{"id":2267,"date":"2025-07-21T07:08:11","date_gmt":"2025-07-21T07:08:11","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2267"},"modified":"2025-07-21T07:21:09","modified_gmt":"2025-07-21T07:21:09","slug":"ampoule-mechanical-strength-tester","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/lt\/ampoule-mechanical-strength-tester\/","title":{"rendered":"Ampuli\u0173 mechaninio stiprumo testeris pagal ISO 9187"},"content":{"rendered":"<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-fccd8bb\" id=\"introduction\" data-block-id=\"fccd8bb\"><h2 class=\"stk-block-heading__text\">\u012evadas<\/h2><\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-7387b849 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-uagb-container uagb-block-61ff3f36 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/lt\/category\/product\/ampoule-break-test\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp\" alt=\"ampul\u0117s mechaninio stiprumo testeris\" class=\"wp-image-2280\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><figcaption class=\"wp-element-caption\">BST-01 ampuli\u0173 tr\u016bkimo testeris <\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Tikslus \u012fvertinimas <strong>ampul\u0117s mechaninio stiprumo testeris <\/strong>yra labai svarbus farmacijos kokyb\u0117s kontrolei. Stiklo ampul\u0117s, naudojamos injekciniams tirpalams, turi b\u016bti pakankamai tvirtos, kad transportavimo ir saugojimo metu i\u0161laikyt\u0173 sterilum\u0105, ta\u010diau jas turi b\u016bti lengva atidaryti be didel\u0117s j\u0117gos. ISO 9187 pateikia standartizuotas bandym\u0173 proced\u016bras \u0161ioms savyb\u0117ms \u012fvertinti, ypa\u010d <strong>stiklini\u0173 ampuli\u0173 lau\u017eimo j\u0117gos matavimas<\/strong>. \u0160iame straipsnyje apra\u0161oma visa testavimo proced\u016bra naudojant <strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/lt\/category\/product\/ampoule-break-test\/\">BST-01 <strong>Ampuli\u0173 mechaninio stiprumo testeris<\/strong><\/a><\/strong> i\u0161 \"Cell Instruments\", u\u017etikrinant atitikt\u012f teis\u0117s akt\u0173 reikalavimams ir produkt\u0173 saug\u0105.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-2c9d7c5\" id=\"breaking-force-measurement-for-glass-ampoules-using-bst-01-ampoule-tester\" data-block-id=\"2c9d7c5\"><h2 class=\"stk-block-heading__text\">Stiklini\u0173 ampuli\u0173 lau\u017eimo j\u0117gos matavimas naudojant BST-01 ampuli\u0173 tester\u012f<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>L\u016b\u017eio j\u0117ga<\/strong> yra pagrindinis ampuli\u0173 mechaninio vientisumo parametras. ISO 9187-1:2010 ir ISO 9187-2 standartuose nustatyti grie\u017eti \u0161ios j\u0117gos matavimo kriterijai ties ampul\u0117s susiaur\u0117jimu, paprastai pa\u017eym\u0117tu keraminiu \u017eiedu arba spalvotu pigmentu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Svetain\u0117 <strong>BST-01 <strong>Ampuli\u0173 mechaninio stiprumo testeris<\/strong><\/strong> i\u0161 \"Cell Instruments\" yra specialiai sukurta \u0161iam tikslui. Jis suteikia <strong>tiksl\u016bs ir pakartojami j\u0117gos matavimai<\/strong>, pagal <strong>ISO 7500-1<\/strong> ir <strong>ISO 9187<\/strong> specifikacijos. Kontroliuojamas 10 mm\/min bandymo greitis ir 200 N j\u0117gos diapazonas u\u017etikrina patikimus rezultatus kokyb\u0117s kontrol\u0117s laboratorijose ir gamybos \u012fmon\u0117se.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pagrindin\u0117s BST-01 savyb\u0117s:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Visi\u0161kai atitinka ISO 9187 bandymo metod\u0105<\/li>\n\n\n\n<li>Integruota tempimo j\u0117gos matavimo sistema<\/li>\n\n\n\n<li>Programuojamas greitis ir duomen\u0173 registravimas<\/li>\n\n\n\n<li>Idealiai tinka <strong>stiklini\u0173 ampuli\u0173 lau\u017eimo j\u0117gos matavimas<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Naudojant BST-01 tester\u012f ne tik padid\u0117ja efektyvumas, bet ir padedama aptikti <strong>nenuoseklus atkaitinimas<\/strong> arba <strong>silpnas atsparumas hidroliz\u0117s poveikiui<\/strong>, o tai gali pakenkti pacient\u0173 saugai.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-66f05dd\" id=\"a-href-https-www-pharmacopoeiatest-com-iso-9187-1-iso-9187-a-standards-technical-testing-guidelines\" data-block-id=\"66f05dd\"><h2 class=\"stk-block-heading__text\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/lt\/iso-9187-1\/\">ISO 9187<\/a> Standartai: Technini\u0173 bandym\u0173 gair\u0117s<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 9187 apra\u0161o metodik\u0105 ir pri\u0117mimo kriterijus, skirtus \u012fvertinti <strong>mechaninis ampuli\u0173 atsparumas<\/strong>. Toliau pateikiami svarbiausi elementai, kuri\u0173 privalote laikytis:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Atsparumas hidroliz\u0117s poveikiui<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ampul\u0117s turi atitikti <strong>ISO 4802 HC1<\/strong> atsparumo hidroliz\u0117s poveikiui klas\u0117, u\u017etikrinanti vidinio pavir\u0161iaus patvarum\u0105 prie\u0161 vandeninius tirpalus.