{"id":2105,"date":"2025-05-07T06:56:33","date_gmt":"2025-05-07T06:56:33","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2105"},"modified":"2025-05-07T06:56:34","modified_gmt":"2025-05-07T06:56:34","slug":"lla-collar-torque-resistance","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/lt\/lla-collar-torque-resistance\/","title":{"rendered":"LLA apykakl\u0117s atsparumas sukimo momentui"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2105\" class=\"elementor elementor-2105\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f46df2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f46df2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2444a elementor-widget elementor-widget-heading\" data-id=\"7b2444a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">LLA apykakl\u0117s atsparumas sukimo momentui<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edec19 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8edec19\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e4ea1f elementor-widget elementor-widget-heading\" data-id=\"0e4ea1f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 G4 priedas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3053d41 e-flex e-con-boxed e-con e-parent\" data-id=\"3053d41\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d4d20a elementor-widget elementor-widget-text-editor\" data-id=\"7d4d20a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"376\" data-end=\"978\">Vaist\u0173 gamyboje mechaninio i\u0161 anksto u\u017epildyt\u0173 \u0161virk\u0161t\u0173 vientisumo u\u017etikrinimas yra labai svarbus produkto saugai ir veikimui. Vienas i\u0161 svarbiausi\u0173 \u0161io vientisumo veiksni\u0173 yra <strong data-start=\"567\" data-end=\"599\">LLA apykakl\u0117s atsparumas sukimo momentui<\/strong>, kuriuo matuojamas Luerio u\u017erakto adapterio (LLA) apykakl\u0117s stiprumas veikiant sukimo momentui. \u0160i savyb\u0117 u\u017etikrina, kad apykakl\u0117 atlaikyt\u0173 sukimosi j\u0117g\u0105, kai medicinos personalas prijungia adatos stebules arba suderinamas jungtis. Atliekant \u0161\u012f bandym\u0105 pagal <em data-start=\"862\" data-end=\"875\">ISO 11040-4<\/em> ir <em data-start=\"880\" data-end=\"890\">G4 priedas<\/em> padeda gamintojams u\u017etikrinti atitikt\u012f teis\u0117s akt\u0173 reikalavimams ir tiekti saugius, funkcionalius gaminius.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0043965 elementor-widget elementor-widget-heading\" data-id=\"0043965\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">LLA apykakl\u0117s sukimo momento pasiprie\u0161inimas ir tai svarbu<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef59016 elementor-widget elementor-widget-text-editor\" data-id=\"ef59016\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"985\" data-end=\"1456\"><strong data-start=\"1047\" data-end=\"1079\">LLA apykakl\u0117s atsparumas sukimo momentui<\/strong> rei\u0161kia \u0161virk\u0161to Luerio u\u017erakto adapterio apykakl\u0117s atsparum\u0105 sukimuisi ar atsipalaidavimui, kai veikia sukimo momentas. Tai imituoja mechanin\u0119 \u012ftamp\u0105, kuri patiriama gydytojui prijungiant su Luer u\u017eraktu suderinam\u0105 prietais\u0105. Jei atsparumas sukimo momentui sutrinka, gali atsirasti nuot\u0117kis, netinkamas vaisto vartojimas arba u\u017eter\u0161imas - rimta rizika klinikin\u0117je aplinkoje.