{"id":2197,"date":"2025-06-24T02:14:04","date_gmt":"2025-06-24T02:14:04","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2197"},"modified":"2025-06-24T02:18:12","modified_gmt":"2025-06-24T02:18:12","slug":"iso-7864","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/hu\/iso-7864\/","title":{"rendered":"ISO 7864 injekci\u00f3s fecskend\u0151 funkcionalit\u00e1s\u00e1nak vizsg\u00e1lata"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2197\" class=\"elementor elementor-2197\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-66b560c e-flex e-con-boxed e-con e-parent\" data-id=\"66b560c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-86c40f3 elementor-widget elementor-widget-heading\" data-id=\"86c40f3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 7864 <br><small><small>Hypodermic Syringe Functionality Testing<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b5014aa e-con-full e-flex e-con e-child\" data-id=\"b5014aa\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dea855d elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"dea855d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"398\" data-end=\"1099\">When it comes to sterile hypodermic needles, patient safety and product performance are non-negotiable. That\u2019s where <strong data-start=\"534\" data-end=\"546\">ISO 7864<\/strong> plays a vital role. This international standard outlines comprehensive requirements and test methods to evaluate hypodermic needles for <strong data-start=\"683\" data-end=\"706\">single-use syringes<\/strong>, bele\u00e9rtve <strong data-start=\"718\" data-end=\"751\">fecskend\u0151 funkcionalit\u00e1s\u00e1nak vizsg\u00e1lata<\/strong>, <strong data-start=\"753\" data-end=\"787\">t\u0171 behatol\u00e1svizsg\u00e1lati m\u00f3dszer<\/strong>, \u00e9s <strong data-start=\"793\" data-end=\"820\">strength of needle bond<\/strong>. Manufacturers, quality control engineers, and regulatory bodies rely on ISO 7864 to ensure consistent product quality and safety.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f53d82 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"7f53d82\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/hu\/syringe-needle-penetration-test\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1.webp\" class=\"attachment-full size-full wp-image-2200\" alt=\"ISO 7864 injekci\u00f3s fecskend\u0151 funkcionalit\u00e1s\u00e1nak vizsg\u00e1lata\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1-300x200.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11bf196 elementor-widget elementor-widget-heading\" data-id=\"11bf196\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What Is ISO 7864 and Why It Matters<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edf0ed0 elementor-widget elementor-widget-text-editor\" data-id=\"edf0ed0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1422\"><strong data-start=\"1148\" data-end=\"1160\">ISO 7864<\/strong> is the <strong data-start=\"1168\" data-end=\"1225\">International Standard for sterile hypodermic needles<\/strong> intended for single-use with syringes or infusion equipment. It defines the needle&#8217;s physical requirements, dimensions, performance characteristics, packaging, and <strong data-start=\"1390\" data-end=\"1406\">test methods<\/strong> for evaluating:<\/p><ul><li data-start=\"1426\" data-end=\"1445\"><strong data-start=\"1426\" data-end=\"1443\">Penetrability<\/strong><\/li><li data-start=\"1448\" data-end=\"1470\"><strong data-start=\"1448\" data-end=\"1468\">Bonding strength<\/strong><\/li><li data-start=\"1473\" data-end=\"1500\"><strong data-start=\"1473\" data-end=\"1498\">Needle tube integrity<\/strong><\/li><li data-start=\"1503\" data-end=\"1529\"><strong data-start=\"1503\" data-end=\"1527\">Corrosion resistance<\/strong><\/li><li data-start=\"1532\" data-end=\"1557\"><strong data-start=\"1532\" data-end=\"1557\">Syringe compatibility<\/strong><\/li><\/ul><p data-start=\"1559\" data-end=\"1707\">Compliance with ISO 7864 ensures that needles perform reliably under clinical conditions, reducing risks for both patients and healthcare providers.