{"id":2087,"date":"2025-04-27T08:38:09","date_gmt":"2025-04-27T08:38:09","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2087"},"modified":"2025-04-27T08:47:19","modified_gmt":"2025-04-27T08:47:19","slug":"luer-lock-rings-pull-off-force-test","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/id\/luer-lock-rings-pull-off-force-test\/","title":{"rendered":"Uji Gaya Tarik Cincin Kunci Luer - ISO 11040-4 Lampiran G3"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2087\" class=\"elementor elementor-2087\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a57182 e-flex e-con-boxed e-con e-parent\" data-id=\"7a57182\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-caf1aa9 elementor-widget elementor-widget-heading\" data-id=\"caf1aa9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Gaya Tarik Cincin Kunci Luer<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27efcf2 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"27efcf2\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49edf54 elementor-widget elementor-widget-heading\" data-id=\"49edf54\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Lampiran G3<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-03ddeb3 e-flex e-con-boxed e-con e-parent\" data-id=\"03ddeb3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ccea8f2 elementor-widget elementor-widget-text-editor\" data-id=\"ccea8f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"455\" data-end=\"1006\">Dalam industri farmasi dan alat kesehatan, industri <em data-start=\"531\" data-end=\"563\">gaya tarik cincin kunci luer<\/em> adalah parameter penting untuk memastikan keandalan dan keamanan jarum suntik yang sudah diisi sebelumnya. Pengujian yang tepat akan memverifikasi pemasangan yang aman pada adaptor kunci luer (LLA) untuk mencegah pelepasan yang tidak disengaja selama penggunaan.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c963d8 elementor-widget elementor-widget-heading\" data-id=\"0c963d8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pentingnya Gaya Tarik Cincin Kunci Luer<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee545a5 elementor-widget elementor-widget-text-editor\" data-id=\"ee545a5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1013\" data-end=\"1449\">The <em data-start=\"1076\" data-end=\"1108\">gaya tarik cincin kunci luer<\/em> mengukur kekuatan aksial yang diperlukan untuk melepaskan sistem kerah LLA dari laras jarum suntik. Pengujian yang akurat memastikan jarum suntik mempertahankan integritas selama penanganan, pengisian, dan administrasi, sehingga mengurangi risiko kegagalan perangkat. Standar peraturan mewajibkan pengujian ini untuk melindungi keselamatan pasien dan mendukung klaim kinerja produk.<\/p><p class=\"\" data-start=\"1451\" data-end=\"1734\">Bagi produsen dan lembaga inspeksi kualitas, terutama yang melayani pasar medis, farmasi, dan perawatan kesehatan, menguasai tes ini sangat penting. <strong data-start=\"1610\" data-end=\"1630\">Instrumen Sel<\/strong> menyediakan solusi canggih yang memenuhi persyaratan ketat ini dengan presisi dan keandalan yang tinggi.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4912cb5 elementor-widget elementor-widget-heading\" data-id=\"4912cb5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Persyaratan ISO 11040-4 Lampiran G3<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9bf8207 elementor-widget elementor-widget-text-editor\" data-id=\"9bf8207\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1741\" data-end=\"2070\"><em data-start=\"1838\" data-end=\"1851\">ISO 11040-4<\/em> mendefinisikan persyaratan untuk tong kaca untuk alat suntik dan jarum suntik rakitan yang telah disterilkan dan siap diisi. Secara khusus, <em data-start=\"1981\" data-end=\"2003\">ISO 11040-4 Lampiran G3<\/em> merinci metode untuk mengukur <em data-start=\"2037\" data-end=\"2069\">gaya tarik cincin kunci luer<\/em>.<\/p><p class=\"\" data-start=\"2072\" data-end=\"2096\">Menurut Lampiran G3:<\/p><ul data-start=\"2097\" data-end=\"2989\"><li class=\"\" data-start=\"2097\" data-end=\"2237\"><p class=\"\" data-start=\"2099\" data-end=\"2237\"><strong data-start=\"2099\" data-end=\"2112\">Prinsip<\/strong>: Pengujian ini mengevaluasi apakah sistem LLA dapat menahan gaya tarik aksial yang ditentukan ketika dihubungkan ke fitting luer standar.<\/p><\/li><li class=\"\" data-start=\"2238\" data-end=\"2444\"><p class=\"\" data-start=\"2240\" data-end=\"2444\"><strong data-start=\"2240\" data-end=\"2253\">Peralatan<\/strong>: Diperlukan mesin uji tarik dan kompresi universal, yang mampu beroperasi pada <strong data-start=\"2346\" data-end=\"2373\">kecepatan uji 20 mm\/menit<\/strong>. Sel beban dengan kisaran tipikal <strong data-start=\"2411\" data-end=\"2428\">10 N hingga 100 N<\/strong> harus digunakan.<\/p><\/li><li class=\"\" data-start=\"2445\" data-end=\"2524\"><p class=\"\" data-start=\"2447\" data-end=\"2524\"><strong data-start=\"2447\" data-end=\"2462\">Persiapan<\/strong>: Sampel uji harus sesuai dengan kondisi proses produksi.