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77afa8a elementor-widget elementor-widget-heading\" data-id=\"77afa8a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161t\u0173 bandymo standartas - ISO 11040-4 G4 priedas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f4cc74 e-con-full e-flex e-con e-child\" data-id=\"9f4cc74\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0879ad7 elementor-widget elementor-widget-text-editor\" data-id=\"0879ad7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1463\" data-end=\"1902\">Svetain\u0117 <strong data-start=\"1525\" data-end=\"1540\">ISO 11040-4<\/strong> standartas, pavadintas <em data-start=\"1558\" data-end=\"1673\">I\u0161 anksto u\u017epildyti \u0161virk\u0161tai. 4 dalis. Stiklin\u0117s statin\u0117s \u0161virk\u0161\u010diamiesiems vaistams ir sterilizuoti surenkamieji \u0161virk\u0161tai, paruo\u0161ti u\u017epildymui<\/em>, i\u0161d\u0117styti grie\u017eti bandym\u0173 metodai, kuriais u\u017etikrinamas gaminio patikimumas. <em data-start=\"1737\" data-end=\"1747\">G4 priedas<\/em> i\u0161samiai apra\u0161ytas vertinimo metodas <strong data-start=\"1794\" data-end=\"1826\">LLA apykakl\u0117s atsparumas sukimo momentui<\/strong>, tod\u0117l jis yra b\u016btinas gamintojams, u\u017esiimantiems <strong data-start=\"1882\" data-end=\"1901\">\u0161virk\u0161t\u0173 bandymai<\/strong>.<\/p><p class=\"\" data-start=\"1904\" data-end=\"1941\">Pagrindiniai G4 priedo akcentai:<\/p><ul><li data-start=\"1944\" data-end=\"2066\"><strong data-start=\"1944\" data-end=\"1963\">Bandymo principas:<\/strong> Patikrinama, ar LLA apykakl\u0117 atlaiko sukimo moment\u0105 tvirtinant standartin\u0119 6% Luer k\u016bgin\u0119 jungt\u012f.<\/li><li data-start=\"2069\" data-end=\"2129\"><strong data-start=\"2069\" data-end=\"2099\">Rekomenduojamas m\u0117gini\u0173 \u0117mimo da\u017enis:<\/strong> 500 Hz, kai atliekami did\u017eiausi matavimai.<\/li><li data-start=\"2132\" data-end=\"2186\"><strong data-start=\"2132\" data-end=\"2160\">Standartinis sukimosi greitis:<\/strong> 20 apsisukim\u0173 per minut\u0119 arba pagal susitarim\u0105.<\/li><li data-start=\"2189\" data-end=\"2255\"><strong data-start=\"2189\" data-end=\"2212\">Matavimo i\u0161vestis:<\/strong> Did\u017eiausias sukimo momentas prad\u0117jus jud\u0117ti apykaklei.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1ed627 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"d1ed627\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"236\" height=\"361\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp\" class=\"attachment-full size-full wp-image-2107\" alt=\"LLA apykakl\u0117s atsparumas sukimo momentui - ISO 11040-4 \u0161virk\u0161to bandymas\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp 236w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing-196x300.webp 196w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47df98e elementor-widget elementor-widget-heading\" data-id=\"47df98e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">LLA apykakl\u0117s atsparumo sukimo momentui bandymo \u012franga<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4baaf8e elementor-widget elementor-widget-text-editor\" data-id=\"4baaf8e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2262\" data-end=\"2400\">Bandymui atlikti reikia tiksli\u0173 prietais\u0173. Standartin\u0119 s\u0105rank\u0105 sudaro:<\/p><ul><li data-start=\"2403\" data-end=\"2556\"><strong data-start=\"2403\" data-end=\"2441\">Sukimo momento matuoklis su sukimo \u012ftaisu<\/strong>: Tur\u0117t\u0173 b\u016bti galima nustatyti did\u017eiausi\u0105 sukimo moment\u0105, kurio skiriamoji geba yra <strong data-start=\"2507\" data-end=\"2519\">0,05 Ncm<\/strong>, idealus diapazonas yra <strong data-start=\"2539\" data-end=\"2555\">iki 35 Ncm<\/strong>.<\/li><li data-start=\"2559\" data-end=\"2630\"><strong data-start=\"2559\" data-end=\"2581\">LLA apykakl\u0117s spaustukas<\/strong>: Saugiai u\u017ever\u017eia apykakl\u0119 jos nepa\u017eeisdamas.