{"id":2073,"date":"2025-04-22T03:59:40","date_gmt":"2025-04-22T03:59:40","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2073"},"modified":"2025-04-22T06:49:25","modified_gmt":"2025-04-22T06:49:25","slug":"luer-cone-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/hu\/luer-cone-breakage-resistance-iso-11040-4\/","title":{"rendered":"Luer-k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1ga - ISO 11040-4 C2 mell\u00e9klet"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2073\" class=\"elementor elementor-2073\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef785b6 e-flex e-con-boxed e-con e-parent\" data-id=\"ef785b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d4a251 elementor-widget elementor-widget-heading\" data-id=\"6d4a251\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer Cone t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1g<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b910e1 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8b910e1\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec4bbc1 elementor-widget elementor-widget-heading\" data-id=\"ec4bbc1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 C2 mell\u00e9klet<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bdc54b0 e-flex e-con-boxed e-con e-parent\" data-id=\"bdc54b0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a300c79 elementor-widget elementor-widget-text-editor\" data-id=\"a300c79\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"400\" data-end=\"1016\">A fecskend\u0151gy\u00e1rt\u00e1s \u00e9s a min\u0151s\u00e9gellen\u0151rz\u00e9s sor\u00e1n az egyik legkritikusabb mechanikai \u00e9rt\u00e9kel\u00e9s a <strong data-start=\"520\" data-end=\"553\">luer k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1g<\/strong> teszt. A fecskend\u0151 el\u00fcls\u0151 r\u00e9sz\u00e9nek szerkezeti integrit\u00e1sa, k\u00fcl\u00f6n\u00f6sen a luer-k\u00fap, k\u00f6zvetlen\u00fcl befoly\u00e1solja mind a betegbiztons\u00e1got, mind az eszk\u00f6z megb\u00edzhat\u00f3s\u00e1g\u00e1t. A k\u00f6vetkezetes, szabv\u00e1nyos\u00edtott \u00e9rt\u00e9kel\u00e9s biztos\u00edt\u00e1sa \u00e9rdek\u00e9ben a <em data-start=\"749\" data-end=\"762\">ISO 11040-4<\/em> szabv\u00e1ny - konkr\u00e9tan <em data-start=\"785\" data-end=\"795\">C2. mell\u00e9klet<\/em>-meghat\u00e1rozza a vizsg\u00e1lat elv\u00e9gz\u00e9s\u00e9nek elj\u00e1r\u00e1sait \u00e9s k\u00f6vetelm\u00e9nyeit. Ez a cikk v\u00e9gigvezeti \u00d6nt a vizsg\u00e1lati folyamaton, az alapvet\u0151 berendez\u00e9seken \u00e9s az adatok \u00e9rtelmez\u00e9s\u00e9n, amelyek sz\u00fcks\u00e9gesek a k\u00f6vetkez\u0151knek val\u00f3 megfelel\u00e9shez <a href=\"https:\/\/www.pharmacopoeiatest.com\/hu\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> vizsg\u00e1lati szabv\u00e1nyok.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3c5bd5 elementor-widget elementor-widget-heading\" data-id=\"b3c5bd5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">A Luer-k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1g\u00e1nak fontoss\u00e1ga<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ddf4e elementor-widget elementor-widget-text-editor\" data-id=\"60ddf4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>A fecskend\u0151h\u00fcvely el\u00fcls\u0151 v\u00e9g\u00e9n