{"id":2059,"date":"2025-04-22T02:54:20","date_gmt":"2025-04-22T02:54:20","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2059"},"modified":"2025-04-22T03:29:50","modified_gmt":"2025-04-22T03:29:50","slug":"flange-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/nb\/flange-breakage-resistance-iso-11040-4\/","title":{"rendered":"Motstand mot flensbrudd - ISO 11040-4 vedlegg C1"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2059\" class=\"elementor elementor-2059\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99d088f e-flex e-con-boxed e-con e-parent\" data-id=\"99d088f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-43cc8ff elementor-widget elementor-widget-heading\" data-id=\"43cc8ff\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Motstand mot flensbrudd<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9d7284 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"f9d7284\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1129df5 elementor-widget elementor-widget-heading\" data-id=\"1129df5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Vedlegg C1<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b7ccfb2 e-flex e-con-boxed e-con e-parent\" data-id=\"b7ccfb2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-254e154 elementor-widget elementor-widget-text-editor\" data-id=\"254e154\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"477\" data-end=\"932\"><em data-start=\"477\" data-end=\"505\">Motstand mot flensbrudd<\/em> er en kritisk kvalitetsegenskap ved produksjon av ferdigfylte spr\u00f8yter. Denne testen bestemmer den mekaniske styrken til spr\u00f8ytefatets flens - den delen som m\u00e5 t\u00e5le p\u00e5f\u00f8rte krefter under klinisk bruk. Etter hvert som helseforskriftene strammes inn globalt, er det viktig \u00e5 oppfylle de mekaniske ytelsesstandardene som er beskrevet i <a href=\"https:\/\/www.pharmacopoeiatest.com\/nb\/flange-breakage-resistance-iso-11040-4\/\"><strong data-start=\"819\" data-end=\"843\">ISO 11040-4 Vedlegg C1<\/strong><\/a> er avgj\u00f8rende for produsenter av glassspr\u00f8yter og steriliserte, sammensatte spr\u00f8yter.<\/p><p class=\"\" data-start=\"934\" data-end=\"1146\">Cell Instruments, en ledende akt\u00f8r innen presisjonsutstyr for testing, tilbyr robuste l\u00f8sninger som sikrer at din <em data-start=\"1037\" data-end=\"1054\">spr\u00f8ytetesting<\/em> overholder internasjonale standarder og samtidig maksimerer n\u00f8yaktigheten og driftseffektiviteten.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ededb4f elementor-widget elementor-widget-heading\" data-id=\"ededb4f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 og dens anvendelse i spr\u00f8ytetesting<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1f63cd elementor-widget elementor-widget-text-editor\" data-id=\"a1f63cd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1223\" data-end=\"1586\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/nb\/iso-11040-4\/\"><strong data-start=\"1223\" data-end=\"1238\">ISO 11040-4<\/strong><\/a> regulerer glassfat for injeksjonsv\u00e6sker, med s\u00e6rlig fokus p\u00e5 strukturell integritet og funksjonalitet. I <em data-start=\"1346\" data-end=\"1368\">ISO 11040-4 Vedlegg C1<\/em>er det fastsatt spesifikke retningslinjer for evaluering av <em data-start=\"1418\" data-end=\"1446\">motstand mot flensbrudd<\/em>. M\u00e5let med denne testen er \u00e5 simulere forhold der en spr\u00f8yteflens kan g\u00e5 i stykker under h\u00e5ndtering eller automatiserte fylleprosesser.<\/p><p class=\"\" data-start=\"1588\" data-end=\"1752\">Standarden gjelder ikke bare for ferdige spr\u00f8ytet\u00f8nner, men ogs\u00e5 for steriliserte, sammensatte spr\u00f8yter som er klare til fylling, noe som sikrer konsistens i hele forsyningskjeden.