{"id":2073,"date":"2025-04-22T03:59:40","date_gmt":"2025-04-22T03:59:40","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2073"},"modified":"2025-04-22T06:49:25","modified_gmt":"2025-04-22T06:49:25","slug":"luer-cone-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/nl\/luer-cone-breakage-resistance-iso-11040-4\/","title":{"rendered":"Weerstand tegen breuk van de Luer-kegel - ISO 11040-4 Bijlage C2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2073\" class=\"elementor elementor-2073\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef785b6 e-flex e-con-boxed e-con e-parent\" data-id=\"ef785b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d4a251 elementor-widget elementor-widget-heading\" data-id=\"6d4a251\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer-kegel breukweerstand<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b910e1 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8b910e1\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec4bbc1 elementor-widget elementor-widget-heading\" data-id=\"ec4bbc1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bijlage C2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bdc54b0 e-flex e-con-boxed e-con e-parent\" data-id=\"bdc54b0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a300c79 elementor-widget elementor-widget-text-editor\" data-id=\"a300c79\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"400\" data-end=\"1016\">Bij de productie en kwaliteitscontrole van spuiten is een van de meest kritische mechanische beoordelingen de <strong data-start=\"520\" data-end=\"553\">breukvastheid luer conus<\/strong> test. De structurele integriteit van de voorkant van de spuit, met name de luer-conus, heeft een directe invloed op zowel de veiligheid van de pati\u00ebnt als de betrouwbaarheid van het apparaat. Om een consistente, gestandaardiseerde evaluatie te garanderen, is de <em data-start=\"749\" data-end=\"762\">ISO 11040-4<\/em> standaardspecifiek <em data-start=\"785\" data-end=\"795\">Bijlage C2<\/em>-beschrijft de procedures en vereisten voor het uitvoeren van deze test. Dit artikel leidt je door het testproces, essenti\u00eble apparatuur en gegevensinterpretatie die nodig zijn om te voldoen aan <a href=\"https:\/\/www.pharmacopoeiatest.com\/nl\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> testnormen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3c5bd5 elementor-widget elementor-widget-heading\" data-id=\"b3c5bd5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Belang van de breukbestendigheid van de Luer-kegel<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ddf4e elementor-widget elementor-widget-text-editor\" data-id=\"60ddf4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>De luer conus, aan de voorkant van het spuitvat, is een potentieel zwak punt dat vatbaar is voor mechanische spanning tijdens het hanteren, assembleren of injecteren. <strong data-start=\"1248\" data-end=\"1281\">Weerstand tegen luer conusbreuk<\/strong> Het testen helpt om te bepalen hoeveel kracht de kegel kan weerstaan voordat hij breekt. Voor fabrikanten van <em data-start=\"1384\" data-end=\"1405\">voorgevulde spuiten<\/em> en <em data-start=\"1410\" data-end=\"1441\">glazen vaten voor injectables<\/em>Deze test is niet alleen een wettelijke vereiste, het is een fundamentele maatregel voor kwaliteitscontrole om fouten in medische toepassingen te voorkomen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d476dd elementor-widget elementor-widget-heading\" data-id=\"3d476dd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bijlage C2 Testmethode voor de weerstand tegen breuk van de Luer-kegel<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642e2e7 elementor-widget elementor-widget-text-editor\" data-id=\"642e2e7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1582\" data-end=\"2040\">De <strong data-start=\"1636\" data-end=\"1651\">ISO 11040-4<\/strong> standaard, getiteld <em data-start=\"1669\" data-end=\"1784\">Voorgevulde spuiten - Deel 4: Glazen vaten voor injectables en gesteriliseerde voorgemonteerde spuiten, klaar voor vullen<\/em>omvat <strong data-start=\"1795\" data-end=\"1807\">Bijlage C2<\/strong>waarin de <em data-start=\"1827\" data-end=\"1858\">weerstand tegen frontale breuk<\/em> test. Dit hoofdstuk beschrijft de omstandigheden waaronder de test moet worden uitgevoerd, inclusief de vereisten voor de apparatuur, de behandeling van monsters, de testprocedures en documentatie van de resultaten.