{"id":1893,"date":"2025-01-24T05:40:31","date_gmt":"2025-01-24T05:40:31","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=1893"},"modified":"2025-04-02T06:30:55","modified_gmt":"2025-04-02T06:30:55","slug":"syringe-glide-force-testing-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/lt\/syringe-glide-force-testing-iso-11040-4\/","title":{"rendered":"\u0160virk\u0161to slydimo j\u0117gos bandymas | ISO 11040-4 E priedas"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"1893\" class=\"elementor elementor-1893\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c8f6b32 e-flex e-con-boxed e-con e-parent\" data-id=\"c8f6b32\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3871c01 elementor-widget elementor-widget-heading\" data-id=\"3871c01\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161to slydimo j\u0117gos bandymas<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28eeae4 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"28eeae4\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c6f7aa elementor-widget elementor-widget-heading\" data-id=\"9c6f7aa\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 E priedas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-60074b4 e-flex e-con-boxed e-con e-parent\" data-id=\"60074b4\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-9e604be e-con-full e-flex e-con e-child\" data-id=\"9e604be\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-815caf1 elementor-widget elementor-widget-text-editor\" data-id=\"815caf1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Medicinos ir farmacijos pramon\u0117je labai svarbu u\u017etikrinti \u0161virk\u0161t\u0173 veikim\u0105 ir kokyb\u0119. Vienas i\u0161 svarbiausi\u0173 \u0161virk\u0161t\u0173 funkcionalumo vertinimo metod\u0173 yra <strong>ISO 11040-4 \u0161virk\u0161to slydimo j\u0117gos bandymas<\/strong>. \u0160is standartas padeda gamintojams u\u017etikrinti, kad \u0161virk\u0161tai, tiek sutepti, tiek nesutepti, b\u016bt\u0173 nuosekliai ir patikimai naudojami vaistams tiekti.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf043c8 elementor-widget elementor-widget-heading\" data-id=\"bf043c8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kas yra ISO 11040-4 \u0161virk\u0161to slydimo j\u0117gos bandymas?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7514f4b elementor-widget elementor-widget-text-editor\" data-id=\"7514f4b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>ISO 11040-4 apra\u0161oma matavimo proced\u016bra <strong>slydimo j\u0117ga<\/strong> \u0161virk\u0161to j\u0117ga, kurios reikia st\u016bmokliui judinti cilindre. \u0160is bandymas yra labai svarbus \u0161virk\u0161t\u0173 kokybei ir pastovumui \u012fvertinti, ypa\u010d kai jie naudojami medicinoje.<\/p><p>\u0160io testavimo tikslas yra dvejopas:<\/p><ol><li><strong>Tepimo \u012fvertinimas<\/strong>: Jis padeda nustatyti \u0161virk\u0161to cilindro viduje esan\u010dio tepimo efektyvum\u0105, kuris paprastai pasiekiamas naudojant silikonin\u0119 alyv\u0105 ar kitas med\u017eiagas.<\/li><li><strong>\u0160virk\u0161tai be tepalo<\/strong>: Atliekant bandym\u0105 taip pat vertinami nesutepti \u0161virk\u0161tai, \u012fskaitant u\u017epildytus vandeniu injekcijoms, imituojant realias naudojimo s\u0105lygas.<\/li><\/ol><p>\u0160ia proced\u016bra u\u017etikrinama, kad \u0161virk\u0161tai atitikt\u0173 tam tikrus slydimo j\u0117gos standartus, suma\u017e\u0117t\u0173 trintis \u0161virk\u0161\u010diant ir b\u016bt\u0173 u\u017etikrintas paciento saugumas bei patogumas.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91331e3 elementor-widget elementor-widget-heading\" data-id=\"91331e3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161t\u0173 slydimo j\u0117gos svarba<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61602c4 elementor-widget elementor-widget-text-editor\" data-id=\"61602c4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Slydimo j\u0117gos bandymas - tai ne tik sklandaus st\u016bmoklio jud\u0117jimo u\u017etikrinimas. Slydimo j\u0117ga parodo <strong>veiklos kokyb\u0117<\/strong> \u0161virk\u0161to:<\/p><ul><li><strong>Didel\u0117 slydimo j\u0117ga<\/strong>: Per didel\u0117 trintis gali sukelti diskomfort\u0105 \u0161virk\u0161\u010diant ir net apsunkinti sveikatos prie\u017ei\u016bros specialist\u0173 darb\u0105.