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d261813 elementor-widget elementor-widget-heading\" data-id=\"d261813\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor testing av flensbruddmotstand er viktig<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f45136 elementor-widget elementor-widget-text-editor\" data-id=\"3f45136\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1811\" data-end=\"2112\">Spr\u00f8yter utsettes for en rekke mekaniske p\u00e5kjenninger under transport, lagring, fylling og administrering. Flensen, en strukturell komponent i enden av spr\u00f8ytet\u00f8nnen, er et kjent svakt punkt. Hvis flensen svikter, kan det g\u00e5 ut over steriliteten, doseringsn\u00f8yaktigheten og i siste instans pasientens sikkerhet.<\/p><p class=\"\" data-start=\"2114\" data-end=\"2168\">N\u00f8yaktig <em data-start=\"2123\" data-end=\"2151\">motstand mot flensbrudd<\/em> testing hjelper:<\/p><ul><li data-start=\"2171\" data-end=\"2216\">Valider design- og produksjonsprosesser<\/li><li data-start=\"2171\" data-end=\"2216\">Oppfyller lovp\u00e5lagte krav<\/li><li data-start=\"2171\" data-end=\"2216\">Reduser risikoen for produktfeil i felten<\/li><li data-start=\"2171\" data-end=\"2216\">Bygge tillit hos tilsynsorganer og kunder<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fd48bf elementor-widget elementor-widget-heading\" data-id=\"3fd48bf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Annex C1 Testmetode for flensbruddmotstand<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ef26935 e-con-full e-flex e-con e-child\" data-id=\"ef26935\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-25fc654 e-con-full e-flex e-con e-child\" data-id=\"25fc654\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1372d22 elementor-widget elementor-widget-heading\" data-id=\"1372d22\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tester for flensbruddmotstand p\u00e5krevd<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3c025e elementor-widget elementor-widget-text-editor\" data-id=\"c3c025e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2399\" data-end=\"2565\">Metoden som er beskrevet i <strong data-start=\"2422\" data-end=\"2446\">ISO 11040-4 Vedlegg C1<\/strong> best\u00e5r i \u00e5 p\u00e5f\u00f8re en kontrollert trykkraft p\u00e5 spr\u00f8yteflensen til den svikter. Slik gj\u00f8r du det:<\/p><ul data-start=\"2590\" data-end=\"2834\"><li class=\"\" data-start=\"2590\" data-end=\"2707\"><p class=\"\" data-start=\"2592\" data-end=\"2707\"><strong data-start=\"2592\" data-end=\"2645\">Universell strekk- og kompresjonstestmaskin<\/strong> (f.eks. Cell Instruments' <em>Spr\u00f8ytetester<\/em>)<\/p><\/li><li class=\"\" data-start=\"2708\" data-end=\"2766\"><p class=\"\" data-start=\"2710\" data-end=\"2766\"><strong data-start=\"2710\" data-end=\"2728\">Spr\u00f8yteholder<\/strong> laget av egnet materiale som PEEK<\/p><\/li><li class=\"\" data-start=\"2767\" data-end=\"2834\"><p class=\"\" data-start=\"2769\" data-end=\"2834\"><strong data-start=\"2769\" data-end=\"2784\">Ladestift<\/strong>, fortrinnsvis polyacetal med kjerne av rustfritt st\u00e5l<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1e99e9 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"a1e99e9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 lekkasjetesting av spr\u00f8yter\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d45498c e-con-full e-flex e-con e-child\" data-id=\"d45498c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-91d25ab elementor-widget elementor-widget-heading\" data-id=\"91d25ab\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Vedlegg C1 Testprosedyre<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-922228a elementor-widget elementor-widget-text-editor\" data-id=\"922228a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2858\" data-end=\"2884\"><strong data-start=\"2858\" data-end=\"2882\">1. Klargj\u00f8r testpr\u00f8ver<br \/><\/strong><span style=\"font-size: 16px;\">Unng\u00e5 \u00e5 forh\u00e5ndsteste st\u00f8t. Inspiser hver spr\u00f8yte og holder visuelt for skader.<\/span><\/p><p class=\"\" data-start=\"2975\" data-end=\"2986\"><strong data-start=\"2975\" data-end=\"2984\">2. Oppsett av testmaskin<br \/><\/strong><span style=\"font-size: 16px;\">Plasser spr\u00f8ytehylsen i holderen. Rett inn ladestiften n\u00e6r spr\u00f8ytens skulder i henhold til <\/span><strong style=\"font-size: 16px;\" data-start=\"3091\" data-end=\"3105\">Figur C.2<\/strong><span style=\"font-size: 16px;\"> av ISO-standarden.