{"id":2610,"date":"2026-05-07T08:15:19","date_gmt":"2026-05-07T08:15:19","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2610"},"modified":"2026-05-07T08:46:47","modified_gmt":"2026-05-07T08:46:47","slug":"iso-8537","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/fr\/iso-8537\/","title":{"rendered":"ISO 8537"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2610\" class=\"elementor elementor-2610\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0662493 e-flex e-con-boxed e-con e-parent\" data-id=\"0662493\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fc37773 elementor-widget elementor-widget-heading\" data-id=\"fc37773\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8537 <br><small><small>Tests de bon fonctionnement des seringues \u00e0 insuline<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-25d7b19 e-con-full e-flex e-con e-child\" data-id=\"25d7b19\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d257432 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"d257432\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"314\" data-end=\"683\">La norme ISO 8537 d\u00e9finit les exigences de performance et d'essai pour <strong data-start=\"378\" data-end=\"417\">seringues \u00e0 insuline st\u00e9riles \u00e0 usage unique<\/strong>, avec ou sans aiguilles. Cette norme porte sur la s\u00e9curit\u00e9, la fonctionnalit\u00e9, l'\u00e9tanch\u00e9it\u00e9, la pr\u00e9cision du dosage et la fiabilit\u00e9 op\u00e9rationnelle des seringues. Les fabricants et les laboratoires de contr\u00f4le qualit\u00e9 s'appuient sur la norme ISO 8537 pour v\u00e9rifier que les seringues fonctionnent de mani\u00e8re constante lors de leur utilisation clinique.<\/p><p data-start=\"685\" data-end=\"1021\">Pour les fabricants de seringues, la conformit\u00e9 \u00e0 la norme ISO 8537 am\u00e9liore la fiabilit\u00e9 des produits, facilite les d\u00e9marches r\u00e9glementaires et r\u00e9duit les risques li\u00e9s aux fuites, aux d\u00e9faillances du piston ou \u00e0 un dosage impr\u00e9cis. Pour les laboratoires de contr\u00f4le qualit\u00e9, cette norme fournit des proc\u00e9dures valid\u00e9es permettant d'\u00e9valuer les performances des seringues dans des conditions contr\u00f4l\u00e9es.<\/p><p data-start=\"1023\" data-end=\"1207\">\u00c9tant donn\u00e9 que les seringues \u00e0 insuline exigent une administration pr\u00e9cise et une \u00e9tanch\u00e9it\u00e9 stable, <strong data-start=\"1105\" data-end=\"1138\">test de fonctionnalit\u00e9 de la seringue<\/strong> joue un r\u00f4le essentiel tout au long du d\u00e9veloppement et de la production du produit.<\/p><p data-start=\"1209\" data-end=\"1536\">Cell Instruments propose des syst\u00e8mes de test sp\u00e9cialis\u00e9s destin\u00e9s aux fabricants de seringues, aux laboratoires de dispositifs m\u00e9dicaux et aux \u00e9quipes charg\u00e9es de la qualit\u00e9 des conditionnements pharmaceutiques. Ces instruments permettent la mesure automatis\u00e9e de la force, l'\u00e9valuation de l'\u00e9tanch\u00e9it\u00e9 au vide, les tests d'\u00e9tanch\u00e9it\u00e9 et l'analyse de l'espace mort, conform\u00e9ment aux m\u00e9thodologies de la norme ISO 8537.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b939f5 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"5b939f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"630\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes.webp\" class=\"attachment-full size-full wp-image-2613\" alt=\"ISO 8537 \u2014 Essais de fonctionnement des seringues \u00e0 insuline\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes.webp 500w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes-238x300.webp 238w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Syringe-Functionality-Testing-for-Insulin-Syringes-10x12.webp 10w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77936bb elementor-widget