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f659161 elementor-widget elementor-widget-heading\" data-id=\"f659161\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO Syringe Functionality Testing<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1eb6db elementor-widget elementor-widget-text-editor\" data-id=\"c1eb6db\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1714\" data-end=\"1946\"><strong data-start=\"1782\" data-end=\"1815\">Syringe functionality testing<\/strong> ensures the needle is compatible with its designated syringe and performs effectively during injection. Parameters tested include:<\/p><ul><li data-start=\"1950\" data-end=\"1990\"><strong data-start=\"1950\" data-end=\"1988\">Compatibility with Luer connectors<\/strong><\/li><li data-start=\"1993\" data-end=\"2012\"><strong data-start=\"1993\" data-end=\"2010\">Plunger force<\/strong><\/li><li data-start=\"2015\" data-end=\"2048\"><strong data-start=\"2015\" data-end=\"2046\">Injection force consistency<\/strong><\/li><li data-start=\"2051\" data-end=\"2078\"><strong data-start=\"2051\" data-end=\"2078\">Dead space minimization<\/strong><\/li><\/ul><p data-start=\"2080\" data-end=\"2309\">These evaluations are critical for an <strong data-start=\"2118\" data-end=\"2133\">ISO syringe<\/strong> to pass certification. Cell Instruments provides solutions that assess functionality by measuring insertion force, plunger resistance, and force distribution during injection.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64b918a elementor-widget elementor-widget-heading\" data-id=\"64b918a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Needle Penetrability Test<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7baacfb elementor-widget elementor-widget-text-editor\" data-id=\"7baacfb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2316\" data-end=\"2506\">One of the most important test under ISO 7864 is the <strong data-start=\"2429\" data-end=\"2463\">t\u0171 behatol\u00e1svizsg\u00e1lati m\u00f3dszer<\/strong>, also known as the <strong data-start=\"2483\" data-end=\"2505\">penetrability test<\/strong>.<\/p><p data-start=\"2508\" data-end=\"2747\"><strong data-start=\"2508\" data-end=\"2526\">Vizsg\u00e1lati elv<\/strong><br data-start=\"2526\" data-end=\"2529\" \/>A needle is inserted into a standardized <strong data-start=\"2570\" data-end=\"2583\">szubsztr\u00e1tum<\/strong> at a constant speed (typically 100 mm\/min). The <strong data-start=\"2632\" data-end=\"2658\">maxim\u00e1lis behatol\u00e1si er\u0151<\/strong> \u00e9s <strong data-start=\"2663\" data-end=\"2677\">h\u00faz\u00f3er\u0151<\/strong> are recorded to evaluate ease of penetration and consistent movement.<\/p><p data-start=\"2749\" data-end=\"2768\"><strong data-start=\"2749\" data-end=\"2766\">Key Equipment<\/strong><\/p><ul><li data-start=\"2771\" data-end=\"2826\">Force measurement system with precision <strong data-start=\"2811\" data-end=\"2824\">terhel\u00e9sm\u00e9r\u0151 cella<\/strong><\/li><li data-start=\"2829\" data-end=\"2865\">Needle holder with axial alignment<\/li><li data-start=\"2868\" data-end=\"2918\">Validated substrate (e.g., latex rubber or LDPE)<\/li><li data-start=\"2921\" data-end=\"2979\">Penetration depth gauge (typically 80% of needle length)<\/li><\/ul><p data-start=\"2981\" data-end=\"3175\"><strong data-start=\"2981\" data-end=\"3001\">Cell Instruments<\/strong> offers <strong data-start=\"3009\" data-end=\"3049\">automated needle penetration tester<\/strong>\u00a0with programmable speeds and digital force analysis to ensure accuracy and repeatability in compliance with ISO 7864 Annex D.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46d372b elementor-widget elementor-widget-heading\" data-id=\"46d372b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Drag Force and Peak Penetration Force<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b565e71 elementor-widget elementor-widget-text-editor\" data-id=\"b565e71\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3182\" data-end=\"3269\">Two main results are derived:<\/p><ul><li data-start=\"3273\" data-end=\"3345\"><strong data-start=\"3273\" data-end=\"3300\">Peak Penetration Force:<\/strong> Max force required to pierce the substrate<\/li><li data-start=\"3348\" data-end=\"3436\"><strong data-start=\"3348\" data-end=\"3363\">Drag Force:<\/strong> Average force needed to maintain penetration over 80% of needle length<\/li><\/ul><p data-start=\"3438\" data-end=\"3600\">These metrics reflect needle sharpness, friction, and manufacturing consistency. For regulatory submissions and design validation, precise measurement is crucial.