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Atkaitinimo kokyb\u0117<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ampuli\u0173 optinis sul\u0117t\u0117jimas netur\u0117t\u0173 vir\u0161yti <strong>50 nm\/mm stiklo storio<\/strong>. Netinkamas atkaitinimas padidina vidin\u012f \u012ftempim\u0105, d\u0117l kurio gali l\u016b\u017eti tvarkant ar transportuojant.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">L\u016b\u017eio j\u0117gos bandymo proced\u016bra<\/h3>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-dda3e97\" data-block-id=\"dda3e97\"><p class=\"stk-block-text__text\">    <strong>1.Aparatas:<\/strong> Naudokite tempimo tester\u012f, atitinkant\u012f <strong>ISO 7500-1<\/strong>, pvz. <strong>BST-01 ampuli\u0173 mechaninio stiprumo testeris<\/strong>.<br>    <strong>2.Testo greitis:<\/strong> 10 mm\/min arba lygiavert\u0117 20 N\/s galia.<br>    <strong>3.Force diapazonas:<\/strong> Ne ma\u017eiau kaip 200 N.<br>    <strong>4.M\u0117ginio paruo\u0161imas:<\/strong><br>             B\u016bkl\u0117 <strong>20 \u00b1 5 \u00b0C<\/strong>.<br>             Pasirinkite m\u0117ginius pagal <strong>ISO 2859-1<\/strong>, S-4 tikrinimo lygis.<br>    <strong>5.Nustatymas:<\/strong><br>            Pad\u0117kite ampul\u0119 tarp dviej\u0173 stryp\u0173.<br>            Veikiama j\u0117ga 90\u00b0 kampu jo a\u0161ies at\u017evilgiu.<br>            Sulau\u017eymas turi b\u016bti \u0161varus ir u\u017efiksuotas j\u0117ga.<\/p><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">L\u016b\u017eio ta\u0161ko pad\u0117tis ir stabilumas (ISO 9187-2)<\/h3>\n\n\n\n<figure class=\"wp-block-embed alignright is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"ISO 9187-1 ampul\u0117s tr\u016bkimo testeris BST-01\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/fL78KBZwj3g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-74b8b2e\" data-block-id=\"74b8b2e\"><p class=\"stk-block-text__text\">                                               Spalvomis pa\u017eym\u0117tas l\u016b\u017eio ta\u0161kas turi b\u016bti <strong>centruota \u00b11 mm<\/strong>.<br>                                               Ji turi b\u016bti atspari:<br>                                                   <strong>30 minu\u010di\u0173 120 \u00b0C temperat\u016broje<\/strong>, tada panardinimas \u012f <strong>30 \u00b0C vanduo<\/strong><br>                                                   <strong>Sterilizavimo ciklai ir valymo tirpikliai<\/strong><br>                                               Nesilaikant \u0161i\u0173 nurodym\u0173, gali b\u016bti naudojama per didel\u0117 lau\u017eimo j\u0117ga, tod\u0117l ampul\u0117 gali b\u016bti nesaugi arba neatitikti reikalavim\u0173.<\/p><\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-d535f6f\" id=\"why-mechanical-strength-testing-matters\" data-block-id=\"d535f6f\"><h2 class=\"stk-block-heading__text\">                Kod\u0117l svarbus mechaninio stiprumo bandymas<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Atlikimas <strong>ampul\u0117s mechaninio atsparumo bandymas<\/strong> tai ne tik reglamento pri\u0117mimas. Jis u\u017etikrina:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Pacient\u0173 sauga:<\/strong> apsaugo nuo stiklo daleli\u0173 ar stipraus sudau\u017eymo.<\/li>\n\n\n\n<li><strong>Gamybos nuoseklumas:<\/strong> ankstyvas tr\u016bkum\u0173 aptikimas<\/li>\n\n\n\n<li><strong>Atitiktis teis\u0117s aktams:<\/strong> i\u0161vengti atmetimo ir at\u0161aukimo.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Realaus pasaulio pavyzdys:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Viena i\u0161 pirmaujan\u010di\u0173 farmacijos gamykl\u0173, naudojanti BST-01, pasiek\u0117 <strong>30% suma\u017einimas<\/strong> skund\u0173 d\u0117l ampuli\u0173 sudu\u017eimo, standartizavus ISO 9187 standart\u0105 atitinkan\u010dius bandymus.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-25932c4\" id=\"choosing-the-right-ampoule-mechanical-strength-tester\" data-block-id=\"25932c4\"><h2 class=\"stk-block-heading__text\">Tinkamo ampuli\u0173 mechaninio stiprumo testerio pasirinkimas.