{"id":2267,"date":"2025-07-21T07:08:11","date_gmt":"2025-07-21T07:08:11","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2267"},"modified":"2025-07-21T07:21:09","modified_gmt":"2025-07-21T07:21:09","slug":"ampoule-mechanical-strength-tester","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/lv\/ampoule-mechanical-strength-tester\/","title":{"rendered":"Ampu\u013cu meh\u0101nisk\u0101s iztur\u012bbas testeris saska\u0146\u0101 ar ISO 9187"},"content":{"rendered":"<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-fccd8bb\" id=\"introduction\" data-block-id=\"fccd8bb\"><h2 class=\"stk-block-heading__text\">Ievads<\/h2><\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-7387b849 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-uagb-container uagb-block-61ff3f36 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/lv\/category\/product\/ampoule-break-test\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp\" alt=\"ampulu meh\u0101nisk\u0101s iztur\u012bbas testeris\" class=\"wp-image-2280\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><figcaption class=\"wp-element-caption\">BST-01 Ampu\u013cu lau\u0161anas testeris <\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Prec\u012bzs nov\u0113rt\u0113jums <strong>ampulu meh\u0101nisk\u0101s iztur\u012bbas testeris <\/strong>ir \u013coti svar\u012bga farm\u0101cijas kvalit\u0101tes kontrol\u0113. Stikla ampul\u0101m, ko izmanto injic\u0113jamiem \u0161\u0137\u012bdumiem, j\u0101b\u016bt pietiekami iztur\u012bg\u0101m, lai saglab\u0101tu sterilit\u0101ti transport\u0113\u0161anas un uzglab\u0101\u0161anas laik\u0101, un vienlaikus pietiekami viegli atveram\u0101m bez p\u0101rm\u0113r\u012bga sp\u0113ka. ISO 9187 nosaka standartiz\u0113tas test\u0113\u0161anas proced\u016bras, lai nov\u0113rt\u0113tu \u0161\u012bs \u012bpa\u0161\u012bbas, jo \u012bpa\u0161i <strong>stikla ampulu lau\u0161anas sp\u0113ka m\u0113r\u012b\u0161ana<\/strong>. \u0160aj\u0101 rakst\u0101 ir aprakst\u012bta visa test\u0113\u0161anas proced\u016bra, izmantojot <strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/lv\/category\/product\/ampoule-break-test\/\">BST-01 <strong>Ampu\u013cu meh\u0101nisk\u0101s iztur\u012bbas testeris<\/strong><\/a><\/strong> no Cell Instruments, nodro\u0161inot atbilst\u012bbu normat\u012bvajiem aktiem un produktu dro\u0161\u012bbu.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-2c9d7c5\" id=\"breaking-force-measurement-for-glass-ampoules-using-bst-01-ampoule-tester\" data-block-id=\"2c9d7c5\"><h2 class=\"stk-block-heading__text\">Stikla ampulu lau\u0161anas sp\u0113ka m\u0113r\u012b\u0161ana, izmantojot BST-01 ampulu testeri<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P\u0101rr\u0101vuma sp\u0113ks<\/strong> ir ampulu meh\u0101nisk\u0101s integrit\u0101tes galvenais parametrs. ISO 9187-1:2010 un ISO 9187-2 nosaka stingrus krit\u0113rijus \u0161\u012b sp\u0113ka m\u0113r\u012b\u0161anai ampulas sa\u0161aurin\u0101jum\u0101, kas parasti ir mar\u0137\u0113ts ar keramikas gredzenu vai kr\u0101sainu pigmentu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Port\u0101ls <strong>BST-01 <strong>Ampu\u013cu meh\u0101nisk\u0101s iztur\u012bbas testeris<\/strong><\/strong> no Cell Instruments ir \u012bpa\u0161i izstr\u0101d\u0101ts \u0161im nol\u016bkam. Tas nodro\u0161ina <strong>prec\u012bzi un atk\u0101rtojami sp\u0113ka m\u0113r\u012bjumi<\/strong>saska\u0146\u0101 ar <strong>ISO 7500-1<\/strong> un <strong>ISO 9187<\/strong> specifik\u0101cijas. BST-01 ar kontrol\u0113tu testa \u0101trumu 10 mm\/min un 200 N sp\u0113ka diapazonu nodro\u0161ina uzticamus rezult\u0101tus kvalit\u0101tes kontroles laboratorij\u0101m un ra\u017eo\u0161anas uz\u0146\u0113mumiem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">BST-01 galven\u0101s