{"id":2610,"date":"2026-05-07T08:15:19","date_gmt":"2026-05-07T08:15:19","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2610"},"modified":"2026-05-07T08:46:47","modified_gmt":"2026-05-07T08:46:47","slug":"iso-8537","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/lt\/iso-8537\/","title":{"rendered":"ISO 8537"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2610\" class=\"elementor elementor-2610\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0662493 e-flex e-con-boxed e-con e-parent\" data-id=\"0662493\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fc37773 elementor-widget elementor-widget-heading\" data-id=\"fc37773\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8537 <br><small><small>Insulino \u0161virk\u0161to funkcionalumo bandymai<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-25d7b19 e-con-full e-flex e-con e-child\" data-id=\"25d7b19\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d257432 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"d257432\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"314\" data-end=\"683\">Standarte ISO 8537 nustatyti eksploataciniai ir bandym\u0173 reikalavimai, taikomi <strong data-start=\"378\" data-end=\"417\">steril\u016bs vienkartiniai insulino \u0161virk\u0161tai<\/strong>, su adatomis arba be j\u0173. \u0160is standartas skirtas \u0161virk\u0161t\u0173 saugumui, funkcionalumui, sandarumo savyb\u0117ms, dozavimo tikslumui ir eksploataciniam patikimumui. Gamintojai ir kokyb\u0117s tyrim\u0173 laboratorijos remiasi ISO 8537 standartu, siekdami patikrinti, ar \u0161virk\u0161tai klinikinio naudojimo metu veikia nuosekliai.<\/p><p data-start=\"685\" data-end=\"1021\">\u0160virk\u0161t\u0173 gamintojams atitiktis ISO 8537 standartui padidina gamini\u0173 patikimum\u0105, palengvina parai\u0161k\u0173 teikim\u0105 reguliavimo institucijoms ir suma\u017eina rizik\u0105, susijusi\u0105 su nuot\u0117kiu, st\u016bmoklio gedimu ar netiksliu dozavimu. Kokyb\u0117s kontrol\u0117s laboratorijoms \u0161is standartas numato patvirtintas proced\u016bras, skirtas \u0161virk\u0161t\u0173 veikimui vertinti kontroliuojamomis s\u0105lygomis.<\/p><p data-start=\"1023\" data-end=\"1207\">Kadangi insulino \u0161virk\u0161tams reikalingas tikslus vaisto \u012fvedimas ir patikimas sandarumas, <strong data-start=\"1105\" data-end=\"1138\">\u0161virk\u0161to funkcionalumo testavimas<\/strong> atlieka lemiam\u0105 vaidmen\u012f visame produkto k\u016brimo ir gamybos procese.<\/p><p data-start=\"1209\" data-end=\"1536\">\u201eCell Instruments\u201c si\u016blo specializuotas bandymo sistemas, skirtas \u0161virk\u0161t\u0173 gamintojams, medicinos prietais\u0173 laboratorijoms ir farmacijos pakuo\u010di\u0173 kokyb\u0117s u\u017etikrinimo komandoms. \u0160ie prietaisai leid\u017eia atlikti automatin\u012f j\u0117gos matavim\u0105, vakuumo sandarumo vertinim\u0105, sandarumo bandymus ir negyvosios erdv\u0117s analiz\u0119 pagal ISO 8537 metodikas.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b939f5 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"5b939f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"630\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes.webp\" class=\"attachment-full size-full wp-image-2613\" alt=\"ISO 8537. Insulino \u0161virk\u0161t\u0173 funkcionalumo bandymai\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes.webp 500w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes-238x300.webp 238w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes-10x12.webp 10w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77936bb elementor-widget elementor-widget-heading\" data-id=\"77936bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161t\u0173 funkcionalumo bandymai pagal ISO 8537 