{"id":2073,"date":"2025-04-22T03:59:40","date_gmt":"2025-04-22T03:59:40","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2073"},"modified":"2025-04-22T06:49:25","modified_gmt":"2025-04-22T06:49:25","slug":"luer-cone-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/nb\/luer-cone-breakage-resistance-iso-11040-4\/","title":{"rendered":"Bruddmotstand for luerkonus - ISO 11040-4 vedlegg C2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2073\" class=\"elementor elementor-2073\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef785b6 e-flex e-con-boxed e-con e-parent\" data-id=\"ef785b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d4a251 elementor-widget elementor-widget-heading\" data-id=\"6d4a251\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer Cone Breakage Resistance (motstand mot brudd)<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b910e1 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8b910e1\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec4bbc1 elementor-widget elementor-widget-heading\" data-id=\"ec4bbc1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Vedlegg C2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bdc54b0 e-flex e-con-boxed e-con e-parent\" data-id=\"bdc54b0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a300c79 elementor-widget elementor-widget-text-editor\" data-id=\"a300c79\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"400\" data-end=\"1016\">Ved produksjon og kvalitetskontroll av spr\u00f8yter er en av de mest kritiske mekaniske vurderingene <strong data-start=\"520\" data-end=\"553\">motstand mot brudd p\u00e5 luerkonus<\/strong> test. Den strukturelle integriteten til spr\u00f8ytefronten, spesielt luerkonusen, har direkte innvirkning p\u00e5 b\u00e5de pasientsikkerheten og utstyrets p\u00e5litelighet. For \u00e5 sikre en konsekvent og standardisert evaluering, har <em data-start=\"749\" data-end=\"762\">ISO 11040-4<\/em> standard - spesifikt <em data-start=\"785\" data-end=\"795\">Vedlegg C2<\/em>-beskrivelser av prosedyrene og kravene for \u00e5 gjennomf\u00f8re denne testen. Denne artikkelen tar deg gjennom testprosessen, viktig utstyr og tolkning av data som er n\u00f8dvendig for \u00e5 overholde <a href=\"https:\/\/www.pharmacopoeiatest.com\/nb\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> teststandarder.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3c5bd5 elementor-widget elementor-widget-heading\" data-id=\"b3c5bd5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Betydningen av motstand mot brudd p\u00e5 Luer Cone<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ddf4e elementor-widget elementor-widget-text-editor\" data-id=\"60ddf4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Luerkonus, som er plassert i den fremre enden av spr\u00f8ytehylsen, er et potensielt svakt punkt som kan utsettes for mekaniske p\u00e5kjenninger under h\u00e5ndtering, montering eller injeksjon. <strong data-start=\"1248\" data-end=\"1281\">Motstand mot brudd p\u00e5 luerkonus<\/strong> testing bidrar til \u00e5 avgj\u00f8re hvor mye kraft kjeglen t\u00e5ler f\u00f8r den sprekker. For produsenter av <em data-start=\"1384\" data-end=\"1405\">ferdigfylte spr\u00f8yter<\/em> og <em data-start=\"1410\" data-end=\"1441\">glassfat for injeksjonsv\u00e6sker<\/em>er denne testen ikke bare et lovp\u00e5lagt krav - det er et grunnleggende kvalitetskontrolltiltak for \u00e5 unng\u00e5 feil i medisinske applikasjoner.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d476dd elementor-widget elementor-widget-heading\" data-id=\"3d476dd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Annex C2 Luer Cone Breakage Resistance Test Method<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642e2e7 elementor-widget elementor-widget-text-editor\" data-id=\"642e2e7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1582\" data-end=\"2040\">Den <strong data-start=\"1636\" data-end=\"1651\">ISO 11040-4<\/strong> standard, med tittelen <em data-start=\"1669\" data-end=\"1784\">Ferdigfylte spr\u00f8yter - Del 4: Glassfat for injeksjonsv\u00e6sker og steriliserte, ferdig monterte spr\u00f8yter klare til fylling<\/em>, inkluderer <strong data-start=\"1795\" data-end=\"1807\">Vedlegg C2<\/strong>, som beskriver <em data-start=\"1827\" data-end=\"1858\">motstand mot brudd i frontenden<\/em> test. Dette avsnittet beskriver betingelsene som testen m\u00e5 utf\u00f8res under, inkludert krav til apparatur, pr\u00f8veh\u00e5ndtering, testprosedyrer og dokumentasjon av resultater.