{"id":2267,"date":"2025-07-21T07:08:11","date_gmt":"2025-07-21T07:08:11","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2267"},"modified":"2025-07-21T07:21:09","modified_gmt":"2025-07-21T07:21:09","slug":"ampoule-mechanical-strength-tester","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/fr\/ampoule-mechanical-strength-tester\/","title":{"rendered":"Testeur de r\u00e9sistance m\u00e9canique des ampoules selon ISO 9187"},"content":{"rendered":"<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-fccd8bb\" id=\"introduction\" data-block-id=\"fccd8bb\"><h2 class=\"stk-block-heading__text\">Introduction<\/h2><\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-7387b849 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-uagb-container uagb-block-61ff3f36 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/category\/product\/ampoule-break-test\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp\" alt=\"testeur de r\u00e9sistance m\u00e9canique des ampoules\" class=\"wp-image-2280\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><figcaption class=\"wp-element-caption\">BST-01 Testeur de rupture d'ampoule <\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c9valuation pr\u00e9cise des <strong>testeur de r\u00e9sistance m\u00e9canique des ampoules <\/strong>est essentielle pour le contr\u00f4le de la qualit\u00e9 des produits pharmaceutiques. Les ampoules de verre utilis\u00e9es pour les solutions injectables doivent \u00eatre suffisamment solides pour maintenir la st\u00e9rilit\u00e9 pendant le transport et le stockage, tout en \u00e9tant suffisamment faciles \u00e0 ouvrir sans force excessive. La norme ISO 9187 fournit des proc\u00e9dures d'essai normalis\u00e9es pour \u00e9valuer ces qualit\u00e9s, en particulier <strong>mesure de la force de rupture des ampoules de verre<\/strong>. Cet article vous guide tout au long de la proc\u00e9dure de test en utilisant le logiciel <strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/category\/product\/ampoule-break-test\/\">BST-01 <strong>Testeur de r\u00e9sistance m\u00e9canique des ampoules<\/strong><\/a><\/strong> de Cell Instruments, garantissant la conformit\u00e9 r\u00e9glementaire et la s\u00e9curit\u00e9 des produits.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-2c9d7c5\" id=\"breaking-force-measurement-for-glass-ampoules-using-bst-01-ampoule-tester\" data-block-id=\"2c9d7c5\"><h2 class=\"stk-block-heading__text\">Mesure de la force de rupture des ampoules en verre \u00e0 l'aide du testeur d'ampoules BST-01<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Force de rupture<\/strong> est un param\u00e8tre cl\u00e9 de l'int\u00e9grit\u00e9 m\u00e9canique des ampoules. Les normes ISO 9187-1:2010 et ISO 9187-2 d\u00e9finissent des crit\u00e8res stricts pour mesurer cette force au niveau de la constriction de l'ampoule, g\u00e9n\u00e9ralement marqu\u00e9e par un anneau en c\u00e9ramique ou un pigment color\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le <strong>BST-01 <strong>Testeur de r\u00e9sistance m\u00e9canique des ampoules<\/strong><\/strong> de Cell Instruments est sp\u00e9cialement con\u00e7u \u00e0 cet effet. Il fournit <strong>mesures de force pr\u00e9cises et reproductibles<\/strong>, en accord avec <strong>ISO 7500-1<\/strong> et <strong>ISO 9187<\/strong> sp\u00e9cifications. Avec une vitesse d'essai contr\u00f4l\u00e9e de 10 mm\/min et une plage de force de 200 N, le BST-01 garantit des r\u00e9sultats fiables pour les laboratoires de contr\u00f4le de la qualit\u00e9 et les installations de fabrication.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Caract\u00e9ristiques principales de BST-01 :<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Enti\u00e8rement conforme \u00e0 la m\u00e9thode d'essai ISO 9187<\/li>\n\n\n\n<li>Syst\u00e8me int\u00e9gr\u00e9 de mesure de la force de traction<\/li>\n\n\n\n<li>Vitesse programmable et enregistrement des donn\u00e9es<\/li>\n\n\n\n<li>Id\u00e9al pour <strong>mesure de la force de rupture des ampoules de verre<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L'utilisation du testeur BST-01 permet non seulement d'am\u00e9liorer l'efficacit\u00e9 mais aussi de d\u00e9tecter <strong>recuit incoh\u00e9rent<\/strong> ou <strong>faible r\u00e9sistance \u00e0 l'hydrolyse<\/strong>ce qui pourrait compromettre la s\u00e9curit\u00e9 des patients.