standart\u0105<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e0637a3 e-grid e-con-full e-con e-child\" data-id=\"e0637a3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d71bda6 elementor-widget elementor-widget-text-editor\" data-id=\"d71bda6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1586\" data-end=\"1769\">Standartas ISO 8537 apima \u012fvairius veikimo parametr\u0173 vertinimus, kuriais nustatoma, ar \u0161virk\u0161tas gali saugiai ir tiksliai veikti atliekant aspiracij\u0105 ir injekcij\u0105. Standartas apima \u0161iuos bandymus:<\/p><ul data-start=\"1771\" data-end=\"1938\"><li data-section-id=\"1oxsryt\" data-start=\"1771\" data-end=\"1802\">Oro nuot\u0117kis aspiracijos metu<\/li><li data-section-id=\"b62ksi\" data-start=\"1803\" data-end=\"1837\">Skys\u010dio nutek\u0117jimas esant sl\u0117giui<\/li><li data-section-id=\"143ln9z\" data-start=\"1838\" data-end=\"1862\">St\u016bmoklio veikimo j\u0117ga<\/li><li data-section-id=\"1trb4xg\" data-start=\"1863\" data-end=\"1879\">Sandariklio sandarumas<\/li><li data-section-id=\"77dvwg\" data-start=\"1880\" data-end=\"1899\">Negyvosios erdv\u0117s t\u016bris<\/li><li data-section-id=\"gfc932\" data-start=\"1900\" data-end=\"1938\">Adatos ir antgalio jungties nesandariumas<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d841201 elementor-widget elementor-widget-text-editor\" data-id=\"d841201\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1940\" data-end=\"1978\">\u0160ie bandymai padeda gamintojams \u012fvertinti:<\/p><ul data-start=\"1980\" data-end=\"2145\"><li data-section-id=\"4m7yx6\" data-start=\"1980\" data-end=\"2009\">St\u016bmoklio sandarumo nuoseklumas<\/li><li data-section-id=\"jtny4m\" data-start=\"2010\" data-end=\"2039\">Cilindro ir purk\u0161tuko sandarumas<\/li><li data-section-id=\"13p4qmo\" data-start=\"2040\" data-end=\"2067\">Tepimo efektyvumas<\/li><li data-section-id=\"1rxkfq7\" data-start=\"2068\" data-end=\"2093\">Vaisto doz\u0117s tiekimo tikslumas<\/li><li data-section-id=\"njxgtt\" data-start=\"2094\" data-end=\"2145\">\u0160virk\u0161to ir adatos sujungimo patikimumas<\/li><\/ul><p data-start=\"2147\" data-end=\"2270\">\u0160iuolaikin\u0117se laboratorijose vis da\u017eniau diegiamos automatizuotos bandym\u0173 sistemos, siekiant pagerinti rezultat\u0173 pakartojamum\u0105 ir suma\u017einti operatoriaus veiklos \u012ftak\u0105.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84b6ee2 elementor-widget elementor-widget-heading\" data-id=\"84b6ee2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161t\u0173 sandarumo bandymai pagal ISO 8537 standart\u0105<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d186872 elementor-widget elementor-widget-text-editor\" data-id=\"d186872\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2324\" data-end=\"2507\"><strong data-start=\"2324\" data-end=\"2348\">\u0160virk\u0161t\u0173 sandarumo bandymas<\/strong> yra viena i\u0161 svarbiausi\u0173 proced\u016br\u0173, apra\u0161yt\u0173 standarte ISO 8537. \u0160iame standarte vertinamas tiek oro, tiek skys\u010di\u0173 nuot\u0117kis skirtingomis sl\u0117gio s\u0105lygomis.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-47c3651 e-grid e-con-full e-con e-child\" data-id=\"47c3651\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-bd0c720 e-con-full e-flex e-con e-child\" data-id=\"bd0c720\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb605b0 elementor-widget elementor-widget-heading\" data-id=\"eb605b0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Oro nuot\u0117kis aspiracijos metu<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1310954 elementor-widget elementor-widget-text-editor\" data-id=\"1310954\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2544\" data-end=\"2684\">B priede ir F priede apra\u0161omi metodai, kaip vakuumin\u0117mis s\u0105lygomis nustatyti oro nuot\u0117k\u012f pro st\u016bmoklio sandarikl\u012f ir \u0161virk\u0161to antgalio jungtis.