<\/p><h3 class=\"\" data-start=\"2042\" data-end=\"2077\">De belangrijkste testomstandigheden zijn onder andere:<\/h3><ul><li data-start=\"2080\" data-end=\"2105\">Testsnelheid: <strong data-start=\"2092\" data-end=\"2105\">25 mm\/min<\/strong><\/li><li data-start=\"2080\" data-end=\"2105\">Toepassingspunt: <strong style=\"font-size: 16px;\" data-start=\"2127\" data-end=\"2135\">2 mm<\/strong><span style=\"font-size: 16px;\"> van de spuitpunt<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Minimale bemonsteringsfrequentie: <strong style=\"font-size: 16px;\" data-start=\"2182\" data-end=\"2192\">500 Hz<\/strong><span style=\"font-size: 16px;\"> voor piekmeetnauwkeurigheid<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Kracht uitgeoefend tot <strong style=\"font-size: 16px;\" data-start=\"2245\" data-end=\"2263\">glasbreuk<\/strong><span style=\"font-size: 16px;\"> gebeurt<\/span><\/li><\/ul><p class=\"\" data-start=\"2272\" data-end=\"2390\">Als je deze richtlijnen volgt, zorg je ervoor dat je <strong data-start=\"2314\" data-end=\"2333\">testen met injectiespuiten<\/strong> processen traceerbaar, reproduceerbaar en conform blijven.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4dbc7e2 elementor-widget elementor-widget-heading\" data-id=\"4dbc7e2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Spuittester voor ISO 11040-4 Bijlage C2 testen<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7da5e4d elementor-widget elementor-widget-text-editor\" data-id=\"7da5e4d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2454\" data-end=\"2671\">Om nauwkeurig <strong data-start=\"2476\" data-end=\"2509\">breukvastheid luer conus<\/strong> tests heb je een betrouwbare en nauwkeurige <strong data-start=\"2552\" data-end=\"2605\">universele trek- en compressietestmachine<\/strong>. Het apparaat moet voldoen aan deze ISO 11040-4 Bijlage C2 vereisten:<\/p><ul><li data-start=\"2675\" data-end=\"2729\">A <strong data-start=\"2677\" data-end=\"2690\">laadcel<\/strong> geschikt voor het meten van breekkrachten<\/li><li data-start=\"2675\" data-end=\"2729\">Een nauwkeurige, programmeerbare <strong style=\"font-size: 16px;\" data-start=\"2758\" data-end=\"2780\">testsnelheidsregeling<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Een aangepaste <strong style=\"font-size: 16px;\" data-start=\"2792\" data-end=\"2834\">roestvrijstalen houder en laadstang<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Adaptersets die passen bij de geometrie van je spuitontwerp<\/li><\/ul><h3 class=\"\" data-start=\"2889\" data-end=\"2967\">Aanbevolen spuittester<\/h3><p class=\"\" data-start=\"2969\" data-end=\"3383\">Cel-instrumenten <em>Spuittester<\/em>\u00a0is ontworpen om te voldoen aan de strenge eisen van ISO spuittesten. De MPT-01 is uitgerust met programmeerbare PLC-besturing, precisiemechanica en aanpasbare armaturen en levert hoge-resolutie kracht- en verplaatsingsgegevens, waardoor hij ideaal is voor <strong data-start=\"3241\" data-end=\"3274\">breukvastheid luer conus<\/strong> beoordelingen. De ge\u00efntegreerde microprinter en optionele RS232 data export ondersteunen ook gedetailleerde documentatie.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4ff2b elementor-widget elementor-widget-heading\" data-id=\"6b4ff2b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testprocedure voor de breukweerstand van de Luer-kegel<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c990a3c e-con-full e-flex e-con e-child\" data-id=\"c990a3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-dbcf8eb e-con-full e-flex e-con e-child\" data-id=\"dbcf8eb\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53324d6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"53324d6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 lektesten van spuiten\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9962325 e-con-full e-flex e-con e-child\" data-id=\"9962325\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea7609b elementor-widget elementor-widget-text-editor\" data-id=\"ea7609b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3460\" data-end=\"3483\"><strong>1. Testvoorbereiding<\/strong><\/p><ul><li data-start=\"3486\" data-end=\"3553\">Inspecteer alle adapters en materialen op <strong data-start=\"3525\" data-end=\"3552\">schade of compatibiliteit<\/strong>.