{"id":2059,"date":"2025-04-22T02:54:20","date_gmt":"2025-04-22T02:54:20","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2059"},"modified":"2025-04-22T03:29:50","modified_gmt":"2025-04-22T03:29:50","slug":"flange-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/it\/flange-breakage-resistance-iso-11040-4\/","title":{"rendered":"Resistenza alla rottura delle flange - ISO 11040-4 Allegato C1"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2059\" class=\"elementor elementor-2059\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99d088f e-flex e-con-boxed e-con e-parent\" data-id=\"99d088f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-43cc8ff elementor-widget elementor-widget-heading\" data-id=\"43cc8ff\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Resistenza alla rottura della flangia<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9d7284 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"f9d7284\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1129df5 elementor-widget elementor-widget-heading\" data-id=\"1129df5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Allegato C1<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b7ccfb2 e-flex e-con-boxed e-con e-parent\" data-id=\"b7ccfb2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-254e154 elementor-widget elementor-widget-text-editor\" data-id=\"254e154\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"477\" data-end=\"932\"><em data-start=\"477\" data-end=\"505\">Resistenza alla rottura della flangia<\/em> \u00e8 un attributo di qualit\u00e0 fondamentale nella produzione di siringhe preriempite. Questo test determina la resistenza meccanica della flangia del cilindro della siringa, la parte che deve resistere alle forze applicate durante l'uso clinico. Con l'inasprimento delle normative sanitarie a livello globale, il rispetto degli standard di prestazione meccanica delineati in <a href=\"https:\/\/www.pharmacopoeiatest.com\/it\/flange-breakage-resistance-iso-11040-4\/\"><strong data-start=\"819\" data-end=\"843\">ISO 11040-4 Allegato C1<\/strong><\/a> \u00e8 essenziale per i produttori di siringhe di vetro e di siringhe sterilizzate sotto forma di sottogruppi.<\/p><p class=\"\" data-start=\"934\" data-end=\"1146\">Cell Instruments, leader nel settore delle apparecchiature di prova di precisione, offre soluzioni robuste per garantire che i vostri <em data-start=\"1037\" data-end=\"1054\">test con siringa<\/em> \u00e8 conforme agli standard internazionali, massimizzando l'accuratezza e l'efficienza operativa.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ededb4f elementor-widget elementor-widget-heading\" data-id=\"ededb4f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 e la sua applicazione ai test su siringa<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1f63cd elementor-widget elementor-widget-text-editor\" data-id=\"a1f63cd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1223\" data-end=\"1586\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/it\/iso-11040-4\/\"><strong data-start=\"1223\" data-end=\"1238\">ISO 11040-4<\/strong><\/a> regolamenta i barili di vetro per prodotti iniettabili, concentrandosi in particolare sull'integrit\u00e0 strutturale e sulla funzionalit\u00e0. In <em data-start=\"1346\" data-end=\"1368\">ISO 11040-4 Allegato C1<\/em>, sono previste linee guida specifiche per la valutazione <em data-start=\"1418\" data-end=\"1446\">resistenza alla rottura della flangia<\/em>. L'obiettivo di questo test \u00e8 simulare le condizioni in cui la flangia di una siringa potrebbe rompersi durante la manipolazione o i processi di riempimento automatizzati.<\/p><p class=\"\" data-start=\"1588\" data-end=\"1752\">Lo standard si applica non solo ai barili di siringa finali, ma anche alle siringhe sterilizzate e sub-assemblate pronte per il riempimento, garantendo la coerenza lungo tutta la catena di fornitura.