{"id":2197,"date":"2025-06-24T02:14:04","date_gmt":"2025-06-24T02:14:04","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2197"},"modified":"2026-05-07T07:50:30","modified_gmt":"2026-05-07T07:50:30","slug":"iso-7864","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/it\/iso-7864\/","title":{"rendered":"ISO 7864 Test di funzionalit\u00e0 delle siringhe ipodermiche"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2197\" class=\"elementor elementor-2197\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-66b560c e-flex e-con-boxed e-con e-parent\" data-id=\"66b560c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-86c40f3 elementor-widget elementor-widget-heading\" data-id=\"86c40f3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 7864 <br><small><small>Test di funzionalit\u00e0 delle siringhe ipodermiche<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b5014aa e-con-full e-flex e-con e-child\" data-id=\"b5014aa\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dea855d elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"dea855d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"398\" data-end=\"1099\">Quando si tratta di aghi ipodermici sterili, la sicurezza del paziente e le prestazioni del prodotto non sono negoziabili. \u00c8 qui che <strong data-start=\"534\" data-end=\"546\">ISO 7864<\/strong> svolge un ruolo fondamentale. Questo standard internazionale delinea requisiti e metodi di prova completi per valutare gli aghi ipodermici per <strong data-start=\"683\" data-end=\"706\">siringhe monouso<\/strong>, tra cui <strong data-start=\"718\" data-end=\"751\">test di funzionalit\u00e0 della siringa<\/strong>, <strong data-start=\"753\" data-end=\"787\">metodo di prova di penetrazione dell'ago<\/strong>, e <strong data-start=\"793\" data-end=\"820\">forza del legame con l'ago<\/strong>. Produttori, tecnici del controllo qualit\u00e0 ed enti normativi si affidano alla norma ISO 7864 per garantire la qualit\u00e0 e la sicurezza dei prodotti.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f53d82 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"7f53d82\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/it\/syringe-needle-penetration-test\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1.webp\" class=\"attachment-full size-full wp-image-2200\" alt=\"ISO 7864 Test di funzionalit\u00e0 delle siringhe ipodermiche\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1-300x200.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11bf196 elementor-widget elementor-widget-heading\" data-id=\"11bf196\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Cos'\u00e8 l'ISO 7864 e perch\u00e9 \u00e8 importante<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edf0ed0 elementor-widget elementor-widget-text-editor\" data-id=\"edf0ed0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1422\"><strong data-start=\"1148\" data-end=\"1160\">ISO 7864<\/strong> \u00e8 il <strong data-start=\"1168\" data-end=\"1225\">Standard internazionale per aghi ipodermici sterili<\/strong> destinati al monouso con siringhe o apparecchiature per infusione. Definisce i requisiti fisici dell'ago, le dimensioni, le caratteristiche prestazionali, l'imballaggio e le modalit\u00e0 di confezionamento. <strong data-start=\"1390\" data-end=\"1406\">metodi di prova<\/strong> per la valutazione:<\/p><ul><li data-start=\"1426\" data-end=\"1445\"><strong data-start=\"1426\" data-end=\"1443\">Penetrabilit\u00e0<\/strong><\/li><li data-start=\"1448\" data-end=\"1470\"><strong data-start=\"1448\" data-end=\"1468\">Forza di legame<\/strong><\/li><li data-start=\"1473\" data-end=\"1500\"><strong data-start=\"1473\" data-end=\"1498\">Integrit\u00e0 del tubo dell'ago<\/strong><\/li><li data-start=\"1503\" data-end=\"1529\"><strong data-start=\"1503\" data-end=\"1527\">Resistenza alla corrosione<\/strong><\/li><li data-start=\"1532\" data-end=\"1557\"><strong data-start=\"1532\" data-end=\"1557\">Compatibilit\u00e0 con le siringhe<\/strong><\/li><\/ul><p data-start=\"1559\" data-end=\"1707\">La conformit\u00e0 alla norma ISO 7864 garantisce che gli aghi funzionino in modo affidabile in condizioni cliniche, riducendo i rischi per i pazienti e gli operatori sanitari.