elementor-widget-heading\" data-id=\"77936bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 8537 \u2014 Essais de fonctionnement des seringues<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e0637a3 e-grid e-con-full e-con e-child\" data-id=\"e0637a3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d71bda6 elementor-widget elementor-widget-text-editor\" data-id=\"d71bda6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1586\" data-end=\"1769\">La norme ISO 8537 couvre plusieurs \u00e9valuations de performances permettant de d\u00e9terminer si une seringue peut fonctionner de mani\u00e8re s\u00fbre et pr\u00e9cise lors des op\u00e9rations d'aspiration et d'injection. Cette norme pr\u00e9voit des essais portant sur :<\/p><ul data-start=\"1771\" data-end=\"1938\"><li data-section-id=\"1oxsryt\" data-start=\"1771\" data-end=\"1802\">Fuite d'air pendant l'aspiration<\/li><li data-section-id=\"b62ksi\" data-start=\"1803\" data-end=\"1837\">Fuite de liquide sous compression<\/li><li data-section-id=\"143ln9z\" data-start=\"1838\" data-end=\"1862\">Force d'actionnement du piston<\/li><li data-section-id=\"1trb4xg\" data-start=\"1863\" data-end=\"1879\">Int\u00e9grit\u00e9 du joint<\/li><li data-section-id=\"77dvwg\" data-start=\"1880\" data-end=\"1899\">Volume d'espace mort<\/li><li data-section-id=\"gfc932\" data-start=\"1900\" data-end=\"1938\">Fuite au niveau du raccord entre l'aiguille et la buse<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d841201 elementor-widget elementor-widget-text-editor\" data-id=\"d841201\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1940\" data-end=\"1978\">Ces tests permettent aux fabricants d'\u00e9valuer :<\/p><ul data-start=\"1980\" data-end=\"2145\"><li data-section-id=\"4m7yx6\" data-start=\"1980\" data-end=\"2009\">Homog\u00e9n\u00e9it\u00e9 de l'\u00e9tanch\u00e9it\u00e9 du piston<\/li><li data-section-id=\"jtny4m\" data-start=\"2010\" data-end=\"2039\">Int\u00e9grit\u00e9 du corps de la buse et de la buse<\/li><li data-section-id=\"13p4qmo\" data-start=\"2040\" data-end=\"2067\">Efficacit\u00e9 de la lubrification<\/li><li data-section-id=\"1rxkfq7\" data-start=\"2068\" data-end=\"2093\">Pr\u00e9cision de l'administration de la dose<\/li><li data-section-id=\"njxgtt\" data-start=\"2094\" data-end=\"2145\">Fiabilit\u00e9 de la connexion entre la seringue et l'aiguille<\/li><\/ul><p data-start=\"2147\" data-end=\"2270\">Les laboratoires modernes int\u00e8grent de plus en plus souvent des syst\u00e8mes d'analyse automatis\u00e9s afin d'am\u00e9liorer la reproductibilit\u00e9 des r\u00e9sultats et de r\u00e9duire la variabilit\u00e9 li\u00e9e \u00e0 l'intervention de l'op\u00e9rateur.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84b6ee2 elementor-widget elementor-widget-heading\" data-id=\"84b6ee2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Contr\u00f4le d'\u00e9tanch\u00e9it\u00e9 des seringues selon la norme ISO 8537<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d186872 elementor-widget elementor-widget-text-editor\" data-id=\"d186872\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2324\" data-end=\"2507\"><strong data-start=\"2324\" data-end=\"2348\">Test d'\u00e9tanch\u00e9it\u00e9 des seringues<\/strong> est l'une des proc\u00e9dures les plus importantes d\u00e9crites dans la norme ISO 8537. Cette norme \u00e9value \u00e0 la fois les fuites d'air et les fuites de liquide dans diff\u00e9rentes conditions de pression.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-47c3651 e-grid e-con-full e-con e-child\" data-id=\"47c3651\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-bd0c720 e-con-full e-flex e-con e-child\" data-id=\"bd0c720\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb605b0 elementor-widget elementor-widget-heading\" data-id=\"eb605b0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fuite d'air pendant l'aspiration<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1310954 elementor-widget elementor-widget-text-editor\" data-id=\"1310954\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2544\" data-end=\"2684\">Les annexes B et F d\u00e9crivent les m\u00e9thodes permettant de d\u00e9tecter les fuites d'air au niveau du joint du piston et des raccords de l'embout de la seringue dans des conditions de vide.