{"id":2073,"date":"2025-04-22T03:59:40","date_gmt":"2025-04-22T03:59:40","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2073"},"modified":"2025-04-22T06:49:25","modified_gmt":"2025-04-22T06:49:25","slug":"luer-cone-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/lt\/luer-cone-breakage-resistance-iso-11040-4\/","title":{"rendered":"Luer k\u016bgio atsparumas l\u016b\u017eimui - ISO 11040-4 priedas C2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2073\" class=\"elementor elementor-2073\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef785b6 e-flex e-con-boxed e-con e-parent\" data-id=\"ef785b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d4a251 elementor-widget elementor-widget-heading\" data-id=\"6d4a251\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Atsparumas Luer k\u016bgio l\u016b\u017eimui<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b910e1 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8b910e1\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec4bbc1 elementor-widget elementor-widget-heading\" data-id=\"ec4bbc1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 C2 priedas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bdc54b0 e-flex e-con-boxed e-con e-parent\" data-id=\"bdc54b0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a300c79 elementor-widget elementor-widget-text-editor\" data-id=\"a300c79\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"400\" data-end=\"1016\">\u0160virk\u0161t\u0173 gamyboje ir kokyb\u0117s kontrol\u0117je vienas i\u0161 svarbiausi\u0173 mechanini\u0173 vertinim\u0173 yra <strong data-start=\"520\" data-end=\"553\">atsparumas luer k\u016bgio l\u016b\u017eimui<\/strong> testas. \u0160virk\u0161to priekin\u0117s dalies konstrukcijos vientisumas, ypa\u010d luer k\u016bgio, turi tiesiogin\u0119 \u012ftak\u0105 paciento saugai ir prietaiso patikimumui. Siekiant u\u017etikrinti nuosekl\u0173 ir standartizuot\u0105 vertinim\u0105, <em data-start=\"749\" data-end=\"762\">ISO 11040-4<\/em> standartas, konkre\u010diai <em data-start=\"785\" data-end=\"795\">C2 priedas<\/em>-apib\u016bdina \u0161io bandymo atlikimo tvark\u0105 ir reikalavimus. \u0160iame straipsnyje apra\u0161omas bandym\u0173 procesas, svarbiausia \u012franga ir duomen\u0173 interpretavimas, reikalingi, kad b\u016bt\u0173 laikomasi reikalavim\u0173. <a href=\"https:\/\/www.pharmacopoeiatest.com\/lt\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> bandym\u0173 standartus.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3c5bd5 elementor-widget elementor-widget-heading\" data-id=\"b3c5bd5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer k\u016bgio atsparumo l\u016b\u017eiui svarba<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ddf4e elementor-widget elementor-widget-text-editor\" data-id=\"60ddf4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>\u0160virk\u0161to cilindro priekyje esantis luer k\u016bgis yra galimas silpnasis ta\u0161kas, kuris gali patirti mechanin\u0119 apkrov\u0105 tvarkant, montuojant ar \u0161virk\u0161\u010diant. <strong data-start=\"1248\" data-end=\"1281\">Atsparumas Luer k\u016bgio l\u016b\u017eimui<\/strong> bandymai padeda nustatyti, koki\u0105 j\u0117g\u0105 k\u016bgis gali atlaikyti prie\u0161 \u012ftr\u016bkim\u0105. Gamintojams <em data-start=\"1384\" data-end=\"1405\">i\u0161 anksto u\u017epildyti \u0161virk\u0161tai<\/em> ir <em data-start=\"1410\" data-end=\"1441\">stiklin\u0117s statin\u0117s injekciniams preparatams<\/em>, \u0161is bandymas n\u0117ra tik teis\u0117s akt\u0173 reikalavimas - tai pagrindin\u0117 kokyb\u0117s kontrol\u0117s priemon\u0117, padedanti i\u0161vengti nes\u0117kmi\u0173 medicinin\u0117se programose.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d476dd elementor-widget elementor-widget-heading\" data-id=\"3d476dd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 priedo C2 Luer k\u016bgio atsparumo l\u016b\u017eimui bandymo metodas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642e2e7 elementor-widget elementor-widget-text-editor\" data-id=\"642e2e7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1582\" data-end=\"2040\">Svetain\u0117 <strong data-start=\"1636\" data-end=\"1651\">ISO 11040-4<\/strong> standartas, pavadintas <em data-start=\"1669\" data-end=\"1784\">I\u0161 anksto u\u017epildyti \u0161virk\u0161tai. 4 dalis. Stiklin\u0117s statin\u0117s injekciniams vaistams ir sterilizuoti i\u0161 dalies surinkti \u0161virk\u0161tai, paruo\u0161ti u\u017epildymui<\/em>, \u012fskaitant <strong data-start=\"1795\" data-end=\"1807\">C2 priedas<\/strong>, kuriame i\u0161samiai apra\u0161oma <em data-start=\"1827\" data-end=\"1858\">priekin\u0117s dalies atsparumas l\u016b\u017eiams<\/em> testas. \u0160iame skyriuje apra\u0161omos s\u0105lygos, kuriomis turi b\u016bti atliekamas bandymas, \u012fskaitant reikalavimus prietaisams, m\u0117gini\u0173 tvarkym\u0105, bandymo proced\u016bras ir rezultat\u0173 dokumentavim\u0105.