<\/p><p data-start=\"2686\" data-end=\"2719\">Paprastai proced\u016bra apima:<\/p><ol data-start=\"2721\" data-end=\"2926\"><li data-section-id=\"8f51yc\" data-start=\"2721\" data-end=\"2764\">\u0160virk\u0161to pripildymas distiliuotu vandeniu<\/li><li data-section-id=\"11xil91\" data-start=\"2765\" data-end=\"2822\">\u0160virk\u0161to prijungimas prie suderinamo k\u016bginio jungties elemento<\/li><li data-section-id=\"1w8sjai\" data-start=\"2823\" data-end=\"2852\">Neigiamo sl\u0117gio suk\u016brimas<\/li><li data-section-id=\"nzi51v\" data-start=\"2853\" data-end=\"2885\">Sl\u0117gio stabilumo steb\u0117jimas<\/li><li data-section-id=\"ad7xt5\" data-start=\"2886\" data-end=\"2926\">Pasteb\u0117jus nuot\u0117k\u012f arba burbuliuk\u0173 susidarym\u0105<\/li><\/ol><p data-start=\"2928\" data-end=\"3143\">Standarte ISO 8537 nurodytas vakuumo lygis yra <strong data-start=\"2965\" data-end=\"3010\">88 kPa \u017eemiau aplinkos atmosferos sl\u0117gio<\/strong> siekiant \u012fvertinti aspiracijos nuot\u0117k\u012f. Operatoriai stebi \u0161virk\u0161t\u0105, ar nesuma\u017e\u0117ja sl\u0117gis, ar nesusidaro burbuliukai ir ar neatsiskiria guminis kam\u0161telis.<\/p><p data-start=\"3145\" data-end=\"3164\">\u0160is testas patikrina:<\/p><ul data-start=\"3166\" data-end=\"3287\"><li data-section-id=\"31dbu3\" data-start=\"3166\" data-end=\"3189\">St\u016bmoklio sandariklio sandarumas<\/li><li data-section-id=\"10m5ixj\" data-start=\"3190\" data-end=\"3222\">Adatos jungties sandarumo charakteristikos<\/li><li data-section-id=\"17ziab\" data-start=\"3223\" data-end=\"3252\">Purk\u0161tuvo jungties patikimumas<\/li><li data-section-id=\"1way5n8\" data-start=\"3253\" data-end=\"3287\">Atsparumas nuot\u0117kiui \u012fkv\u0117pimo metu<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28726d3 e-con-full e-flex e-con e-child\" data-id=\"28726d3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4cf6b78 elementor-widget elementor-widget-heading\" data-id=\"4cf6b78\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vakuuminio sandarumo bandymai farmacijos srityje<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a833751 elementor-widget elementor-widget-text-editor\" data-id=\"a833751\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3339\" data-end=\"3513\">A <strong data-start=\"3341\" data-end=\"3376\">farmacinis vakuuminis sandarumo bandymas<\/strong> \u0160i proced\u016bra yra b\u016btina medicininiams \u0161virk\u0161tams, naudojamiems insulinui \u0161virk\u0161ti, nes net menkiausias nuot\u0117kis gali tur\u0117ti \u012ftakos doz\u0117s tikslumui ar sterilumui.<\/p><p data-start=\"3515\" data-end=\"3595\">\u201eCell Instruments\u201c rekomenduoja automatines vakuumini\u0173 sandarumo tikrinimo sistemas, kuriose yra:<\/p><ul data-start=\"3597\" data-end=\"3738\"><li data-section-id=\"le59d7\" data-start=\"3597\" data-end=\"3632\">Auk\u0161to tikslumo vakuumo reguliatoriai<\/li><li data-section-id=\"1jdfnmj\" data-start=\"3633\" data-end=\"3662\">Skaitmeninis sl\u0117gio steb\u0117jimas<\/li><li data-section-id=\"105a6xv\" data-start=\"3663\" data-end=\"3684\">Nuot\u0117kio silpn\u0117jimo analiz\u0117<\/li><li data-section-id=\"fca3b5\" data-start=\"3685\" data-end=\"3712\">Programuojamas i\u0161laikymo laikas<\/li><li data-section-id=\"cixp3u\" data-start=\"3713\" data-end=\"3738\">Duomen\u0173 registravimo programin\u0117 \u012franga<\/li><\/ul><p data-start=\"3740\" data-end=\"3896\">\u0160ios sistemos u\u017etikrina didesn\u012f pakartojamum\u0105, palyginti su rankiniais vakuumo vertinimo metodais, ir padeda laboratorijoms laikytis GMP bei ISO dokumentacijos reikalavim\u0173.