tal\u00e1lhat\u00f3 luer-k\u00fap egy potenci\u00e1lis gyenge pont, amely a kezel\u00e9s, \u00f6sszeszerel\u00e9s vagy befecskendez\u00e9s sor\u00e1n mechanikai ig\u00e9nybev\u00e9telnek van kit\u00e9ve. <strong data-start=\"1248\" data-end=\"1281\">Luer k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1ga<\/strong> A vizsg\u00e1lat seg\u00edt meghat\u00e1rozni, hogy mekkora er\u0151t b\u00edr ki a k\u00fap a t\u00f6r\u00e9s el\u0151tt. A gy\u00e1rt\u00f3k sz\u00e1m\u00e1ra a <em data-start=\"1384\" data-end=\"1405\">el\u0151ret\u00f6lt\u00f6tt fecskend\u0151k<\/em> \u00e9s <em data-start=\"1410\" data-end=\"1441\">\u00fcveghord\u00f3k injekci\u00f3s k\u00e9sz\u00edtm\u00e9nyekhez<\/em>, ez a vizsg\u00e1lat nem csup\u00e1n szab\u00e1lyoz\u00e1si k\u00f6vetelm\u00e9ny - ez egy alapvet\u0151 min\u0151s\u00e9gellen\u0151rz\u00e9si int\u00e9zked\u00e9s a hib\u00e1k elker\u00fcl\u00e9se \u00e9rdek\u00e9ben az orvosi alkalmaz\u00e1sokban.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d476dd elementor-widget elementor-widget-heading\" data-id=\"3d476dd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 C2 mell\u00e9klet C2 Luer-k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1gi vizsg\u00e1lati m\u00f3dszer<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642e2e7 elementor-widget elementor-widget-text-editor\" data-id=\"642e2e7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1582\" data-end=\"2040\">A <strong data-start=\"1636\" data-end=\"1651\">ISO 11040-4<\/strong> szabv\u00e1ny, amelynek c\u00edme <em data-start=\"1669\" data-end=\"1784\">El\u0151re t\u00f6lt\u00f6tt fecskend\u0151k - 4. r\u00e9sz: \u00dcveghord\u00f3k injekci\u00f3s k\u00e9sz\u00edtm\u00e9nyekhez \u00e9s steriliz\u00e1lt, t\u00f6lt\u00e9sre k\u00e9sz, alul-\u00f6sszeszerelt fecskend\u0151k<\/em>, mag\u00e1ban foglalja <strong data-start=\"1795\" data-end=\"1807\">C2. mell\u00e9klet<\/strong>, amely r\u00e9szletesen ismerteti a <em data-start=\"1827\" data-end=\"1858\">az el\u00fcls\u0151 v\u00e9g t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1ga<\/em> teszt. Ez a szakasz ismerteti azokat a felt\u00e9teleket, amelyek mellett a vizsg\u00e1latot el kell v\u00e9gezni, bele\u00e9rtve a k\u00e9sz\u00fcl\u00e9kre vonatkoz\u00f3 k\u00f6vetelm\u00e9nyeket, a mint\u00e1k kezel\u00e9s\u00e9t, a vizsg\u00e1lati elj\u00e1r\u00e1sokat \u00e9s az eredm\u00e9nyek dokument\u00e1l\u00e1s\u00e1t.<\/p><h3 class=\"\" data-start=\"2042\" data-end=\"2077\">A legfontosabb vizsg\u00e1lati felt\u00e9telek k\u00f6z\u00e9 tartoznak:<\/h3><ul><li data-start=\"2080\" data-end=\"2105\">Tesztel\u00e9si sebess\u00e9g: <strong data-start=\"2092\" data-end=\"2105\">25 mm\/min<\/strong><\/li><li data-start=\"2080\" data-end=\"2105\">Alkalmaz\u00e1si pont: <strong style=\"font-size: 16px;\" data-start=\"2127\" data-end=\"2135\">2 mm<\/strong><span style=\"font-size: 16px;\"> a fecskend\u0151 hegy\u00e9b\u0151l<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Minim\u00e1lis mintav\u00e9teli sebess\u00e9g: <strong style=\"font-size: 16px;\" data-start=\"2182\" data-end=\"2192\">500 Hz<\/strong><span style=\"font-size: 16px;\"> a cs\u00facsm\u00e9r\u00e9si pontoss\u00e1ghoz<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Alkalmazott er\u0151, am\u00edg <strong style=\"font-size: 16px;\" data-start=\"2245\" data-end=\"2263\">\u00fcvegt\u00f6r\u00e9s<\/strong><span style=\"font-size: 16px;\"> t\u00f6rt\u00e9nik<\/span><\/li><\/ul><p class=\"\" data-start=\"2272\" data-end=\"2390\">Az \u00fatmutat\u00e1s k\u00f6vet\u00e9se biztos\u00edtja, hogy az \u00d6n <strong data-start=\"2314\" data-end=\"2333\">fecskend\u0151s vizsg\u00e1lat<\/strong> a folyamatok nyomon k\u00f6vethet\u0151ek, reproduk\u00e1lhat\u00f3ak \u00e9s megfelel\u0151ek maradnak.