<\/li><li data-start=\"3486\" data-end=\"3553\">Monteer de vereiste adapter en armaturen op de <strong style=\"font-size: 16px;\">Spuittester<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3486\" data-end=\"3553\">Zorg voor de juiste uitlijning en <strong style=\"font-size: 16px;\" data-start=\"3652\" data-end=\"3677\">installeer veiligheidsafschermingen<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul><p data-start=\"3680\" data-end=\"3704\"><strong>2. Uitvoering testen<\/strong><\/p><ul><li data-start=\"3707\" data-end=\"3749\">Plaats de spuitbus in de houder.<\/li><li data-start=\"3707\" data-end=\"3749\">Plaats de laadpen <strong style=\"font-size: 16px;\" data-start=\"3777\" data-end=\"3806\">2 mm van de spuitpunt<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Stel de snelheid in op <strong style=\"font-size: 16px;\" data-start=\"3827\" data-end=\"3840\">25 mm\/min<\/strong><span style=\"font-size: 16px;\"> en start de test.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Oefen druk uit totdat de luerconus <strong style=\"font-size: 16px;\" data-start=\"3901\" data-end=\"3914\">breuken<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Noteer de <strong style=\"font-size: 16px;\" data-start=\"3929\" data-end=\"3958\">maximale kracht bij breuk<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4898eec elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"4898eec\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"272\" height=\"270\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png\" class=\"attachment-large size-large wp-image-2078\" alt=\"Weerstand tegen breken van de Luer-kegel - ISO 11040-4 Bijlage C2 Spuittests\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png 272w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing-150x150.png 150w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322584f elementor-widget elementor-widget-text-editor\" data-id=\"322584f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3961\" data-end=\"3999\"><b>3. Opschoning en analyse na de test<\/b><\/p><ul><li data-start=\"4002\" data-end=\"4038\">Verwijder de kapotte spuit voorzichtig.<\/li><li data-start=\"4002\" data-end=\"4038\">Reinig de adapter om glasresten te verwijderen.<\/li><li data-start=\"4002\" data-end=\"4038\">Resultaten analyseren en bevestigen <strong style=\"font-size: 16px;\" data-start=\"4117\" data-end=\"4138\">breuklocatie<\/strong><span style=\"font-size: 16px;\"> aan de voorkant.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04ee823 elementor-widget elementor-widget-heading\" data-id=\"04ee823\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Vereisten voor resultaatrapportage volgens ISO 11040-4<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a8c95c elementor-widget elementor-widget-text-editor\" data-id=\"9a8c95c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4216\" data-end=\"4286\">Elke test moet grondig worden gedocumenteerd, inclusief de volgende gegevens:<\/p><ul><li data-start=\"4289\" data-end=\"4313\"><strong data-start=\"4289\" data-end=\"4303\">Testsnelheid<\/strong> in mm\/min<\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4316\" data-end=\"4349\">Afstand tot de spuitpunt<\/strong><span style=\"font-size: 16px;\"> waarop de kracht werd uitgeoefend<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4383\" data-end=\"4409\">Maximale breekkracht<\/strong><span style=\"font-size: 16px;\"> in newton (N)<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4427\" data-end=\"4446\">Hoeveelheid monster<\/strong><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4449\" data-end=\"4480\">Eventuele afwijkingen<\/strong><span style=\"font-size: 16px;\"> van de procedure<\/span><\/li><\/ul><p class=\"\" data-start=\"4501\" data-end=\"4652\">Dit detailniveau garandeert consistentie en maakt traceerbaarheid mogelijk, vooral bij het valideren van nieuwe spuitontwerpen of het uitvoeren van routinematige kwaliteitscontroles.