<\/p><h3 class=\"\" data-start=\"2042\" data-end=\"2077\">Pagrindin\u0117s testavimo s\u0105lygos:<\/h3><ul><li data-start=\"2080\" data-end=\"2105\">Bandymo greitis: <strong data-start=\"2092\" data-end=\"2105\">25 mm\/min<\/strong><\/li><li data-start=\"2080\" data-end=\"2105\">Taikymo vieta: <strong style=\"font-size: 16px;\" data-start=\"2127\" data-end=\"2135\">2 mm<\/strong><span style=\"font-size: 16px;\"> i\u0161 \u0161virk\u0161to antgalio<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Ma\u017eiausias m\u0117gini\u0173 \u0117mimo da\u017enis: <strong style=\"font-size: 16px;\" data-start=\"2182\" data-end=\"2192\">500 Hz<\/strong><span style=\"font-size: 16px;\"> maksimaliam matavimo tikslumui<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">J\u0117ga naudojama tol, kol <strong style=\"font-size: 16px;\" data-start=\"2245\" data-end=\"2263\">stiklo du\u017eimas<\/strong><span style=\"font-size: 16px;\"> atsiranda<\/span><\/li><\/ul><p class=\"\" data-start=\"2272\" data-end=\"2390\">Vadovaudamiesi \u0161iomis gair\u0117mis u\u017etikrinsite, kad j\u016bs\u0173 <strong data-start=\"2314\" data-end=\"2333\">\u0161virk\u0161t\u0173 bandymai<\/strong> procesai i\u0161lieka atsekami, atkuriami ir atitinka reikalavimus.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4dbc7e2 elementor-widget elementor-widget-heading\" data-id=\"4dbc7e2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161to testeris ISO 11040-4 priedo C2 bandymams atlikti<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7da5e4d elementor-widget elementor-widget-text-editor\" data-id=\"7da5e4d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2454\" data-end=\"2671\">Nor\u0117dami tiksliai atlikti <strong data-start=\"2476\" data-end=\"2509\">atsparumas luer k\u016bgio l\u016b\u017eimui<\/strong> testus, jums reik\u0117s patikimo ir tikslaus <strong data-start=\"2552\" data-end=\"2605\">universali tempimo ir gniu\u017edymo bandymo ma\u0161ina<\/strong>. Aparatas turi atitikti \u0161iuos ISO 11040-4 priedo C2 reikalavimus:<\/p><ul><li data-start=\"2675\" data-end=\"2729\">A <strong data-start=\"2677\" data-end=\"2690\">apkrovos elementas<\/strong> tinka l\u016b\u017eio j\u0117goms matuoti<\/li><li data-start=\"2675\" data-end=\"2729\">Tikslus, programuojamas <strong style=\"font-size: 16px;\" data-start=\"2758\" data-end=\"2780\">bandymo grei\u010dio valdymas<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Pasirinktinis <strong style=\"font-size: 16px;\" data-start=\"2792\" data-end=\"2834\">ner\u016bdijan\u010dio plieno laikiklis ir krovimo strypas<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Adapteri\u0173 rinkiniai, atitinkantys j\u016bs\u0173 \u0161virk\u0161to konstrukcijos geometrij\u0105<\/li><\/ul><h3 class=\"\" data-start=\"2889\" data-end=\"2967\">Rekomenduojamas \u0161virk\u0161t\u0173 testeris<\/h3><p class=\"\" data-start=\"2969\" data-end=\"3383\">\"Cell Instruments <em>\u0160virk\u0161t\u0173 testeris<\/em>\u00a0sukurtas taip, kad atitikt\u0173 grie\u017etus ISO \u0161virk\u0161t\u0173 bandym\u0173 reikalavimus. MPT-01 turi programuojam\u0105 PLC valdym\u0105, tiksli\u0105 mechanik\u0105 ir pritaikomus laikiklius, tod\u0117l juo galima gauti didel\u0117s skiriamosios gebos j\u0117gos ir poslinkio duomenis, tod\u0117l jis idealiai tinka <strong data-start=\"3241\" data-end=\"3274\">atsparumas luer k\u016bgio l\u016b\u017eimui<\/strong> vertinimai. Integruotas mikroprinteris ir pasirenkamas RS232 duomen\u0173 eksportas taip pat padeda parengti i\u0161sami\u0105 dokumentacij\u0105.