funkcijas:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Piln\u012bb\u0101 atbilst ISO 9187 testa metodei<\/li>\n\n\n\n<li>Integr\u0113ta stiepes sp\u0113ka m\u0113r\u012b\u0161anas sist\u0113ma<\/li>\n\n\n\n<li>Programm\u0113jams \u0101trums un datu re\u0123istr\u0113\u0161ana<\/li>\n\n\n\n<li>Ide\u0101li piem\u0113rots <strong>stikla ampulu lau\u0161anas sp\u0113ka m\u0113r\u012b\u0161ana<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">BST-01 testera izmanto\u0161ana ne tikai uzlabo efektivit\u0101ti, bet ar\u012b pal\u012bdz noteikt <strong>nekonsekventa atkv\u0113lin\u0101\u0161ana<\/strong> vai <strong>v\u0101ja hidrol\u012btisk\u0101 iztur\u012bba<\/strong>, kas var\u0113tu apdraud\u0113t pacientu dro\u0161\u012bbu.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-66f05dd\" id=\"a-href-https-www-pharmacopoeiatest-com-iso-9187-1-iso-9187-a-standards-technical-testing-guidelines\" data-block-id=\"66f05dd\"><h2 class=\"stk-block-heading__text\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/lv\/iso-9187-1\/\">ISO 9187<\/a> Standarti: Tehnisk\u0101s test\u0113\u0161anas vadl\u012bnijas<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 9187 apraksta metodolo\u0123iju un pie\u0146em\u0161anas krit\u0113rijus, lai nov\u0113rt\u0113tu <strong>ampulu meh\u0101nisk\u0101 iztur\u012bba<\/strong>. Zem\u0101k ir uzskait\u012bti kritiski elementi, kas jums j\u0101iev\u0113ro:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Hidrol\u012btisk\u0101 iztur\u012bba<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ampul\u0101m j\u0101atbilst <strong>ISO 4802 HC1<\/strong> hidrol\u012btisk\u0101s iztur\u012bbas klase, kas nodro\u0161ina iek\u0161\u0113j\u0101s virsmas iztur\u012bbu pret \u016bdens \u0161\u0137\u012bdumiem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Atkaus\u0113\u0161anas kvalit\u0101te<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ampul\u0101s nedr\u012bkst b\u016bt redzama optisk\u0101 aizture, kas p\u0101rsniedz <strong>50 nm\/mm stikla biezums<\/strong>. Nepareiza r\u016bd\u012b\u0161ana palielina iek\u0161\u0113jo spriegumu, kas var izrais\u012bt l\u016bzumus apstr\u0101des vai transport\u0113\u0161anas laik\u0101.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">P\u0101rr\u0101vuma sp\u0113ka testa proced\u016bra<\/h3>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-dda3e97\" data-block-id=\"dda3e97\"><p class=\"stk-block-text__text\">    <strong>1.Apar\u0101ts:<\/strong> Izmantojiet stiepes testeri, kas atbilst <strong>ISO 7500-1<\/strong>, piem\u0113ram. <strong>BST-01 Ampu\u013cu meh\u0101nisk\u0101s iztur\u012bbas testeris<\/strong>.<br>    <strong>2.Testa \u0101trums:<\/strong> 10 mm\/min vai ekvivalents 20 N\/s jaudas \u0101trums.<br>    <strong>3.Force diapazons:<\/strong> Vismaz 200 N.<br>    <strong>4.Parauga sagatavo\u0161ana:<\/strong><br>             St\u0101voklis pie <strong>20 \u00b1 5 \u00b0C<\/strong>.<br>             Atlasiet paraugus atbilsto\u0161i <strong>ISO 2859-1<\/strong>, p\u0101rbaudes l\u012bmenis S-4.<br>    <strong>5.Uzst\u0101d\u012b\u0161ana:<\/strong><br>            Novietojiet ampulu starp diviem stie\u0146iem.<br>            Pielietojiet sp\u0113ku 90\u00b0 le\u0146\u0137\u012b pret t\u0101 asi.<br>            L\u016bzumiem j\u0101b\u016bt t\u012briem un re\u0123istr\u0113tiem ar sp\u0113ku.<\/p><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">P\u0101rr\u0101vuma punkta st\u0101voklis un stabilit\u0101te (ISO 9187-2)<\/h3>\n\n\n\n<figure class=\"wp-block-embed alignright is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"ISO 9187-1 ampulu lau\u0161anas testeris BST-01\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/fL78KBZwj3g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-74b8b2e\" data-block-id=\"74b8b2e\"><p class=\"stk-block-text__text\">                                               Ar kr\u0101su apz\u012bm\u0113tajam l\u016bzuma punktam j\u0101b\u016bt <strong>centr\u0113ta \u00b11 mm<\/strong>.