{"id":1994,"date":"2025-04-02T06:13:33","date_gmt":"2025-04-02T06:13:33","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=1994"},"modified":"2025-04-02T06:30:46","modified_gmt":"2025-04-02T06:30:46","slug":"syringes-needle-penetration-test-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/id\/syringes-needle-penetration-test-iso-11040-4\/","title":{"rendered":"Uji Penetrasi Jarum Suntik ISO 11040-4 Lampiran F"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"1994\" class=\"elementor elementor-1994\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d8f0949 e-flex e-con-boxed e-con e-parent\" data-id=\"d8f0949\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af89456 elementor-widget elementor-widget-heading\" data-id=\"af89456\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Pengujian Penetrasi Jarum<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75ecf40 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"75ecf40\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20ce2df elementor-widget elementor-widget-heading\" data-id=\"20ce2df\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Lampiran F<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c9ca423 e-flex e-con-boxed e-con e-parent\" data-id=\"c9ca423\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-41f75ef e-con-full e-flex e-con e-child\" data-id=\"41f75ef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5114c7b elementor-widget elementor-widget-text-editor\" data-id=\"5114c7b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>The <strong>uji penetrasi jarum suntik<\/strong> adalah prosedur penting dalam industri perangkat medis, untuk memastikan ketajaman dan keefektifan jarum yang digunakan dalam aplikasi medis. Tes ini mengevaluasi <strong>kekuatan penetrasi jarum<\/strong> yang diperlukan untuk menembus kertas uji, yang mencerminkan kemudahan jarum untuk menembus kulit manusia atau bahan lainnya.<\/p><p>Untuk menjamin keselamatan pasien dan keandalan produk, standar internasional seperti <strong>ISO 11040-4<\/strong> menguraikan metodologi pengujian yang tepat untuk jarum suntik. Standar ini membantu produsen mempertahankan kontrol kualitas dan kepatuhan terhadap peraturan.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c4a1c1 elementor-widget elementor-widget-heading\" data-id=\"1c4a1c1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Peralatan Uji Penetrasi Jarum Diperlukan<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-405b6c1 elementor-widget elementor-widget-text-editor\" data-id=\"405b6c1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 3 []\">Menurut <strong>ISO 11040-4<\/strong>peralatan berikut ini sangat penting untuk melakukan <a href=\"https:\/\/www.pharmacopoeiatest.com\/id\/syringe-needle-penetration-test\/\" target=\"_blank\" rel=\"noopener\"><strong>uji penetrasi jarum<\/strong><\/a>:<\/p><ul><li data-pm-slice=\"1 3 []\"><strong>Mesin uji tarik dan kompresi universal<\/strong> dengan rentang pengukuran hingga 10 N (atau sesuai kebutuhan) dan kecepatan uji antara 20 mm\/menit dan 200 mm\/menit.<\/li><li data-pm-slice=\"1 3 []\"><strong>Tempat jarum<\/strong> untuk mengamankan jarum selama pengujian.<\/li><li data-pm-slice=\"1 3 []\"><strong>Uji foil<\/strong>dengan spesifikasi yang telah disepakati oleh produsen dan klien.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3315f97 elementor-widget elementor-widget-image\" data-id=\"3315f97\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/id\/syringe-needle-penetration-test\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/elementor\/thumbs\/ISO-11040-4-syringes-needle-penetration-test-equipment-r3r52op9pahd5s2kzyk3xzbhif0hy69cozbct55ytk.webp\" title=\"Alat uji penetrasi jarum suntik ISO 11040-4\" alt=\"Alat uji penetrasi jarum suntik ISO 11040-4\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff15e94 elementor-widget elementor-widget-heading\" data-id=\"ff15e94\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prosedur Metode Uji Penetrasi Jarum Suntik<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe76308 elementor-widget elementor-widget-text-editor\" data-id=\"fe76308\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ol><li>Amankan kertas uji dalam tempat yang bebas tegangan.<\/li><li>Pasang jarum secara tegak lurus pada dudukannya, sejajarkan ujungnya ke pusat geometris kertas uji.<\/li><li>Mulailah pengujian dan biarkan jarum menembus kertas timah dengan kecepatan yang terkendali.<\/li><li>Catat kurva gaya-perpindahan untuk menganalisis karakteristik penetrasi.<\/li><li>Ulangi pengujian dengan bagian kertas timah yang baru untuk setiap pengukuran.<\/li><\/ol><p>Laju sampling yang lebih tinggi, seperti 500 Hz, meningkatkan akurasi pengukuran ketika merekam nilai gaya puncak.