{"id":2073,"date":"2025-04-22T03:59:40","date_gmt":"2025-04-22T03:59:40","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2073"},"modified":"2025-04-22T06:49:25","modified_gmt":"2025-04-22T06:49:25","slug":"luer-cone-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/id\/luer-cone-breakage-resistance-iso-11040-4\/","title":{"rendered":"Ketahanan Kerusakan Kerucut Luer - ISO 11040-4 Lampiran C2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2073\" class=\"elementor elementor-2073\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef785b6 e-flex e-con-boxed e-con e-parent\" data-id=\"ef785b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d4a251 elementor-widget elementor-widget-heading\" data-id=\"6d4a251\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Ketahanan Kerusakan Kerucut Luer<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b910e1 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8b910e1\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec4bbc1 elementor-widget elementor-widget-heading\" data-id=\"ec4bbc1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Lampiran C2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bdc54b0 e-flex e-con-boxed e-con e-parent\" data-id=\"bdc54b0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a300c79 elementor-widget elementor-widget-text-editor\" data-id=\"a300c79\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"400\" data-end=\"1016\">Dalam pembuatan jarum suntik dan kontrol kualitas, salah satu penilaian mekanis yang paling penting adalah <strong data-start=\"520\" data-end=\"553\">ketahanan kerusakan kerucut luer<\/strong> uji. Integritas struktural ujung depan jarum suntik, terutama kerucut luer, secara langsung berdampak pada keselamatan pasien dan keandalan perangkat. Untuk memastikan evaluasi yang konsisten dan terstandardisasi, proses <em data-start=\"749\" data-end=\"762\">ISO 11040-4<\/em> standar-khusus <em data-start=\"785\" data-end=\"795\">Lampiran C2<\/em>-menguraikan prosedur dan persyaratan untuk melakukan pengujian ini. Artikel ini akan memandu Anda melalui proses pengujian, peralatan penting, dan interpretasi data yang diperlukan untuk mematuhi <a href=\"https:\/\/www.pharmacopoeiatest.com\/id\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> standar pengujian.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3c5bd5 elementor-widget elementor-widget-heading\" data-id=\"b3c5bd5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pentingnya Ketahanan Kerusakan Kerucut Luer<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ddf4e elementor-widget elementor-widget-text-editor\" data-id=\"60ddf4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Kerucut luer, yang terletak di ujung depan laras jarum suntik, merupakan titik lemah potensial yang rentan terhadap tekanan mekanis selama penanganan, perakitan, atau injeksi. <strong data-start=\"1248\" data-end=\"1281\">Ketahanan kerusakan kerucut Luer<\/strong> pengujian membantu menentukan seberapa besar gaya yang dapat ditahan oleh kerucut sebelum retak. Untuk produsen <em data-start=\"1384\" data-end=\"1405\">jarum suntik yang sudah diisi sebelumnya<\/em> dan <em data-start=\"1410\" data-end=\"1441\">tong kaca untuk bahan suntik<\/em>pengujian ini bukan hanya persyaratan peraturan-ini adalah tindakan kontrol kualitas mendasar untuk menghindari kegagalan dalam aplikasi medis.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d476dd elementor-widget elementor-widget-heading\" data-id=\"3d476dd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Lampiran C2 Metode Uji Ketahanan Kerusakan Kerucut Luer<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642e2e7 elementor-widget elementor-widget-text-editor\" data-id=\"642e2e7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1582\" data-end=\"2040\">The <strong data-start=\"1636\" data-end=\"1651\">ISO 11040-4<\/strong> standar, berjudul <em data-start=\"1669\" data-end=\"1784\">Alat Suntik yang Sudah Diisi Sebelumnya - Bagian 4: Tabung kaca untuk alat suntik dan alat suntik rakitan yang sudah disterilkan dan siap untuk diisi<\/em>, termasuk <strong data-start=\"1795\" data-end=\"1807\">Lampiran C2<\/strong>, yang merinci <em data-start=\"1827\" data-end=\"1858\">ketahanan kerusakan ujung depan<\/em> pengujian. Bagian ini menguraikan kondisi di mana pengujian harus dilakukan, termasuk persyaratan peralatan, penanganan spesimen, prosedur pengujian, dan dokumentasi hasil.