<\/p><p data-start=\"2686\" data-end=\"2719\">La proc\u00e9dure comprend g\u00e9n\u00e9ralement :<\/p><ol data-start=\"2721\" data-end=\"2926\"><li data-section-id=\"8f51yc\" data-start=\"2721\" data-end=\"2764\">Remplir la seringue d'eau distill\u00e9e<\/li><li data-section-id=\"11xil91\" data-start=\"2765\" data-end=\"2822\">Raccordement de la seringue \u00e0 un embout conique compatible<\/li><li data-section-id=\"1w8sjai\" data-start=\"2823\" data-end=\"2852\">Application d'une pression n\u00e9gative<\/li><li data-section-id=\"nzi51v\" data-start=\"2853\" data-end=\"2885\">Surveillance de la stabilit\u00e9 de la pression<\/li><li data-section-id=\"ad7xt5\" data-start=\"2886\" data-end=\"2926\">Constatation de fuites ou de formation de bulles<\/li><\/ol><p data-start=\"2928\" data-end=\"3143\">La norme ISO 8537 sp\u00e9cifie un niveau de vide de <strong data-start=\"2965\" data-end=\"3010\">88 kPa en dessous de la pression atmosph\u00e9rique ambiante<\/strong> pour l'\u00e9valuation des fuites au niveau du syst\u00e8me d'aspiration. Les op\u00e9rateurs surveillent la seringue afin de d\u00e9tecter toute chute de pression, formation de bulles ou d\u00e9tachement du bouchon en caoutchouc.<\/p><p data-start=\"3145\" data-end=\"3164\">Ce test permet de v\u00e9rifier :<\/p><ul data-start=\"3166\" data-end=\"3287\"><li data-section-id=\"31dbu3\" data-start=\"3166\" data-end=\"3189\">Int\u00e9grit\u00e9 du joint de piston<\/li><li data-section-id=\"10m5ixj\" data-start=\"3190\" data-end=\"3222\">Performances d'\u00e9tanch\u00e9it\u00e9 du moyeu d'aiguille<\/li><li data-section-id=\"17ziab\" data-start=\"3223\" data-end=\"3252\">Stabilit\u00e9 du raccordement de la buse<\/li><li data-section-id=\"1way5n8\" data-start=\"3253\" data-end=\"3287\">R\u00e9sistance aux fuites par aspiration<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28726d3 e-con-full e-flex e-con e-child\" data-id=\"28726d3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4cf6b78 elementor-widget elementor-widget-heading\" data-id=\"4cf6b78\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Essais d'\u00e9tanch\u00e9it\u00e9 sous vide : applications pharmaceutiques<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a833751 elementor-widget elementor-widget-text-editor\" data-id=\"a833751\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3339\" data-end=\"3513\">A <strong data-start=\"3341\" data-end=\"3376\">test d'\u00e9tanch\u00e9it\u00e9 sous vide dans le secteur pharmaceutique<\/strong> Cette proc\u00e9dure est essentielle pour les seringues m\u00e9dicales utilis\u00e9es dans l'administration d'insuline, car m\u00eame une fuite minime peut compromettre la pr\u00e9cision du dosage ou la st\u00e9rilit\u00e9.<\/p><p data-start=\"3515\" data-end=\"3595\">Cell Instruments recommande des syst\u00e8mes automatis\u00e9s de contr\u00f4le d'\u00e9tanch\u00e9it\u00e9 sous vide \u00e9quip\u00e9s des \u00e9l\u00e9ments suivants :<\/p><ul data-start=\"3597\" data-end=\"3738\"><li data-section-id=\"le59d7\" data-start=\"3597\" data-end=\"3632\">R\u00e9gulateurs de vide de haute pr\u00e9cision<\/li><li data-section-id=\"1jdfnmj\" data-start=\"3633\" data-end=\"3662\">Surveillance num\u00e9rique de la pression<\/li><li data-section-id=\"105a6xv\" data-start=\"3663\" data-end=\"3684\">Analyse de la d\u00e9croissance des fuites<\/li><li data-section-id=\"fca3b5\" data-start=\"3685\" data-end=\"3712\">Dur\u00e9e de maintien programmable<\/li><li data-section-id=\"cixp3u\" data-start=\"3713\" data-end=\"3738\">Logiciel d'enregistrement de donn\u00e9es<\/li><\/ul><p data-start=\"3740\" data-end=\"3896\">Ces syst\u00e8mes am\u00e9liorent la reproductibilit\u00e9 par rapport aux m\u00e9thodes manuelles d'\u00e9valuation du vide et aident les laboratoires \u00e0 se conformer aux exigences des BPF et de la norme ISO en mati\u00e8re de documentation.