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ebd0c elementor-widget elementor-widget-heading\" data-id=\"60ebd0c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Parameter Kekuatan Penetrasi Jarum Utama dalam Pengujian<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f1cf32 elementor-widget elementor-widget-text-editor\" data-id=\"0f1cf32\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 1 []\">Gaya yang diberikan selama penetrasi dikategorikan ke dalam beberapa tahap yang berbeda:<\/p><ul data-spread=\"false\"><li><strong>Gaya penusukan (F<sub>0<\/sub>):<\/strong> Gaya yang diperlukan untuk meloloskan ujung jarum melalui kertas timah.<\/li><li><strong>Gaya pemotongan (F<sub>1<\/sub>):<\/strong> Gaya yang digunakan oleh mata potong.<\/li><li><strong>Gaya tumit (F<sub>2<\/sub>):<\/strong> Gaya yang diberikan ketika tumit jarum melewatinya.<\/li><li><strong>Gaya penetrasi seret (F<sub>3<\/sub>):<\/strong> Kekuatan resistensi setelah penetrasi penuh.<\/li><\/ul><p>Dengan mengevaluasi parameter ini, produsen dapat memastikan bahwa jarum memenuhi standar ketajaman dan kegunaan yang dipersyaratkan.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84d059d elementor-widget elementor-widget-heading\" data-id=\"84d059d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kepatuhan terhadap ISO 11040-4 untuk Jaminan Kualitas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a670d9 elementor-widget elementor-widget-text-editor\" data-id=\"7a670d9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 3 []\">ISO 11040-4 menetapkan pedoman komprehensif untuk menguji jarum suntik yang sudah diisi sebelumnya, untuk memastikan:<\/p><ul><li data-pm-slice=\"1 3 []\">Terstandarisasi <strong>kekuatan penetrasi jarum<\/strong> pengukuran.<\/li><li data-pm-slice=\"1 3 []\">Konsistensi pada berbagai jenis jarum dan alat suntik.<\/li><li data-pm-slice=\"1 3 []\">Kepatuhan terhadap persyaratan keselamatan medis global.<\/li><li data-pm-slice=\"1 3 []\">Pengurangan risiko yang terkait dengan penetrasi jarum yang tidak tepat.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e1f022 elementor-widget elementor-widget-heading\" data-id=\"5e1f022\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Alat Uji Penetrasi Jarum NPT-01<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53d8fee elementor-widget elementor-widget-text-editor\" data-id=\"53d8fee\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 3 []\">The <strong>Alat uji penetrasi jarum NPT-01<\/strong> dirancang untuk memenuhi <strong>ISO 11040-4<\/strong> sekaligus menawarkan solusi pengujian yang tepat. Fitur-fiturnya:<\/p><ul><li data-pm-slice=\"1 3 []\"><strong>Kontrol PLC dan layar sentuh HMI 7 inci<\/strong> untuk pengoperasian yang mudah.<\/li><li data-pm-slice=\"1 3 []\"><strong>Motor stepper dan sekrup bola presisi<\/strong> memastikan hasil yang konsisten.<\/li><li data-pm-slice=\"1 3 []\"><strong>Kecepatan uji variabel (1-500mm\/menit)<\/strong> untuk kondisi pengujian yang fleksibel.<\/li><li data-pm-slice=\"1 3 []\"><strong>Beberapa jig penahan sampel<\/strong> untuk mengakomodasi berbagai jenis jarum dan alat suntik.<\/li><li data-pm-slice=\"1 3 []\"><strong>Mikroprinter tertanam dan output RS232<\/strong> untuk perekaman data yang efisien.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7e5035 elementor-widget elementor-widget-text-editor\" data-id=\"f7e5035\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-pm-slice=\"1 1 []\">The <strong>uji penetrasi jarum suntik<\/strong> sangat penting untuk memastikan ketajaman jarum, keselamatan pasien, dan kepatuhan terhadap peraturan. Dengan mengikuti <strong>ISO 11040-4<\/strong> pedoman dan menggunakan peralatan pengujian canggih seperti <strong>NPT-01<\/strong>produsen dapat meningkatkan kualitas produk sekaligus memenuhi standar industri.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Uji Penetrasi Jarum ISO 11040-4 Lampiran F Uji penetrasi jarum pada jarum suntik merupakan prosedur penting dalam industri alat kesehatan, yang memastikan ketajaman dan keefektifan jarum yang digunakan dalam aplikasi medis. Uji ini mengevaluasi gaya penetrasi jarum yang diperlukan untuk menembus lembaran uji, yang mencerminkan kemudahan jarum tersebut menembus tubuh manusia [\u2026]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-1994","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/id\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Needle Penetration Testing ISO 11040-4 Annex F The syringes needle penetration test is a crucial procedure in the medical device industry, ensuring the sharpness and effectiveness of needles used in medical applications. This test evaluates the needle penetration force required to pierce a test foil, reflecting the ease with which a needle can penetrate human&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/1994","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/comments?post=1994"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/1994\/revisions"}],"predecessor-version":[{"id":2009,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/posts\/1994\/revisions\/2009"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/media?parent=1994"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/categories?post=1994"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/id\/wp-json\/wp\/v2\/tags?post=1994"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}