{"id":2225,"date":"2025-07-17T03:26:50","date_gmt":"2025-07-17T03:26:50","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2225"},"modified":"2025-07-17T03:32:17","modified_gmt":"2025-07-17T03:32:17","slug":"break-loose-and-glide-force-testing","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/fr\/break-loose-and-glide-force-testing\/","title":{"rendered":"Essais de d\u00e9collement et de force de glissement pour le papier : ISO 7886 et \u00e9valuation des seringues"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2225\" class=\"elementor elementor-2225\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9145dad e-flex e-con-boxed e-con e-parent\" data-id=\"9145dad\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a89c638 elementor-widget elementor-widget-heading\" data-id=\"a89c638\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test de force de d\u00e9collement et de glissement : Un indicateur cl\u00e9 de la performance des seringues<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b6a1371 e-flex e-con-boxed e-con e-parent\" data-id=\"b6a1371\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-693eb6e elementor-widget elementor-widget-text-editor\" data-id=\"693eb6e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"538\" data-end=\"945\">Dans les secteurs des produits pharmaceutiques et des dispositifs m\u00e9dicaux, <strong data-start=\"591\" data-end=\"630\">essais de d\u00e9collement et de force de glissement<\/strong> est une proc\u00e9dure critique utilis\u00e9e pour \u00e9valuer la facilit\u00e9 d'utilisation et la qualit\u00e9 des seringues. Ces tests d\u00e9terminent la force n\u00e9cessaire pour d\u00e9marrer (se d\u00e9tacher) et poursuivre (glisser) le mouvement du piston \u00e0 l'int\u00e9rieur du corps de la seringue. Les r\u00e9sultats ont un impact direct sur la conformit\u00e9 du produit, le confort d'injection et la s\u00e9curit\u00e9 du patient.<\/p><p data-start=\"947\" data-end=\"1391\">Cette m\u00e9thode d'essai est particuli\u00e8rement importante pour les fabricants qui d\u00e9veloppent des <strong data-start=\"1016\" data-end=\"1091\">seringues pr\u00e9remplies, sous-ensembles st\u00e9riles et composants d'auto-injecteurs<\/strong>. Un piston trop serr\u00e9 ou trop l\u00e2che peut entra\u00eener des erreurs de dosage, le d\u00e9tachement du piston ou un \u00e9coulement irr\u00e9gulier du m\u00e9dicament, ce qui pr\u00e9sente des risques pour la s\u00e9curit\u00e9. C'est pourquoi le processus de test est clairement d\u00e9crit dans de nombreuses normes internationales, notamment <strong data-start=\"1341\" data-end=\"1355\">ISO 7886-1<\/strong>, <strong data-start=\"1357\" data-end=\"1372\">ISO 11040-4<\/strong>et <strong data-start=\"1378\" data-end=\"1390\">ISO 8537<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ee73ce6 e-flex e-con-boxed e-con e-parent\" data-id=\"ee73ce6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7316cbe elementor-widget elementor-widget-heading\" data-id=\"7316cbe\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test de la force de glissement de la seringue et normes de conformit\u00e9 internationales<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4fe64ba e-flex e-con-boxed e-con e-parent\" data-id=\"4fe64ba\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-697f2ea elementor-widget elementor-widget-text-editor\" data-id=\"697f2ea\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1470\" data-end=\"1745\">Les organismes de r\u00e9glementation ont \u00e9tabli des exigences strictes pour garantir la fiabilit\u00e9 et la reproductibilit\u00e9 des performances des seringues. <strong data-start=\"1585\" data-end=\"1616\">Test de la force de glissement de la seringue<\/strong> \u00e9value le comportement du frottement dans des conditions sp\u00e9cifiques, dans le but de d\u00e9tecter des variations dans la lubrification ou les propri\u00e9t\u00e9s des mat\u00e9riaux.