{"id":2178,"date":"2025-06-17T02:28:20","date_gmt":"2025-06-17T02:28:20","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2178"},"modified":"2025-06-17T02:28:23","modified_gmt":"2025-06-17T02:28:23","slug":"syringeability-test","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/he\/syringeability-test\/","title":{"rendered":"Syringeability Test &#8211; Syringe Functionality Testing"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2178\" class=\"elementor elementor-2178\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8753d05 e-flex e-con-boxed e-con e-parent\" data-id=\"8753d05\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0e060d3 elementor-widget elementor-widget-heading\" data-id=\"0e060d3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Syringeability Test<br><small>Syringe Functionality Testing<\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d728c3 elementor-widget elementor-widget-text-editor\" data-id=\"4d728c3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"463\" data-end=\"1040\">Ensuring that a syringe performs reliably during actual use is critical in both clinical and laboratory environments. The <em data-start=\"585\" data-end=\"606\">syringeability test<\/em> evaluates a syringe\u2019s ability to deliver its contents smoothly, safely, and consistently. More than a simple flow assessment, it also considers factors such as injection force, obstruction, ease of administration, and compatibility with various substances.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d40829 elementor-widget elementor-widget-heading\" data-id=\"4d40829\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Importance of Syringeability Testing<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5fbb7c8 e-con-full e-flex e-con e-child\" data-id=\"5fbb7c8\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9de9d23 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"9de9d23\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1107\" data-end=\"1340\">The <em data-start=\"1111\" data-end=\"1132\">syringeability test<\/em> ensures that syringes deliver drug products without clogging, excessive force, or loss of dose. For drugs in prefilled syringes, biologics, or viscous formulations, syringeability becomes even more critical.<\/p><p data-start=\"1342\" data-end=\"1624\">Pharmaceutical manufacturers, R&amp;D professionals, and QA\/QC teams rely on these tests to validate product design, packaging, and patient usability. Poor syringeability can lead to patient discomfort, underdosing, or failed delivery\u2014risks that regulatory authorities strictly monitor.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0baeef1 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"0baeef1\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/he\/syringe-needle-penetration-test\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/Syringeability-Test-Syringe-Functionality-Testing.webp\" class=\"attachment-full size-full wp-image-2180\" alt=\"Syringeability Test - Syringe Functionality Testing\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/Syringeability-Test-Syringe-Functionality-Testing.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/Syringeability-Test-Syringe-Functionality-Testing-300x200.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58f6cc6 elementor-widget elementor-widget-heading\" data-id=\"58f6cc6\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Relevant Standards for Syringe Functionality Testing<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8616288 elementor-widget elementor-widget-text-editor\" data-id=\"8616288\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1689\" data-end=\"1908\">To ensure compliance and consistency, multiple ISO standards outline the procedures for syringe functionality and syringeability evaluation. Each provides a specific context for different syringe types and applications.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9bd0812 elementor-widget elementor-widget-heading\" data-id=\"9bd0812\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Syringe Functionality Testing per ISO 11040-4 Annex E<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e1c83b elementor-widget elementor-widget-text-editor\" data-id=\"5e1c83b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1969\" data-end=\"2117\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/he\/syringe-glide-force-testing-iso-11040-4\/\">ISO 11040-4<\/a> focuses on <em data-start=\"1992\" data-end=\"2030\">glass barrels for prefilled syringes<\/em>. Annex E outlines a syringeability test to verify functional performance, emphasizing:<\/p><ul><li>Plunger force consistency<\/li><li>Break-loose and glide force measurement<\/li><li>Absence of leakage or stalling<\/li><li>Compatibility with viscous or particulate-filled solutions<\/li><\/ul><p data-start=\"2290\" data-end=\"2393\">Testing involves precise control of injection speed, force, and volume to simulate real-life scenarios.