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-66f05dd\" id=\"a-href-https-www-pharmacopoeiatest-com-iso-9187-1-iso-9187-a-standards-technical-testing-guidelines\" data-block-id=\"66f05dd\"><h2 class=\"stk-block-heading__text\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/iso-9187-1\/\">ISO 9187<\/a> Normes : Lignes directrices pour les essais techniques<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">La norme ISO 9187 d\u00e9crit la m\u00e9thodologie et les crit\u00e8res d'acceptation pour l'\u00e9valuation des \u00e9l\u00e9ments suivants <strong>r\u00e9sistance m\u00e9canique des ampoules<\/strong>. Vous trouverez ci-dessous les \u00e9l\u00e9ments essentiels \u00e0 respecter :<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">R\u00e9sistance \u00e0 l'hydrolyse<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les ampoules doivent \u00eatre conformes <strong>ISO 4802 HC1<\/strong> classe de r\u00e9sistance hydrolytique, garantissant la durabilit\u00e9 de la surface interne contre les solutions aqueuses.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Qualit\u00e9 du recuit<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les ampoules ne doivent pas pr\u00e9senter de retard optique au-del\u00e0 de <strong>50 nm\/mm d'\u00e9paisseur de verre<\/strong>. Un recuit inad\u00e9quat augmente les tensions internes, ce qui entra\u00eene des ruptures lors de la manipulation ou du transport.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Proc\u00e9dure d'essai de force de rupture<\/h3>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-dda3e97\" data-block-id=\"dda3e97\"><p class=\"stk-block-text__text\">    <strong>1. appareil :<\/strong> Utiliser un appareil d'essai de traction conforme \u00e0 la norme <strong>ISO 7500-1<\/strong>tels que le <strong>BST-01 Testeur de r\u00e9sistance m\u00e9canique des ampoules<\/strong>.<br>    <strong>2. vitesse d'essai :<\/strong> 10 mm\/min ou une puissance \u00e9quivalente de 20 N\/s.<br>    <strong>3.Force Gamme :<\/strong> Au moins 200 N.<br>    <strong>4 Pr\u00e9paration de l'\u00e9chantillon :<\/strong><br>             Condition \u00e0 <strong>20 \u00b1 5 \u00b0C<\/strong>.<br>             S\u00e9lectionner les \u00e9chantillons en fonction de <strong>ISO 2859-1<\/strong>niveau d'inspection S-4.<br>    <strong>5. Mise en place :<\/strong><br>            Placer l'ampoule entre deux barres.<br>            Appliquer une force \u00e0 90\u00b0 par rapport \u00e0 son axe.<br>            La casse doit \u00eatre propre et la force enregistr\u00e9e.<\/p><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Position et stabilit\u00e9 du point de rupture (ISO 9187-2)<\/h3>\n\n\n\n<figure class=\"wp-block-embed alignright is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"ISO 9187-1 testeur de rupture d&#039;ampoule BST-01\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/fL78KBZwj3g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-74b8b2e\" data-block-id=\"74b8b2e\"><p class=\"stk-block-text__text\">                                               Le point de rupture marqu\u00e9 d'une couleur doit \u00eatre <strong>centr\u00e9 \u00b11 mm<\/strong>.<br>                                               Il doit r\u00e9sister :<br>                                                   <strong>30 minutes \u00e0 120 \u00b0C<\/strong>, puis l'immersion dans <strong>Eau \u00e0 30 \u00b0C<\/strong><br>                                                   <strong>Cycles de st\u00e9rilisation et solvants de nettoyage<\/strong><br>                                               Le non-respect de ces directives peut entra\u00eener une force de rupture excessive, rendant l'ampoule dangereuse ou non conforme.<\/p><\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-d535f6f\" id=\"why-mechanical-strength-testing-matters\" data-block-id=\"d535f6f\"><h2 class=\"stk-block-heading__text\">                L'importance des essais de r\u00e9sistance m\u00e9canique<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Ex\u00e9cution <strong>test de r\u00e9sistance m\u00e9canique de l'ampoule<\/strong> ne se limite pas \u00e0 l'adoption d'un r\u00e8glement. C'est une garantie :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>S\u00e9curit\u00e9 des patients :<\/strong> \u00e9viter les particules de verre ou les bris violents<\/li>\n\n\n\n<li><strong>Coh\u00e9rence de la fabrication :<\/strong> d\u00e9tecter les d\u00e9fauts \u00e0 un stade pr\u00e9coce<\/li>\n\n\n\n<li><strong>Conformit\u00e9 r\u00e9glementaire :<\/strong> \u00e9viter les rejets et les rappels<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Exemple concret :<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Une usine pharmaceutique de premier plan utilisant le BST-01 a obtenu une <strong>R\u00e9duction 30%<\/strong> de plaintes li\u00e9es \u00e0 la rupture d'ampoules apr\u00e8s la normalisation des tests conformes \u00e0 la norme ISO 9187.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-25932c4\" id=\"choosing-the-right-ampoule-mechanical-strength-tester\" data-block-id=\"25932c4\"><h2 class=\"stk-block-heading__text\">Choisir le bon testeur de r\u00e9sistance m\u00e9canique des ampoules.