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa6d2ef elementor-widget elementor-widget-heading\" data-id=\"fa6d2ef\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161t\u0173 sandarumo tikrinimo metodai<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0cbf91c elementor-widget elementor-widget-text-editor\" data-id=\"0cbf91c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3943\" data-end=\"4074\">Svetain\u0117 <strong data-start=\"3947\" data-end=\"3978\">\u0161virk\u0161to sandarumo patikrinimas<\/strong> \u012fvertina, ar suspaudimo ar siurbimo metu skystis ar oras gali prasiskverbti pro sandarinimo s\u0105sajas.<\/p><p data-start=\"4076\" data-end=\"4122\">ISO 8537 E priede daugiausia d\u0117mesio skiriama skys\u010di\u0173 nuot\u0117kiui:<\/p><ul data-start=\"4124\" data-end=\"4190\"><li data-section-id=\"z11dbz\" data-start=\"4124\" data-end=\"4138\">St\u016bmoklio sandarikliai<\/li><li data-section-id=\"1p89988\" data-start=\"4139\" data-end=\"4167\">\u0160virk\u0161to antgali\u0173 jungtys<\/li><li data-section-id=\"1aynqcu\" data-start=\"4168\" data-end=\"4190\">Adatos ir cilindro jungtys<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b34aa1c e-grid e-con-full e-con e-child\" data-id=\"b34aa1c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7afb7c0 elementor-widget elementor-widget-text-editor\" data-id=\"7afb7c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4365\" data-end=\"4389\">Atliekant bandymus, operatoriai sukuria vidin\u012f sl\u0117g\u012f, kurio dydis yra <strong data-start=\"4251\" data-end=\"4277\">300 kPa manometrinis sl\u0117gis<\/strong> ir i\u0161laikykite spaudim\u0105 30 sekund\u017ei\u0173, tuo pa\u010diu darydami \u0161onin\u0119 j\u0117g\u0105 st\u016bmokliui.<\/p><p data-start=\"4365\" data-end=\"4389\">\u0160i proced\u016bra \u012fvertina:<\/p><ul data-start=\"4391\" data-end=\"4508\"><li data-section-id=\"1k1t3bu\" data-start=\"4391\" data-end=\"4420\">Atsparumas sandariklio deformacijai<\/li><li data-section-id=\"vhj5a5\" data-start=\"4421\" data-end=\"4457\">Nuot\u0117kis esant \u0161oninei apkrovai<\/li><li data-section-id=\"1ubek41\" data-start=\"4458\" data-end=\"4485\">St\u016bmoklio jud\u0117jimo stabilumas<\/li><li data-section-id=\"tj03kp\" data-start=\"4486\" data-end=\"4508\">Ry\u0161io vientisumas<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5283d17 elementor-widget elementor-widget-text-editor\" data-id=\"5283d17\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4510\" data-end=\"4558\">Patikima sandarumo kontrol\u0117s sistema tur\u0117t\u0173 u\u017etikrinti:<\/p><ul data-start=\"4560\" data-end=\"4689\"><li data-section-id=\"1ogn8km\" data-start=\"4560\" data-end=\"4588\">Stabilus sl\u0117gio generavimas<\/li><li data-section-id=\"81fo7t\" data-start=\"4589\" data-end=\"4617\">Tikslus j\u0117gos taikymas<\/li><li data-section-id=\"vtwu91\" data-start=\"4618\" data-end=\"4647\">Nuot\u0117kio aptikimas realiuoju laiku<\/li><li data-section-id=\"198rl1a\" data-start=\"4648\" data-end=\"4689\">Auk\u0161tos skiriamosios gebos poslinkio steb\u0117jimas<\/li><\/ul><p data-start=\"4691\" data-end=\"4868\">\u201eCell Instruments\u201c si\u016blo sl\u0117gio nuot\u0117kio ir sandarumo patikrinimo sprendimus, tinkamus insulino \u0161virk\u0161tams, \u201eLuer\u201c sistemoms, farmacijos talpykloms ir medicinini\u0173 pakuo\u010di\u0173 gamybai.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1592e7 elementor-widget elementor-widget-heading\" data-id=\"d1592e7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161to slydimo j\u0117gos bandymas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86fac58 elementor-widget elementor-widget-text-editor\" data-id=\"86fac58\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4907\" data-end=\"5032\"><strong data-start=\"4907\" data-end=\"4938\">\u0160virk\u0161to slydimo j\u0117gos bandymas<\/strong> matuoja j\u0117g\u0105, reikaling\u0105 st\u016bmoklio jud\u0117jimui prad\u0117ti ir i\u0161laikyti skys\u010dio i\u0161st\u016bmimo metu.