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4dbc7e2 elementor-widget elementor-widget-heading\" data-id=\"4dbc7e2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fecskend\u0151-vizsg\u00e1l\u00f3 az ISO 11040-4 mell\u00e9klet C2 tesztel\u00e9s\u00e9hez<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7da5e4d elementor-widget elementor-widget-text-editor\" data-id=\"7da5e4d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2454\" data-end=\"2671\">A pontos elv\u00e9gz\u00e9shez <strong data-start=\"2476\" data-end=\"2509\">luer k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1g<\/strong> tesztek elv\u00e9gz\u00e9s\u00e9hez egy megb\u00edzhat\u00f3 \u00e9s pontos <strong data-start=\"2552\" data-end=\"2605\">univerz\u00e1lis szak\u00edt\u00f3- \u00e9s nyom\u00f3vizsg\u00e1lati g\u00e9p<\/strong>. A k\u00e9sz\u00fcl\u00e9knek meg kell felelnie az ISO 11040-4 mell\u00e9klet C2 k\u00f6vetelm\u00e9nyeinek:<\/p><ul><li data-start=\"2675\" data-end=\"2729\">A <strong data-start=\"2677\" data-end=\"2690\">terhel\u00e9sm\u00e9r\u0151 cella<\/strong> t\u00f6r\u0151er\u0151k m\u00e9r\u00e9s\u00e9re alkalmas<\/li><li data-start=\"2675\" data-end=\"2729\">Pontos, programozhat\u00f3 <strong style=\"font-size: 16px;\" data-start=\"2758\" data-end=\"2780\">teszt sebess\u00e9gszab\u00e1lyoz\u00e1s<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Egyedi <strong style=\"font-size: 16px;\" data-start=\"2792\" data-end=\"2834\">rozsdamentes ac\u00e9l tart\u00f3 \u00e9s rakod\u00f3r\u00fad<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">A fecskend\u0151 kialak\u00edt\u00e1s\u00e1nak geometri\u00e1j\u00e1hoz illeszked\u0151 adapterk\u00e9szletek<\/li><\/ul><h3 class=\"\" data-start=\"2889\" data-end=\"2967\">Aj\u00e1nlott fecskend\u0151 teszter<\/h3><p class=\"\" data-start=\"2969\" data-end=\"3383\">Cell Instruments' <em>Fecskend\u0151 tesztel\u0151<\/em>\u00a0\u00fagy tervezt\u00e9k, hogy megfeleljen az ISO fecskend\u0151vizsg\u00e1lat szigor\u00fa k\u00f6vetelm\u00e9nyeinek. A programozhat\u00f3 PLC-vez\u00e9rl\u00e9ssel, prec\u00edzi\u00f3s mechanik\u00e1val \u00e9s testreszabhat\u00f3 r\u00f6gz\u00edt\u0151kkel felszerelt MPT-01 nagy felbont\u00e1s\u00fa er\u0151- \u00e9s elmozdul\u00e1si adatokat szolg\u00e1ltat, \u00edgy ide\u00e1lis a k\u00f6vetkez\u0151kh\u00f6z <strong data-start=\"3241\" data-end=\"3274\">luer k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1g<\/strong> \u00e9rt\u00e9kel\u00e9sek. A be\u00e9p\u00edtett mikronyomtat\u00f3 \u00e9s az opcion\u00e1lis RS232 adatexport szint\u00e9n t\u00e1mogatja a r\u00e9szletes dokument\u00e1ci\u00f3t.