<\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c20220 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"1c20220\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"451\" height=\"297\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Annex-C1.png\" class=\"attachment-large size-large wp-image-2064\" alt=\"ISO 11040-4 Annex C1 motstand mot flensbrudd\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Annex-C1.png 451w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Annex-C1-300x198.png 300w\" sizes=\"(max-width: 451px) 100vw, 451px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bc0e73 elementor-widget elementor-widget-text-editor\" data-id=\"0bc0e73\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3131\" data-end=\"3151\"><strong data-start=\"3131\" data-end=\"3149\">3. Testgjennomf\u00f8ring<\/strong><\/p><ul><li data-start=\"3131\" data-end=\"3151\">Still inn maskinens hastighet til <strong data-start=\"3182\" data-end=\"3196\">100 mm\/min<\/strong> (eller i henhold til avtale).<\/li><li data-start=\"3131\" data-end=\"3151\">Start testen og p\u00e5f\u00f8r kraft til flensen brekker.<\/li><li data-start=\"3131\" data-end=\"3151\">Rekord <strong style=\"font-size: 16px;\" data-start=\"3302\" data-end=\"3328\">kraft vs. forskyvning<\/strong><span style=\"font-size: 16px;\"> for \u00e5 lage en kurve.<\/span><\/li><\/ul><p class=\"\" data-start=\"3131\" data-end=\"3151\"><strong data-start=\"3352\" data-end=\"3369\">4. Analyse av data<br \/><\/strong>Identifiser toppkraften fra kurven - denne verdien representerer <em data-start=\"3442\" data-end=\"3470\">motstand mot flensbrudd<\/em>.<\/p><p class=\"\" data-start=\"3478\" data-end=\"3493\"><strong data-start=\"3478\" data-end=\"3491\">5. Rapportering<br \/><\/strong><span style=\"font-size: 16px;\">Inkluder testhastighet, antall pr\u00f8ver, toppverdier og eventuelle avvik. S\u00f8rg for at dokumentasjonen oppfyller ISO-sporbarhetskravene.<\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9006f3 elementor-widget elementor-widget-heading\" data-id=\"a9006f3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Spr\u00f8ytetester fra Cell Instruments<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e501b92 e-con-full e-flex e-con e-child\" data-id=\"e501b92\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7a2147d e-con-full e-flex e-con e-child\" data-id=\"7a2147d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-67dcd66 elementor-widget elementor-widget-heading\" data-id=\"67dcd66\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Spr\u00f8ytetestmaskinens viktigste fordeler<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb2553c elementor-widget elementor-widget-text-editor\" data-id=\"fb2553c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"4049\" data-end=\"4092\">Kompatibel med spr\u00f8ytespesifikke armaturer<\/li><li data-start=\"4049\" data-end=\"4092\">Grafisk plotting av kraft-forskyvning i sanntid<\/li><li data-start=\"4049\" data-end=\"4092\">Justerbare hastigheter og belastningsomr\u00e5der<\/li><li data-start=\"4049\" data-end=\"4092\">Innebygd mikroskriver og RS232-port (tilleggsutstyr) for s\u00f8ml\u00f8s dataeksport<\/li><\/ul><p class=\"\" data-start=\"4258\" data-end=\"4427\">Systemets modularitet gj\u00f8r det ideelt for selskaper som driver med omfattende <em data-start=\"4336\" data-end=\"4353\">spr\u00f8ytetesting<\/em>, inkludert <em data-start=\"4365\" data-end=\"4393\">motstand mot flensbrudd<\/em> og andre mekaniske evalueringer.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9b6dbd6 e-con-full e-flex e-con e-child\" data-id=\"9b6dbd6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c4684f elementor-widget elementor-widget-heading\" data-id=\"2c4684f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Beste praksis for spr\u00f8ytetestmaskiner<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f42b687 elementor-widget elementor-widget-text-editor\" data-id=\"f42b687\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"4495\" data-end=\"4556\"><strong data-start=\"4495\" data-end=\"4526\">Bruk h\u00f8yfrekvent pr\u00f8vetaking<\/strong> (\u2265500 