <strong data-start=\"3532\" data-end=\"3550\">grijperapparaat<\/strong>.<\/li><li data-start=\"3455\" data-end=\"3551\">Zorg ervoor dat er geen druk wordt uitgeoefend op de kraag tijdens het instellen.<\/li><li data-start=\"3455\" data-end=\"3551\">Kalibreer de meetcel op \"nul\" zonder voorspanning toe te passen.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-95882a3 e-con-full e-flex e-con e-child\" data-id=\"95882a3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b1efd9c elementor-widget elementor-widget-text-editor\" data-id=\"b1efd9c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3675\" data-end=\"3699\"><strong>De test uitvoeren<\/strong><\/p><ul><li>Stel de snelheid van de machine in op <strong data-start=\"3727\" data-end=\"3740\">20 mm\/min<\/strong>.<\/li><li>Start de trektest en controleer kracht versus verplaatsing.<\/li><li>Registreer de piekkracht zodra de LLA-kraag loskomt van de spuit.<\/li><\/ul><p class=\"\" data-start=\"3875\" data-end=\"3902\"><strong data-start=\"3875\" data-end=\"3900\">De resultaten analyseren<\/strong><\/p><ul><li data-start=\"3905\" data-end=\"3964\">Identificeer het hoogste punt op de kracht-verplaatsingsgrafiek.<\/li><li data-start=\"3905\" data-end=\"3964\">Vergelijk het met gespecificeerde limieten om te bepalen of het systeem al dan niet geslaagd is.<\/li><li data-start=\"3905\" data-end=\"3964\">Documenteer alle parameters, inclusief monsterhoeveelheden, mislukkingen en afwijkingen.<\/li><\/ul><p class=\"\" data-start=\"4110\" data-end=\"4222\">A <strong data-start=\"4112\" data-end=\"4139\">bemonsteringsfrequentie van 500 Hz<\/strong> wordt aanbevolen om nauwkeurige piekmetingen vast te leggen tijdens het testen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37beef7 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"37beef7\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"496\" height=\"500\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp\" class=\"attachment-full size-full wp-image-2089\" alt=\"Test van de trekkracht van luersluitringen - ISO 11040-4 Bijlage G3\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp 496w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-298x300.webp 298w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-150x150.webp 150w\" sizes=\"(max-width: 496px) 100vw, 496px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fe809e1 e-con-full e-flex e-con e-child\" data-id=\"fe809e1\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-517a11d e-con-full e-flex e-con e-child\" data-id=\"517a11d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-661f7f9 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"661f7f9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 lektesten van spuiten\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-63b418a e-con-full e-flex e-con e-child\" data-id=\"63b418a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-45b4a2d elementor-widget elementor-widget-heading\" data-id=\"45b4a2d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aanbevolen apparatuur voor nauwkeurig testen<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef6391d elementor-widget elementor-widget-text-editor\" data-id=\"ef6391d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4229\" data-end=\"4441\">Op <strong data-start=\"4281\" data-end=\"4301\">Cel Instrumenten<\/strong>We zijn gespecialiseerd in het leveren van <strong data-start=\"4330\" data-end=\"4375\">universele trek- en compressietesters<\/strong> aangepast voor testtoepassingen met injectiespuiten. Onze systemen bieden:<\/p><ul data-start=\"4442\" data-end=\"4731\"><li class=\"\" data-start=\"4442\" data-end=\"4503\"><p class=\"\" data-start=\"4444\" data-end=\"4503\">Hoogfrequente bemonstering (tot 500 Hz) voor pieknauwkeurigheid.<\/p><\/li><li class=\"\" data-start=\"4504\" data-end=\"4582\"><p class=\"\" data-start=\"4506\" data-end=\"4582\">Spuithouders en LLA-grijpers op maat die voldoen aan ISO-specificaties.<\/p><\/li><li class=\"\" data-start=\"4583\" data-end=\"4658\"><p class=\"\" data-start=\"4585\" data-end=\"4658\">Load cells geschikt voor een reeks testkrachten tussen 10 N en 100 N.<\/p><\/li><li class=\"\" data-start=\"4659\" data-end=\"4731\"><p class=\"\" data-start=\"4661\" data-end=\"4731\">Intu\u00eftieve software voor volledige parametertraceerbaarheid en eenvoudige rapportage.<\/p><\/li><\/ul><p class=\"\" data-start=\"4733\" data-end=\"4901\">Onze oplossingen garanderen naleving van <em data-start=\"4773\" data-end=\"4786\">ISO 11040-4<\/em> en helpen de hoogste productkwaliteit te garanderen voor onze klanten in de farmaceutische industrie en medische hulpmiddelen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d05f85d elementor-widget elementor-widget-text-editor\" data-id=\"d05f85d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4908\" data-end=\"5324\">Het begrijpen en nauwkeurig meten van de <em data-start=\"4968\" data-end=\"5000\">luer borgringen trekkracht<\/em> volgens <em data-start=\"5014\" data-end=\"5036\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Bijlage G3<\/em> is van cruciaal belang om de veiligheid en betrouwbaarheid van injectiespuiten te garanderen. Door de juiste methodes te volgen en compliante, zeer nauwkeurige testinstrumenten van <strong data-start=\"5187\" data-end=\"5207\">Cel Instrumenten<\/strong>kunnen teams voor kwaliteitscontrole met vertrouwen de prestaties van producten verifi\u00ebren, voldoen aan wettelijke normen en eindgebruikers beschermen.<\/p><p class=\"\" data-start=\"5326\" data-end=\"5511\">Als je hulp nodig hebt bij het selecteren of aanpassen van de juiste testapparatuur voor het testen van spuiten, <strong data-start=\"5437\" data-end=\"5471\">neem vandaag nog contact op met Cell Instruments<\/strong> om onze volledige reeks oplossingen te verkennen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Trekkracht luer lock ringen ISO 11040-4 Annex G3 In de farmaceutische industrie en medische hulpmiddelen is de trekkracht van luer lock ringen een kritieke parameter om de betrouwbaarheid en veiligheid van voorgevulde spuiten te garanderen. Een goede test controleert of de luer lock adapter (LLA) goed vastzit om te voorkomen dat deze per ongeluk losraakt tijdens gebruik. Het belang van [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2087","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/nl\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Lock Rings Pull-Off Force ISO 11040-4 Annex G3 In the pharmaceutical and medical device industries, the luer lock rings pull-off force is a critical parameter to ensure the reliability and safety of prefilled syringes. Proper testing verifies the secure attachment of the luer lock adaptor (LLA) to prevent accidental detachment during use. Importance of&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/posts\/2087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/comments?post=2087"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/posts\/2087\/revisions"}],"predecessor-version":[{"id":2101,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/posts\/2087\/revisions\/2101"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/media?parent=2087"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/categories?post=2087"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/tags?post=2087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}