<\/p><\/li><li class=\"\" data-start=\"2525\" data-end=\"2751\"><p class=\"\" data-start=\"2527\" data-end=\"2751\"><strong data-start=\"2527\" data-end=\"2540\">Prosedur<\/strong>: Setelah melepas tutup ujung, jarum suntik diposisikan di dudukan tanpa memberikan tekanan awal ke LLA. Mesin kemudian menarik dengan kecepatan konstan hingga kerah LLA terlepas, merekam gaya puncak.<\/p><\/li><li class=\"\" data-start=\"2752\" data-end=\"2851\"><p class=\"\" data-start=\"2754\" data-end=\"2851\"><strong data-start=\"2754\" data-end=\"2765\">Hasil<\/strong>: Gaya puncak dari kurva gaya-perpindahan menunjukkan kekuatan tarikan.<\/p><\/li><li class=\"\" data-start=\"2852\" data-end=\"2989\"><p class=\"\" data-start=\"2854\" data-end=\"2989\"><strong data-start=\"2854\" data-end=\"2871\">Dokumentasi<\/strong>: Laporan harus mencakup kecepatan pengujian, nilai puncak, jumlah sampel, hasil lulus\/gagal, dan penyimpangan yang diamati.<\/p><\/li><\/ul><p class=\"\" data-start=\"2991\" data-end=\"3102\">Mengikuti <em data-start=\"3001\" data-end=\"3023\">ISO 11040-4 Lampiran G3<\/em> memastikan bahwa hasilnya dapat diandalkan, dapat direproduksi, dan diterima secara internasional.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd67e63 elementor-widget elementor-widget-heading\" data-id=\"cd67e63\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Cara Melakukan Uji Gaya Tarik Cincin Kunci Luer<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec7a39c elementor-widget elementor-widget-text-editor\" data-id=\"ec7a39c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3109\" data-end=\"3263\">Melakukan pemeriksaan yang akurat <a href=\"https:\/\/www.pharmacopoeiatest.com\/id\/luer-lock-rings-pull-off-force-test\/\"><em data-start=\"3193\" data-end=\"3225\">gaya tarik cincin kunci luer<\/em> tes<\/a> melibatkan beberapa langkah penting:<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-08466dd e-con-full e-flex e-con e-child\" data-id=\"08466dd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-33a3c77 elementor-widget elementor-widget-text-editor\" data-id=\"33a3c77\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>1. Persiapan Sampel<\/strong><\/p><ul><li data-start=\"3292\" data-end=\"3363\">Gunakan jarum suntik rakitan yang telah disterilkan yang sesuai dengan kondisi produksi.<\/li><li data-start=\"3292\" data-end=\"3363\">Lepaskan tutup ujung tanpa menekan sistem kerah LLA.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d451ca elementor-widget elementor-widget-text-editor\" data-id=\"5d451ca\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3427\" data-end=\"3452\"><strong>2. Menyiapkan Tes<\/strong><\/p><ul><li data-start=\"3455\" data-end=\"3551\">Pasang jarum suntik di bagian <strong data-start=\"3480\" data-end=\"3498\">tempat jarum suntik<\/strong> dan kencangkan kerah LLA di bagian <strong data-start=\"3532\" data-end=\"3550\">perangkat gripper<\/strong>.<\/li><li data-start=\"3455\" data-end=\"3551\">Pastikan tidak ada tekanan yang diberikan pada kerah selama pemasangan.<\/li><li data-start=\"3455\" data-end=\"3551\">Kalibrasi sel beban ke \"nol\" tanpa menerapkan prapemuatan.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-95882a3 e-con-full e-flex e-con e-child\" data-id=\"95882a3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b1efd9c elementor-widget elementor-widget-text-editor\" data-id=\"b1efd9c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3675\" data-end=\"3699\"><strong>Menjalankan Tes<\/strong><\/p><ul><li>Atur kecepatan mesin ke <strong data-start=\"3727\" data-end=\"3740\">20 mm\/menit<\/strong>.<\/li><li>Mulai uji tarikan, pantau gaya versus perpindahan.<\/li><li>Catat kekuatan puncak setelah kerah LLA terlepas dari jarum suntik.<\/li><\/ul><p class=\"\" data-start=\"3875\" data-end=\"3902\"><strong data-start=\"3875\" data-end=\"3900\">Menganalisis Hasil<\/strong><\/p><ul><li data-start=\"3905\" data-end=\"3964\">Identifikasi titik tertinggi pada grafik gaya-perpindahan.<\/li><li data-start=\"3905\" data-end=\"3964\">Bandingkan dengan batas yang ditentukan untuk menentukan lulus atau gagal.<\/li><li data-start=\"3905\" data-end=\"3964\">Dokumentasikan semua parameter, termasuk jumlah sampel, kegagalan, dan penyimpangan.<\/li><\/ul><p class=\"\" data-start=\"4110\" data-end=\"4222\">A <strong data-start=\"4112\" data-end=\"4139\">laju pengambilan sampel 500 Hz<\/strong> direkomendasikan untuk memastikan penangkapan pengukuran puncak yang akurat selama pengujian.