{"id":2583,"date":"2026-03-30T02:14:28","date_gmt":"2026-03-30T02:14:28","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2583"},"modified":"2026-03-30T02:14:31","modified_gmt":"2026-03-30T02:14:31","slug":"hydrolytic-resistance-test-for-glass-containers","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/lv\/hydrolytic-resistance-test-for-glass-containers\/","title":{"rendered":"Stikla trauku hidrol\u012btisk\u0101s iztur\u012bbas tests: t\u0101 noz\u012bmes izpratne un ISO standarti"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Ievads stikla trauku hidrol\u012btisk\u0101s iztur\u012bbas test\u0113\u0161an\u0101<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Port\u0101ls <strong>stikla trauku hidrol\u012btisk\u0101s iztur\u012bbas tests<\/strong> ir b\u016btisks nov\u0113rt\u0113jums, ko izmanto, lai noteiktu stikla \u0137\u012bmisko iztur\u012bbu saskarei ar \u016bdeni vai \u016bdens \u0161\u0137\u012bdumiem. \u0160is tests nosaka stikla sp\u0113ju pretoties no\u0101rd\u012b\u0161an\u0101s vai iz\u0161\u0137\u012b\u0161anai, kas ir galvenais faktors stikla iepakojuma dro\u0161\u012bbas un ilgm\u016b\u017e\u012bbas nodro\u0161in\u0101\u0161an\u0101, jo \u012bpa\u0161i farm\u0101cijas, p\u0101rtikas un medic\u012bnas nozar\u0113s.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/lv\/understanding-hydrolytic-resistance-in-glass-containers\/\" target=\"_blank\" rel=\" noreferrer noopener\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/03\/Hydrolytic-Resistance-Test-for-Glass-Containers-ISO-719-and-ISO-720-Explained.webp\" alt=\"Stikla trauku hidrol\u012btisk\u0101s iztur\u012bbas p\u0101rbaude saska\u0146\u0101 ar standartiem ISO 719 un ISO 720 \u2014 skaidrojums\" class=\"wp-image-2585\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/03\/Hydrolytic-Resistance-Test-for-Glass-Containers-ISO-719-and-ISO-720-Explained.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/03\/Hydrolytic-Resistance-Test-for-Glass-Containers-ISO-719-and-ISO-720-Explained-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/03\/Hydrolytic-Resistance-Test-for-Glass-Containers-ISO-719-and-ISO-720-Explained-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/03\/Hydrolytic-Resistance-Test-for-Glass-Containers-ISO-719-and-ISO-720-Explained-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Kas ir hidrol\u012btisk\u0101 iztur\u012bba?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hidrol\u012btisk\u0101 iztur\u012bba ir stikla sp\u0113ja iztur\u0113t \u0137\u012bmisko iedarb\u012bbu saskarsm\u0113 ar \u016bdeni, jo \u012bpa\u0161i, ja tas tiek uzkars\u0113ts l\u012bdz noteikt\u0101m temperat\u016br\u0101m. Stikla trauki, ko izmanto medic\u012bnas vai p\u0101rtikas r\u016bpniec\u012bb\u0101, ir j\u0101pak\u013cauj hidrol\u012btisk\u0101s iztur\u012bbas testiem, lai p\u0101rliecin\u0101tos, ka tie ilgsto\u0161i saskaroties ar \u016bdeni neatbr\u012bvo kait\u012bgas vielas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 719: Stikla graudu hidrol\u012btisk\u0101 iztur\u012bba 98 \u00b0C temperat\u016br\u0101<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 719 ir standarts, kas nosaka metodes, k\u0101 p\u0101rbaud\u012bt <strong>stikla graudi\u0146u hidrol\u012btisk\u0101 iztur\u012bba 98 \u00b0C temperat\u016br\u0101<\/strong>. \u0160\u012b metode ir ide\u0101li piem\u0113rota maz\u0101k iztur\u012bgu stiklu, piem\u0113ram, n\u0101trija-kalcija stikla, test\u0113\u0161anai. Test\u0101 stikla graudi\u0146us (noteikt\u0101 izm\u0113r\u0101) 60 min\u016btes ekstrah\u0113 ar destil\u0113tu \u016bdeni 98 \u00b0C temperat\u016br\u0101, p\u0113c tam analiz\u0113jot s\u0101rmu jonu (galvenok\u0101rt n\u0101trija) izdal\u012b\u0161anos no stikla.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rezult\u0101tus izmanto, lai klasific\u0113tu stiklu atkar\u012bb\u0101 no t\u0101 hidrol\u012btisk\u0101s iztur\u012bbas. Stikliem ar augst\u0101ku iztur\u012bbu, piem\u0113ram, borosilik\u0101ta stiklam, var b\u016bt nepiecie\u0161ama at\u0161\u0137ir\u012bga p\u0101rbaudes metode, k\u0101 nor\u0101d\u012bts standart\u0101 ISO 720.