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f659161 elementor-widget elementor-widget-heading\" data-id=\"f659161\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test di funzionalit\u00e0 delle siringhe ISO<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1eb6db elementor-widget elementor-widget-text-editor\" data-id=\"c1eb6db\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1714\" data-end=\"1946\"><strong data-start=\"1782\" data-end=\"1815\">Test di funzionalit\u00e0 della siringa<\/strong> garantisce che l'ago sia compatibile con la siringa designata e che funzioni efficacemente durante l'iniezione. I parametri testati includono:<\/p><ul><li data-start=\"1950\" data-end=\"1990\"><strong data-start=\"1950\" data-end=\"1988\">Compatibilit\u00e0 con i connettori Luer<\/strong><\/li><li data-start=\"1993\" data-end=\"2012\"><strong data-start=\"1993\" data-end=\"2010\">Forza dello stantuffo<\/strong><\/li><li data-start=\"2015\" data-end=\"2048\"><strong data-start=\"2015\" data-end=\"2046\">Consistenza della forza di iniezione<\/strong><\/li><li data-start=\"2051\" data-end=\"2078\"><strong data-start=\"2051\" data-end=\"2078\">Riduzione dello spazio morto<\/strong><\/li><\/ul><p data-start=\"2080\" data-end=\"2309\">Queste valutazioni sono fondamentali per un <strong data-start=\"2118\" data-end=\"2133\">Siringa ISO<\/strong> per superare la certificazione. Cell Instruments fornisce soluzioni che valutano la funzionalit\u00e0 misurando la forza di inserimento, la resistenza dello stantuffo e la distribuzione della forza durante l'iniezione.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64b918a elementor-widget elementor-widget-heading\" data-id=\"64b918a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test di penetrabilit\u00e0 dell'ago<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7baacfb elementor-widget elementor-widget-text-editor\" data-id=\"7baacfb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2316\" data-end=\"2506\">Uno dei test pi\u00f9 importanti previsti dalla norma ISO 7864 \u00e8 la <strong data-start=\"2429\" data-end=\"2463\">metodo di prova di penetrazione dell'ago<\/strong>, noto anche come il <strong data-start=\"2483\" data-end=\"2505\">test di penetrabilit\u00e0<\/strong>.<\/p><p data-start=\"2508\" data-end=\"2747\"><strong data-start=\"2508\" data-end=\"2526\">Principio del test<\/strong><br data-start=\"2526\" data-end=\"2529\" \/>L'ago viene inserito in un campione standardizzato <strong data-start=\"2570\" data-end=\"2583\">substrato<\/strong> a velocit\u00e0 costante (in genere 100 mm\/min). Il <strong data-start=\"2632\" data-end=\"2658\">forza di penetrazione di picco<\/strong> e <strong data-start=\"2663\" data-end=\"2677\">forza di trascinamento<\/strong> vengono registrati per valutare la facilit\u00e0 di penetrazione e la coerenza del movimento.<\/p><p data-start=\"2749\" data-end=\"2768\"><strong data-start=\"2749\" data-end=\"2766\">Attrezzatura chiave<\/strong><\/p><ul><li data-start=\"2771\" data-end=\"2826\">Sistema di misurazione della forza con precisione <strong data-start=\"2811\" data-end=\"2824\">cella di carico<\/strong><\/li><li data-start=\"2829\" data-end=\"2865\">Porta aghi con allineamento assiale<\/li><li data-start=\"2868\" data-end=\"2918\">Substrato convalidato (ad esempio, gomma di lattice o LDPE)<\/li><li data-start=\"2921\" data-end=\"2979\">Misuratore di profondit\u00e0 di penetrazione (tipicamente 80% della lunghezza dell'ago)<\/li><\/ul><p data-start=\"2981\" data-end=\"3175\"><strong data-start=\"2981\" data-end=\"3001\">Strumenti a cella<\/strong> offerte <strong data-start=\"3009\" data-end=\"3049\">penetratore automatico ad aghi<\/strong>\u00a0con velocit\u00e0 programmabili e analisi digitale della forza per garantire precisione e ripetibilit\u00e0 in conformit\u00e0 alla norma ISO 7864 Allegato D.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46d372b elementor-widget elementor-widget-heading\" data-id=\"46d372b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Forza di trascinamento e forza di penetrazione di picco<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b565e71 elementor-widget elementor-widget-text-editor\" data-id=\"b565e71\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3182\" data-end=\"3269\">Si ricavano due risultati principali:<\/p><ul><li data-start=\"3273\" data-end=\"3345\"><strong data-start=\"3273\" data-end=\"3300\">Forza di penetrazione di picco:<\/strong> Forza massima richiesta per perforare il substrato<\/li><li data-start=\"3348\" data-end=\"3436\"><strong data-start=\"3348\" data-end=\"3363\">Forza di trascinamento:<\/strong> Forza media necessaria per mantenere la penetrazione su 80% di lunghezza dell'ago<\/li><\/ul><p data-start=\"3438\" data-end=\"3600\">Queste metriche riflettono l'affilatura dell'ago, l'attrito e la coerenza della produzione. Per la presentazione delle normative e la convalida dei progetti, la precisione delle misure \u00e8 fondamentale.