<\/li><li><strong>Ma\u017ea slydimo j\u0117ga<\/strong>: D\u0117l nepakankamos trinties gali atsirasti nuot\u0117kis, tod\u0117l \u0161virk\u0161tas tampa nepatikimas ir gali b\u016bti nesaugus naudoti medicinoje.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a343f22 elementor-widget elementor-widget-heading\" data-id=\"a343f22\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 \u0161virk\u0161to slydimo j\u0117gos bandymams reikalingos med\u017eiagos<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78bacbc elementor-widget elementor-widget-text-editor\" data-id=\"78bacbc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Norint atlikti veiksmingus bandymus, reikia tam tikr\u0173 med\u017eiag\u0173 ir \u012frangos, \u012fskaitant:<\/p><ul><li><strong>Sterilizuoti \u0161virk\u0161tai<\/strong>: Tiriami \u0161virk\u0161tai turi b\u016bti paruo\u0161ti u\u017epildymui, tinkamai sterilizuoti, kad b\u016bt\u0173 i\u0161vengta u\u017eter\u0161imo.<\/li><li><strong>St\u016bmoklio kam\u0161\u010diai<\/strong>: Jie turi b\u016bti suderinami su \u0161virk\u0161to cilindru ir jo paskirtimi.<\/li><li><strong>St\u016bmoklio strypai<\/strong>: Jie yra b\u016btini, kad atliekant bandymus b\u016bt\u0173 galima naudoti reikiam\u0105 j\u0117g\u0105.<\/li><\/ul><p>D\u0117l \u0161i\u0173 med\u017eiag\u0173 turi susitarti gamintojas ir klientas, ypating\u0105 d\u0117mes\u012f skiriant st\u016bmoklio kam\u0161\u010dio tipui ir jo tepimui.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba26707 elementor-widget elementor-widget-heading\" data-id=\"ba26707\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 bandymams naudojami prietaisai<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e84859 elementor-widget elementor-widget-image\" data-id=\"3e84859\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/lt\/medical-syringe-tester\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/elementor\/thumbs\/syringe-glide-force-testing-iso-11040-4-1-scaled-r0grycyljh00j2lr5tp8u0op55p1txljfuzjxlcwi0.webp\" title=\"\u0160virk\u0161to slydimo j\u0117gos bandymas iso 11040 4\" alt=\"\u0160virk\u0161to slydimo j\u0117gos bandymas iso 11040 4\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e366efc elementor-widget elementor-widget-text-editor\" data-id=\"e366efc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>ISO 11040-4 bandymams atlikti reikia specialios \u012frangos:<\/p><ul><li><strong>Universali tempimo ir gniu\u017edymo bandymo ma\u0161ina<\/strong>: \u0160is aparatas naudojamas tam tikru grei\u010diu, paprastai 100 mm\/min, veikian\u010diai j\u0117gai taikyti, kad b\u016bt\u0173 galima tiksliai i\u0161matuoti slydimo j\u0117g\u0105. Priklausomai nuo \u0161virk\u0161to specifikacij\u0173, j\u0117gos diapazonas tur\u0117t\u0173 b\u016bti ne ma\u017eesnis kaip 50 N.<\/li><li><strong>\u0160virk\u0161t\u0173 atramos ir adapteri\u0173 plok\u0161tel\u0117s<\/strong>: Jie naudojami \u0161virk\u0161tui prilaikyti bandymo metu, kad b\u016bt\u0173 u\u017etikrinta tinkama j\u0117ga.<\/li><li><strong>Ventiliacijos vamzdelio arba vakuuminio u\u017ekim\u0161imo \u012frankis<\/strong>: \u0160is \u012frankis naudojamas st\u016bmoklio kam\u0161\u010diui \u012fstatyti \u012f \u0161virk\u0161to cilindr\u0105, u\u017etikrinant sterilum\u0105 ir tinkam\u0105 pad\u0117t\u012f.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e772501 elementor-widget elementor-widget-heading\" data-id=\"e772501\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bandymo atlikimo proced\u016bra\n<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1923553 elementor-widget elementor-widget-text-editor\" data-id=\"1923553\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>ISO 11040-4 slydimo j\u0117gos bandymas atliekamas pagal sisteming\u0105 proced\u016br\u0105:<\/p><ol><li><strong>\u012ed\u0117kite st\u016bmoklio kam\u0161t\u012f<\/strong>: \u012estatykite st\u016bmoklio kam\u0161t\u012f \u012f \u0161virk\u0161to cilindr\u0105 naudodami ventiliacijos vamzdel\u012f arba vakuumin\u012f kam\u0161t\u012f.<\/li><li><strong>St\u016bmoklio strypo nustatymas<\/strong>: Pritvirtinkite st\u016bmoklio stryp\u0105 prie kam\u0161\u010dio, u\u017etikrindami, kad jis sutapt\u0173 su bandymo \u012ftaisu.