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c892b5 elementor-widget elementor-widget-heading\" data-id=\"5c892b5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Strength of Needle Bond Test<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30d6b5b elementor-widget elementor-widget-text-editor\" data-id=\"30d6b5b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3607\" data-end=\"3825\">Bond strength refers to the <strong data-start=\"3697\" data-end=\"3745\">adhesion between the needle tube and the hub<\/strong>\u2014a weak bond could lead to detachment during injection, posing a serious hazard.<\/p><p data-start=\"3827\" data-end=\"3870\"><strong data-start=\"3827\" data-end=\"3868\">Testing Procedure (ISO 7864 Annex E):<\/strong><\/p><ul><li data-start=\"3873\" data-end=\"3938\">Needle is gripped vertically on a <strong data-start=\"3907\" data-end=\"3936\">universal testing machine<\/strong><\/li><li data-start=\"3941\" data-end=\"3986\">A <strong data-start=\"3943\" data-end=\"3960\">szak\u00edt\u00f3er\u0151<\/strong> is applied at 50 mm\/min<\/li><li data-start=\"3989\" data-end=\"4062\">A <strong data-start=\"3993\" data-end=\"4010\">maximum force<\/strong> at which detachment or failure occurs is recorded<\/li><\/ul><p data-start=\"4064\" data-end=\"4223\"><strong data-start=\"4064\" data-end=\"4084\">Cell Instruments<\/strong> provides <strong data-start=\"4094\" data-end=\"4123\">universal tensile tester<\/strong>\u00a0with customized fixtures for <strong data-start=\"4153\" data-end=\"4177\">needle bonding test<\/strong>, ensuring compliance with Annex E procedures.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94ab6f1 elementor-widget elementor-widget-heading\" data-id=\"94ab6f1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Cell Instruments Compliance with ISO 7864 <\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-603c5c9 elementor-widget elementor-widget-text-editor\" data-id=\"603c5c9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4230\" data-end=\"4393\">Cell Instruments specializes in <strong data-start=\"4318\" data-end=\"4349\">precision testing solutions<\/strong> for medical device manufacturers, offering:<\/p><ul><li data-start=\"4397\" data-end=\"4427\">Needle Penetrability Tester<\/li><li data-start=\"4430\" data-end=\"4463\">Universal Bond Strength Tester<\/li><li data-start=\"4466\" data-end=\"4505\">Syringe Functionality Testing Systems<\/li><li data-start=\"4508\" data-end=\"4576\">Customized fixtures for Luer lock compatibility and needle holding<\/li><li data-start=\"4579\" data-end=\"4637\">Automation upgrades for <strong data-start=\"4603\" data-end=\"4635\">repeatability and throughput<\/strong><\/li><\/ul><p data-start=\"4639\" data-end=\"4842\">All instruments are built to align with <strong data-start=\"4679\" data-end=\"4691\">ISO 7864<\/strong>, <strong data-start=\"4693\" data-end=\"4705\">ISO 8537<\/strong>, <a href=\"https:\/\/www.pharmacopoeiatest.com\/hu\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"4707\" data-end=\"4719\">ISO 7886<\/strong><\/a>, \u00e9s <strong data-start=\"4725\" data-end=\"4736\">USP 381<\/strong> standards. Our systems support statistical analysis, data export, and traceable calibration certificates.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0546b7e elementor-widget elementor-widget-heading\" data-id=\"0546b7e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">GYIK<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3b149b elementor-widget elementor-widget-toggle\" data-id=\"f3b149b\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2551\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2551\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">1. What is ISO 7864?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2551\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2551\"><p data-start=\"5830\" data-end=\"6017\"><a href=\"https:\/\/www.iso.org\/standard\/60481.html\" target=\"_blank\" rel=\"noopener\">ISO 7864<\/a> specifies requirements and test methods for sterile hypodermic needles for single use. It covers physical dimensions, materials, and performance test.