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c892b5 elementor-widget elementor-widget-heading\" data-id=\"5c892b5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test di resistenza del legame con l'ago<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30d6b5b elementor-widget elementor-widget-text-editor\" data-id=\"30d6b5b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3607\" data-end=\"3825\">La forza di legame si riferisce alla <strong data-start=\"3697\" data-end=\"3745\">adesione tra il tubo dell'ago e il mozzo<\/strong>-Un legame debole potrebbe causare il distacco durante l'iniezione, con gravi rischi per la salute.<\/p><p data-start=\"3827\" data-end=\"3870\"><strong data-start=\"3827\" data-end=\"3868\">Procedura di prova (ISO 7864 Allegato E):<\/strong><\/p><ul><li data-start=\"3873\" data-end=\"3938\">L'ago viene impugnato verticalmente su un <strong data-start=\"3907\" data-end=\"3936\">macchina di prova universale<\/strong><\/li><li data-start=\"3941\" data-end=\"3986\">A <strong data-start=\"3943\" data-end=\"3960\">forza di trazione<\/strong> viene applicato a 50 mm\/min<\/li><li data-start=\"3989\" data-end=\"4062\">Il <strong data-start=\"3993\" data-end=\"4010\">forza massima<\/strong> in cui si verifica il distacco o l'avaria viene registrato<\/li><\/ul><p data-start=\"4064\" data-end=\"4223\"><strong data-start=\"4064\" data-end=\"4084\">Strumenti a cella<\/strong> fornisce <strong data-start=\"4094\" data-end=\"4123\">tester di trazione universale<\/strong>\u00a0con attrezzature personalizzate per <strong data-start=\"4153\" data-end=\"4177\">test di incollaggio dell'ago<\/strong>garantendo la conformit\u00e0 con le procedure dell'Allegato E.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94ab6f1 elementor-widget elementor-widget-heading\" data-id=\"94ab6f1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conformit\u00e0 degli strumenti di cella alla norma ISO 7864 <\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-603c5c9 elementor-widget elementor-widget-text-editor\" data-id=\"603c5c9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4230\" data-end=\"4393\">Cell Instruments \u00e8 specializzata in <strong data-start=\"4318\" data-end=\"4349\">soluzioni di test di precisione<\/strong> per i produttori di dispositivi medici, offrendo:<\/p><ul><li data-start=\"4397\" data-end=\"4427\">Tester di penetrabilit\u00e0 ad ago<\/li><li data-start=\"4430\" data-end=\"4463\">Tester universale di resistenza al legame<\/li><li data-start=\"4466\" data-end=\"4505\">Sistemi di test di funzionalit\u00e0 delle siringhe<\/li><li data-start=\"4508\" data-end=\"4576\">Dispositivi personalizzati per la compatibilit\u00e0 con il Luer lock e la tenuta dell'ago<\/li><li data-start=\"4579\" data-end=\"4637\">Aggiornamenti dell'automazione per <strong data-start=\"4603\" data-end=\"4635\">ripetibilit\u00e0 e produttivit\u00e0<\/strong><\/li><\/ul><p data-start=\"4639\" data-end=\"4842\">Tutti gli strumenti sono costruiti per allinearsi con <strong data-start=\"4679\" data-end=\"4691\">ISO 7864<\/strong>, <strong data-start=\"4693\" data-end=\"4705\">ISO 8537<\/strong>, <a href=\"https:\/\/www.pharmacopoeiatest.com\/it\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"4707\" data-end=\"4719\">ISO 7886<\/strong><\/a>, e <strong data-start=\"4725\" data-end=\"4736\">USP 381<\/strong> standard. I nostri sistemi supportano analisi statistiche, esportazione di dati e certificati di calibrazione tracciabili.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0546b7e elementor-widget elementor-widget-heading\" data-id=\"0546b7e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Domande frequenti<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3b149b elementor-widget elementor-widget-toggle\" data-id=\"f3b149b\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2551\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2551\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">1. Che cos'\u00e8 la norma ISO 7864?