<\/li><li><strong>\u012ed\u0117kite \u0161virk\u0161t\u0105 \u012f bandymo prietais\u0105<\/strong>: \u012estatykite \u0161virk\u0161t\u0105 \u012f tempimo bandymo aparato adapterio plok\u0161tel\u0119.<\/li><li><strong>Taikyti j\u0117g\u0105<\/strong>: Prad\u0117kite gniu\u017edymo bandym\u0105, naudodami j\u0117g\u0105 sutartu grei\u010diu, paprastai 100 mm\/min.<\/li><li><strong>Did\u017eiausios j\u0117gos matavimas<\/strong>: U\u017era\u0161ykite did\u017eiausi\u0105 j\u0117g\u0105, patirt\u0105 slydimo j\u0117gos bandymo srityje, t. y. atkarpoje tarp pradin\u0117s j\u0117gos ir staigaus padid\u0117jimo st\u016bmoklio eigos pabaigoje.<\/li><li><strong>Pakartokite, jei norite imti kelis m\u0117ginius<\/strong>: Atlikite bandym\u0105 su keliais \u0161virk\u0161tais, kad u\u017etikrintum\u0117te nuoseklum\u0105.<\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b869036 elementor-widget elementor-widget-heading\" data-id=\"b869036\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161to st\u016bmoklio j\u0117gos apskai\u010diavimas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c126a7 elementor-widget elementor-widget-text-editor\" data-id=\"1c126a7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Bandymo rezultatai yra dokumentuojami, \u012fskaitant:<\/p><ul><li><strong>Did\u017eiausia slydimo j\u0117ga<\/strong>: Did\u017eiausia j\u0117ga, pasteb\u0117ta slydimo j\u0117gos bandymo srityje.<\/li><li><strong>Vidutin\u0117 slydimo j\u0117ga<\/strong>: Apskai\u010diuota vidutin\u0117 j\u0117ga, kuri leid\u017eia susidaryti bendr\u0105 \u0161virk\u0161to veikimo vaizd\u0105.<\/li><li><strong>Bandym\u0173 dokumentacija<\/strong>: Siekiant u\u017etikrinti atsekamum\u0105 ir atitikt\u012f, reikia pa\u017eym\u0117ti bet kokius nukrypimus ar pastabas.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c72def5 elementor-widget elementor-widget-heading\" data-id=\"c72def5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pagrindiniai aspektai, susij\u0119 su tiksliu slydimo j\u0117gos bandymu<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9d3425 elementor-widget elementor-widget-text-editor\" data-id=\"f9d3425\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li><strong>Bandymo greitis<\/strong>: Paprastai naudojamas 100 mm\/min greitis, ta\u010diau jis gali skirtis priklausomai nuo gamintojo reikalavim\u0173.<\/li><li><strong>\u0116mini\u0173 \u0117mimo da\u017enis<\/strong>: Norint tiksliau i\u0161matuoti pik\u0105, rekomenduojama naudoti didesn\u012f diskretizavimo da\u017en\u012f (pvz., 500 Hz).<\/li><li><strong>Bandomoji aplinka<\/strong>: Bandym\u0173 aplinka tur\u0117t\u0173 b\u016bti kontroliuojama, kad i\u0161oriniai veiksniai, pavyzd\u017eiui, temperat\u016bra ar dr\u0117gm\u0117, netur\u0117t\u0173 \u012ftakos rezultatams.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Glide Force Testing ISO 11040-4 Annex E In the medical and pharmaceutical industries, ensuring the performance and quality of syringes is paramount. One critical method for assessing syringe functionality is through the ISO 11040-4 syringe glide force testing. This standard helps manufacturers ensure that syringes, whether lubricated or non-lubricated, perform consistently and reliably when [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-1893","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/lt\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Syringe Glide Force Testing ISO 11040-4 Annex E In the medical and pharmaceutical industries, ensuring the performance and quality of syringes is paramount. One critical method for assessing syringe functionality is through the ISO 11040-4 syringe glide force testing. This standard helps manufacturers ensure that syringes, whether lubricated or non-lubricated, perform consistently and reliably when&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/1893","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/comments?post=1893"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/1893\/revisions"}],"predecessor-version":[{"id":2012,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/posts\/1893\/revisions\/2012"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/media?parent=1893"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/categories?post=1893"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/lt\/wp-json\/wp\/v2\/tags?post=1893"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}