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa6d2ef elementor-widget elementor-widget-heading\" data-id=\"fa6d2ef\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">M\u00e9thodes de contr\u00f4le de l'int\u00e9grit\u00e9 des joints des seringues<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0cbf91c elementor-widget elementor-widget-text-editor\" data-id=\"0cbf91c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3943\" data-end=\"4074\">Le <strong data-start=\"3947\" data-end=\"3978\">test d'\u00e9tanch\u00e9it\u00e9 des seringues<\/strong> v\u00e9rifie si du liquide ou de l'air peut s'\u00e9chapper au niveau des interfaces d'\u00e9tanch\u00e9it\u00e9 lors de la compression ou de l'aspiration.<\/p><p data-start=\"4076\" data-end=\"4122\">L'annexe E de la norme ISO 8537 traite des fuites de liquide au niveau :<\/p><ul data-start=\"4124\" data-end=\"4190\"><li data-section-id=\"z11dbz\" data-start=\"4124\" data-end=\"4138\">Joints de piston<\/li><li data-section-id=\"1p89988\" data-start=\"4139\" data-end=\"4167\">Raccords pour embouts de seringues<\/li><li data-section-id=\"1aynqcu\" data-start=\"4168\" data-end=\"4190\">Raccords aiguille\/cylindre<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b34aa1c e-grid e-con-full e-con e-child\" data-id=\"b34aa1c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7afb7c0 elementor-widget elementor-widget-text-editor\" data-id=\"7afb7c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4365\" data-end=\"4389\">Lors des essais, les op\u00e9rateurs g\u00e9n\u00e8rent une pression interne de <strong data-start=\"4251\" data-end=\"4277\">300 kPa de pression manom\u00e9trique<\/strong> et maintenez la pression pendant 30 secondes tout en exer\u00e7ant une force lat\u00e9rale sur le piston.<\/p><p data-start=\"4365\" data-end=\"4389\">La proc\u00e9dure \u00e9value :<\/p><ul data-start=\"4391\" data-end=\"4508\"><li data-section-id=\"1k1t3bu\" data-start=\"4391\" data-end=\"4420\">R\u00e9sistance \u00e0 la d\u00e9formation du joint<\/li><li data-section-id=\"vhj5a5\" data-start=\"4421\" data-end=\"4457\">Fuite en cas de charge lat\u00e9rale<\/li><li data-section-id=\"1ubek41\" data-start=\"4458\" data-end=\"4485\">Stabilit\u00e9 du mouvement du piston<\/li><li data-section-id=\"tj03kp\" data-start=\"4486\" data-end=\"4508\">Int\u00e9grit\u00e9 de la connexion<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5283d17 elementor-widget elementor-widget-text-editor\" data-id=\"5283d17\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4510\" data-end=\"4558\">Un syst\u00e8me fiable de contr\u00f4le de l'int\u00e9grit\u00e9 des joints doit offrir :<\/p><ul data-start=\"4560\" data-end=\"4689\"><li data-section-id=\"1ogn8km\" data-start=\"4560\" data-end=\"4588\">Production d'une pression stable<\/li><li data-section-id=\"81fo7t\" data-start=\"4589\" data-end=\"4617\">Application pr\u00e9cise de la force<\/li><li data-section-id=\"vtwu91\" data-start=\"4618\" data-end=\"4647\">D\u00e9tection des fuites en temps r\u00e9el<\/li><li data-section-id=\"198rl1a\" data-start=\"4648\" data-end=\"4689\">Surveillance des d\u00e9placements en haute r\u00e9solution<\/li><\/ul><p data-start=\"4691\" data-end=\"4868\">Cell Instruments propose des solutions de contr\u00f4le des fuites de pression et de l'int\u00e9grit\u00e9 des joints adapt\u00e9es aux seringues \u00e0 insuline, aux syst\u00e8mes Luer, aux r\u00e9cipients pharmaceutiques et aux applications d'emballage m\u00e9dical.