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d261813 elementor-widget elementor-widget-heading\" data-id=\"d261813\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Perch\u00e9 i test di resistenza alla rottura delle flange sono importanti<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f45136 elementor-widget elementor-widget-text-editor\" data-id=\"3f45136\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1811\" data-end=\"2112\">Le siringhe sono sottoposte a numerose sollecitazioni meccaniche durante il trasporto, lo stoccaggio, il riempimento e la somministrazione. La flangia, un componente strutturale all'estremit\u00e0 del cilindro della siringa, \u00e8 un noto punto debole. Se la flangia si rompe, pu\u00f2 compromettere la sterilit\u00e0, l'accuratezza del dosaggio e, in ultima analisi, la sicurezza del paziente.<\/p><p class=\"\" data-start=\"2114\" data-end=\"2168\">Preciso <em data-start=\"2123\" data-end=\"2151\">resistenza alla rottura della flangia<\/em> I test sono utili:<\/p><ul><li data-start=\"2171\" data-end=\"2216\">Convalidare i processi di progettazione e produzione<\/li><li data-start=\"2171\" data-end=\"2216\">Soddisfare la conformit\u00e0 normativa<\/li><li data-start=\"2171\" data-end=\"2216\">Ridurre il rischio di guasto del prodotto sul campo<\/li><li data-start=\"2171\" data-end=\"2216\">Creare fiducia con gli enti normativi e i clienti<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fd48bf elementor-widget elementor-widget-heading\" data-id=\"3fd48bf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Allegato C1 Metodo di prova della resistenza alla rottura delle flange<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ef26935 e-con-full e-flex e-con e-child\" data-id=\"ef26935\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-25fc654 e-con-full e-flex e-con e-child\" data-id=\"25fc654\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1372d22 elementor-widget elementor-widget-heading\" data-id=\"1372d22\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00c8 necessario un tester per la resistenza alla rottura della flangia<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3c025e elementor-widget elementor-widget-text-editor\" data-id=\"c3c025e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2399\" data-end=\"2565\">Il metodo delineato in <strong data-start=\"2422\" data-end=\"2446\">ISO 11040-4 Allegato C1<\/strong> consiste nell'applicare una forza di compressione controllata alla flangia del cilindro della siringa fino a quando non si rompe. Ecco come si fa:<\/p><ul data-start=\"2590\" data-end=\"2834\"><li class=\"\" data-start=\"2590\" data-end=\"2707\"><p class=\"\" data-start=\"2592\" data-end=\"2707\"><strong data-start=\"2592\" data-end=\"2645\">Macchina universale per prove di trazione e compressione<\/strong> (ad esempio, Cell Instruments <em>Tester per siringhe<\/em>)<\/p><\/li><li class=\"\" data-start=\"2708\" data-end=\"2766\"><p class=\"\" data-start=\"2710\" data-end=\"2766\"><strong data-start=\"2710\" data-end=\"2728\">Porta siringhe<\/strong> in materiale adatto, come il PEEK<\/p><\/li><li class=\"\" data-start=\"2767\" data-end=\"2834\"><p class=\"\" data-start=\"2769\" data-end=\"2834\"><strong data-start=\"2769\" data-end=\"2784\">Perno di carico<\/strong>, preferibilmente poliacetale con anima in acciaio inossidabile<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1e99e9 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"a1e99e9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"Test di tenuta delle siringhe ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d45498c e-con-full e-flex e-con e-child\" data-id=\"d45498c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-91d25ab elementor-widget elementor-widget-heading\" data-id=\"91d25ab\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Allegato C1 Procedura di prova<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-922228a elementor-widget elementor-widget-text-editor\" data-id=\"922228a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2858\" data-end=\"2884\"><strong data-start=\"2858\" data-end=\"2882\">1. Preparazione dei campioni di prova<br \/><\/strong><span style=\"font-size: 16px;\">Evitare le scosse di pre-test. Ispezionare visivamente ogni siringa e il supporto per verificare che non siano danneggiati.<\/span><\/p><p class=\"\" data-start=\"2975\" data-end=\"2986\"><strong data-start=\"2975\" data-end=\"2984\">2. Configurazione della macchina di prova<br \/><\/strong><span style=\"font-size: 16px;\">Inserire il cilindro della siringa nel supporto. Allineare il perno di caricamento vicino alla spalla della siringa, come indicato in <\/span><strong style=\"font-size: 16px;\" data-start=\"3091\" data-end=\"3105\">Figura C.2<\/strong><span style=\"font-size: 16px;\"> dello standard ISO.