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4ff2b elementor-widget elementor-widget-heading\" data-id=\"6b4ff2b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer-k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1gi tesztel\u00e9si elj\u00e1r\u00e1s<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c990a3c e-con-full e-flex e-con e-child\" data-id=\"c990a3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-dbcf8eb e-con-full e-flex e-con e-child\" data-id=\"dbcf8eb\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53324d6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"53324d6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 fecskend\u0151 sziv\u00e1rg\u00e1svizsg\u00e1lat\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9962325 e-con-full e-flex e-con e-child\" data-id=\"9962325\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea7609b elementor-widget elementor-widget-text-editor\" data-id=\"ea7609b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3460\" data-end=\"3483\"><strong>1. A teszt el\u0151k\u00e9sz\u00edt\u00e9se<\/strong><\/p><ul><li data-start=\"3486\" data-end=\"3553\">Ellen\u0151rizze az \u00f6sszes adaptert \u00e9s anyagot <strong data-start=\"3525\" data-end=\"3552\">s\u00e9r\u00fcl\u00e9s vagy kompatibilit\u00e1s<\/strong>.<\/li><li data-start=\"3486\" data-end=\"3553\">Szerelje fel a sz\u00fcks\u00e9ges adaptert \u00e9s szerelv\u00e9nyeket a <strong style=\"font-size: 16px;\">Fecskend\u0151 tesztel\u0151<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3486\" data-end=\"3553\">Biztos\u00edtani kell a megfelel\u0151 igaz\u00edt\u00e1st \u00e9s <strong style=\"font-size: 16px;\" data-start=\"3652\" data-end=\"3677\">biztons\u00e1gi v\u00e9d\u0151burkolatok felszerel\u00e9se<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul><p data-start=\"3680\" data-end=\"3704\"><strong>2. A tesztel\u00e9s v\u00e9grehajt\u00e1sa<\/strong><\/p><ul><li data-start=\"3707\" data-end=\"3749\">Helyezze a fecskend\u0151h\u00fcvelyt a tart\u00f3ba.<\/li><li data-start=\"3707\" data-end=\"3749\">A rakod\u00f3t\u00fcske elhelyez\u00e9se <strong style=\"font-size: 16px;\" data-start=\"3777\" data-end=\"3806\">2 mm-re a fecskend\u0151 hegy\u00e9t\u0151l<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">\u00c1ll\u00edtsa be a sebess\u00e9get <strong style=\"font-size: 16px;\" data-start=\"3827\" data-end=\"3840\">25 mm\/min<\/strong><span style=\"font-size: 16px;\"> \u00e9s ind\u00edtsa el a tesztet.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Nyomja \u00f6ssze, am\u00edg a luer k\u00fap <strong style=\"font-size: 16px;\" data-start=\"3901\" data-end=\"3914\">t\u00f6r\u00e9sek<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Vegye fel a <strong style=\"font-size: 16px;\" data-start=\"3929\" data-end=\"3958\">maxim\u00e1lis t\u00f6r\u00e9si er\u0151<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4898eec elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"4898eec\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"272\" height=\"270\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png\" class=\"attachment-large size-large wp-image-2078\" alt=\"Luer-k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1ga - ISO 11040-4 mell\u00e9klet C2 fecskend\u0151vizsg\u00e1lat\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png 272w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing-150x150.png 150w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322584f elementor-widget elementor-widget-text-editor\" data-id=\"322584f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3961\" data-end=\"3999\"><b>3. Teszt ut\u00e1ni tiszt\u00edt\u00e1s \u00e9s elemz\u00e9s<\/b><\/p><ul><li data-start=\"4002\" data-end=\"4038\">\u00d3vatosan t\u00e1vol\u00edtsa el a t\u00f6r\u00f6tt fecskend\u0151t.