<\/p><h3 class=\"\" data-start=\"2042\" data-end=\"2077\">Viktige testbetingelser inkluderer:<\/h3><ul><li data-start=\"2080\" data-end=\"2105\">Test hastighet: <strong data-start=\"2092\" data-end=\"2105\">25 mm\/min<\/strong><\/li><li data-start=\"2080\" data-end=\"2105\">P\u00e5f\u00f8ringspunkt: <strong style=\"font-size: 16px;\" data-start=\"2127\" data-end=\"2135\">2 mm<\/strong><span style=\"font-size: 16px;\"> fra spr\u00f8ytespissen<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Minimum samplingsfrekvens: <strong style=\"font-size: 16px;\" data-start=\"2182\" data-end=\"2192\">500 Hz<\/strong><span style=\"font-size: 16px;\"> for maksimal m\u00e5len\u00f8yaktighet<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">P\u00e5f\u00f8rt kraft inntil <strong style=\"font-size: 16px;\" data-start=\"2245\" data-end=\"2263\">glassbrudd<\/strong><span style=\"font-size: 16px;\"> forekommer<\/span><\/li><\/ul><p class=\"\" data-start=\"2272\" data-end=\"2390\">Ved \u00e5 f\u00f8lge denne veiledningen sikrer du at <strong data-start=\"2314\" data-end=\"2333\">spr\u00f8ytetesting<\/strong> prosessene forblir sporbare, reproduserbare og samsvarende.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4dbc7e2 elementor-widget elementor-widget-heading\" data-id=\"4dbc7e2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Spr\u00f8ytetester for ISO 11040-4 Annex C2-testing<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7da5e4d elementor-widget elementor-widget-text-editor\" data-id=\"7da5e4d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2454\" data-end=\"2671\">For \u00e5 utf\u00f8re n\u00f8yaktig <strong data-start=\"2476\" data-end=\"2509\">motstand mot brudd p\u00e5 luerkonus<\/strong> tester, trenger du en p\u00e5litelig og presis <strong data-start=\"2552\" data-end=\"2605\">universell strekk- og kompresjonstestmaskin<\/strong>. Apparatet m\u00e5 oppfylle disse kravene i ISO 11040-4 vedlegg C2:<\/p><ul><li data-start=\"2675\" data-end=\"2729\">A <strong data-start=\"2677\" data-end=\"2690\">lastcelle<\/strong> egnet for m\u00e5ling av bruddkrefter<\/li><li data-start=\"2675\" data-end=\"2729\">En n\u00f8yaktig, programmerbar <strong style=\"font-size: 16px;\" data-start=\"2758\" data-end=\"2780\">testhastighetskontroll<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">En tilpasset <strong style=\"font-size: 16px;\" data-start=\"2792\" data-end=\"2834\">holder og lastestang i rustfritt st\u00e5l<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Adaptersett som passer til spr\u00f8ytegeometrien din<\/li><\/ul><h3 class=\"\" data-start=\"2889\" data-end=\"2967\">Anbefalt spr\u00f8ytetester<\/h3><p class=\"\" data-start=\"2969\" data-end=\"3383\">Cell Instruments' <em>Spr\u00f8ytetester<\/em>\u00a0er utformet for \u00e5 oppfylle de strenge kravene til ISO-spr\u00f8ytetesting. MPT-01 er utstyrt med programmerbar PLS-kontroll, presisjonsmekanikk og tilpassbare fiksturer, og gir kraft- og forskyvningsdata med h\u00f8y oppl\u00f8sning, noe som gj\u00f8r den ideell for <strong data-start=\"3241\" data-end=\"3274\">motstand mot brudd p\u00e5 luerkonus<\/strong> vurderinger. Den integrerte mikroskriveren og den valgfrie RS232-dataeksporten st\u00f8tter ogs\u00e5 detaljert dokumentasjon.