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37beef7 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"37beef7\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"496\" height=\"500\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp\" class=\"attachment-full size-full wp-image-2089\" alt=\"Uji Gaya Tarik Cincin Kunci Luer - ISO 11040-4 Lampiran G3\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3.webp 496w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-298x300.webp 298w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Lock-Rings-Pull-Off-Force-Test-ISO-11040-4-Annex-G3-150x150.webp 150w\" sizes=\"(max-width: 496px) 100vw, 496px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fe809e1 e-con-full e-flex e-con e-child\" data-id=\"fe809e1\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-517a11d e-con-full e-flex e-con e-child\" data-id=\"517a11d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-661f7f9 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"661f7f9\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"Pengujian kebocoran jarum suntik ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-63b418a e-con-full e-flex e-con e-child\" data-id=\"63b418a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-45b4a2d elementor-widget elementor-widget-heading\" data-id=\"45b4a2d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Peralatan yang Direkomendasikan untuk Pengujian yang Akurat<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef6391d elementor-widget elementor-widget-text-editor\" data-id=\"ef6391d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4229\" data-end=\"4441\">Di <strong data-start=\"4281\" data-end=\"4301\">Instrumen Sel<\/strong>kami mengkhususkan diri dalam menyediakan <strong data-start=\"4330\" data-end=\"4375\">penguji tarik dan kompresi universal<\/strong> disesuaikan untuk aplikasi pengujian jarum suntik. Sistem kami menawarkan:<\/p><ul data-start=\"4442\" data-end=\"4731\"><li class=\"\" data-start=\"4442\" data-end=\"4503\"><p class=\"\" data-start=\"4444\" data-end=\"4503\">Pengambilan sampel frekuensi tinggi (hingga 500 Hz) untuk akurasi puncak.<\/p><\/li><li class=\"\" data-start=\"4504\" data-end=\"4582\"><p class=\"\" data-start=\"4506\" data-end=\"4582\">Tempat jarum suntik khusus dan gripper LLA yang sesuai dengan spesifikasi ISO.<\/p><\/li><li class=\"\" data-start=\"4583\" data-end=\"4658\"><p class=\"\" data-start=\"4585\" data-end=\"4658\">Sel beban cocok untuk berbagai gaya pengujian antara 10 N dan 100 N.<\/p><\/li><li class=\"\" data-start=\"4659\" data-end=\"4731\"><p class=\"\" data-start=\"4661\" data-end=\"4731\">Perangkat lunak intuitif untuk penelusuran parameter penuh dan pelaporan yang mudah.<\/p><\/li><\/ul><p class=\"\" data-start=\"4733\" data-end=\"4901\">Solusi kami menjamin kepatuhan terhadap <em data-start=\"4773\" data-end=\"4786\">ISO 11040-4<\/em> dan membantu memastikan kualitas produk tertinggi bagi pelanggan kami di industri farmasi dan alat kesehatan.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d05f85d elementor-widget elementor-widget-text-editor\" data-id=\"d05f85d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4908\" data-end=\"5324\">Memahami dan mengukur secara akurat <em data-start=\"4968\" data-end=\"5000\">gaya tarik cincin kunci luer<\/em> menurut <em data-start=\"5014\" data-end=\"5036\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Lampiran G3<\/em> sangat penting untuk memastikan keamanan dan keandalan jarum suntik. Dengan mengikuti metode yang benar dan menggunakan instrumen pengujian yang sesuai dan berpresisi tinggi dari <strong data-start=\"5187\" data-end=\"5207\">Instrumen Sel<\/strong>tim kontrol kualitas dapat dengan yakin memverifikasi kinerja produk, memenuhi standar peraturan, dan melindungi pengguna akhir.<\/p><p class=\"\" data-start=\"5326\" data-end=\"5511\">Jika Anda memerlukan bantuan dalam memilih atau menyesuaikan peralatan pengujian yang tepat untuk kebutuhan pengujian jarum suntik Anda, <strong data-start=\"5437\" data-end=\"5471\">hubungi Cell Instruments hari ini<\/strong> untuk menjelajahi berbagai solusi kami.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Gaya Tarik Cincin Kunci Luer ISO 11040-4 Lampiran G3 Dalam industri farmasi dan perangkat medis, gaya tarik cincin kunci luer merupakan parameter penting untuk memastikan keandalan dan keamanan jarum suntik yang telah diisi sebelumnya. Pengujian yang tepat memverifikasi pemasangan yang aman dari adaptor kunci luer (LLA) untuk mencegah pelepasan yang tidak disengaja selama penggunaan. Pentingnya [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2087","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/id\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Lock Rings Pull-Off Force ISO 11040-4 Annex G3 In the pharmaceutical and medical device industries, the luer lock rings pull-off force is a critical parameter to ensure the reliability and safety of prefilled syringes. Proper testing verifies the secure attachment of the luer lock adaptor (LLA) to prevent accidental detachment during use. Importance of&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/2087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/comments?post=2087"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/2087\/revisions"}],"predecessor-version":[{"id":2101,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/2087\/revisions\/2101"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/media?parent=2087"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/categories?post=2087"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/tags?post=2087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}