<\/p><p data-start=\"5034\" data-end=\"5176\">ISO 8537 C priede nurodyta, kaip naudoti mechanin\u012f bandymo \u012frengin\u012f, skirt\u0105 registruoti st\u016bmoklio veikimo j\u0117g\u0105, kai i\u0161 \u0161virk\u0161to i\u0161stumiamas vanduo.<\/p><p data-start=\"5178\" data-end=\"5206\">\u0160is testas paprastai vertina:<\/p><ul data-start=\"5208\" data-end=\"5305\"><li data-section-id=\"uhip3k\" data-start=\"5208\" data-end=\"5227\">I\u0161laisvinamoji j\u0117ga<\/li><li data-section-id=\"d3dsxi\" data-start=\"5228\" data-end=\"5241\">Slydimo j\u0117ga<\/li><li data-section-id=\"td0rt7\" data-start=\"5242\" data-end=\"5267\">Vidutin\u0117 veikimo j\u0117ga<\/li><li data-section-id=\"fqmeyx\" data-start=\"5268\" data-end=\"5305\">U\u017etikrinkite j\u0117gos pastovum\u0105 per vis\u0105 sm\u016bgio eig\u0105<\/li><\/ul><p data-start=\"5307\" data-end=\"5456\">Stabili slydimo j\u0117gos charakteristika yra itin svarbi, nes per didel\u0117 j\u0117ga gali suma\u017einti naudojimo patogum\u0105, o nepakankamas pasiprie\u0161inimas \u2013 pakenkti dozavimo kontrolei.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18cc935 elementor-widget elementor-widget-heading\" data-id=\"18cc935\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pagrindiniai veiksniai, darantys \u012ftak\u0105 sklendimo j\u0117gai<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d703620 e-grid e-con-full e-con e-child\" data-id=\"d703620\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c02067 elementor-widget elementor-widget-text-editor\" data-id=\"5c02067\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5497\" data-end=\"5556\">\u0160virk\u0161to slydimo savyb\u0117ms \u012ftakos turi keli parametrai:<\/p><ul data-start=\"5558\" data-end=\"5684\"><li data-section-id=\"1futzim\" data-start=\"5558\" data-end=\"5591\">Silikonin\u0117s tepimo med\u017eiagos pasiskirstymo tolygumas<\/li><li data-section-id=\"kuh4lo\" data-start=\"5592\" data-end=\"5617\">Guminio kam\u0161\u010dio med\u017eiaga<\/li><li data-section-id=\"53gmea\" data-start=\"5618\" data-end=\"5647\">Vamzd\u017eio matmen\u0173 tikslumas<\/li><li data-section-id=\"5t72bj\" data-start=\"5648\" data-end=\"5666\">Pavir\u0161iaus trintis<\/li><li data-section-id=\"198q7yk\" data-start=\"5667\" data-end=\"5684\">Adatos skersmuo<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9cd7bf elementor-widget elementor-widget-text-editor\" data-id=\"a9cd7bf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5686\" data-end=\"5745\">Profesionali \u0161virk\u0161to j\u0117gos matavimo sistema tur\u0117t\u0173 apimti:<\/p><ul data-start=\"5747\" data-end=\"5906\"><li data-section-id=\"ne6nqw\" data-start=\"5747\" data-end=\"5779\">Tiksli\u0173j\u0173 apkrovos jutikli\u0173 technologija<\/li><li data-section-id=\"1wxb0hx\" data-start=\"5780\" data-end=\"5811\">Jud\u0117jimo valdymas pastoviu grei\u010diu<\/li><li data-section-id=\"h51txm\" data-start=\"5812\" data-end=\"5847\">J\u0117gos ir poslinkio kreiv\u0117s analiz\u0117<\/li><li data-section-id=\"gjpujf\" data-start=\"5848\" data-end=\"5874\">Reguliuojami bandymo \u012frenginiai<\/li><li data-section-id=\"19afykk\" data-start=\"5875\" data-end=\"5906\">Kompiuterizuotas duomen\u0173 surinkimas<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef0db14 elementor-widget elementor-widget-text-editor\" data-id=\"ef0db14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>\u201eCell Instruments\u201c rekomenduoja universalias med\u017eiag\u0173 bandymo sistemas, kuriose \u012frengti specialiai pritaikyti \u0161virk\u0161t\u0173 laikikliai, skirti st\u016bmoklio j\u0117gos bandymams pagal ISO 8537 standart\u0105.