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4ff2b elementor-widget elementor-widget-heading\" data-id=\"6b4ff2b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prosedyre for testing av motstand mot luerkonusbrudd<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c990a3c e-con-full e-flex e-con e-child\" data-id=\"c990a3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-dbcf8eb e-con-full e-flex e-con e-child\" data-id=\"dbcf8eb\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53324d6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"53324d6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 lekkasjetesting av spr\u00f8yter\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9962325 e-con-full e-flex e-con e-child\" data-id=\"9962325\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea7609b elementor-widget elementor-widget-text-editor\" data-id=\"ea7609b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3460\" data-end=\"3483\"><strong>1. Forberedelse av test<\/strong><\/p><ul><li data-start=\"3486\" data-end=\"3553\">Inspiser alle adaptere og materialer for <strong data-start=\"3525\" data-end=\"3552\">skade eller kompatibilitet<\/strong>.<\/li><li data-start=\"3486\" data-end=\"3553\">Monter den n\u00f8dvendige adapteren og armaturene p\u00e5 <strong style=\"font-size: 16px;\">Spr\u00f8ytetester<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3486\" data-end=\"3553\">S\u00f8rg for riktig justering og <strong style=\"font-size: 16px;\" data-start=\"3652\" data-end=\"3677\">installere sikkerhetsvakter<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul><p data-start=\"3680\" data-end=\"3704\"><strong>2. Testgjennomf\u00f8ring<\/strong><\/p><ul><li data-start=\"3707\" data-end=\"3749\">Sett spr\u00f8ytehylsen inn i holderen.<\/li><li data-start=\"3707\" data-end=\"3749\">Plasser lastestiften <strong style=\"font-size: 16px;\" data-start=\"3777\" data-end=\"3806\">2 mm fra spr\u00f8ytespissen<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Still inn hastigheten til <strong style=\"font-size: 16px;\" data-start=\"3827\" data-end=\"3840\">25 mm\/min<\/strong><span style=\"font-size: 16px;\"> og start testen.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">P\u00e5f\u00f8r kompresjon til luerkonus <strong style=\"font-size: 16px;\" data-start=\"3901\" data-end=\"3914\">brudd<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Ta opp <strong style=\"font-size: 16px;\" data-start=\"3929\" data-end=\"3958\">maksimal kraft ved brudd<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4898eec elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"4898eec\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"272\" height=\"270\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png\" class=\"attachment-large size-large wp-image-2078\" alt=\"Bruddmotstand for luerkonus - ISO 11040-4 Annex C2 Spr\u00f8ytetesting\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png 272w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing-150x150.png 150w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322584f elementor-widget elementor-widget-text-editor\" data-id=\"322584f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3961\" data-end=\"3999\"><b>3. Opprydding og analyse etter testen<\/b><\/p><ul><li data-start=\"4002\" data-end=\"4038\">Fjern den \u00f8delagte spr\u00f8yten forsiktig.<\/li><li data-start=\"4002\" data-end=\"4038\">Rengj\u00f8r adapteren for \u00e5 fjerne eventuelle glassrester.<\/li><li data-start=\"4002\" data-end=\"4038\">Analyser resultatene og bekreft <strong style=\"font-size: 16px;\" data-start=\"4117\" data-end=\"4138\">bruddsted<\/strong><span style=\"font-size: 16px;\"> i den fremre enden.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04ee823 elementor-widget elementor-widget-heading\" data-id=\"04ee823\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Krav til resultatrapportering i henhold til ISO 11040-4<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a8c95c elementor-widget elementor-widget-text-editor\" data-id=\"9a8c95c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4216\" data-end=\"4286\">Hver test m\u00e5 dokumenteres grundig, inkludert f\u00f8lgende data:<\/p><ul><li data-start=\"4289\" data-end=\"4313\"><strong data-start=\"4289\" data-end=\"4303\">Test hastighet<\/strong> i mm\/min<\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4316\" data-end=\"4349\">Avstand fra spr\u00f8ytespissen<\/strong><span