{"id":2225,"date":"2025-07-17T03:26:50","date_gmt":"2025-07-17T03:26:50","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2225"},"modified":"2025-07-17T03:32:17","modified_gmt":"2025-07-17T03:32:17","slug":"break-loose-and-glide-force-testing","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/id\/break-loose-and-glide-force-testing\/","title":{"rendered":"Pengujian Kekuatan Pecah dan Gaya Luncur untuk Kertas: ISO 7886 &amp; Evaluasi Jarum Suntik"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2225\" class=\"elementor elementor-2225\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9145dad e-flex e-con-boxed e-con e-parent\" data-id=\"9145dad\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a89c638 elementor-widget elementor-widget-heading\" data-id=\"a89c638\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pengujian Gaya Lepas dan Gaya Luncur: Indikator Utama Kinerja Jarum Suntik<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b6a1371 e-flex e-con-boxed e-con e-parent\" data-id=\"b6a1371\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-693eb6e elementor-widget elementor-widget-text-editor\" data-id=\"693eb6e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"538\" data-end=\"945\">Dalam industri farmasi dan perangkat medis, <strong data-start=\"591\" data-end=\"630\">pengujian gaya lepas dan meluncur<\/strong> adalah prosedur penting yang digunakan untuk mengevaluasi kegunaan dan kualitas jarum suntik. Pengujian ini menentukan berapa banyak gaya yang diperlukan untuk memulai (melepaskan) dan melanjutkan (meluncur) gerakan plunger di dalam laras jarum suntik. Hasilnya secara langsung berdampak pada kesesuaian produk, kenyamanan penyuntikan, dan keselamatan pasien.<\/p><p data-start=\"947\" data-end=\"1391\">Metode pengujian ini sangat penting bagi produsen yang sedang mengembangkan <strong data-start=\"1016\" data-end=\"1091\">jarum suntik yang telah diisi sebelumnya, sub-rakitan steril, dan komponen injektor otomatis<\/strong>. Plunger yang terlalu kencang atau longgar dapat menyebabkan kesalahan dosis, pelepasan plunger, atau aliran obat yang tidak konsisten-yang semuanya menimbulkan risiko keselamatan. Untuk alasan ini, proses pengujian diuraikan dengan jelas dalam beberapa standar internasional, termasuk <strong data-start=\"1341\" data-end=\"1355\">ISO 7886-1<\/strong>, <strong data-start=\"1357\" data-end=\"1372\">ISO 11040-4<\/strong>dan <strong data-start=\"1378\" data-end=\"1390\">ISO 8537<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ee73ce6 e-flex e-con-boxed e-con e-parent\" data-id=\"ee73ce6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7316cbe elementor-widget elementor-widget-heading\" data-id=\"7316cbe\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pengujian Gaya Luncur Jarum Suntik dan Standar Kepatuhan Internasional<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4fe64ba e-flex e-con-boxed e-con e-parent\" data-id=\"4fe64ba\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-697f2ea elementor-widget elementor-widget-text-editor\" data-id=\"697f2ea\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1470\" data-end=\"1745\">Badan pengatur telah menetapkan persyaratan ketat untuk memastikan kinerja jarum suntik dapat diandalkan dan dapat direproduksi. <strong data-start=\"1585\" data-end=\"1616\">Pengujian gaya luncur jarum suntik<\/strong> mengevaluasi perilaku gesekan dalam kondisi tertentu, dengan tujuan untuk mendeteksi variasi pelumasan atau sifat material.