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4ff2b elementor-widget elementor-widget-heading\" data-id=\"6b4ff2b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer k\u016bgio atsparumo l\u016b\u017eimui bandymo proced\u016bra<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c990a3c e-con-full e-flex e-con e-child\" data-id=\"c990a3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-dbcf8eb e-con-full e-flex e-con e-child\" data-id=\"dbcf8eb\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53324d6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"53324d6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 \u0161virk\u0161t\u0173 nuot\u0117kio bandymas\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9962325 e-con-full e-flex e-con e-child\" data-id=\"9962325\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea7609b elementor-widget elementor-widget-text-editor\" data-id=\"ea7609b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3460\" data-end=\"3483\"><strong>1. Pasirengimas testui<\/strong><\/p><ul><li data-start=\"3486\" data-end=\"3553\">Patikrinkite visus adapterius ir med\u017eiagas, ar <strong data-start=\"3525\" data-end=\"3552\">pa\u017eeidimai ar suderinamumas<\/strong>.<\/li><li data-start=\"3486\" data-end=\"3553\">Sumontuokite reikiam\u0105 adapter\u012f ir laikiklius ant <strong style=\"font-size: 16px;\">\u0160virk\u0161t\u0173 testeris<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3486\" data-end=\"3553\">U\u017etikrinkite tinkam\u0105 suderinim\u0105 ir <strong style=\"font-size: 16px;\" data-start=\"3652\" data-end=\"3677\">\u012frengti apsauginius skydelius<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul><p data-start=\"3680\" data-end=\"3704\"><strong>2. Testavimo vykdymas<\/strong><\/p><ul><li data-start=\"3707\" data-end=\"3749\">\u012eki\u0161kite \u0161virk\u0161to cilindr\u0105 \u012f laikikl\u012f.<\/li><li data-start=\"3707\" data-end=\"3749\">\u012ekrovimo kai\u0161\u010dio pad\u0117tis <strong style=\"font-size: 16px;\" data-start=\"3777\" data-end=\"3806\">2 mm nuo \u0161virk\u0161to antgalio<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Nustatykite greit\u012f \u012f <strong style=\"font-size: 16px;\" data-start=\"3827\" data-end=\"3840\">25 mm\/min<\/strong><span style=\"font-size: 16px;\"> ir prad\u0117kite test\u0105.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Suspauskite tol, kol luer k\u016bgis <strong style=\"font-size: 16px;\" data-start=\"3901\" data-end=\"3914\">l\u016b\u017eiai<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">\u012era\u0161ykite <strong style=\"font-size: 16px;\" data-start=\"3929\" data-end=\"3958\">did\u017eiausia j\u0117ga l\u016b\u017eio metu<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4898eec elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"4898eec\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"272\" height=\"270\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png\" class=\"attachment-large size-large wp-image-2078\" alt=\"\u0160virk\u0161to k\u016bgio atsparumas l\u016b\u017eimui - ISO 11040-4 priedo C2 \u0161virk\u0161to bandymas\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png 272w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing-150x150.png 150w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322584f elementor-widget elementor-widget-text-editor\" data-id=\"322584f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3961\" data-end=\"3999\"><b>3. Po testo atliekamas valymas ir analiz\u0117<\/b><\/p><ul><li data-start=\"4002\" data-end=\"4038\">Atsargiai i\u0161imkite sugedus\u012f \u0161virk\u0161t\u0105.<\/li><li data-start=\"4002\" data-end=\"4038\">I\u0161valykite adapter\u012f, kad pa\u0161alintum\u0117te stiklo liku\u010dius.<\/li><li data-start=\"4002\" data-end=\"4038\">Analizuokite rezultatus ir patvirtinkite <strong style=\"font-size: 16px;\" data-start=\"4117\" data-end=\"4138\">l\u016b\u017eio vieta<\/strong><span style=\"font-size: 16px;\"> priekyje.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04ee823 elementor-widget elementor-widget-heading\" data-id=\"04ee823\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Rezultat\u0173 ataskait\u0173 teikimo reikalavimai pagal ISO 11040-4<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a8c95c elementor-widget elementor-widget-text-editor\" data-id=\"9a8c95c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4216\" data-end=\"4286\">Kiekvienas bandymas turi b\u016bti kruop\u0161\u010diai dokumentuojamas, \u012fskaitant \u0161iuos duomenis:<\/p><ul><li data-start=\"4289\" data-end=\"4313\"><strong data-start=\"4289\" data-end=\"4303\">Bandymo greitis<\/strong> mm\/min<\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4316\" data-end=\"4349\">Atstumas nuo \u0161virk\u0161to antgalio<\/strong><span style=\"font-size: 16px;\"> prie kurios veik\u0117 j\u0117ga.