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28a364e elementor-widget elementor-widget-heading\" data-id=\"28a364e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Syringeability Criteria in ISO 7886-1 Annex E<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e48087f elementor-widget elementor-widget-text-editor\" data-id=\"e48087f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2446\" data-end=\"2559\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/he\/iso-7886-1\/\">ISO 7886-1<\/a> applies to <em data-start=\"2468\" data-end=\"2512\">sterile hypodermic syringes for single use<\/em>. In Annex E, the syringeability test examines:<\/p><ul><li data-start=\"2563\" data-end=\"2603\">The force required to expel the liquid<\/li><li data-start=\"2606\" data-end=\"2653\">Smoothness and continuity of plunger movement<\/li><li data-start=\"2656\" data-end=\"2702\">Ease of administration over various conditions<\/li><\/ul><p data-start=\"2704\" data-end=\"2816\">This standard is critical for disposable syringe manufacturers looking to meet international quality benchmarks.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c78a9d2 elementor-widget elementor-widget-heading\" data-id=\"c78a9d2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">High-Volume and Specialty Device Testing: ISO 8537 Annex C<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed65acf elementor-widget elementor-widget-text-editor\" data-id=\"ed65acf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2882\" data-end=\"3061\">For <em data-start=\"2886\" data-end=\"2904\">insulin syringes<\/em>, ISO 8537 Annex C presents syringe functionality test parameters tailored to low-dose precision and patient-administered injections. The standard evaluates:<\/p><ul><li data-start=\"3065\" data-end=\"3092\">Injection volume accuracy<\/li><li data-start=\"3095\" data-end=\"3150\">Syringe usability for patients with limited dexterity<\/li><li data-start=\"3153\" data-end=\"3195\">Force thresholds under real-use conditions<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-12a7110 elementor-widget elementor-widget-heading\" data-id=\"12a7110\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Device Compatibility in ISO 11499<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea4c574 elementor-widget elementor-widget-text-editor\" data-id=\"ea4c574\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3236\" data-end=\"3500\">ISO 11499 guides testing of <em data-start=\"3264\" data-end=\"3302\">single-use injectors for medical use<\/em>, ensuring performance consistency and drug compatibility. Syringeability testing ensures that resistance and blockage do not hinder dose delivery, especially in injectors used for chronic diseases.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-307dc22 elementor-widget elementor-widget-heading\" data-id=\"307dc22\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Autoinjector and Pen System Evaluation: ISO 11608-3<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f77d56a elementor-widget elementor-widget-text-editor\" data-id=\"f77d56a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3559\" data-end=\"3679\">ISO 11608-3 details requirements for <em data-start=\"3596\" data-end=\"3628\">needle-based injection systems<\/em> like autoinjectors and pen injectors. It includes:<\/p><ul><li data-start=\"3683\" data-end=\"3743\">Assessment of syringe interaction with the delivery device<\/li><li data-start=\"3746\" data-end=\"3797\">Resistance to plunger deformation or force surges<\/li><li data-start=\"3800\" data-end=\"3853\">Suitability for use with a broad range of medications<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-87faa7a elementor-widget elementor-widget-heading\" data-id=\"87faa7a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conducting the Syringeability Test: Parameters and Equipment<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3398a8 elementor-widget elementor-widget-text-editor\" data-id=\"b3398a8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3926\" data-end=\"3987\">A successful <em data-start=\"3939\" data-end=\"3960\">syringeability test<\/em> includes multiple factors:<\/p><ul><li><strong data-start=\"3991\" data-end=\"4012\">Break-loose force<\/strong>: the initial force to start plunger movement<\/li><li><strong data-start=\"4062\" data-end=\"4077\">Glide force<\/strong>: force required for continuous motion<\/li><li><strong data-start=\"4120\" data-end=\"4133\">Flow rate<\/strong>: measured at specified injection speeds<\/li><li><strong data-start=\"4178\" data-end=\"4195\">Back pressure<\/strong>: resistance caused by formulation characteristics<\/li><\/ul><p data-start=\"4249\" data-end=\"4605\"><strong data-start=\"4249\" data-end=\"4269\">Cell Instruments<\/strong> offers high-precision testing systems ideal for syringeability evaluations. Our <strong>NPT-01\u00a0Syringeability Testing Machine<\/strong>\u00a0is engineered to comply with <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a>, ISO 7886-1, and ISO 11608-3. It supports programmable speed, plunger force, and injection simulation under controlled conditions, providing <strong data-start=\"4567\" data-end=\"4604\">high reproducibility and accuracy<\/strong>.