Hz) for toppn\u00f8yaktighet<\/li><li data-start=\"4495\" data-end=\"4556\"><strong style=\"font-size: 16px;\" data-start=\"4559\" data-end=\"4584\">Verifiser testjusteringen<\/strong><span style=\"font-size: 16px;\"> f\u00f8r hver kj\u00f8ring for \u00e5 unng\u00e5 feilavlesninger<\/span><\/li><li data-start=\"4495\" data-end=\"4556\"><strong style=\"font-size: 16px;\" data-start=\"4629\" data-end=\"4655\">Skift ut slitte komponenter<\/strong><span style=\"font-size: 16px;\"> (lastestift, holder) regelmessig for \u00e5 opprettholde konsistensen<\/span><\/li><li data-start=\"4495\" data-end=\"4556\"><strong style=\"font-size: 16px;\" data-start=\"4716\" data-end=\"4739\">Dokumenter alt<\/strong><span style=\"font-size: 16px;\">selv sm\u00e5 avvik, for \u00e5 forbedre sporbarheten<\/span><\/li><li data-start=\"4495\" data-end=\"4556\"><strong style=\"font-size: 16px;\" data-start=\"4792\" data-end=\"4822\">Samarbeid med kundene<\/strong><span style=\"font-size: 16px;\"> \u00e5 bli enige om testhastigheter og kalibrering av utstyr<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20579e3 elementor-widget elementor-widget-text-editor\" data-id=\"20579e3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4897\" data-end=\"5170\">Testing av flensbruddmotstand er ikke bare en avkrysningsboks for samsvar - det er en viktig del av produktkvalitetssikringen for spr\u00f8yteprodusenter. Ved \u00e5 tilpasse testpraksisen til <strong data-start=\"5075\" data-end=\"5099\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Vedlegg C1<\/strong>kan du sikre produktets holdbarhet, sikkerhet og godkjenning fra myndighetene.<\/p><p class=\"\" data-start=\"5172\" data-end=\"5418\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/nb\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5172\" data-end=\"5192\">Cell Instruments<\/strong><\/a> er din betrodde partner n\u00e5r det gjelder \u00e5 oppn\u00e5 fremragende testing. V\u00e5re <strong>Spr\u00f8ytetester<\/strong>\u00a0bidrar til \u00e5 effektivisere arbeidsflyten for spr\u00f8ytetesting, samtidig som den leverer n\u00f8yaktigheten og samsvaret som kreves av moderne standarder i helsevesenet.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3e233b elementor-widget elementor-widget-text-editor\" data-id=\"b3e233b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\">La oss hjelpe deg p\u00e5 veien mot produkter med h\u00f8y ytelse og som er i samsvar med regelverket.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Flange Breakage Resistance ISO 11040-4 Annex C1 Flange breakage resistance is a critical quality attribute in prefilled syringe manufacturing. This test determines the mechanical strength of the syringe barrel\u2019s flange\u2014the portion that must withstand applied forces during clinical use. As healthcare regulations tighten globally, meeting the mechanical performance standards outlined in ISO 11040-4 Annex C1 [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2059","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/nb\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Flange Breakage Resistance ISO 11040-4 Annex C1 Flange breakage resistance is a critical quality attribute in prefilled syringe manufacturing. This test determines the mechanical strength of the syringe barrel\u2019s flange\u2014the portion that must withstand applied forces during clinical use. As healthcare regulations tighten globally, meeting the mechanical performance standards outlined in ISO 11040-4 Annex C1&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/posts\/2059","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/comments?post=2059"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/posts\/2059\/revisions"}],"predecessor-version":[{"id":2072,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/posts\/2059\/revisions\/2072"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/media?parent=2059"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/categories?post=2059"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/nb\/wp-json\/wp\/v2\/tags?post=2059"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}