<\/p><h3 class=\"\" data-start=\"2042\" data-end=\"2077\">Kondisi Pengujian Utama Termasuk:<\/h3><ul><li data-start=\"2080\" data-end=\"2105\">Uji kecepatan: <strong data-start=\"2092\" data-end=\"2105\">25 mm\/menit<\/strong><\/li><li data-start=\"2080\" data-end=\"2105\">Titik aplikasi: <strong style=\"font-size: 16px;\" data-start=\"2127\" data-end=\"2135\">2 mm<\/strong><span style=\"font-size: 16px;\"> dari ujung jarum suntik<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Laju pengambilan sampel minimum: <strong style=\"font-size: 16px;\" data-start=\"2182\" data-end=\"2192\">500 Hz<\/strong><span style=\"font-size: 16px;\"> untuk akurasi pengukuran puncak<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Gaya diterapkan sampai <strong style=\"font-size: 16px;\" data-start=\"2245\" data-end=\"2263\">kerusakan kaca<\/strong><span style=\"font-size: 16px;\"> terjadi<\/span><\/li><\/ul><p class=\"\" data-start=\"2272\" data-end=\"2390\">Dengan mengikuti panduan ini, Anda dapat memastikan bahwa <strong data-start=\"2314\" data-end=\"2333\">pengujian jarum suntik<\/strong> proses tetap dapat dilacak, dapat direproduksi, dan patuh.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4dbc7e2 elementor-widget elementor-widget-heading\" data-id=\"4dbc7e2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Penguji Jarum Suntik untuk Pengujian ISO 11040-4 Lampiran C2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7da5e4d elementor-widget elementor-widget-text-editor\" data-id=\"7da5e4d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2454\" data-end=\"2671\">Untuk melakukan secara akurat <strong data-start=\"2476\" data-end=\"2509\">ketahanan kerusakan kerucut luer<\/strong> tes, Anda akan membutuhkan tes yang andal dan tepat <strong data-start=\"2552\" data-end=\"2605\">mesin uji tarik dan kompresi universal<\/strong>. Peralatan harus memenuhi persyaratan ISO 11040-4 Lampiran C2:<\/p><ul><li data-start=\"2675\" data-end=\"2729\">A <strong data-start=\"2677\" data-end=\"2690\">sel beban<\/strong> cocok untuk mengukur kekuatan kerusakan<\/li><li data-start=\"2675\" data-end=\"2729\">Akurat dan dapat diprogram <strong style=\"font-size: 16px;\" data-start=\"2758\" data-end=\"2780\">kontrol kecepatan uji<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Sebuah kebiasaan <strong style=\"font-size: 16px;\" data-start=\"2792\" data-end=\"2834\">dudukan baja tahan karat dan batang pemuatan<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Set adaptor yang sesuai dengan geometri desain jarum suntik Anda<\/li><\/ul><h3 class=\"\" data-start=\"2889\" data-end=\"2967\">Penguji Jarum Suntik yang Direkomendasikan<\/h3><p class=\"\" data-start=\"2969\" data-end=\"3383\">Instrumen Sel ' <em>Penguji Jarum Suntik<\/em>\u00a0dirancang untuk memenuhi persyaratan pengujian jarum suntik ISO yang ketat. Dilengkapi dengan kontrol PLC yang dapat diprogram, mekanik presisi, dan perlengkapan yang dapat disesuaikan, MPT-01 menyediakan data gaya dan perpindahan resolusi tinggi, sehingga ideal untuk <strong data-start=\"3241\" data-end=\"3274\">ketahanan kerusakan kerucut luer<\/strong> penilaian. Mikroprinter terintegrasi dan ekspor data RS232 opsional juga mendukung dokumentasi yang mendetail.