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4d61be elementor-widget elementor-widget-heading\" data-id=\"c4d61be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u201eDead Space\u201c matavimas insulino \u0161virk\u0161tams<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2c205a elementor-widget elementor-widget-text-editor\" data-id=\"a2c205a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6115\" data-end=\"6239\"><strong data-start=\"6115\" data-end=\"6141\">Tu\u0161\u010dios erdv\u0117s matavimas<\/strong> nustato likutin\u012f skys\u010dio t\u016br\u012f, likus\u012f \u0161virk\u0161to viduje po to, kai st\u016bmoklis visi\u0161kai nuspaud\u017eiamas.<\/p><p data-start=\"6241\" data-end=\"6394\">Ma\u017ea negyvoji erdv\u0117 yra ypa\u010d svarbi insulino \u0161virk\u0161tams, nes vaisto liku\u010diai gali tur\u0117ti \u012ftakos dozavimo tikslumui ir didinti vaist\u0173 \u0161vaistym\u0105.<\/p><p data-start=\"6396\" data-end=\"6484\">ISO 8537 D priede apra\u0161omas gravimetrinis bandymo metodas, pagr\u012fstas vandens mas\u0117s matavimu.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3582f04 e-grid e-con-full e-con e-child\" data-id=\"3582f04\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-e4e0eef e-con-full e-flex e-con e-child\" data-id=\"e4e0eef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ee7135a elementor-widget elementor-widget-heading\" data-id=\"ee7135a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u201eDead Space\u201c matavimo proced\u016bra<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60271a8 elementor-widget elementor-widget-text-editor\" data-id=\"60271a8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6524\" data-end=\"6547\">Proced\u016bra apima:<\/p><ol data-start=\"6549\" data-end=\"6719\"><li data-section-id=\"5n54cf\" data-start=\"6549\" data-end=\"6578\">Tu\u0161\u010dios \u0161virk\u0161to sv\u0117rimas<\/li><li data-section-id=\"1po99wn\" data-start=\"6579\" data-end=\"6622\">\u0160virk\u0161to pripildymas distiliuotu vandeniu<\/li><li data-section-id=\"q59tts\" data-start=\"6623\" data-end=\"6656\">Vandens visi\u0161kas i\u0161leidimas<\/li><li data-section-id=\"1w7zx7c\" data-start=\"6657\" data-end=\"6682\">\u0160virk\u0161to pakartotinis pasv\u0117rimas<\/li><li data-section-id=\"1bth81y\" data-start=\"6683\" data-end=\"6719\">Sulaikyto vandens t\u016brio apskai\u010diavimas<\/li><\/ol><p data-start=\"6721\" data-end=\"6791\">Lik\u0119s vandens kiekis atitinka \u0161virk\u0161to negyvosios erdv\u0117s t\u016br\u012f.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c8b1057 e-con-full e-flex e-con e-child\" data-id=\"c8b1057\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c4747c elementor-widget elementor-widget-heading\" data-id=\"7c4747c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u201eDead Space\u201c testavimo svarba<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac04fa1 elementor-widget elementor-widget-text-editor\" data-id=\"ac04fa1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6831\" data-end=\"6883\">\u201eDead space\u201c matavimas padeda gamintojams \u012fvertinti:<\/p><ul data-start=\"6885\" data-end=\"6993\"><li data-section-id=\"1yt1bzi\" data-start=\"6885\" data-end=\"6902\">Dozavimo tikslumas<\/li><li data-section-id=\"to7kax\" data-start=\"6903\" data-end=\"6928\">Vaisto liku\u010di\u0173 i\u0161likimas organizme<\/li><li data-section-id=\"1uwyw95\" data-start=\"6929\" data-end=\"6962\">\u0160virk\u0161to konstrukcijos optimizavimas<\/li><li data-section-id=\"19wzgi9\" data-start=\"6963\" data-end=\"6993\">Adatos jungties konstrukcijos efektyvumas<\/li><\/ul><p data-start=\"6995\" data-end=\"7121\">\u201eCell Instruments\u201c gali pasi\u016blyti tiksli\u0173j\u0173 svarstykli\u0173 integravim\u0105 ir individualiai pritaikytas bandym\u0173 platformas, skirtas automatizuotai negyvosios erdv\u0117s analizei.