<\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c20220 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"1c20220\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"451\" height=\"297\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Annex-C1.png\" class=\"attachment-large size-large wp-image-2064\" alt=\"ISO 11040-4 Allegato C1 Resistenza alla rottura della flangia\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Annex-C1.png 451w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Annex-C1-300x198.png 300w\" sizes=\"(max-width: 451px) 100vw, 451px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bc0e73 elementor-widget elementor-widget-text-editor\" data-id=\"0bc0e73\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3131\" data-end=\"3151\"><strong data-start=\"3131\" data-end=\"3149\">3. Esecuzione dei test<\/strong><\/p><ul><li data-start=\"3131\" data-end=\"3151\">Impostare la velocit\u00e0 della macchina su <strong data-start=\"3182\" data-end=\"3196\">100 mm\/min<\/strong> (o per accordo).<\/li><li data-start=\"3131\" data-end=\"3151\">Avviare il test e applicare la forza fino alla rottura della flangia.<\/li><li data-start=\"3131\" data-end=\"3151\">Record <strong style=\"font-size: 16px;\" data-start=\"3302\" data-end=\"3328\">forza vs. spostamento<\/strong><span style=\"font-size: 16px;\"> per creare una curva.<\/span><\/li><\/ul><p class=\"\" data-start=\"3131\" data-end=\"3151\"><strong data-start=\"3352\" data-end=\"3369\">4. Analisi dei dati<br \/><\/strong>Individuare il picco di forza dalla curva: questo valore rappresenta il <em data-start=\"3442\" data-end=\"3470\">resistenza alla rottura della flangia<\/em>.<\/p><p class=\"\" data-start=\"3478\" data-end=\"3493\"><strong data-start=\"3478\" data-end=\"3491\">5. Rendicontazione<br \/><\/strong><span style=\"font-size: 16px;\">Includere la velocit\u00e0 del test, il numero di campioni, i valori di picco ed eventuali anomalie. Assicurarsi che la documentazione sia conforme ai requisiti di tracciabilit\u00e0 ISO.<\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9006f3 elementor-widget elementor-widget-heading\" data-id=\"a9006f3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tester a siringa di Cell Instruments<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e501b92 e-con-full e-flex e-con e-child\" data-id=\"e501b92\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7a2147d e-con-full e-flex e-con e-child\" data-id=\"7a2147d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-67dcd66 elementor-widget elementor-widget-heading\" data-id=\"67dcd66\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Vantaggi chiave della macchina di prova a siringa<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb2553c elementor-widget elementor-widget-text-editor\" data-id=\"fb2553c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"4049\" data-end=\"4092\">Compatibile con i dispositivi specifici per siringhe<\/li><li data-start=\"4049\" data-end=\"4092\">Grafico in tempo reale della forza-spostamento<\/li><li data-start=\"4049\" data-end=\"4092\">Velocit\u00e0 e intervalli di carico regolabili<\/li><li data-start=\"4049\" data-end=\"4092\">Microstampa incorporata e porta RS232 opzionale per l'esportazione dei dati senza soluzione di continuit\u00e0<\/li><\/ul><p class=\"\" data-start=\"4258\" data-end=\"4427\">La modularit\u00e0 del sistema lo rende ideale per le aziende impegnate in un'attivit\u00e0 completa di <em data-start=\"4336\" data-end=\"4353\">test con siringa<\/em>, tra cui <em data-start=\"4365\" data-end=\"4393\">resistenza alla rottura della flangia<\/em> e altre valutazioni meccaniche.