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4ff2b elementor-widget elementor-widget-heading\" data-id=\"6b4ff2b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prosedur Pengujian Ketahanan Kerusakan Kerucut Luer<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c990a3c e-con-full e-flex e-con e-child\" data-id=\"c990a3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-dbcf8eb e-con-full e-flex e-con e-child\" data-id=\"dbcf8eb\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53324d6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"53324d6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"Pengujian kebocoran jarum suntik ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9962325 e-con-full e-flex e-con e-child\" data-id=\"9962325\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea7609b elementor-widget elementor-widget-text-editor\" data-id=\"ea7609b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3460\" data-end=\"3483\"><strong>1. Persiapan Tes<\/strong><\/p><ul><li data-start=\"3486\" data-end=\"3553\">Periksa semua adaptor dan bahan untuk <strong data-start=\"3525\" data-end=\"3552\">kerusakan atau kompatibilitas<\/strong>.<\/li><li data-start=\"3486\" data-end=\"3553\">Pasang adaptor dan perlengkapan yang diperlukan pada <strong style=\"font-size: 16px;\">Penguji Jarum Suntik<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3486\" data-end=\"3553\">Pastikan keselarasan yang tepat dan <strong style=\"font-size: 16px;\" data-start=\"3652\" data-end=\"3677\">memasang pelindung keamanan<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul><p data-start=\"3680\" data-end=\"3704\"><strong>2. Eksekusi Pengujian<\/strong><\/p><ul><li data-start=\"3707\" data-end=\"3749\">Masukkan laras jarum suntik ke dalam dudukannya.<\/li><li data-start=\"3707\" data-end=\"3749\">Posisikan pin pemuatan <strong style=\"font-size: 16px;\" data-start=\"3777\" data-end=\"3806\">2 mm dari ujung jarum suntik<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Atur kecepatan ke <strong style=\"font-size: 16px;\" data-start=\"3827\" data-end=\"3840\">25 mm\/menit<\/strong><span style=\"font-size: 16px;\"> dan memulai pengujian.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Lakukan kompresi sampai kerucut luer <strong style=\"font-size: 16px;\" data-start=\"3901\" data-end=\"3914\">patah tulang<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Rekam <strong style=\"font-size: 16px;\" data-start=\"3929\" data-end=\"3958\">kekuatan maksimum saat kerusakan<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4898eec elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"4898eec\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"272\" height=\"270\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png\" class=\"attachment-large size-large wp-image-2078\" alt=\"Ketahanan Kerusakan Kerucut Luer - ISO 11040-4 Lampiran C2 Pengujian Jarum Suntik\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png 272w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing-150x150.png 150w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322584f elementor-widget elementor-widget-text-editor\" data-id=\"322584f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3961\" data-end=\"3999\"><b>3. Pembersihan dan Analisis Pasca Tes<\/b><\/p><ul><li data-start=\"4002\" data-end=\"4038\">Keluarkan jarum suntik yang rusak dengan hati-hati.<\/li><li data-start=\"4002\" data-end=\"4038\">Bersihkan adaptor untuk menghilangkan serpihan kaca.<\/li><li data-start=\"4002\" data-end=\"4038\">Menganalisis hasil dan mengonfirmasi <strong style=\"font-size: 16px;\" data-start=\"4117\" data-end=\"4138\">lokasi fraktur<\/strong><span style=\"font-size: 16px;\"> di ujung depan.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04ee823 elementor-widget elementor-widget-heading\" data-id=\"04ee823\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Persyaratan Pelaporan Hasil Berdasarkan ISO 11040-4<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a8c95c elementor-widget elementor-widget-text-editor\" data-id=\"9a8c95c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4216\" data-end=\"4286\">Setiap pengujian harus didokumentasikan secara menyeluruh, termasuk data berikut ini:<\/p><ul><li data-start=\"4289\" data-end=\"4313\"><strong data-start=\"4289\" data-end=\"4303\">Uji kecepatan<\/strong> dalam mm\/menit<\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4316\" data-end=\"4349\">Jarak