<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4383\" data-end=\"4409\">Did\u017eiausia lau\u017eimo j\u0117ga<\/strong><span style=\"font-size: 16px;\"> niutonais (N)<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4427\" data-end=\"4446\">M\u0117ginio kiekis<\/strong><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4449\" data-end=\"4480\">Bet kokios anomalijos ar nukrypimai<\/strong><span style=\"font-size: 16px;\"> i\u0161 proced\u016bros<\/span><\/li><\/ul><p class=\"\" data-start=\"4501\" data-end=\"4652\">Toks detalumas u\u017etikrina nuoseklum\u0105 ir atsekamum\u0105, ypa\u010d tvirtinant nauj\u0173 \u0161virk\u0161t\u0173 dizain\u0105 arba atliekant \u012fprastus kokyb\u0117s patikrinimus.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c3b5bb elementor-widget elementor-widget-heading\" data-id=\"5c3b5bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kod\u0117l verta rinktis \"Cell Instruments\" \u0161virk\u0161t\u0173 bandymams?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7471474 elementor-widget elementor-widget-text-editor\" data-id=\"7471474\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4659\" data-end=\"5243\">De\u0161imtme\u010dius sukaupta patirtis <strong data-start=\"4744\" data-end=\"4779\">medicinos prietais\u0173 med\u017eiag\u0173 bandymai<\/strong>, <strong data-start=\"4781\" data-end=\"4801\">\"Cell Instruments<\/strong> si\u016blo naujausius bandym\u0173 sprendimus, pritaikytus ISO ir ASTM standartams. M\u016bs\u0173 <strong>\u0160virk\u0161t\u0173 testeris<\/strong> yra specialiai sukurta taip, kad palaikyt\u0173 \u012fvairias <strong data-start=\"4971\" data-end=\"4990\">\u0161virk\u0161t\u0173 bandymai<\/strong> metodai, \u012fskaitant <strong data-start=\"5010\" data-end=\"5043\">atsparumas luer k\u016bgio l\u016b\u017eimui<\/strong>. Nesvarbu, ar vykdote gamyb\u0105, mokslinius tyrimus, ar tre\u010di\u0173j\u0173 \u0161ali\u0173 patikr\u0105, \"Cell Instruments\" gali pasi\u016blyti individualius sprendimus, automatizavimo integracij\u0105 ir visapusi\u0161k\u0105 pagalb\u0105, kad patenkint\u0173 j\u016bs\u0173 bandym\u0173 poreikius.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02c15b6 elementor-widget elementor-widget-text-editor\" data-id=\"02c15b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5250\" data-end=\"5668\">Atlikimas <strong data-start=\"5278\" data-end=\"5311\">atsparumas luer k\u016bgio l\u016b\u017eimui<\/strong> bandymai pagal <strong data-start=\"5337\" data-end=\"5361\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> C2 priedas<\/strong> labai svarbu u\u017etikrinti mechanin\u012f \u0161virk\u0161t\u0173 komponent\u0173 vientisum\u0105. Naudojant tiksli\u0105 \u012frang\u0105, pvz. <strong>\u0160virk\u0161t\u0173 testeris<\/strong>, ir \u017eingsnis po \u017eingsnio vadovaudamiesi ISO nustatyta proced\u016bra, galite u\u017etikrintai patikrinti produkto kokyb\u0119, u\u017etikrinti atitikt\u012f teis\u0117s akt\u0173 reikalavimams ir apsaugoti pacient\u0173 saug\u0105.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3344b6 elementor-widget elementor-widget-text-editor\" data-id=\"a3344b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\"><strong data-start=\"5675\" data-end=\"5746\">Ie\u0161kote ISO 11040-4 standart\u0105 atitinkan\u010di\u0173 \u0161virk\u0161t\u0173 testavimo sprendim\u0173?<\/strong><\/p><p class=\"\" data-start=\"5420\" data-end=\"5503\">Susisiekite su <strong data-start=\"5757\" data-end=\"5787\">Cell Instruments Co., Ltd.<\/strong> \u0161iandien, kad gautum\u0117te ekspert\u0173 rekomendacijas ir specialiai jums pritaikytas \u0161virk\u0161t\u0173 kokyb\u0117s u\u017etikrinimo sistemas.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2073","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/lt\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/comments?post=2073"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2073\/revisions"}],"predecessor-version":[{"id":2084,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/2073\/revisions\/2084"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/media?parent=2073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/categories?post=2073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/tags?post=2073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}