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9b6dbd6 e-con-full e-flex e-con e-child\" data-id=\"9b6dbd6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c4684f elementor-widget elementor-widget-heading\" data-id=\"2c4684f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Migliori pratiche per le macchine di prova a siringa<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f42b687 elementor-widget elementor-widget-text-editor\" data-id=\"f42b687\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"4495\" data-end=\"4556\"><strong data-start=\"4495\" data-end=\"4526\">Utilizzare un campionamento ad alta frequenza<\/strong> (\u2265500 Hz) per la precisione del picco<\/li><li data-start=\"4495\" data-end=\"4556\"><strong style=\"font-size: 16px;\" data-start=\"4559\" data-end=\"4584\">Verificare l'allineamento del test<\/strong><span style=\"font-size: 16px;\"> prima di ogni esecuzione per evitare false letture<\/span><\/li><li data-start=\"4495\" data-end=\"4556\"><strong style=\"font-size: 16px;\" data-start=\"4629\" data-end=\"4655\">Sostituzione dei componenti usurati<\/strong><span style=\"font-size: 16px;\"> (perno di caricamento, supporto) regolarmente per mantenere la coerenza<\/span><\/li><li data-start=\"4495\" data-end=\"4556\"><strong style=\"font-size: 16px;\" data-start=\"4716\" data-end=\"4739\">Documentate tutto<\/strong><span style=\"font-size: 16px;\">anche piccole deviazioni, per migliorare la rintracciabilit\u00e0<\/span><\/li><li data-start=\"4495\" data-end=\"4556\"><strong style=\"font-size: 16px;\" data-start=\"4792\" data-end=\"4822\">Collaborare con i clienti<\/strong><span style=\"font-size: 16px;\"> concordare la velocit\u00e0 dei test e la calibrazione delle apparecchiature<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20579e3 elementor-widget elementor-widget-text-editor\" data-id=\"20579e3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4897\" data-end=\"5170\">Il test di resistenza alla rottura della flangia non \u00e8 solo una casella di controllo della conformit\u00e0, ma \u00e8 una parte vitale della garanzia di qualit\u00e0 del prodotto per i produttori di siringhe. Allineando le pratiche di test con <strong data-start=\"5075\" data-end=\"5099\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Allegato C1<\/strong>\u00e8 possibile garantire la durata del prodotto, la sicurezza e l'accettazione delle normative.<\/p><p class=\"\" data-start=\"5172\" data-end=\"5418\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/it\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5172\" data-end=\"5192\">Strumenti a cella<\/strong><\/a> \u00e8 il vostro partner di fiducia per raggiungere l'eccellenza nei test. Il nostro <strong>Tester per siringhe<\/strong>\u00a0aiuta a semplificare i flussi di lavoro di analisi delle siringhe, garantendo al contempo l'accuratezza e la conformit\u00e0 richieste dai moderni standard sanitari.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3e233b elementor-widget elementor-widget-text-editor\" data-id=\"b3e233b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\">Lasciateci sostenere il vostro percorso verso prodotti ad alte prestazioni e conformi alle normative.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Flange Breakage Resistance ISO 11040-4 Annex C1 Flange breakage resistance is a critical quality attribute in prefilled syringe manufacturing. This test determines the mechanical strength of the syringe barrel\u2019s flange\u2014the portion that must withstand applied forces during clinical use. As healthcare regulations tighten globally, meeting the mechanical performance standards outlined in ISO 11040-4 Annex C1 [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2059","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/it\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Flange Breakage Resistance ISO 11040-4 Annex C1 Flange breakage resistance is a critical quality attribute in prefilled syringe manufacturing. This test determines the mechanical strength of the syringe barrel\u2019s flange\u2014the portion that must withstand applied forces during clinical use. As healthcare regulations tighten globally, meeting the mechanical performance standards outlined in ISO 11040-4 Annex C1&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/posts\/2059","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/comments?post=2059"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/posts\/2059\/revisions"}],"predecessor-version":[{"id":2072,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/posts\/2059\/revisions\/2072"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/media?parent=2059"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/categories?post=2059"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/it\/wp-json\/wp\/v2\/tags?post=2059"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}