<\/p><p data-start=\"1747\" data-end=\"2087\"><strong data-start=\"1747\" data-end=\"1761\">ISO 7886-1<\/strong><br data-start=\"1761\" data-end=\"1764\" \/>Standar ini berlaku untuk <strong data-start=\"1789\" data-end=\"1820\">jarum suntik steril sekali pakai<\/strong>. Ini mendefinisikan metode pengukuran gaya untuk nilai lepas dan luncur, yang harus tetap berada dalam rentang yang telah ditetapkan sebelumnya untuk menjamin pengoperasian yang lancar. Kecepatan uji yang biasanya digunakan adalah <strong data-start=\"2010\" data-end=\"2024\">100 mm\/menit<\/strong>dan akuisisi data frekuensi tinggi (\u2265500 Hz) direkomendasikan.<\/p><p data-start=\"2089\" data-end=\"2451\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/id\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"2089\" data-end=\"2104\">ISO 11040-4<\/strong><\/a><br data-start=\"2104\" data-end=\"2107\" \/>Berfokus pada <strong data-start=\"2118\" data-end=\"2158\">tong kaca untuk jarum suntik yang sudah diisi sebelumnya<\/strong>standar ini meliputi <strong data-start=\"2183\" data-end=\"2194\">Lampiran E<\/strong>yang menetapkan metode uji gaya luncur untuk sub-rakitan steril. Ini menguraikan persyaratan untuk <strong data-start=\"2300\" data-end=\"2366\">sumbat pendorong, bagian dalam laras, dan pelumasan minyak silikon<\/strong>. Gesekan rendah yang konsisten sangat penting untuk memenuhi kriteria yang ditetapkan dalam standar ini.<\/p><p data-start=\"2453\" data-end=\"2717\"><strong data-start=\"2453\" data-end=\"2465\">ISO 8537<\/strong><br data-start=\"2465\" data-end=\"2468\" \/>Dirancang untuk <strong data-start=\"2481\" data-end=\"2501\">jarum suntik insulin<\/strong>standar ini menekankan pemberian dosis yang akurat melalui kontrol gerakan plunger. Resistensi luncur sangat penting pada alat pengantaran insulin, di mana laju injeksi yang stabil memastikan manajemen glukosa yang aman.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f96e75b e-flex e-con-boxed e-con e-parent\" data-id=\"f96e75b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab96e67 elementor-widget elementor-widget-heading\" data-id=\"ab96e67\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prosedur dan Parameter Uji<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e898377 e-flex e-con-boxed e-con e-parent\" data-id=\"e898377\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6c4a14 elementor-widget elementor-widget-text-editor\" data-id=\"e6c4a14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2760\" data-end=\"2842\">Prosedur untuk pengujian gaya lepas dan gaya luncur mengikuti format yang terstruktur:<\/p><ol data-start=\"2844\" data-end=\"3739\"><li data-start=\"2844\" data-end=\"2990\"><p data-start=\"2847\" data-end=\"2990\"><strong data-start=\"2847\" data-end=\"2862\">Persiapan<\/strong><br data-start=\"2862\" data-end=\"2865\" \/>Gunakan <strong data-start=\"2872\" data-end=\"2901\">jarum suntik kosong yang disterilkan<\/strong> siap untuk diisi. Pasang penghenti plunger yang kompatibel dengan tingkat pelumasan yang ditentukan.<\/p><\/li><li data-start=\"2992\" data-end=\"3220\"><p data-start=\"2995\" data-end=\"3220\"><strong data-start=\"2995\" data-end=\"3004\">Pengaturan<\/strong><br data-start=\"3004\" data-end=\"3007\" \/>Tempatkan jarum suntik dalam mesin uji universal atau peralatan khusus seperti <strong data-start=\"3094\" data-end=\"3155\">Instrumen Sel SSR-01 Penguji Resistensi Geser Jarum Suntik<\/strong>. Amankan dengan penyelarasan perlengkapan yang tepat untuk memastikan gerakan aksial.<\/p><\/li><li data-start=\"3222\" data-end=\"3419\"><p data-start=\"3225\" data-end=\"3419\"><strong data-start=\"3225\" data-end=\"3238\">Eksekusi<\/strong><br data-start=\"3238\" data-end=\"3241\" \/>Memulai gerakan pendorong pada 100 mm\/menit. Peralatan pengujian mencatat <strong data-start=\"3319\" data-end=\"3355\">kekuatan lepas (puncak awal)<\/strong> dan <strong data-start=\"3364\" data-end=\"3418\">gaya luncur (gaya rata-rata selama gerakan lanjutan)<\/strong>.