<\/li><li data-start=\"2633\" data-end=\"2737\"><strong data-start=\"2633\" data-end=\"2661\">Pasukamas \u0161virk\u0161t\u0173 laikiklis<\/strong>: Leid\u017eia tiksliai ir nuosekliai pasukti \u0161virk\u0161t\u0105 arba u\u017erakt\u0105.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0058def elementor-widget elementor-widget-heading\" data-id=\"0058def\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testo atlikimo \u017eingsnis po \u017eingsnio vadovas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e82ef56 elementor-widget elementor-widget-text-editor\" data-id=\"e82ef56\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2938\" data-end=\"3119\">Kokyb\u0117s kontrol\u0117s specialistai gali vadovautis \u0161iais veiksmais, kad u\u017etikrint\u0173 tiksl\u0173 ir standartizuot\u0105 testavim\u0105. <strong data-start=\"3086\" data-end=\"3118\">LLA apykakl\u0117s atsparumas sukimo momentui<\/strong>:<\/p><ol><li data-start=\"3124\" data-end=\"3195\"><strong data-start=\"3124\" data-end=\"3134\">\u012ed\u0117kite<\/strong> sterilizuot\u0105 subomplektuot\u0105 \u0161virk\u0161t\u0105 \u012fstatykite \u012f \u0161virk\u0161to laikikl\u012f.<\/li><li data-start=\"3199\" data-end=\"3231\"><strong data-start=\"3199\" data-end=\"3209\">Pa\u0161alinti<\/strong> antgalio dangtel\u012f u\u017ed\u0117kite rankiniu b\u016bdu.<\/li><li data-start=\"3235\" data-end=\"3297\"><strong data-start=\"3235\" data-end=\"3244\">Kalnas<\/strong> tvirtai u\u017ed\u0117kite LLA apykakl\u0117s spaustuk\u0105 ant LLA apykakl\u0117s.<\/li><li data-start=\"3301\" data-end=\"3355\"><strong data-start=\"3301\" data-end=\"3309\">Nulis<\/strong> sukimo momento element\u0105, kad b\u016bt\u0173 pa\u0161alintas i\u0161ankstin\u0117s apkrovos sukimo momentas.<\/li><li data-start=\"3359\" data-end=\"3416\"><strong data-start=\"3359\" data-end=\"3366\">Nustatyti<\/strong> sukimosi greit\u012f iki 20 aps\/min (arba atitinkamai).<\/li><li data-start=\"3420\" data-end=\"3509\"><strong data-start=\"3420\" data-end=\"3432\">Inicijuokite<\/strong> bandym\u0105 pasukdami \u0161virk\u0161t\u0105 arba u\u017erakt\u0105 90\u00b0 kampu nurodyta kryptimi.<\/li><li data-start=\"3513\" data-end=\"3568\"><strong data-start=\"3513\" data-end=\"3523\">\u012era\u0161as<\/strong> did\u017eiausias sukimo momentas, kai prasideda apykakl\u0117s jud\u0117jimas.<\/li><\/ol><p class=\"\" data-start=\"3570\" data-end=\"3675\">\u0160i sukimo momento vert\u0117 atspindi <strong data-start=\"3601\" data-end=\"3623\">did\u017eiausias pasiprie\u0161inimas<\/strong> LLA apykakl\u0117s si\u016bloma operacin\u0117 \u012ftampa.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d445bbc e-con-full e-flex e-con e-child\" data-id=\"d445bbc\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-defbeb6 e-con-full e-flex e-con e-child\" data-id=\"defbeb6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c54c92 elementor-widget elementor-widget-heading\" data-id=\"1c54c92\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bandym\u0173 ataskait\u0173 teikimas ir kokyb\u0117s kontrol\u0117<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-669ef67 elementor-widget elementor-widget-text-editor\" data-id=\"669ef67\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3682\" data-end=\"3799\">Pagal ISO 11040-4 G4 pried\u0105 i\u0161samioje bandymo ataskaitoje turi b\u016bti:<\/p><ul><li data-start=\"3802\" data-end=\"3826\">Did\u017eiausios sukimo momento vert\u0117s (Ncm)<\/li><li data-start=\"3829\" data-end=\"3849\">Sukimosi greitis (aps.\/min.)