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 720: Stikla graudu hidrol\u012btisk\u0101 iztur\u012bba 121 \u00b0C temperat\u016br\u0101<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 720 ir l\u012bdz\u012bga test\u0113\u0161anas metode, ta\u010du to veic augst\u0101k\u0101 temperat\u016br\u0101, proti, <strong>121 \u00b0C<\/strong>. \u0160is tests ir piem\u0113rot\u0101ks <strong>iztur\u012bgie stikla veidi<\/strong>, piem\u0113ram, borosilik\u0101ta stikls, ko t\u0101 iztur\u012bbas d\u0113\u013c bie\u017ei izmanto medic\u012bniskaj\u0101 un farmaceitiskaj\u0101 iepakojum\u0101. \u0160\u012b proced\u016bra ietver l\u012bdz\u012bgu ekstrakcijas procesu, ta\u010du at\u0161\u0137iras ar temperat\u016bru, ilgumu un p\u0101rbaud\u0101m\u0101 stikla tilpumu.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Hidrol\u012btisk\u0101s iztur\u012bbas p\u0101rbau\u017eu noz\u012bme<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hidrol\u012btisk\u0101s iztur\u012bbas p\u0101rbaude ir svar\u012bga, jo t\u0101 pal\u012bdz ra\u017eot\u0101jiem un kvalit\u0101tes kontroles speci\u0101listiem nodro\u0161in\u0101t, ka iepakojum\u0101 izmantotais stikls nerea\u0123\u0113 ar t\u0101 saturu. Jebk\u0101da stikla kvalit\u0101tes pasliktin\u0101\u0161an\u0101s var\u0113tu apdraud\u0113t z\u0101\u013cu vai p\u0101rtikas produktu integrit\u0101ti, radot ba\u017eas par dro\u0161\u012bbu un izraisot probl\u0113mas saist\u012bb\u0101 ar normat\u012bvaj\u0101m pras\u012bb\u0101m.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Iek\u0101rtas, ko izmanto hidrol\u012btisk\u0101s iztur\u012bbas p\u0101rbaud\u0113m<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Standarta hidrol\u012btisk\u0101s iztur\u012bbas test\u0113\u0161anas apr\u012bkojum\u0101 ietilpst svari, biuretes, pipetes un speci\u0101ls stikla trauks, tostarp autokl\u0101vi, lai nodro\u0161in\u0101tu prec\u012bzus apst\u0101k\u013cus, kas nepiecie\u0161ami prec\u012bzu rezult\u0101tu ieg\u016b\u0161anai. T\u0101di instrumenti k\u0101 <strong>\u2019Cell Instruments\u201c stikla graudu paraugu \u0146\u0113m\u0113js GHR-01A<\/strong> ir izstr\u0101d\u0101ti, lai atbilstu \u0161iem standartiem un nodro\u0161in\u0101tu stikla paraugu pareizu apstr\u0101di testa laik\u0101.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Port\u0101ls <strong>stikla trauku hidrol\u012btisk\u0101s iztur\u012bbas tests<\/strong> ir b\u016btiska proced\u016bra stikla \u0137\u012bmisk\u0101s iztur\u012bbas noteik\u0161anai. ISO 719 un ISO 720 standartu izpratne pal\u012bdz ra\u017eot\u0101jiem nodro\u0161in\u0101t, ka to produkti ir dro\u0161i un atbilst nozares normat\u012bviem. Izmantojot uzticamas test\u0113\u0161anas iek\u0101rtas, piem\u0113ram, <strong>\u2019Cell Instruments\u201c stikla graudu paraugu \u0146\u0113m\u0113js GHR-01A<\/strong>, uz\u0146\u0113mumi var nodro\u0161in\u0101t savu stikla iepakojuma materi\u0101lu kvalit\u0101ti un integrit\u0101ti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction to Hydrolytic Resistance Testing for Glass Containers The hydrolytic resistance test for glass containers is a crucial evaluation used to determine the chemical durability of glass when exposed to water or aqueous solutions. This test measures the ability of glass to resist degradation or dissolution, a key factor in ensuring the safety and longevity [&hellip;]<\/p>","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2583","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Editor","author_link":"https:\/\/www.pharmacopoeiatest.com\/lv\/author\/editor\/"},"uagb_comment_info":0,"uagb_excerpt":"Introduction to Hydrolytic Resistance Testing for Glass Containers The hydrolytic resistance test for glass containers is a crucial evaluation used to determine the chemical durability of glass when exposed to water or aqueous solutions. This test measures the ability of glass to resist degradation or dissolution, a key factor in ensuring the safety and longevity&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/posts\/2583","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/comments?post=2583"}],"version-history":[{"count":2,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/posts\/2583\/revisions"}],"predecessor-version":[{"id":2586,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/posts\/2583\/revisions\/2586"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/media?parent=2583"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/categories?post=2583"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/tags?post=2583"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}