<br>                                               Tam ir j\u0101iztur:<br>                                                   <strong>30 min\u016btes 120 \u00b0C temperat\u016br\u0101<\/strong>, p\u0113c tam iegremd\u0113jot <strong>30 \u00b0C \u016bdens<\/strong><br>                                                   <strong>Steriliz\u0101cijas cikli un t\u012br\u012b\u0161anas \u0161\u0137\u012bdin\u0101t\u0101ji<\/strong><br>                                               \u0160o nor\u0101d\u012bjumu neiev\u0113ro\u0161anas rezult\u0101t\u0101 var rasties p\u0101rm\u0113r\u012bgs lau\u0161anas sp\u0113ks, kas var padar\u012bt ampulu nedro\u0161u vai neatbilsto\u0161u pras\u012bb\u0101m.<\/p><\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-d535f6f\" id=\"why-mechanical-strength-testing-matters\" data-block-id=\"d535f6f\"><h2 class=\"stk-block-heading__text\">                K\u0101p\u0113c meh\u0101nisk\u0101s iztur\u012bbas p\u0101rbaude ir svar\u012bga<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Veicot <strong>ampulu meh\u0101nisk\u0101s iztur\u012bbas tests<\/strong> nav tikai regulas pie\u0146em\u0161ana. T\u0101 nodro\u0161ina:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Pacientu dro\u0161\u012bba:<\/strong> nov\u0113r\u0161 stikla da\u013ci\u0146u vai sp\u0113c\u012bgu l\u016bzumu ra\u0161anos.<\/li>\n\n\n\n<li><strong>Ra\u017eo\u0161anas konsekvence:<\/strong> agr\u012bna tr\u016bkumu atkl\u0101\u0161ana.<\/li>\n\n\n\n<li><strong>Atbilst\u012bba ties\u012bbu aktiem:<\/strong> izvair\u012b\u0161an\u0101s no noraid\u012bjumiem un atsaukumiem<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Re\u0101ls piem\u0113rs:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vado\u0161\u0101 farm\u0101cijas r\u016bpn\u012bca, kas izmanto BST-01, sasniedza <strong>30% samazin\u0101jums<\/strong> ar ampulu boj\u0101jumiem saist\u012bto s\u016bdz\u012bbu skaits p\u0113c ISO 9187 pras\u012bb\u0101m atbilsto\u0161u testu standartiz\u0113\u0161anas.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-25932c4\" id=\"choosing-the-right-ampoule-mechanical-strength-tester\" data-block-id=\"25932c4\"><h2 class=\"stk-block-heading__text\">Pareiz\u0101 ampulu meh\u0101nisk\u0101s iztur\u012bbas testera izv\u0113le.<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Cell Instruments specializ\u0113jas augstas precizit\u0101tes meh\u0101nisko test\u0113\u0161anas sist\u0113mu ra\u017eo\u0161an\u0101. . <strong>BST-01 Ampu\u013cu meh\u0101nisk\u0101s iztur\u012bbas testeris<\/strong> ir optimiz\u0113ta <strong>ampulu meh\u0101nisk\u0101s iztur\u012bbas tests<\/strong> un atbalsta automatiz\u0101ciju, datu izsekojam\u012bbu un operatora lieto\u0161anas \u0113rtumu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ar gadu desmitiem ilgu pieredzi <strong>medic\u012bnisko ier\u012b\u010du un farmaceitisk\u0101 iepakojuma test\u0113\u0161ana<\/strong>, Cell Instruments pied\u0101v\u0101 piel\u0101gotus risin\u0101jumus:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Injic\u0113jamo ampulu kvalit\u0101tes kontrole<\/li>\n\n\n\n<li>Materi\u0101la raksturojums<\/li>\n\n\n\n<li>Piel\u0101gotas automatiz\u0113tas testu konfigur\u0101cijas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ja j\u016bsu kvalit\u0101tes kontroles darbpl\u016bsma ietver stikla ampulas, BST-01 nodro\u0161ina nesal\u012bdzin\u0101mu <strong>precizit\u0101te, atk\u0101rtojam\u012bba un atbilst\u012bba<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-cea0f97\" id=\"conclusion\" data-block-id=\"cea0f97\"><h2 