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8195461 elementor-widget elementor-widget-heading\" data-id=\"8195461\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rekomenduojama bandymo \u012franga, u\u017etikrinanti atitikt\u012f ISO 8537 standartui<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-129d4b6 elementor-widget elementor-widget-text-editor\" data-id=\"129d4b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"7186\" data-end=\"7244\">Siekiant u\u017etikrinti atitikt\u012f ISO 8537 standartui, laboratorijose paprastai naudojama:<\/p><div class=\"TyagGW_tableContainer\"><div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"7246\" data-end=\"7579\"><thead data-start=\"7246\" data-end=\"7284\"><tr data-start=\"7246\" data-end=\"7284\"><th class=\"\" data-start=\"7246\" data-end=\"7258\" data-col-size=\"sm\">Testo u\u017eduotis<\/th><th class=\"\" data-start=\"7258\" data-end=\"7284\" data-col-size=\"sm\">Rekomenduojamas instrumentas<\/th><\/tr><\/thead><tbody data-start=\"7295\" data-end=\"7579\"><tr data-start=\"7295\" data-end=\"7342\"><td style=\"text-align: center;\" data-start=\"7295\" data-end=\"7320\" data-col-size=\"sm\">Vakuuminio sandarumo bandymas<\/td><td style=\"text-align: center;\" data-start=\"7320\" data-end=\"7342\" data-col-size=\"sm\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/lt\/vacuum-leak-tester-for-syringe-plunger-stopper-and-seal\/\">SLT-02 \u0161virk\u0161t\u0173 nuot\u0117kio testeris<\/a><\/td><\/tr><tr data-start=\"7402\" data-end=\"7456\"><td style=\"text-align: center;\" data-start=\"7402\" data-end=\"7427\" data-col-size=\"sm\">St\u016bmoklio veikimo j\u0117ga<\/td><td style=\"text-align: center;\" data-start=\"7427\" data-end=\"7456\" data-col-size=\"sm\"><p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/lt\/syringes-plunger-glide-force-tester\/\">SSR-01 \u0160virk\u0161to slankiojo pasiprie\u0161inimo testeris<\/a><\/p><\/td><\/tr><tr data-start=\"7457\" data-end=\"7513\"><td style=\"text-align: center;\" data-start=\"7457\" data-end=\"7479\" data-col-size=\"sm\">Negyvos erdv\u0117s analiz\u0117<\/td><td style=\"text-align: center;\" data-start=\"7479\" data-end=\"7513\" data-col-size=\"sm\">Gravimetrin\u0117 matavimo sistema<\/td><\/tr><tr data-start=\"7514\" data-end=\"7579\"><td style=\"text-align: center;\" data-start=\"7514\" data-end=\"7543\" data-col-size=\"sm\">Ry\u0161io sandarumo tikrinimas<\/td><td style=\"text-align: center;\" data-start=\"7543\" data-end=\"7579\" data-col-size=\"sm\"><div class=\"elementor-element elementor-element-9d87235 elementor-widget elementor-widget-heading\" data-id=\"9d87235\" data-element_type=\"widget\" data-widget_type=\"heading.default\"><div class=\"elementor-widget-container\"><p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/lt\/syringe-plunger-seal-integrity-tester\/\">SPPT-01 \u0160virk\u0161to teigiamo sl\u0117gio sandarumo testeris<\/a><\/p><\/div><\/div><\/td><\/tr><\/tbody><\/table><\/div><\/div><p data-start=\"7581\" data-end=\"7773\">\u201eCell Instruments\u201c si\u016blo individualiai pritaikytus automatizavimo sprendimus \u0161virk\u0161t\u0173 bandym\u0173 laboratorijoms, \u012fskaitant daugiapozicines sistemas, duomen\u0173 valdymo programin\u0119 \u012frang\u0105 ir integruotas kokyb\u0117s kontrol\u0117s platformas.