<\/p><p data-start=\"1747\" data-end=\"2087\"><strong data-start=\"1747\" data-end=\"1761\">ISO 7886-1<\/strong><br data-start=\"1761\" data-end=\"1764\" \/>Cette norme s'applique <strong data-start=\"1789\" data-end=\"1820\">seringues st\u00e9riles \u00e0 usage unique<\/strong>. Elle d\u00e9finit des m\u00e9thodes de mesure de la force pour les valeurs de d\u00e9collement et de glissement, qui doivent rester dans des fourchettes pr\u00e9\u00e9tablies pour garantir un fonctionnement sans heurts. La vitesse d'essai g\u00e9n\u00e9ralement utilis\u00e9e est <strong data-start=\"2010\" data-end=\"2024\">100 mm\/min<\/strong>et l'acquisition de donn\u00e9es \u00e0 haute fr\u00e9quence (\u2265500 Hz) est recommand\u00e9e.<\/p><p data-start=\"2089\" data-end=\"2451\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"2089\" data-end=\"2104\">ISO 11040-4<\/strong><\/a><br data-start=\"2104\" data-end=\"2107\" \/>Ax\u00e9 sur <strong data-start=\"2118\" data-end=\"2158\">barils en verre pour seringues pr\u00e9-remplies<\/strong>Cette norme comprend <strong data-start=\"2183\" data-end=\"2194\">Annexe E<\/strong>qui sp\u00e9cifie la m\u00e9thode d'essai de la force de glissement pour les sous-ensembles st\u00e9riles. Il d\u00e9crit les exigences relatives \u00e0 la m\u00e9thode d'essai de la force de glissement pour les sous-ensembles st\u00e9riles. <strong data-start=\"2300\" data-end=\"2366\">bouchon de piston, int\u00e9rieur du baril et lubrification \u00e0 l'huile de silicone<\/strong>. Un frottement faible et constant est essentiel pour r\u00e9pondre aux crit\u00e8res d\u00e9finis dans la pr\u00e9sente norme.<\/p><p data-start=\"2453\" data-end=\"2717\"><strong data-start=\"2453\" data-end=\"2465\">ISO 8537<\/strong><br data-start=\"2465\" data-end=\"2468\" \/>Con\u00e7u pour <strong data-start=\"2481\" data-end=\"2501\">seringues d'insuline<\/strong>Cette norme met l'accent sur la pr\u00e9cision de l'administration de la dose gr\u00e2ce au contr\u00f4le du mouvement du piston. La r\u00e9sistance au glissement est particuli\u00e8rement importante dans les dispositifs d'administration d'insuline, o\u00f9 un taux d'injection r\u00e9gulier garantit une gestion s\u00fbre du glucose.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f96e75b e-flex e-con-boxed e-con e-parent\" data-id=\"f96e75b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab96e67 elementor-widget elementor-widget-heading\" data-id=\"ab96e67\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Proc\u00e9dures et param\u00e8tres d'essai<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e898377 e-flex e-con-boxed e-con e-parent\" data-id=\"e898377\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6c4a14 elementor-widget elementor-widget-text-editor\" data-id=\"e6c4a14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2760\" data-end=\"2842\">La proc\u00e9dure d'essai de d\u00e9collement et de force de glissement suit un format structur\u00e9 :<\/p><ol data-start=\"2844\" data-end=\"3739\"><li data-start=\"2844\" data-end=\"2990\"><p data-start=\"2847\" data-end=\"2990\"><strong data-start=\"2847\" data-end=\"2862\">Pr\u00e9paration<\/strong><br data-start=\"2862\" data-end=\"2865\" \/>Utilisation <strong data-start=\"2872\" data-end=\"2901\">seringues vides st\u00e9rilis\u00e9es<\/strong> pr\u00eat \u00e0 \u00eatre rempli. Installer un bouchon de piston compatible avec des niveaux de lubrification d\u00e9finis.<\/p><\/li><li data-start=\"2992\" data-end=\"3220\"><p data-start=\"2995\" data-end=\"3220\"><strong data-start=\"2995\" data-end=\"3004\">Mise en place<\/strong><br data-start=\"3004\" data-end=\"3007\" \/>Placez la seringue dans une machine d'essai universelle ou dans un \u00e9quipement sp\u00e9cialis\u00e9 tel que la machine de contr\u00f4le de la qualit\u00e9 de l'eau. <strong data-start=\"3094\" data-end=\"3155\">Cell Instruments SSR-01 Testeur de r\u00e9sistance au glissement des seringues<\/strong>. Fixez-le en alignant correctement le dispositif de fixation afin de garantir un mouvement axial.<\/p><\/li><li data-start=\"3222\" data-end=\"3419\"><p data-start=\"3225\" data-end=\"3419\"><strong data-start=\"3225\" data-end=\"3238\">Ex\u00e9cution<\/strong><br data-start=\"3238\" data-end=\"3241\" \/>D\u00e9clencher le mouvement du piston \u00e0 100 mm\/min. L'\u00e9quipement d'essai enregistre la <strong data-start=\"3319\" data-end=\"3355\">force de d\u00e9collement (pic initial)<\/strong> et le <strong data-start=\"3364\" data-end=\"3418\">force de glissement (force moyenne lors d'un mouvement continu)<\/strong>.