<\/p><\/li><li data-start=\"3421\" data-end=\"3597\"><p data-start=\"3424\" data-end=\"3472\"><strong data-start=\"3424\" data-end=\"3440\">Pengambilan Data<\/strong><br data-start=\"3440\" data-end=\"3443\" \/>Catat data penting termasuk:<\/p><ul data-start=\"3476\" data-end=\"3597\"><li data-start=\"3476\" data-end=\"3500\"><p data-start=\"3478\" data-end=\"3500\">Gaya lepas (f\u2080)<\/p><\/li><li data-start=\"3504\" data-end=\"3526\"><p data-start=\"3506\" data-end=\"3526\">Gaya luncur rata-rata (F)<\/p><\/li><li data-start=\"3530\" data-end=\"3558\"><p data-start=\"3532\" data-end=\"3558\">Gaya luncur maksimum (F\u2098\u2090\u2093)<\/p><\/li><li data-start=\"3562\" data-end=\"3597\"><p data-start=\"3564\" data-end=\"3597\">Jarak tempuh dan durasi pengujian<\/p><\/li><\/ul><\/li><li data-start=\"3599\" data-end=\"3739\"><p data-start=\"3602\" data-end=\"3739\"><strong data-start=\"3602\" data-end=\"3616\">Evaluasi<\/strong><br data-start=\"3616\" data-end=\"3619\" \/>Hasil dibandingkan dengan batas spesifikasi dalam ISO 7886-1, ISO 11040-4, atau ISO 8537, tergantung pada jenis jarum suntik.<\/p><\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94fd533 e-flex e-con-boxed e-con e-parent\" data-id=\"94fd533\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f724e30 elementor-widget elementor-widget-heading\" data-id=\"f724e30\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Masalah Umum yang Terdeteksi Melalui Pengujian Gaya Luncur<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-422d4c4 e-flex e-con-boxed e-con e-parent\" data-id=\"422d4c4\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbff8ed elementor-widget elementor-widget-text-editor\" data-id=\"dbff8ed\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3802\" data-end=\"3888\">Pengujian gaya lepas dan luncur mengungkap masalah kualitas jarum suntik yang kritis, seperti:<\/p><ul data-start=\"3890\" data-end=\"4134\"><li data-start=\"3890\" data-end=\"3961\"><p data-start=\"3892\" data-end=\"3961\"><strong data-start=\"3892\" data-end=\"3914\">Gesekan yang berlebihan<\/strong> dari lapisan silikon yang tidak mencukupi atau tidak rata<\/p><\/li><li data-start=\"3962\" data-end=\"4012\"><p data-start=\"3964\" data-end=\"4012\"><strong data-start=\"3964\" data-end=\"3985\">Menempelkan plunger<\/strong>mempengaruhi akurasi dosis<\/p><\/li><li data-start=\"4013\" data-end=\"4072\"><p data-start=\"4015\" data-end=\"4072\"><strong data-start=\"4015\" data-end=\"4043\">Ketidakcocokan material<\/strong> antara laras dan plunger<\/p><\/li><li data-start=\"4073\" data-end=\"4134\"><p data-start=\"4075\" data-end=\"4134\"><strong data-start=\"4075\" data-end=\"4100\">Pemutusan plunger<\/strong> atau kebocoran segel di bawah gaya aksial<\/p><\/li><\/ul><p data-start=\"4136\" data-end=\"4237\">Mengidentifikasi masalah ini selama penelitian dan pengembangan atau produksi akan melindungi proses hilir dan hasil akhir pasien.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-358cd95 e-flex e-con-boxed e-con e-parent\" data-id=\"358cd95\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1be87be elementor-widget elementor-widget-heading\" data-id=\"1be87be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Peralatan yang Direkomendasikan: Instrumen Sel Instrumen SSR-01 Penguji Resistensi Geser Jarum Suntik<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-97d0577 e-flex e-con-boxed e-con e-parent\" data-id=\"97d0577\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4f6c718 e-con-full e-flex e-con e-child\" data-id=\"4f6c718\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-495d6e6 elementor-widget elementor-widget-text-editor\" data-id=\"495d6e6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4330\" data-end=\"4474\">Untuk melaksanakan pengujian