<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\"Cell Instruments\" specializuojasi didelio tikslumo mechanini\u0173 bandym\u0173 sistemose. . <strong>BST-01 ampuli\u0173 mechaninio stiprumo testeris<\/strong> yra optimizuotas <strong>ampul\u0117s mechaninio atsparumo bandymas<\/strong> ir palaiko automatizavim\u0105, duomen\u0173 atsekamum\u0105 ir operatoriaus patogum\u0105.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De\u0161imtme\u010dius sukaupta patirtis <strong>medicinos prietais\u0173 ir vaist\u0173 pakuo\u010di\u0173 bandymai<\/strong>, \"Cell Instruments\" si\u016blo specialiai pritaikytus sprendimus:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Injekcini\u0173 ampuli\u0173 kokyb\u0117s kontrol\u0117<\/li>\n\n\n\n<li>Med\u017eiagos apib\u016bdinimas<\/li>\n\n\n\n<li>Pasirinktin\u0117s automatizuotos bandym\u0173 s\u0105rankos<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Jei j\u016bs\u0173 kokyb\u0117s kontrol\u0117s darbo eiga susijusi su stiklin\u0117mis ampul\u0117mis, BST-01 u\u017etikrina neprilygstam\u0105 <strong>tikslumas, pakartojamumas ir atitiktis<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-cea0f97\" id=\"conclusion\" data-block-id=\"cea0f97\"><h2 class=\"stk-block-heading__text\">I\u0161vada<\/h2><\/div>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-08e63b8\" data-block-id=\"08e63b8\"><style>.stk-08e63b8{margin-bottom:0px !important}.stk-08e63b8 .stk-block-text__text{text-shadow:none !important}<\/style><p class=\"stk-block-text__text\">Ampuli\u0173 mechaninio atsparumo u\u017etikrinimas yra labai svarbus farmacijos vientisumui ir pacient\u0173 saugai. Laikydamiesi <a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>ISO 9187<\/strong> <\/a>standartus ir naudojant pa\u017eangi\u0105 \u012frang\u0105, pvz. <strong>BST-01 ampuli\u0173 mechaninio stiprumo testeris<\/strong>, gamintojai gali dr\u0105siai patikrinti <strong>stiklini\u0173 ampuli\u0173 lau\u017eimo j\u0117gos matavimas<\/strong>. Tiksl\u016bs bandymai ne tik u\u017etikrina produkto kokyb\u0119, bet ir didina atitikt\u012f teis\u0117s akt\u0173 reikalavimams bei klient\u0173 pasitik\u0117jim\u0105.<br>Laboratorijoms ir gamintojams, ie\u0161kantiems ISO reikalavimus atitinkan\u010di\u0173 ir patikim\u0173 bandym\u0173 sprendim\u0173, <strong>\"Cell Instruments\" BST-01<\/strong> yra patikrintas pasirinkimas j\u016bs\u0173 ampuli\u0173 testavimo programai paremti.<\/p><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Tikslus ampuli\u0173 mechaninio stiprumo testerio \u012fvertinimas yra labai svarbus farmacijos kokyb\u0117s kontrolei. Stiklo ampul\u0117s, naudojamos injekciniams tirpalams, turi b\u016bti pakankamai tvirtos, kad transportavimo ir saugojimo metu i\u0161laikyt\u0173 sterilum\u0105, ta\u010diau pakankamai lengvai atsidaran\u010dios be didel\u0117s j\u0117gos. ISO 9187 pateikia standartizuotas bandym\u0173 proced\u016bras \u0161ioms savyb\u0117ms \u012fvertinti, ypa\u010d stiklo ampuli\u0173 tr\u016bkimo j\u0117gai matuoti.<\/p>","protected":false},"author":1,"featured_media":2280,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2267","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"thumbnail":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp",150,150,true],"medium":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp",300,300,true],"medium_large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"1536x1536":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"2048x2048":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"trp-custom-language-flag":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",12,12,false]},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/lt\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Accurate evaluation of ampoule mechanical strength tester is critical in pharmaceutical quality control. Glass ampoules used for injectable solutions must be strong enough to maintain sterility during transportation and storage, yet easy enough to break open without excessive force. ISO 9187 provides standardized test procedures to assess these qualities, especially breaking force measurement for glass&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/comments?post=2267"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2267\/revisions"}],"predecessor-version":[{"id":2300,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2267\/revisions\/2300"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/media\/2280"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/media?parent=2267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/categories?post=2267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/tags?post=2267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}