<\/p><\/li><li data-start=\"3421\" data-end=\"3597\"><p data-start=\"3424\" data-end=\"3472\"><strong data-start=\"3424\" data-end=\"3440\">Capture des donn\u00e9es<\/strong><br data-start=\"3440\" data-end=\"3443\" \/>Enregistrer les donn\u00e9es cl\u00e9s, notamment<\/p><ul data-start=\"3476\" data-end=\"3597\"><li data-start=\"3476\" data-end=\"3500\"><p data-start=\"3478\" data-end=\"3500\">Force de d\u00e9collement (f\u2080)<\/p><\/li><li data-start=\"3504\" data-end=\"3526\"><p data-start=\"3506\" data-end=\"3526\">Force de glissement moyenne (F)<\/p><\/li><li data-start=\"3530\" data-end=\"3558\"><p data-start=\"3532\" data-end=\"3558\">Force de glissement maximale (F\u2098\u2090\u2093)<\/p><\/li><li data-start=\"3562\" data-end=\"3597\"><p data-start=\"3564\" data-end=\"3597\">Distance de d\u00e9placement et dur\u00e9e du test<\/p><\/li><\/ul><\/li><li data-start=\"3599\" data-end=\"3739\"><p data-start=\"3602\" data-end=\"3739\"><strong data-start=\"3602\" data-end=\"3616\">L'\u00e9valuation<\/strong><br data-start=\"3616\" data-end=\"3619\" \/>Les r\u00e9sultats sont compar\u00e9s aux limites de sp\u00e9cification des normes ISO 7886-1, ISO 11040-4 ou ISO 8537, selon le type de seringue.<\/p><\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94fd533 e-flex e-con-boxed e-con e-parent\" data-id=\"94fd533\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f724e30 elementor-widget elementor-widget-heading\" data-id=\"f724e30\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Probl\u00e8mes courants d\u00e9tect\u00e9s lors des tests de la force de glisse<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-422d4c4 e-flex e-con-boxed e-con e-parent\" data-id=\"422d4c4\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbff8ed elementor-widget elementor-widget-text-editor\" data-id=\"dbff8ed\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3802\" data-end=\"3888\">Les tests de d\u00e9collement et de force de glissement r\u00e9v\u00e8lent des probl\u00e8mes critiques de qualit\u00e9 des seringues, tels que<\/p><ul data-start=\"3890\" data-end=\"4134\"><li data-start=\"3890\" data-end=\"3961\"><p data-start=\"3892\" data-end=\"3961\"><strong data-start=\"3892\" data-end=\"3914\">Frottement excessif<\/strong> d'une couche de silicone insuffisante ou irr\u00e9guli\u00e8re<\/p><\/li><li data-start=\"3962\" data-end=\"4012\"><p data-start=\"3964\" data-end=\"4012\"><strong data-start=\"3964\" data-end=\"3985\">Plongeurs coll\u00e9s<\/strong>La pr\u00e9cision de la dose est affect\u00e9e par l'utilisation d'un syst\u00e8me d'alimentation en eau.<\/p><\/li><li data-start=\"4013\" data-end=\"4072\"><p data-start=\"4015\" data-end=\"4072\"><strong data-start=\"4015\" data-end=\"4043\">Incompatibilit\u00e9 des mat\u00e9riaux<\/strong> entre le canon et le plongeur<\/p><\/li><li data-start=\"4073\" data-end=\"4134\"><p data-start=\"4075\" data-end=\"4134\"><strong data-start=\"4075\" data-end=\"4100\">D\u00e9connexion du piston<\/strong> ou fuite du joint sous l'effet de la force axiale<\/p><\/li><\/ul><p data-start=\"4136\" data-end=\"4237\">L'identification de ces probl\u00e8mes au cours de la R&amp;D ou de la production prot\u00e8ge les processus en aval et les r\u00e9sultats pour les patients.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-358cd95 e-flex e-con-boxed e-con e-parent\" data-id=\"358cd95\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1be87be elementor-widget elementor-widget-heading\" data-id=\"1be87be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Equipement recommand\u00e9 : Cell Instruments SSR-01 Testeur de r\u00e9sistance au glissement des seringues<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-97d0577 e-flex e-con-boxed e-con e-parent\" data-id=\"97d0577\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4f6c718 e-con-full e-flex e-con e-child\" data-id=\"4f6c718\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-495d6e6 elementor-widget