style=\"font-size: 16px;\"> hvor kraften ble p\u00e5f\u00f8rt<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4383\" data-end=\"4409\">Maksimal bruddkraft<\/strong><span style=\"font-size: 16px;\"> i newton (N)<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4427\" data-end=\"4446\">Eksempel p\u00e5 antall<\/strong><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4449\" data-end=\"4480\">Eventuelle uregelmessigheter eller avvik<\/strong><span style=\"font-size: 16px;\"> fra prosedyren<\/span><\/li><\/ul><p class=\"\" data-start=\"4501\" data-end=\"4652\">Dette detaljniv\u00e5et sikrer konsistens og muliggj\u00f8r sporbarhet, spesielt ved validering av nye spr\u00f8ytedesign eller rutinemessige kvalitetskontroller.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c3b5bb elementor-widget elementor-widget-heading\" data-id=\"5c3b5bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor velge Cell Instruments for spr\u00f8ytetesting?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7471474 elementor-widget elementor-widget-text-editor\" data-id=\"7471474\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4659\" data-end=\"5243\">Med flere ti\u00e5r med erfaring innen <strong data-start=\"4744\" data-end=\"4779\">testing av materialer til medisinsk utstyr<\/strong>, <strong data-start=\"4781\" data-end=\"4801\">Cell Instruments<\/strong> tilbyr toppmoderne testl\u00f8sninger som er skreddersydd i henhold til ISO- og ASTM-standarder. V\u00e5re <strong>Spr\u00f8ytetester<\/strong> er spesielt utviklet for \u00e5 st\u00f8tte en rekke ulike <strong data-start=\"4971\" data-end=\"4990\">spr\u00f8ytetesting<\/strong> metoder, inkludert <strong data-start=\"5010\" data-end=\"5043\">motstand mot brudd p\u00e5 luerkonus<\/strong>. Enten du driver med produksjon, forskning eller tredjepartsverifisering, kan Cell Instruments tilby tilpassede l\u00f8sninger, automatiseringsintegrasjon og omfattende st\u00f8tte for \u00e5 dekke testbehovene dine.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02c15b6 elementor-widget elementor-widget-text-editor\" data-id=\"02c15b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5250\" data-end=\"5668\">Utf\u00f8rer <strong data-start=\"5278\" data-end=\"5311\">motstand mot brudd p\u00e5 luerkonus<\/strong> tester i samsvar med <strong data-start=\"5337\" data-end=\"5361\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Vedlegg C2<\/strong> er avgj\u00f8rende for \u00e5 sikre den mekaniske integriteten til spr\u00f8ytekomponentene. Ved \u00e5 bruke n\u00f8yaktig utstyr som <strong>Spr\u00f8ytetester<\/strong>Ved \u00e5 f\u00f8lge den ISO-anbefalte prosedyren trinn for trinn kan du trygt verifisere produktkvaliteten, opprettholde samsvar med regelverket og beskytte pasientsikkerheten.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3344b6 elementor-widget elementor-widget-text-editor\" data-id=\"a3344b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\"><strong data-start=\"5675\" data-end=\"5746\">Leter du etter l\u00f8sninger for spr\u00f8ytetesting som er i samsvar med ISO 11040-4?<\/strong><\/p><p class=\"\" data-start=\"5420\" data-end=\"5503\">Kontakt <strong data-start=\"5757\" data-end=\"5787\">Cell Instruments Co, Ltd.<\/strong> i dag for ekspertveiledning og skreddersydde testsystemer for dine behov for kvalitetssikring av spr\u00f8yter.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2073","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/nb\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/posts\/2073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/comments?post=2073"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/posts\/2073\/revisions"}],"predecessor-version":[{"id":2084,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/posts\/2073\/revisions\/2084"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/media?parent=2073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/categories?post=2073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/tags?post=2073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}