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1592e7 elementor-widget elementor-widget-heading\" data-id=\"d1592e7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test de la force de glissement de la seringue<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86fac58 elementor-widget elementor-widget-text-editor\" data-id=\"86fac58\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4907\" data-end=\"5032\"><strong data-start=\"4907\" data-end=\"4938\">Test de la force de glissement de la seringue<\/strong> mesure la force n\u00e9cessaire pour d\u00e9clencher et maintenir le mouvement du piston lors de l'expulsion du liquide.<\/p><p data-start=\"5034\" data-end=\"5176\">L'annexe C de la norme ISO 8537 prescrit l'utilisation d'une machine d'essai m\u00e9canique pour enregistrer la force d'actionnement du piston lors de l'expulsion de l'eau de la seringue.<\/p><p data-start=\"5178\" data-end=\"5206\">Ce test \u00e9value g\u00e9n\u00e9ralement :<\/p><ul data-start=\"5208\" data-end=\"5305\"><li data-section-id=\"uhip3k\" data-start=\"5208\" data-end=\"5227\">Force de rupture<\/li><li data-section-id=\"d3dsxi\" data-start=\"5228\" data-end=\"5241\">Force de glissement<\/li><li data-section-id=\"td0rt7\" data-start=\"5242\" data-end=\"5267\">Force d'actionnement moyenne<\/li><li data-section-id=\"fqmeyx\" data-start=\"5268\" data-end=\"5305\">Maintenir une force constante tout au long du mouvement<\/li><\/ul><p data-start=\"5307\" data-end=\"5456\">Il est essentiel que la force de glissement reste stable, car une force excessive peut nuire \u00e0 la facilit\u00e9 d'utilisation, tandis qu'une r\u00e9sistance insuffisante peut compromettre le contr\u00f4le du dosage.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18cc935 elementor-widget elementor-widget-heading\" data-id=\"18cc935\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Facteurs cl\u00e9s influant sur la force de glisse<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d703620 e-grid e-con-full e-con e-child\" data-id=\"d703620\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c02067 elementor-widget elementor-widget-text-editor\" data-id=\"5c02067\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5497\" data-end=\"5556\">Plusieurs param\u00e8tres influencent les caract\u00e9ristiques de glissement d'une seringue :<\/p><ul data-start=\"5558\" data-end=\"5684\"><li data-section-id=\"1futzim\" data-start=\"5558\" data-end=\"5591\">Uniformit\u00e9 de la lubrification au silicone<\/li><li data-section-id=\"kuh4lo\" data-start=\"5592\" data-end=\"5617\">Mat\u00e9riau des bouchons en caoutchouc<\/li><li data-section-id=\"53gmea\" data-start=\"5618\" data-end=\"5647\">Pr\u00e9cision dimensionnelle du canon<\/li><li data-section-id=\"5t72bj\" data-start=\"5648\" data-end=\"5666\">Frottement de surface<\/li><li data-section-id=\"198q7yk\" data-start=\"5667\" data-end=\"5684\">Diam\u00e8tre de l'aiguille<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9cd7bf elementor-widget elementor-widget-text-editor\" data-id=\"a9cd7bf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5686\" data-end=\"5745\">Un syst\u00e8me professionnel d'essai de force sur seringues doit comprendre :<\/p><ul data-start=\"5747\" data-end=\"5906\"><li data-section-id=\"ne6nqw\" data-start=\"5747\" data-end=\"5779\">Technologie des capteurs de force de pr\u00e9cision<\/li><li data-section-id=\"1wxb0hx\" data-start=\"5780\" data-end=\"5811\">Contr\u00f4le de mouvement \u00e0 vitesse constante<\/li><li data-section-id=\"h51txm\" data-start=\"5812\" data-end=\"5847\">Analyse de la courbe force-d\u00e9placement<\/li><li data-section-id=\"gjpujf\" data-start=\"5848\" data-end=\"5874\">Dispositifs de test r\u00e9glables<\/li><li data-section-id=\"19afykk\" data-start=\"5875\" data-end=\"5906\">Acquisition informatis\u00e9e de donn\u00e9es<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef0db14 elementor-widget elementor-widget-text-editor\" data-id=\"ef0db14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Cell Instruments recommande des syst\u00e8mes universels d'essai des mat\u00e9riaux \u00e9quip\u00e9s de fixations de seringues sur mesure pour les essais de force de piston conformes \u00e0 la norme ISO 8537.