elementor-widget-text-editor\" data-id=\"495d6e6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4330\" data-end=\"4474\">Pour ex\u00e9cuter ces tests avec pr\u00e9cision et en conformit\u00e9 avec les normes ISO, Cell Instruments propose les produits suivants<a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/syringes-plunger-glide-force-tester\/\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"4430\" data-end=\"4440\">SSR-01<\/strong><\/a>. Cet instrument est con\u00e7u pour :<\/p><ul data-start=\"4476\" data-end=\"4766\"><li data-start=\"4476\" data-end=\"4534\"><p data-start=\"4478\" data-end=\"4534\"><strong data-start=\"4478\" data-end=\"4501\">Une mesure pr\u00e9cise<\/strong> de la force de rupture et de la force de glissement<\/p><\/li><li data-start=\"4535\" data-end=\"4596\"><p data-start=\"4537\" data-end=\"4596\"><strong data-start=\"4537\" data-end=\"4563\">Vitesses de test r\u00e9glables<\/strong> et des param\u00e8tres de test programmables<\/p><\/li><li data-start=\"4597\" data-end=\"4657\"><p data-start=\"4599\" data-end=\"4657\"><strong data-start=\"4599\" data-end=\"4625\">Affichage des donn\u00e9es en temps r\u00e9el<\/strong> via un \u00e9cran tactile HMI de 7 pouces<\/p><\/li><li data-start=\"4658\" data-end=\"4712\"><p data-start=\"4660\" data-end=\"4712\"><strong data-start=\"4660\" data-end=\"4686\">Micro-imprimante int\u00e9gr\u00e9e<\/strong> pour rapport imm\u00e9diat<\/p><\/li><li data-start=\"4713\" data-end=\"4766\"><p data-start=\"4715\" data-end=\"4766\"><strong data-start=\"4715\" data-end=\"4736\">Appareils flexibles<\/strong> pour diff\u00e9rents formats de seringues<\/p><\/li><\/ul><p data-start=\"4768\" data-end=\"4893\">Son interface intuitive et ses performances robustes en font un outil id\u00e9al \u00e0 la fois pour <strong data-start=\"4838\" data-end=\"4859\">l'assurance qualit\u00e9<\/strong> et <strong data-start=\"4864\" data-end=\"4892\">laboratoires de d\u00e9veloppement de produits<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7285d35 e-con-full e-flex e-con e-child\" data-id=\"7285d35\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f5e0678 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"f5e0678\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp\" class=\"attachment-medium_large size-medium_large wp-image-2227\" alt=\"la machine d&#039;essai de force de d\u00e9collement et de glissement - une solution polyvalente et de haute pr\u00e9cision con\u00e7ue pour les essais de seringues et de mat\u00e9riaux d&#039;emballage.\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-768x768.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-1024x1024.webp 1024w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/1.Break-and-guide-force-testing-machine-1_11zon-1.webp 1080w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d9ef370 e-flex e-con-boxed e-con e-parent\" data-id=\"d9ef370\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-354bdaf elementor-widget elementor-widget-heading\" data-id=\"354bdaf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">L'importance de ces tests pour les fabricants<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9e66002 e-flex e-con-boxed e-con e-parent\" data-id=\"9e66002\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-aae1c87 e-con-full e-flex e-con e-child\" data-id=\"aae1c87\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf49733 elementor-widget elementor-widget-video\" data-id=\"bf49733\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=Jv55XhLaURk&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;modestbranding&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2cf2943 e-con-full e-flex e-con e-child\" data-id=\"2cf2943\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c0dc11 elementor-widget elementor-widget-text-editor\" data-id=\"0c0dc11\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"4948\" data-end=\"5007\"><p data-start=\"4950\" data-end=\"5007\"><strong data-start=\"4950\" data-end=\"4981\">Appuie les d\u00e9p\u00f4ts r\u00e9glementaires<\/strong> avec des donn\u00e9es conformes \u00e0 la norme ISO<\/p><\/li><li