<\/li><li data-start=\"3852\" data-end=\"3876\">I\u0161tirt\u0173 m\u0117gini\u0173 skai\u010dius<\/li><li data-start=\"3879\" data-end=\"3896\">\u012eskaitymo\/ne\u012fskaitymo rezultatai<\/li><li data-start=\"3899\" data-end=\"3931\">Pastabos d\u0117l nukrypim\u0173 ar anomalij\u0173<\/li><\/ul><p class=\"\" data-start=\"3933\" data-end=\"4059\">\u0160ie dokumentai u\u017etikrina atsekamum\u0105 ir atitikt\u012f, o tai labai svarbu atliekant reguliavimo audit\u0105 ir sertifikuojant gaminio i\u0161leidim\u0105.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb68c8a e-con-full e-flex e-con e-child\" data-id=\"cb68c8a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c067893 elementor-widget elementor-widget-heading\" data-id=\"c067893\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Automatizuoto sukimo momento testavimo privalumai<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36ac35a elementor-widget elementor-widget-text-editor\" data-id=\"36ac35a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4066\" data-end=\"4277\">\"Cell Instruments\" specializuojasi tiksli\u0173j\u0173 bandym\u0173 sistem\u0173, \u012fskaitant sukimo momento matuoklius, pritaikytus <strong data-start=\"4211\" data-end=\"4243\">LLA apykakl\u0117s atsparumas sukimo momentui<\/strong> vertinimai. Automatizavimas pagerina:<\/p><ul><li data-start=\"4280\" data-end=\"4309\"><strong data-start=\"4280\" data-end=\"4309\">Matavimo pakartojamumas<\/strong><\/li><li data-start=\"4312\" data-end=\"4329\"><strong data-start=\"4312\" data-end=\"4329\">Duomen\u0173 tikslumas<\/strong><\/li><li data-start=\"4332\" data-end=\"4358\"><strong data-start=\"4332\" data-end=\"4358\">Veiklos efektyvumas<\/strong><\/li><li data-start=\"4361\" data-end=\"4385\"><strong data-start=\"4361\" data-end=\"4385\">Atitikties u\u017etikrinimas<\/strong><\/li><\/ul><p class=\"\" data-start=\"4387\" data-end=\"4527\">Pritaikyti tvirtinimo \u012ftaisai ir programin\u0117s \u012frangos integracija leid\u017eia laboratorijoms supaprastinti \u0161virk\u0161t\u0173 tyrim\u0173 darbo eig\u0105, grie\u017etai laikantis ISO gairi\u0173.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11ccf92 elementor-widget elementor-widget-text-editor\" data-id=\"11ccf92\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4984\" data-end=\"5514\">Supratimas ir \u012fgyvendinimas <strong data-start=\"5036\" data-end=\"5068\">LLA apykakl\u0117s atsparumas sukimo momentui<\/strong> testas, suderintas su <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5092\" data-end=\"5107\">ISO 11040-4<\/strong><\/a> ir <strong data-start=\"5112\" data-end=\"5124\">G4 priedas<\/strong> labai svarbus \u0161virk\u0161t\u0173 kokyb\u0117s u\u017etikrinimui. \u0160is bandymas apsaugo nuo mechanini\u0173 gedim\u0173 klinikinio naudojimo metu ir padeda gamintojams laikytis auk\u0161\u010diausi\u0173 pacient\u0173 saugos standart\u0173. Svetain\u0117je <strong data-start=\"5308\" data-end=\"5328\">\"Cell Instruments<\/strong>, mes teikiame moderniausius sukamojo momento bandymo sprendimus, atitinkan\u010dius pasaulinius standartus ir pramon\u0117s poreikius, tod\u0117l \u0161virk\u0161t\u0173 gamintojams suteikiame patikim\u0173 duomen\u0173 ir pasitik\u0117jimo teis\u0117s aktais.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2105","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/lt\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/comments?post=2105"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2105\/revisions"}],"predecessor-version":[{"id":2111,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2105\/revisions\/2111"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/media?parent=2105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/categories?post=2105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/tags?post=2105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}