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c3b5bb elementor-widget elementor-widget-heading\" data-id=\"5c3b5bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Waarom Cell Instruments kiezen voor spuittesten?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7471474 elementor-widget elementor-widget-text-editor\" data-id=\"7471474\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4659\" data-end=\"5243\">Met tientallen jaren ervaring in <strong data-start=\"4744\" data-end=\"4779\">testen van materiaal voor medische hulpmiddelen<\/strong>, <strong data-start=\"4781\" data-end=\"4801\">Cel Instrumenten<\/strong> biedt geavanceerde testoplossingen die voldoen aan ISO- en ASTM-normen. Onze <strong>Spuittester<\/strong> is speciaal ontworpen om een verscheidenheid aan <strong data-start=\"4971\" data-end=\"4990\">testen met injectiespuiten<\/strong> methoden, waaronder <strong data-start=\"5010\" data-end=\"5043\">breukvastheid luer conus<\/strong>. Of het nu gaat om productie, onderzoek of verificatie door derden, Cell Instruments biedt oplossingen op maat, automatiseringsintegratie en uitgebreide ondersteuning om aan uw testbehoeften te voldoen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02c15b6 elementor-widget elementor-widget-text-editor\" data-id=\"02c15b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5250\" data-end=\"5668\">Uitvoeren <strong data-start=\"5278\" data-end=\"5311\">breukvastheid luer conus<\/strong> tests in overeenstemming met <strong data-start=\"5337\" data-end=\"5361\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Bijlage C2<\/strong> is essentieel om de mechanische integriteit van spuitonderdelen te garanderen. Door gebruik te maken van nauwkeurige apparatuur zoals de <strong>Spuittester<\/strong>Als u de ISO-procedure stap voor stap volgt, kunt u met vertrouwen de productkwaliteit verifi\u00ebren, de naleving van de regelgeving handhaven en de veiligheid van de pati\u00ebnt beschermen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3344b6 elementor-widget elementor-widget-text-editor\" data-id=\"a3344b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\"><strong data-start=\"5675\" data-end=\"5746\">Op zoek naar testoplossingen voor injectiespuiten die voldoen aan ISO 11040-4?<\/strong><\/p><p class=\"\" data-start=\"5420\" data-end=\"5503\">Neem contact op met <strong data-start=\"5757\" data-end=\"5787\">Cell Instruments Co.<\/strong> vandaag nog voor deskundige begeleiding en op maat gemaakte testsystemen voor uw kwaliteitsborging van spuiten.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Weerstand tegen breuk van luer conus ISO 11040-4 Annex C2 Bij de productie en kwaliteitscontrole van injectiespuiten is een van de meest kritische mechanische beoordelingen de weerstandstest tegen breuk van de luer conus. De structurele integriteit van de voorkant van de spuit, met name de luerconus, heeft een directe invloed op zowel de veiligheid van de pati\u00ebnt als de betrouwbaarheid van het apparaat. Om een consistente, gestandaardiseerde evaluatie te garanderen, heeft de ISO [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2073","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/nl\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/posts\/2073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/comments?post=2073"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/posts\/2073\/revisions"}],"predecessor-version":[{"id":2084,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/posts\/2073\/revisions\/2084"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/media?parent=2073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/categories?post=2073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nl\/wp-json\/wp\/v2\/tags?post=2073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}