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4d61be elementor-widget elementor-widget-heading\" data-id=\"c4d61be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mesure de l'espace mort pour les seringues \u00e0 insuline<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2c205a elementor-widget elementor-widget-text-editor\" data-id=\"a2c205a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6115\" data-end=\"6239\"><strong data-start=\"6115\" data-end=\"6141\">Mesure de l'espace mort<\/strong> d\u00e9termine le volume de liquide r\u00e9siduel restant \u00e0 l'int\u00e9rieur de la seringue apr\u00e8s avoir enfonc\u00e9 le piston \u00e0 fond.<\/p><p data-start=\"6241\" data-end=\"6394\">Un faible volume mort est particuli\u00e8rement important pour les seringues \u00e0 insuline, car les r\u00e9sidus de m\u00e9dicament peuvent nuire \u00e0 la pr\u00e9cision du dosage et accro\u00eetre le gaspillage de m\u00e9dicaments.<\/p><p data-start=\"6396\" data-end=\"6484\">L'annexe D de la norme ISO 8537 d\u00e9crit une m\u00e9thode d'essai gravim\u00e9trique fond\u00e9e sur la mesure de la masse d'eau.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3582f04 e-grid e-con-full e-con e-child\" data-id=\"3582f04\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-e4e0eef e-con-full e-flex e-con e-child\" data-id=\"e4e0eef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ee7135a elementor-widget elementor-widget-heading\" data-id=\"ee7135a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Proc\u00e9dure de mesure de l'espace mort<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60271a8 elementor-widget elementor-widget-text-editor\" data-id=\"60271a8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6524\" data-end=\"6547\">La proc\u00e9dure comprend :<\/p><ol data-start=\"6549\" data-end=\"6719\"><li data-section-id=\"5n54cf\" data-start=\"6549\" data-end=\"6578\">Peser la seringue vide<\/li><li data-section-id=\"1po99wn\" data-start=\"6579\" data-end=\"6622\">Remplir la seringue d'eau distill\u00e9e<\/li><li data-section-id=\"q59tts\" data-start=\"6623\" data-end=\"6656\">\u00c9vacuer compl\u00e8tement l'eau<\/li><li data-section-id=\"1w7zx7c\" data-start=\"6657\" data-end=\"6682\">Pes\u00e9e de la seringue<\/li><li data-section-id=\"1bth81y\" data-start=\"6683\" data-end=\"6719\">Calcul du volume d'eau retenue<\/li><\/ol><p data-start=\"6721\" data-end=\"6791\">La quantit\u00e9 d'eau restante correspond au volume de l'espace mort de la seringue.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c8b1057 e-con-full e-flex e-con e-child\" data-id=\"c8b1057\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c4747c elementor-widget elementor-widget-heading\" data-id=\"7c4747c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Importance des tests en espace mort<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac04fa1 elementor-widget elementor-widget-text-editor\" data-id=\"ac04fa1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"6831\" data-end=\"6883\">La mesure de l'espace mort permet aux fabricants d'\u00e9valuer :<\/p><ul data-start=\"6885\" data-end=\"6993\"><li data-section-id=\"1yt1bzi\" data-start=\"6885\" data-end=\"6902\">Pr\u00e9cision du dosage<\/li><li data-section-id=\"to7kax\" data-start=\"6903\" data-end=\"6928\">R\u00e9tention r\u00e9siduelle du m\u00e9dicament<\/li><li data-section-id=\"1uwyw95\" data-start=\"6929\" data-end=\"6962\">Optimisation de la conception des seringues<\/li><li data-section-id=\"19wzgi9\" data-start=\"6963\" data-end=\"6993\">Efficacit\u00e9 de la conception du moyeu d'aiguille<\/li><\/ul><p data-start=\"6995\" data-end=\"7121\">Cell Instruments propose des solutions d'int\u00e9gration de balances de pr\u00e9cision et des plateformes de test sur mesure pour l'analyse automatis\u00e9e de l'espace mort.