<\/li><li data-start=\"4002\" data-end=\"4038\">Tiszt\u00edtsa meg az adaptert, hogy elt\u00e1vol\u00edtsa az \u00fcvegt\u00f6rmel\u00e9ket.<\/li><li data-start=\"4002\" data-end=\"4038\">Elemezze az eredm\u00e9nyeket \u00e9s er\u0151s\u00edtse meg <strong style=\"font-size: 16px;\" data-start=\"4117\" data-end=\"4138\">t\u00f6r\u00e9s helye<\/strong><span style=\"font-size: 16px;\"> az el\u00fcls\u0151 v\u00e9g\u00e9n.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04ee823 elementor-widget elementor-widget-heading\" data-id=\"04ee823\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Az ISO 11040-4 szerinti eredm\u00e9nyjelent\u00e9si k\u00f6vetelm\u00e9nyek<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a8c95c elementor-widget elementor-widget-text-editor\" data-id=\"9a8c95c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4216\" data-end=\"4286\">Minden vizsg\u00e1latot alaposan dokument\u00e1lni kell, bele\u00e9rtve a k\u00f6vetkez\u0151 adatokat:<\/p><ul><li data-start=\"4289\" data-end=\"4313\"><strong data-start=\"4289\" data-end=\"4303\">Tesztel\u00e9si sebess\u00e9g<\/strong> mm\/min-ben<\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4316\" data-end=\"4349\">T\u00e1vols\u00e1g a fecskend\u0151 hegy\u00e9t\u0151l<\/strong><span style=\"font-size: 16px;\"> ahol az er\u0151t kifejtett\u00e9k<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4383\" data-end=\"4409\">Maxim\u00e1lis t\u00f6r\u0151er\u0151<\/strong><span style=\"font-size: 16px;\"> newtonban (N)<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4427\" data-end=\"4446\">Minta mennyis\u00e9ge<\/strong><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4449\" data-end=\"4480\">B\u00e1rmilyen rendelleness\u00e9g vagy elt\u00e9r\u00e9s<\/strong><span style=\"font-size: 16px;\"> az elj\u00e1r\u00e1sb\u00f3l<\/span><\/li><\/ul><p class=\"\" data-start=\"4501\" data-end=\"4652\">Ez a r\u00e9szletess\u00e9g biztos\u00edtja a k\u00f6vetkezetess\u00e9get \u00e9s lehet\u0151v\u00e9 teszi a nyomon k\u00f6vethet\u0151s\u00e9get, k\u00fcl\u00f6n\u00f6sen az \u00faj fecskend\u0151tervek valid\u00e1l\u00e1sakor vagy a rutinszer\u0171 min\u0151s\u00e9gellen\u0151rz\u00e9sek sor\u00e1n.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c3b5bb elementor-widget elementor-widget-heading\" data-id=\"5c3b5bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mi\u00e9rt v\u00e1lassza a Cell Instruments-t a fecskend\u0151vizsg\u00e1lathoz?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7471474 elementor-widget elementor-widget-text-editor\" data-id=\"7471474\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4659\" data-end=\"5243\">T\u00f6bb \u00e9vtizedes tapasztalattal rendelkezik a <strong data-start=\"4744\" data-end=\"4779\">orvosi eszk\u00f6z\u00f6k anyagvizsg\u00e1lata<\/strong>, <strong data-start=\"4781\" data-end=\"4801\">Cell Instruments<\/strong> az ISO- \u00e9s ASTM-szabv\u00e1nyokhoz igazod\u00f3, korszer\u0171 vizsg\u00e1lati megold\u00e1sokat k\u00edn\u00e1l. A <strong>Fecskend\u0151 tesztel\u0151<\/strong> kifejezetten \u00fagy tervezt\u00e9k, hogy t\u00e1mogassa a k\u00fcl\u00f6nb\u00f6z\u0151 <strong data-start=\"4971\" data-end=\"4990\">fecskend\u0151s vizsg\u00e1lat<\/strong> m\u00f3dszerek, bele\u00e9rtve a k\u00f6vetkez\u0151ket <strong data-start=\"5010\" data-end=\"5043\">luer k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1g<\/strong>. Legyen sz\u00f3 gy\u00e1rt\u00e1sr\u00f3l, kutat\u00e1sr\u00f3l vagy harmadik f\u00e9l \u00e1ltali ellen\u0151rz\u00e9sr\u0151l, a Cell Instruments szem\u00e9lyre szabott megold\u00e1sokat, automatiz\u00e1l\u00e1si integr\u00e1ci\u00f3t \u00e9s \u00e1tfog\u00f3 t\u00e1mogat\u00e1st tud ny\u00fajtani az \u00d6n tesztel\u00e9si ig\u00e9nyeinek kiel\u00e9g\u00edt\u00e9s\u00e9re.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02c15b6 elementor-widget elementor-widget-text-editor\" data-id=\"02c15b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5250\" data-end=\"5668\">El\u0151ad\u00e1s <strong data-start=\"5278\" data-end=\"5311\">luer k\u00fap t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1g<\/strong> vizsg\u00e1latok a k\u00f6vetkez\u0151kkel \u00f6sszhangban <strong data-start=\"5337\" data-end=\"5361\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> C2. mell\u00e9klet<\/strong> alapvet\u0151 fontoss\u00e1g\u00fa a fecskend\u0151 alkatr\u00e9szeinek mechanikai \u00e9ps\u00e9g\u00e9nek biztos\u00edt\u00e1s\u00e1hoz. Az olyan pontos berendez\u00e9sek haszn\u00e1lat\u00e1val, mint a <strong>Fecskend\u0151 tesztel\u0151<\/strong>, \u00e9s az ISO \u00e1ltal el\u0151\u00edrt elj\u00e1r\u00e1s l\u00e9p\u00e9sr\u0151l-l\u00e9p\u00e9sre t\u00f6rt\u00e9n\u0151 k\u00f6vet\u00e9s\u00e9vel magabiztosan ellen\u0151rizheti a term\u00e9k min\u0151s\u00e9g\u00e9t, fenntarthatja a jogszab\u00e1lyi megfelel\u0151s\u00e9get, \u00e9s megv\u00e9dheti a betegbiztons\u00e1got.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3344b6 elementor-widget elementor-widget-text-editor\" data-id=\"a3344b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\"><strong data-start=\"5675\" data-end=\"5746\">Az ISO 11040-4 szabv\u00e1nynak megfelel\u0151 fecskend\u0151-vizsg\u00e1lati megold\u00e1sokat keres?<\/strong><\/p><p class=\"\" data-start=\"5420\" data-end=\"5503\">Kapcsolat <strong data-start=\"5757\" data-end=\"5787\">Cell Instruments Co., Ltd.<\/strong> m\u00e9g ma szak\u00e9rt\u0151i \u00fatmutat\u00e1st \u00e9s szem\u00e9lyre szabott tesztel\u00e9si rendszereket a fecskend\u0151min\u0151s\u00e9g-ellen\u0151rz\u00e9si ig\u00e9nyeihez.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2073","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/hu\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/posts\/2073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/comments?post=2073"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/posts\/2073\/revisions"}],"predecessor-version":[{"id":2084,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/posts\/2073\/revisions\/2084"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/media?parent=2073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/categories?post=2073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/hu\/wp-json\/wp\/v2\/tags?post=2073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}