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2551\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2551\"><p data-start=\"5830\" data-end=\"6017\"><a href=\"https:\/\/www.iso.org\/standard\/60481.html\" target=\"_blank\" rel=\"noopener\">ISO 7864<\/a> specifica i requisiti e i metodi di prova per gli aghi ipodermici sterili monouso. Il documento riguarda le dimensioni fisiche, i materiali e i test di prestazione.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2552\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2552\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">2. Cosa comporta il test di funzionalit\u00e0 della siringa?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2552\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2552\"><p data-start=\"6019\" data-end=\"6226\">Valuta l'interazione tra la siringa e l'ago, compresa la forza di iniezione, la tenuta e la facilit\u00e0 d'uso per garantire un funzionamento coerente e sicuro.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2553\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2553\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">3. Come viene eseguito il test di penetrabilit\u00e0?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2553\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2553\"><p data-start=\"6228\" data-end=\"6415\">Un ago viene inserito in un materiale standardizzato a 100 mm\/min. Vengono registrate le forze di picco e di trascinamento per valutare l'affilatura e le prestazioni.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2554\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2554\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">4. Che cosa viene misurato nel test di resistenza dell'ago?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2554\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2554\"><p data-start=\"6417\" data-end=\"6591\">La forza di trazione necessaria per staccare l'ago dal mozzo. Verifica l'integrit\u00e0 meccanica sotto sforzo.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2555\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2555\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">5. Quali strumenti possono contribuire alla conformit\u00e0 alla norma ISO 7864?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2555\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2555\"><p data-start=\"6593\" data-end=\"6806\">Cell Instruments automatizzato\u00a0<strong data-start=\"6683\" data-end=\"6708\">tester di penetrabilit\u00e0<\/strong>\u00a0e\u00a0<strong data-start=\"6713\" data-end=\"6742\">tester di trazione universale<\/strong>\u00a0sono ideali per la valutazione di aghi e siringhe conformi alla norma ISO 7864.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7864 Hypodermic Syringe Functionality Testing When it comes to sterile hypodermic needles, patient safety and product performance are non-negotiable. That\u2019s where ISO 7864 plays a vital role. This international standard outlines comprehensive requirements and test methods to evaluate hypodermic needles for single-use syringes, including syringe functionality testing, needle penetration test method, and strength of [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[93,92],"class_list":["post-2197","post","type-post","status-publish","format-standard","hentry","category-blog","tag-iso-7864","tag-standards"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/it\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 7864 Hypodermic Syringe Functionality Testing When it comes to sterile hypodermic needles, patient safety and product performance are non-negotiable. That\u2019s where ISO 7864 plays a vital role. This international standard outlines comprehensive requirements and test methods to evaluate hypodermic needles for single-use syringes, including syringe functionality testing, needle penetration test method, and strength of&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/posts\/2197","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/comments?post=2197"}],"version-history":[{"count":4,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/posts\/2197\/revisions"}],"predecessor-version":[{"id":2203,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/posts\/2197\/revisions\/2203"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/media?parent=2197"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/categories?post=2197"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/tags?post=2197"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}