class=\"stk-block-heading__text\">Secin\u0101jums<\/h2><\/div>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-08e63b8\" data-block-id=\"08e63b8\"><style>.stk-08e63b8{margin-bottom:0px !important}.stk-08e63b8 .stk-block-text__text{text-shadow:none !important}<\/style><p class=\"stk-block-text__text\">Ampulu meh\u0101nisk\u0101s iztur\u012bbas nodro\u0161in\u0101\u0161ana ir b\u016btiska farmaceitiskajai integrit\u0101tei un pacientu dro\u0161\u012bbai. Iev\u0113rojot <a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>ISO 9187<\/strong> <\/a>standartus un izmantojot modernas iek\u0101rtas, piem\u0113ram, <strong>BST-01 Ampu\u013cu meh\u0101nisk\u0101s iztur\u012bbas testeris<\/strong>, ra\u017eot\u0101ji var dro\u0161i p\u0101rbaud\u012bt <strong>stikla ampulu lau\u0161anas sp\u0113ka m\u0113r\u012b\u0161ana<\/strong>. Prec\u012bza test\u0113\u0161ana ne tikai garant\u0113 produktu kvalit\u0101ti, bet ar\u012b veicina atbilst\u012bbu normat\u012bvajiem aktiem un klientu uztic\u012bbu.<br>Laboratorij\u0101m un ra\u017eot\u0101jiem, kas mekl\u0113 ISO pras\u012bb\u0101m atbilsto\u0161us un uzticamus test\u0113\u0161anas risin\u0101jumus, <strong>Cell Instruments' BST-01<\/strong> ir p\u0101rbaud\u012bta izv\u0113le, lai atbalst\u012btu j\u016bsu ampulu test\u0113\u0161anas programmu.<\/p><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Prec\u012bzs ampulu meh\u0101nisk\u0101s iztur\u012bbas testera nov\u0113rt\u0113jums ir \u013coti svar\u012bgs farm\u0101cijas kvalit\u0101tes kontrol\u0113. Stikla ampul\u0101m, ko izmanto injic\u0113jamiem \u0161\u0137\u012bdumiem, j\u0101b\u016bt pietiekami stipr\u0101m, lai saglab\u0101tu sterilit\u0101ti transport\u0113\u0161anas un uzglab\u0101\u0161anas laik\u0101, un vienlaikus pietiekami viegli atveram\u0101m bez p\u0101rm\u0113r\u012bga sp\u0113ka. ISO 9187 nosaka standartiz\u0113tas test\u0113\u0161anas proced\u016bras \u0161o \u012bpa\u0161\u012bbu nov\u0113rt\u0113\u0161anai, jo \u012bpa\u0161i stikla [...]<\/p>","protected":false},"author":1,"featured_media":2280,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2267","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"thumbnail":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp",150,150,true],"medium":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp",300,300,true],"medium_large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"1536x1536":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"2048x2048":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"trp-custom-language-flag":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",12,12,false]},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/lv\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Accurate evaluation of ampoule mechanical strength tester is critical in pharmaceutical quality control. Glass ampoules used for injectable solutions must be strong enough to maintain sterility during transportation and storage, yet easy enough to break open without excessive force. ISO 9187 provides standardized test procedures to assess these qualities, especially breaking force measurement for glass&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/posts\/2267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/comments?post=2267"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/posts\/2267\/revisions"}],"predecessor-version":[{"id":2300,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/posts\/2267\/revisions\/2300"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/media\/2280"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/media?parent=2267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/categories?post=2267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lv\/wp-json\/wp\/v2\/tags?post=2267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}