ini secara akurat dan sesuai dengan standar ISO, Cell Instruments menawarkan<a href=\"https:\/\/www.pharmacopoeiatest.com\/id\/syringes-plunger-glide-force-tester\/\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"4430\" data-end=\"4440\">SSR-01<\/strong><\/a>. Instrumen ini dirancang untuk:<\/p><ul data-start=\"4476\" data-end=\"4766\"><li data-start=\"4476\" data-end=\"4534\"><p data-start=\"4478\" data-end=\"4534\"><strong data-start=\"4478\" data-end=\"4501\">Pengukuran yang tepat<\/strong> dari gaya lepas dan meluncur<\/p><\/li><li data-start=\"4535\" data-end=\"4596\"><p data-start=\"4537\" data-end=\"4596\"><strong data-start=\"4537\" data-end=\"4563\">Kecepatan uji yang dapat disesuaikan<\/strong> dan pengaturan pengujian yang dapat diprogram<\/p><\/li><li data-start=\"4597\" data-end=\"4657\"><p data-start=\"4599\" data-end=\"4657\"><strong data-start=\"4599\" data-end=\"4625\">Tampilan data waktu nyata<\/strong> melalui layar sentuh HMI 7 inci<\/p><\/li><li data-start=\"4658\" data-end=\"4712\"><p data-start=\"4660\" data-end=\"4712\"><strong data-start=\"4660\" data-end=\"4686\">Printer mikro internal<\/strong> untuk pelaporan segera<\/p><\/li><li data-start=\"4713\" data-end=\"4766\"><p data-start=\"4715\" data-end=\"4766\"><strong data-start=\"4715\" data-end=\"4736\">Perlengkapan yang fleksibel<\/strong> untuk format jarum suntik yang berbeda<\/p><\/li><\/ul><p data-start=\"4768\" data-end=\"4893\">Antarmuka yang intuitif dan kinerja yang tangguh membuatnya ideal untuk keduanya <strong data-start=\"4838\" data-end=\"4859\">jaminan kualitas<\/strong> dan <strong data-start=\"4864\" data-end=\"4892\">laboratorium pengembangan produk<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7285d35 e-con-full e-flex e-con e-child\" data-id=\"7285d35\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f5e0678 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"f5e0678\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp\" class=\"attachment-medium_large size-medium_large wp-image-2227\" alt=\"Mesin Uji Gaya Lepas dan Luncur - solusi serbaguna dan presisi tinggi yang disesuaikan untuk pengujian jarum suntik dan bahan kemasan.\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-1024x1024.webp 1024w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1.webp 1080w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d9ef370 e-flex e-con-boxed e-con e-parent\" data-id=\"d9ef370\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-354bdaf elementor-widget elementor-widget-heading\" data-id=\"354bdaf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mengapa Pengujian Ini Penting bagi Produsen<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9e66002 e-flex e-con-boxed e-con e-parent\" data-id=\"9e66002\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-aae1c87 e-con-full e-flex e-con e-child\" data-id=\"aae1c87\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf49733 elementor-widget elementor-widget-video\" data-id=\"bf49733\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=Jv55XhLaURk&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;modestbranding&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2cf2943 e-con-full e-flex e-con e-child\" data-id=\"2cf2943\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c0dc11 elementor-widget elementor-widget-text-editor\" data-id=\"0c0dc11\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"4948\" data-end=\"5007\"><p data-start=\"4950\" data-end=\"5007\"><strong data-start=\"4950\" data-end=\"4981\">Mendukung pengajuan peraturan<\/strong> dengan data yang sesuai dengan ISO<\/p><\/li><li data-start=\"5008\" data-end=\"5082\"><p data-start=\"5010\" data-end=\"5082\"><strong data-start=\"5010\" data-end=\"5040\">Meningkatkan