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8195461 elementor-widget elementor-widget-heading\" data-id=\"8195461\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9quipements d'essai recommand\u00e9s pour la conformit\u00e9 \u00e0 la norme ISO 8537<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-129d4b6 elementor-widget elementor-widget-text-editor\" data-id=\"129d4b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"7186\" data-end=\"7244\">Pour garantir la conformit\u00e9 \u00e0 la norme ISO 8537, les laboratoires ont g\u00e9n\u00e9ralement recours \u00e0 :<\/p><div class=\"TyagGW_tableContainer\"><div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"7246\" data-end=\"7579\"><thead data-start=\"7246\" data-end=\"7284\"><tr data-start=\"7246\" data-end=\"7284\"><th class=\"\" data-start=\"7246\" data-end=\"7258\" data-col-size=\"sm\">\u00c9l\u00e9ment de test<\/th><th class=\"\" data-start=\"7258\" data-end=\"7284\" data-col-size=\"sm\">Instrument recommand\u00e9<\/th><\/tr><\/thead><tbody data-start=\"7295\" data-end=\"7579\"><tr data-start=\"7295\" data-end=\"7342\"><td style=\"text-align: center;\" data-start=\"7295\" data-end=\"7320\" data-col-size=\"sm\">Contr\u00f4le d'\u00e9tanch\u00e9it\u00e9 sous vide<\/td><td style=\"text-align: center;\" data-start=\"7320\" data-end=\"7342\" data-col-size=\"sm\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/vacuum-leak-tester-for-syringe-plunger-stopper-and-seal\/\">SLT-02 Testeur d'\u00e9tanch\u00e9it\u00e9 de seringue<\/a><\/td><\/tr><tr data-start=\"7402\" data-end=\"7456\"><td style=\"text-align: center;\" data-start=\"7402\" data-end=\"7427\" data-col-size=\"sm\">Force d'actionnement du piston<\/td><td style=\"text-align: center;\" data-start=\"7427\" data-end=\"7456\" data-col-size=\"sm\"><p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/syringes-plunger-glide-force-tester\/\">SSR-01 Testeur de r\u00e9sistance au glissement des seringues<\/a><\/p><\/td><\/tr><tr data-start=\"7457\" data-end=\"7513\"><td style=\"text-align: center;\" data-start=\"7457\" data-end=\"7479\" data-col-size=\"sm\">Analyse des espaces morts<\/td><td style=\"text-align: center;\" data-start=\"7479\" data-end=\"7513\" data-col-size=\"sm\">Syst\u00e8me de mesure gravim\u00e9trique<\/td><\/tr><tr data-start=\"7514\" data-end=\"7579\"><td style=\"text-align: center;\" data-start=\"7514\" data-end=\"7543\" data-col-size=\"sm\">Contr\u00f4le d'\u00e9tanch\u00e9it\u00e9 des raccords<\/td><td style=\"text-align: center;\" data-start=\"7543\" data-end=\"7579\" data-col-size=\"sm\"><div class=\"elementor-element elementor-element-9d87235 elementor-widget elementor-widget-heading\" data-id=\"9d87235\" data-element_type=\"widget\" data-widget_type=\"heading.default\"><div class=\"elementor-widget-container\"><p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/syringe-plunger-seal-integrity-tester\/\">SPPT-01 Testeur d'\u00e9tanch\u00e9it\u00e9 \u00e0 pression positive sur seringue<\/a><\/p><\/div><\/div><\/td><\/tr><\/tbody><\/table><\/div><\/div><p data-start=\"7581\" data-end=\"7773\">Cell Instruments propose des solutions d'automatisation sur mesure destin\u00e9es aux laboratoires de contr\u00f4le des seringues, notamment des syst\u00e8mes \u00e0 plusieurs stations, des logiciels de gestion des donn\u00e9es et des plateformes int\u00e9gr\u00e9es de contr\u00f4le qualit\u00e9.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b08dc9a elementor-widget elementor-widget-heading\" data-id=\"b08dc9a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e8bf18 elementor-widget elementor-widget-text-editor\" data-id=\"3e8bf18\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong>Qu'est-ce que la norme ISO 8537 ?