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2552\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2552\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">2. What does syringe functionality testing involve?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2552\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2552\"><p data-start=\"6019\" data-end=\"6226\">It evaluates the interaction between syringe and needle, including injection force, sealing, and ease of use to ensure consistent and safe operation.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2553\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2553\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">3. How is the penetrability test performed?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2553\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2553\"><p data-start=\"6228\" data-end=\"6415\">A needle is inserted into a standardized material at 100 mm\/min. Peak and drag forces are recorded to evaluate sharpness and performance.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2554\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2554\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">4. What is measured in the needle bond strength test?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2554\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2554\"><p data-start=\"6417\" data-end=\"6591\">The tensile force needed to detach the needle from the hub. It verifies mechanical integrity under applied stress.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2555\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2555\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">5. Which instruments can help with ISO 7864 compliance?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2555\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2555\"><p data-start=\"6593\" data-end=\"6806\">Cell Instruments\u2019 automated\u00a0<strong data-start=\"6683\" data-end=\"6708\">penetrability tester<\/strong>\u00a0\u00e9s\u00a0<strong data-start=\"6713\" data-end=\"6742\">universal tensile tester<\/strong>\u00a0are ideal for ISO 7864-compliant needle and syringe evaluation.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7864 injekci\u00f3s fecskend\u0151 funkcionalit\u00e1s\u00e1nak vizsg\u00e1lata Amikor steril injekci\u00f3s t\u0171kr\u0151l van sz\u00f3, a betegbiztons\u00e1g \u00e9s a term\u00e9k teljes\u00edtm\u00e9nye nem k\u00e9pezi vita t\u00e1rgy\u00e1t. Ebben az ISO 7864 szabv\u00e1ny l\u00e9tfontoss\u00e1g\u00fa szerepet j\u00e1tszik. Ez a nemzetk\u00f6zi szabv\u00e1ny \u00e1tfog\u00f3 k\u00f6vetelm\u00e9nyeket \u00e9s vizsg\u00e1lati m\u00f3dszereket hat\u00e1roz meg az egyszer haszn\u00e1latos fecskend\u0151kh\u00f6z haszn\u00e1lt injekci\u00f3s t\u0171k \u00e9rt\u00e9kel\u00e9s\u00e9re, bele\u00e9rtve a fecskend\u0151 funkcionalit\u00e1s\u00e1nak vizsg\u00e1lat\u00e1t, a t\u0171 behatol\u00e1svizsg\u00e1lati m\u00f3dszert \u00e9s a [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[93,92],"class_list":["post-2197","post","type-post","status-publish","format-standard","hentry","category-blog","tag-iso-7864","tag-standards"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/hu\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 7864 Hypodermic Syringe Functionality Testing When it comes to sterile hypodermic needles, patient safety and product performance are non-negotiable. That\u2019s where ISO 7864 plays a vital role. This international standard outlines comprehensive requirements and test methods to evaluate hypodermic needles for single-use syringes, including syringe functionality testing, needle penetration test method, and strength of&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/posts\/2197","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/comments?post=2197"}],"version-history":[{"count":4,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/posts\/2197\/revisions"}],"predecessor-version":[{"id":2203,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/posts\/2197\/revisions\/2203"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/media?parent=2197"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/categories?post=2197"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/tags?post=2197"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}