data-start=\"5008\" data-end=\"5082\"><p data-start=\"5010\" data-end=\"5082\"><strong data-start=\"5010\" data-end=\"5040\">Am\u00e9liore la facilit\u00e9 d'utilisation du produit<\/strong> en \u00e9liminant les blocages ou les d\u00e9bits irr\u00e9guliers<\/p><\/li><li data-start=\"5083\" data-end=\"5144\"><p data-start=\"5085\" data-end=\"5144\"><strong data-start=\"5085\" data-end=\"5115\">Augmente l'uniformit\u00e9 des lots<\/strong> pour la production en grande s\u00e9rie<\/p><\/li><li data-start=\"5145\" data-end=\"5201\"><p data-start=\"5147\" data-end=\"5201\"><strong data-start=\"5147\" data-end=\"5173\">R\u00e9duction du risque de rappel<\/strong> en raison d'une d\u00e9faillance m\u00e9canique<\/p><\/li><li data-start=\"5202\" data-end=\"5283\"><p data-start=\"5204\" data-end=\"5283\"><strong data-start=\"5204\" data-end=\"5232\">Am\u00e9liore le confort du patient<\/strong>sp\u00e9cialement pour les auto-injecteurs et les seringues d'insuline<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0c0191b e-flex e-con-boxed e-con e-parent\" data-id=\"0c0191b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4180a60 elementor-widget elementor-widget-heading\" data-id=\"4180a60\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fa9b8b6 e-flex e-con-boxed e-con e-parent\" data-id=\"fa9b8b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-28ecdb2 elementor-widget elementor-widget-text-editor\" data-id=\"28ecdb2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5306\" data-end=\"5729\"><strong data-start=\"5306\" data-end=\"5345\">Test de d\u00e9collement et de force de glissement<\/strong> est un \u00e9l\u00e9ment fondamental de l'\u00e9valuation de la qualit\u00e9 des seringues. Le respect des <a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5411\" data-end=\"5425\">ISO 7886-1<\/strong><\/a>, <strong data-start=\"5427\" data-end=\"5442\">ISO 11040-4<\/strong>et <strong data-start=\"5448\" data-end=\"5460\">ISO 8537<\/strong> garantit la fiabilit\u00e9 des produits, la conformit\u00e9 aux r\u00e9glementations et la s\u00e9curit\u00e9 de l'administration des m\u00e9dicaments. En investissant dans des instruments de pointe tels que le <strong data-start=\"5583\" data-end=\"5615\">SSR-01 de<a href=\"https:\/\/www.celtec.cn\" target=\"_blank\" rel=\"noopener\"> Instruments cellulaires<\/a><\/strong>Les fabricants peuvent donc en toute confiance fournir des seringues tr\u00e8s performantes qui r\u00e9pondent aux attentes de l'industrie et des patients.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Test de d\u00e9collement et de force de glissement : Un indicateur cl\u00e9 de la performance des seringues Dans les industries pharmaceutiques et des dispositifs m\u00e9dicaux, les tests de force de d\u00e9collement et de glissement sont une proc\u00e9dure critique utilis\u00e9e pour \u00e9valuer la facilit\u00e9 d'utilisation et la qualit\u00e9 des seringues. Ces tests d\u00e9terminent la force n\u00e9cessaire pour amorcer (d\u00e9tachement) et poursuivre (glissement) le mouvement [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2225","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/fr\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Break Loose and Glide Force Testing: A Key Indicator of Syringe Performance In the pharmaceutical and medical device industries, break loose and glide force testing is a critical procedure used to evaluate the usability and quality of syringes. These tests determine how much force is required to start (break loose) and continue (glide) the movement\u2026","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2225","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/comments?post=2225"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2225\/revisions"}],"predecessor-version":[{"id":2251,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2225\/revisions\/2251"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/media?parent=2225"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/categories?post=2225"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/tags?post=2225"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}