kegunaan produk<\/strong> dengan menghilangkan aliran yang lengket atau tidak menentu<\/p><\/li><li data-start=\"5083\" data-end=\"5144\"><p data-start=\"5085\" data-end=\"5144\"><strong data-start=\"5085\" data-end=\"5115\">Meningkatkan keseragaman batch<\/strong> untuk produksi bervolume tinggi<\/p><\/li><li data-start=\"5145\" data-end=\"5201\"><p data-start=\"5147\" data-end=\"5201\"><strong data-start=\"5147\" data-end=\"5173\">Mengurangi risiko penarikan kembali<\/strong> karena kegagalan mekanis<\/p><\/li><li data-start=\"5202\" data-end=\"5283\"><p data-start=\"5204\" data-end=\"5283\"><strong data-start=\"5204\" data-end=\"5232\">Meningkatkan kenyamanan pasien<\/strong>, terutama untuk alat suntik otomatis dan jarum suntik insulin<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0c0191b e-flex e-con-boxed e-con e-parent\" data-id=\"0c0191b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4180a60 elementor-widget elementor-widget-heading\" data-id=\"4180a60\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kesimpulan<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fa9b8b6 e-flex e-con-boxed e-con e-parent\" data-id=\"fa9b8b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-28ecdb2 elementor-widget elementor-widget-text-editor\" data-id=\"28ecdb2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5306\" data-end=\"5729\"><strong data-start=\"5306\" data-end=\"5345\">Pengujian kekuatan lepas dan meluncur<\/strong> adalah bagian mendasar dari evaluasi kualitas jarum suntik. Mematuhi <a href=\"https:\/\/www.pharmacopoeiatest.com\/id\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5411\" data-end=\"5425\">ISO 7886-1<\/strong><\/a>, <strong data-start=\"5427\" data-end=\"5442\">ISO 11040-4<\/strong>dan <strong data-start=\"5448\" data-end=\"5460\">ISO 8537<\/strong> memastikan keandalan produk, kepatuhan terhadap peraturan, dan pengiriman obat yang aman. Dengan berinvestasi pada instrumen canggih seperti <strong data-start=\"5583\" data-end=\"5615\">SSR-01 dari<a href=\"https:\/\/www.celtec.cn\" target=\"_blank\" rel=\"noopener\"> Instrumen Sel<\/a><\/strong>, produsen dapat dengan yakin memberikan jarum suntik berkinerja tinggi yang memenuhi harapan industri dan pasien.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Pengujian Gaya Lepas dan Gaya Luncur: Indikator Utama Kinerja Alat Suntik Dalam industri farmasi dan perangkat medis, pengujian break loose dan glide force merupakan prosedur penting yang digunakan untuk mengevaluasi kegunaan dan kualitas alat suntik. Pengujian ini menentukan seberapa besar gaya yang diperlukan untuk memulai (break loose) dan melanjutkan (glide) gerakan [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2225","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/id\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Break Loose and Glide Force Testing: A Key Indicator of Syringe Performance In the pharmaceutical and medical device industries, break loose and glide force testing is a critical procedure used to evaluate the usability and quality of syringes. These tests determine how much force is required to start (break loose) and continue (glide) the movement&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/2225","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/comments?post=2225"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/2225\/revisions"}],"predecessor-version":[{"id":2251,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/2225\/revisions\/2251"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/media?parent=2225"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/categories?post=2225"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/tags?post=2225"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}