<\/p><p data-start=\"4607\" data-end=\"4817\">Whether you\u2019re testing prefilled syringes, biologic drugs, or innovative injector systems, Cell Instruments delivers <strong data-start=\"4724\" data-end=\"4768\">customized syringeability test solutions<\/strong> for R&amp;D, QA\/QC, and production validation needs.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fdac9e6 elementor-widget elementor-widget-heading\" data-id=\"fdac9e6\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Best Practices for Reliable Syringeability Testing<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35ed1dc elementor-widget elementor-widget-text-editor\" data-id=\"35ed1dc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4880\" data-end=\"4935\">To achieve consistent and regulatory-compliant results:<\/p><ul><li data-start=\"4939\" data-end=\"5091\"><strong data-start=\"4939\" data-end=\"4971\">Use standardized test fluids<\/strong>, particularly if testing for general functionality. For actual formulations, consider viscosity and particle content.<\/li><li data-start=\"5094\" data-end=\"5177\"><strong data-start=\"5094\" data-end=\"5132\">Calibrate the instrument regularly<\/strong> to ensure force and displacement accuracy.<\/li><li data-start=\"5180\" data-end=\"5262\"><strong data-start=\"5180\" data-end=\"5218\">Simulate realistic injection rates<\/strong>, such as those used in clinical settings.<\/li><li data-start=\"5265\" data-end=\"5375\"><strong data-start=\"5265\" data-end=\"5292\">Document all parameters<\/strong>, including syringe type, formulation, ambient temperature, and test environment.<\/li><\/ul><p data-start=\"5377\" data-end=\"5517\">Additionally, integrating automation\u2014such as robotic plungers or synchronized flow sensors\u2014can improve repeatability and reduce human error.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38012ae elementor-widget elementor-widget-heading\" data-id=\"38012ae\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why Choose Cell Instruments' Syringeability Testing Machine<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-217206a elementor-widget elementor-widget-text-editor\" data-id=\"217206a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5585\" data-end=\"5727\">As a <strong data-start=\"5590\" data-end=\"5650\">specialized manufacturer of <a href=\"https:\/\/www.pharmacopoeiatest.com\/he\/syringe-needle-penetration-test\/\">Syringeability Testing Machine<\/a><\/strong>, Cell Instruments supports pharmaceutical and medical device customers with:<\/p><ul><li data-start=\"5731\" data-end=\"5810\"><strong data-start=\"5731\" data-end=\"5765\">Customizable testing solutions<\/strong> for diverse syringe types and formulations<\/li><li data-start=\"5813\" data-end=\"5897\"><strong data-start=\"5813\" data-end=\"5849\">Compliance with global standards<\/strong> like ISO 11040-4, ISO 7886-1, and ISO 11608-3<\/li><li data-start=\"5900\" data-end=\"5973\"><strong data-start=\"5900\" data-end=\"5928\">Expert technical support<\/strong> to help clients optimize their test setups<\/li><li data-start=\"5976\" data-end=\"6055\"><strong data-start=\"5976\" data-end=\"5999\">Automation upgrades<\/strong> for higher throughput and reduced manual intervention<\/li><\/ul><p data-start=\"6057\" data-end=\"6171\">Our instruments are widely used by <strong data-start=\"6092\" data-end=\"6170\">pharmaceutical labs, packaging developers, and regulatory compliance teams<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringeability TestSyringe Functionality Testing Ensuring that a syringe performs reliably during actual use is critical in both clinical and laboratory environments. The syringeability test evaluates a syringe\u2019s ability to deliver its contents smoothly, safely, and consistently. More than a simple flow assessment, it also considers factors such as injection force, obstruction, ease of administration, and [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2178","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/he\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Syringeability TestSyringe Functionality Testing Ensuring that a syringe performs reliably during actual use is critical in both clinical and laboratory environments. The syringeability test evaluates a syringe\u2019s ability to deliver its contents smoothly, safely, and consistently. More than a simple flow assessment, it also considers factors such as injection force, obstruction, ease of administration, and&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/posts\/2178","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/comments?post=2178"}],"version-history":[{"count":4,"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/posts\/2178\/revisions"}],"predecessor-version":[{"id":2183,"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/posts\/2178\/revisions\/2183"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/media?parent=2178"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/categories?post=2178"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/he\/wp-json\/wp\/v2\/tags?post=2178"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}