dari ujung jarum suntik<\/strong><span style=\"font-size: 16px;\"> di mana gaya diterapkan<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4383\" data-end=\"4409\">Kekuatan kerusakan maksimum<\/strong><span style=\"font-size: 16px;\"> dalam ton (N)<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4427\" data-end=\"4446\">Jumlah sampel<\/strong><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4449\" data-end=\"4480\">Setiap anomali atau penyimpangan<\/strong><span style=\"font-size: 16px;\"> dari prosedur<\/span><\/li><\/ul><p class=\"\" data-start=\"4501\" data-end=\"4652\">Tingkat detail ini memastikan konsistensi dan memungkinkan penelusuran, terutama ketika memvalidasi desain jarum suntik baru atau melakukan pemeriksaan kualitas rutin.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c3b5bb elementor-widget elementor-widget-heading\" data-id=\"5c3b5bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mengapa Memilih Instrumen Sel untuk Pengujian Jarum Suntik?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7471474 elementor-widget elementor-widget-text-editor\" data-id=\"7471474\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4659\" data-end=\"5243\">Dengan pengalaman puluhan tahun dalam <strong data-start=\"4744\" data-end=\"4779\">pengujian bahan perangkat medis<\/strong>, <strong data-start=\"4781\" data-end=\"4801\">Instrumen Sel<\/strong> menawarkan solusi pengujian mutakhir yang disesuaikan dengan standar ISO dan ASTM. Kami <strong>Penguji Jarum Suntik<\/strong> secara khusus dirancang untuk mendukung berbagai <strong data-start=\"4971\" data-end=\"4990\">pengujian jarum suntik<\/strong> metode, termasuk <strong data-start=\"5010\" data-end=\"5043\">ketahanan kerusakan kerucut luer<\/strong>. Baik Anda dalam produksi, penelitian, atau verifikasi pihak ketiga, Cell Instruments dapat memberikan solusi yang disesuaikan, integrasi otomasi, dan dukungan komprehensif untuk memenuhi kebutuhan pengujian Anda.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02c15b6 elementor-widget elementor-widget-text-editor\" data-id=\"02c15b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5250\" data-end=\"5668\">Performing <strong data-start=\"5278\" data-end=\"5311\">ketahanan kerusakan kerucut luer<\/strong> tes sesuai dengan <strong data-start=\"5337\" data-end=\"5361\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Lampiran C2<\/strong> sangat penting untuk memastikan integritas mekanis komponen jarum suntik. Dengan menggunakan peralatan yang akurat seperti <strong>Penguji Jarum Suntik<\/strong>dan mengikuti prosedur yang diamanatkan ISO selangkah demi selangkah, Anda dapat memverifikasi kualitas produk dengan percaya diri, menjaga kepatuhan terhadap peraturan, dan melindungi keselamatan pasien.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3344b6 elementor-widget elementor-widget-text-editor\" data-id=\"a3344b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\"><strong data-start=\"5675\" data-end=\"5746\">Mencari solusi pengujian jarum suntik yang sesuai dengan ISO 11040-4?<\/strong><\/p><p class=\"\" data-start=\"5420\" data-end=\"5503\">Kontak <strong data-start=\"5757\" data-end=\"5787\">Cell Instruments Co, Ltd.<\/strong> hari ini untuk mendapatkan panduan ahli dan sistem pengujian yang disesuaikan untuk kebutuhan jaminan kualitas jarum suntik Anda.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2073","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/id\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/2073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/comments?post=2073"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/2073\/revisions"}],"predecessor-version":[{"id":2084,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/2073\/revisions\/2084"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/media?parent=2073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/categories?post=2073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/tags?post=2073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}