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b08dc9a elementor-widget elementor-widget-heading\" data-id=\"b08dc9a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">DUK<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e8bf18 elementor-widget elementor-widget-text-editor\" data-id=\"3e8bf18\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>Kas yra ISO 8537?<\/strong><br \/>ISO 8537 \u2013 tai tarptautinis standartas, kuriame nustatyti reikalavimai ir bandym\u0173 metodai, taikomi steriliems vienkartiniams insulino \u0161virk\u0161tams su adatomis arba be j\u0173.<\/p><p><strong>Kas yra \u0161virk\u0161to sandarumo bandymas pagal ISO 8537 standart\u0105?<\/strong><br \/>\u0160virk\u0161to sandarumo bandymas skirtas \u012fvertinti oro ar skys\u010dio nuot\u0117k\u012f per st\u016bmoklio tarpiklius, \u0161virk\u0161to antgalius ir adatos jungtis vakuumo arba sl\u0117gio s\u0105lygomis.<\/p><p><strong>Kod\u0117l svarbu atlikti \u0161virk\u0161to slydimo j\u0117gos bandym\u0105?<\/strong><br \/>Slydimo j\u0117gos bandymas leid\u017eia patikrinti, ar st\u016bmoklis juda skland\u017eiai ir tolygiai, taip u\u017etikrinant tiksl\u0173 insulino \u012fvedim\u0105 ir tinkam\u0105 \u0161virk\u0161to naudojim\u0105.<\/p><p><strong>Kas yra \u0161virk\u0161to sandarumo patikrinimas?<\/strong><br \/>\u0160virk\u0161to sandarumo patikrinimas leid\u017eia nustatyti, ar sandarinimo s\u0105sajos u\u017ekerta keli\u0105 nuot\u0117kiui suspaudimo ir aspiracijos s\u0105lygomis.<\/p><p><strong>Kaip atliekamas tu\u0161\u010diosios erdv\u0117s matavimas?<\/strong><br \/>Tu\u0161\u010diosios erdv\u0117s matavimui naudojamas gravimetrinis metodas, kurio metu lyginama \u0161virk\u0161to mas\u0117 prie\u0161 ir po vandens i\u0161st\u016bmimo, siekiant nustatyti likusio skys\u010dio t\u016br\u012f.<\/p><p><strong>Kokiems tikslams naudojami \u0161ie prietaisai <a href=\"https:\/\/www.iso.org\/standard\/60510.html\" target=\"_blank\" rel=\"noopener\">ISO 8537<\/a> testavimas?<\/strong><br \/>Da\u017eniausiai naudojami prietaisai \u2013 tai vakuuminiai sandarumo tikrintuvai, universalios bandymo ma\u0161inos, sl\u0117gio kritimo sistemos ir gravimetriniai matavimo prietaisai.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 8537. Insulino \u0161virk\u0161t\u0173 funkcionalumo bandymai. Standartas ISO 8537 nustato sterili\u0173 vienkartini\u0173 insulino \u0161virk\u0161t\u0173, su adatomis arba be j\u0173, eksploatacinius ir bandym\u0173 reikalavimus. Standarte daugiausia d\u0117mesio skiriama \u0161virk\u0161t\u0173 saugumui, funkcionalumui, sandarumo savyb\u0117ms, dozavimo tikslumui ir eksploataciniam patikimumui. Gamintojai ir kokyb\u0117s laboratorijos taiko ISO 8537 standart\u0105, siekdami patikrinti, ar \u0161virk\u0161tai klinikinio naudojimo metu veikia nuosekliai. [\u2026]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2610","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/lt\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 8537 Syringe Functionality Testing for Insulin Syringe ISO 8537 specifies the performance and testing requirements for sterile single-use insulin syringes, with or without needles. The standard focuses on syringe safety, functionality, sealing performance, dosage accuracy, and operational reliability. Manufacturers and quality laboratories use ISO 8537 to verify that syringes perform consistently during clinical use.&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/comments?post=2610"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2610\/revisions"}],"predecessor-version":[{"id":2624,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2610\/revisions\/2624"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/media?parent=2610"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/categories?post=2610"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/tags?post=2610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}