<\/strong><br \/>La norme ISO 8537 est une norme internationale qui d\u00e9finit les exigences et les m\u00e9thodes d'essai applicables aux seringues \u00e0 insuline st\u00e9riles \u00e0 usage unique, avec ou sans aiguille.<\/p><p><strong>Qu'est-ce que le contr\u00f4le d'\u00e9tanch\u00e9it\u00e9 des seringues selon la norme ISO 8537 ?<\/strong><br \/>Le contr\u00f4le d'\u00e9tanch\u00e9it\u00e9 des seringues permet d'\u00e9valuer les fuites d'air ou de liquide au niveau des joints du piston, des embouts de seringue et des raccords d'aiguille, dans des conditions de vide ou de pression.<\/p><p><strong>Pourquoi les essais de r\u00e9sistance au glissement des seringues sont-ils importants ?<\/strong><br \/>Les essais de force de glissement permettent de v\u00e9rifier que le piston se d\u00e9place de mani\u00e8re fluide et r\u00e9guli\u00e8re, garantissant ainsi un d\u00e9bit d'insuline pr\u00e9cis et une bonne maniabilit\u00e9 de la seringue.<\/p><p><strong>Qu'est-ce qu'un test d'int\u00e9grit\u00e9 du joint d'une seringue ?<\/strong><br \/>Un test d'int\u00e9grit\u00e9 du joint d'une seringue permet de d\u00e9terminer si les interfaces d'\u00e9tanch\u00e9it\u00e9 emp\u00eachent toute fuite dans des conditions de compression et d'aspiration.<\/p><p><strong>Comment proc\u00e8de-t-on \u00e0 la mesure de l'espace mort ?<\/strong><br \/>La mesure de l'espace mort repose sur une m\u00e9thode gravim\u00e9trique qui compare la masse de la seringue avant et apr\u00e8s l'expulsion de l'eau afin de d\u00e9terminer le volume de liquide r\u00e9siduel.<\/p><p><strong>Quels sont les instruments utilis\u00e9s pour <a href=\"https:\/\/www.iso.org\/standard\/60510.html\" target=\"_blank\" rel=\"noopener\">ISO 8537<\/a> des tests ?<\/strong><br \/>Parmi les instruments couramment utilis\u00e9s, on trouve les testeurs de fuites sous vide, les machines d'essai universelles, les syst\u00e8mes de chute de pression et les appareils de mesure gravim\u00e9trique.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 8537 \u2014 Essais de fonctionnalit\u00e9 des seringues \u00e0 insuline : la norme ISO 8537 d\u00e9finit les exigences de performance et d\u2019essai applicables aux seringues \u00e0 insuline st\u00e9riles \u00e0 usage unique, avec ou sans aiguille. Cette norme porte notamment sur la s\u00e9curit\u00e9 des seringues, leur fonctionnalit\u00e9, leur \u00e9tanch\u00e9it\u00e9, la pr\u00e9cision du dosage et leur fiabilit\u00e9 op\u00e9rationnelle. Les fabricants et les laboratoires de contr\u00f4le qualit\u00e9 s'appuient sur la norme ISO 8537 pour v\u00e9rifier que les seringues fonctionnent de mani\u00e8re constante lors de leur utilisation clinique. [\u2026]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2610","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/fr\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 8537 Syringe Functionality Testing for Insulin Syringe ISO 8537 specifies the performance and testing requirements for sterile single-use insulin syringes, with or without needles. The standard focuses on syringe safety, functionality, sealing performance, dosage accuracy, and operational reliability. Manufacturers and quality laboratories use ISO 8537 to verify that syringes perform consistently during clinical use.\u2026","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/comments?post=2610"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2610\/revisions"}],"predecessor-version":[{"id":2624,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2610\/revisions\/2624"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/media?parent=2610"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/categories?post=2610"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/tags?post=2610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}