<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Cell Instruments est sp\u00e9cialis\u00e9 dans les syst\u00e8mes d'essais m\u00e9caniques de haute pr\u00e9cision. Les <strong>BST-01 Testeur de r\u00e9sistance m\u00e9canique des ampoules<\/strong> est optimis\u00e9 pour <strong>test de r\u00e9sistance m\u00e9canique de l'ampoule<\/strong> et favorise l'automatisation, la tra\u00e7abilit\u00e9 des donn\u00e9es et la facilit\u00e9 d'utilisation pour l'op\u00e9rateur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avec des d\u00e9cennies d'exp\u00e9rience dans <strong>essais d'emballages de dispositifs m\u00e9dicaux et de produits pharmaceutiques<\/strong>Cell Instruments offre des solutions sur mesure pour :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Contr\u00f4le de la qualit\u00e9 des ampoules injectables<\/li>\n\n\n\n<li>Caract\u00e9risation des mat\u00e9riaux<\/li>\n\n\n\n<li>Des tests automatis\u00e9s sur mesure<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Si votre flux de travail pour le contr\u00f4le de la qualit\u00e9 implique des ampoules en verre, le BST-01 offre des performances in\u00e9gal\u00e9es en mati\u00e8re de contr\u00f4le de la qualit\u00e9. <strong>la pr\u00e9cision, la r\u00e9p\u00e9tabilit\u00e9 et la conformit\u00e9<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-cea0f97\" id=\"conclusion\" data-block-id=\"cea0f97\"><h2 class=\"stk-block-heading__text\">Conclusion<\/h2><\/div>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-08e63b8\" data-block-id=\"08e63b8\"><style>.stk-08e63b8{margin-bottom:0px !important}.stk-08e63b8 .stk-block-text__text{text-shadow:none !important}<\/style><p class=\"stk-block-text__text\">Garantir la r\u00e9sistance m\u00e9canique des ampoules est essentiel pour l'int\u00e9grit\u00e9 pharmaceutique et la s\u00e9curit\u00e9 des patients. En se conformant aux <a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>ISO 9187<\/strong> <\/a>et l'utilisation d'\u00e9quipements de pointe tels que le <strong>BST-01 Testeur de r\u00e9sistance m\u00e9canique des ampoules<\/strong>les fabricants peuvent v\u00e9rifier en toute confiance <strong>mesure de la force de rupture des ampoules de verre<\/strong>. Des tests pr\u00e9cis garantissent non seulement la qualit\u00e9 des produits, mais renforcent \u00e9galement la conformit\u00e9 aux r\u00e9glementations et la confiance des clients.<br>Pour les laboratoires et les fabricants \u00e0 la recherche de solutions d'essai fiables et conformes aux normes ISO, <strong>Cell Instruments' BST-01<\/strong> est un choix \u00e9prouv\u00e9 pour soutenir votre programme de test d'ampoules.<\/p><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Accurate evaluation of ampoule mechanical strength tester is critical in pharmaceutical quality control. Glass ampoules used for injectable solutions must be strong enough to maintain sterility during transportation and storage, yet easy enough to break open without excessive force. ISO 9187 provides standardized test procedures to assess these qualities, especially breaking force measurement for glass [&hellip;]<\/p>","protected":false},"author":1,"featured_media":2280,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2267","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"thumbnail":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp",150,150,true],"medium":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp",300,300,true],"medium_large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"1536x1536":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"2048x2048":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"trp-custom-language-flag":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",12,12,false]},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/fr\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Accurate evaluation of ampoule mechanical strength tester is critical in pharmaceutical quality control. Glass ampoules used for injectable solutions must be strong enough to maintain sterility during transportation and storage, yet easy enough to break open without excessive force. ISO 9187 provides standardized test procedures to assess these qualities, especially breaking force measurement for glass\u2026","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/comments?post=2267"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2267\/revisions"}],"predecessor-version":[{"id":2300,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2267\/revisions\/2300"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/media\/2280"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/media?parent=2267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/categories?post=2267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/tags?post=2267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}