{"id":2197,"date":"2025-06-24T02:14:04","date_gmt":"2025-06-24T02:14:04","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2197"},"modified":"2025-06-24T02:18:12","modified_gmt":"2025-06-24T02:18:12","slug":"iso-7864","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/fr\/iso-7864\/","title":{"rendered":"ISO 7864 Test de fonctionnalit\u00e9 des seringues hypodermiques"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2197\" class=\"elementor elementor-2197\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-66b560c e-flex e-con-boxed e-con e-parent\" data-id=\"66b560c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-86c40f3 elementor-widget elementor-widget-heading\" data-id=\"86c40f3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 7864 <br><small><small>Test de fonctionnalit\u00e9 des seringues hypodermiques<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b5014aa e-con-full e-flex e-con e-child\" data-id=\"b5014aa\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dea855d elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"dea855d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"398\" data-end=\"1099\">Lorsqu'il s'agit d'aiguilles hypodermiques st\u00e9riles, la s\u00e9curit\u00e9 du patient et la performance du produit ne sont pas n\u00e9gociables. C'est pourquoi <strong data-start=\"534\" data-end=\"546\">ISO 7864<\/strong> joue un r\u00f4le essentiel. Cette norme internationale d\u00e9finit des exigences et des m\u00e9thodes d'essai compl\u00e8tes pour \u00e9valuer les aiguilles hypodermiques en fonction des crit\u00e8res suivants <strong data-start=\"683\" data-end=\"706\">seringues \u00e0 usage unique<\/strong>, y compris <strong data-start=\"718\" data-end=\"751\">test de fonctionnalit\u00e9 de la seringue<\/strong>, <strong data-start=\"753\" data-end=\"787\">m\u00e9thode d'essai de p\u00e9n\u00e9tration de l'aiguille<\/strong>et <strong data-start=\"793\" data-end=\"820\">force de la liaison de l'aiguille<\/strong>. Les fabricants, les ing\u00e9nieurs charg\u00e9s du contr\u00f4le de la qualit\u00e9 et les organismes de r\u00e9glementation s'appuient sur la norme ISO 7864 pour garantir une qualit\u00e9 et une s\u00e9curit\u00e9 constantes des produits.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f53d82 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"7f53d82\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/syringe-needle-penetration-test\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1.webp\" class=\"attachment-full size-full wp-image-2200\" alt=\"ISO 7864 Test de fonctionnalit\u00e9 des seringues hypodermiques\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1-300x200.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11bf196 elementor-widget elementor-widget-heading\" data-id=\"11bf196\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Qu'est-ce que la norme ISO 7864 et pourquoi est-elle importante ?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edf0ed0 elementor-widget elementor-widget-text-editor\" data-id=\"edf0ed0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1422\"><strong data-start=\"1148\" data-end=\"1160\">ISO 7864<\/strong> est le <strong data-start=\"1168\" data-end=\"1225\">Norme internationale pour les aiguilles hypodermiques st\u00e9riles<\/strong> destin\u00e9e \u00e0 un usage unique avec des seringues ou du mat\u00e9riel de perfusion. Elle d\u00e9finit les exigences physiques de l'aiguille, ses dimensions, ses caract\u00e9ristiques de performance, son conditionnement et sa dur\u00e9e de vie. <strong data-start=\"1390\" data-end=\"1406\">m\u00e9thodes d'essai<\/strong> pour l'\u00e9valuation :<\/p><ul><li data-start=\"1426\" data-end=\"1445\"><strong data-start=\"1426\" data-end=\"1443\">P\u00e9n\u00e9trabilit\u00e9<\/strong><\/li><li data-start=\"1448\" data-end=\"1470\"><strong data-start=\"1448\" data-end=\"1468\">Force d'adh\u00e9rence<\/strong><\/li><li data-start=\"1473\" data-end=\"1500\"><strong data-start=\"1473\" data-end=\"1498\">Int\u00e9grit\u00e9 du tube de l'aiguille<\/strong><\/li><li data-start=\"1503\" data-end=\"1529\"><strong data-start=\"1503\" data-end=\"1527\">R\u00e9sistance \u00e0 la corrosion<\/strong><\/li><li data-start=\"1532\" data-end=\"1557\"><strong data-start=\"1532\" data-end=\"1557\">Compatibilit\u00e9 des seringues<\/strong><\/li><\/ul><p data-start=\"1559\" data-end=\"1707\">La conformit\u00e9 \u00e0 la norme ISO 7864 garantit que les aiguilles fonctionnent de mani\u00e8re fiable dans des conditions cliniques, r\u00e9duisant ainsi les risques pour les patients et les prestataires de soins de sant\u00e9.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f659161 elementor-widget elementor-widget-heading\" data-id=\"f659161\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test de fonctionnalit\u00e9 des seringues ISO<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1eb6db elementor-widget elementor-widget-text-editor\" data-id=\"c1eb6db\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1714\" data-end=\"1946\"><strong data-start=\"1782\" data-end=\"1815\">Test de fonctionnalit\u00e9 de la seringue<\/strong> garantit que l'aiguille est compatible avec la seringue \u00e0 laquelle elle est destin\u00e9e et qu'elle fonctionne efficacement pendant l'injection. Les param\u00e8tres test\u00e9s sont les suivants<\/p><ul><li data-start=\"1950\" data-end=\"1990\"><strong data-start=\"1950\" data-end=\"1988\">Compatibilit\u00e9 avec les connecteurs Luer<\/strong><\/li><li data-start=\"1993\" data-end=\"2012\"><strong data-start=\"1993\" data-end=\"2010\">Force du piston<\/strong><\/li><li data-start=\"2015\" data-end=\"2048\"><strong data-start=\"2015\" data-end=\"2046\">Consistance de la force d'injection<\/strong><\/li><li data-start=\"2051\" data-end=\"2078\"><strong data-start=\"2051\" data-end=\"2078\">R\u00e9duction de l'espace mort<\/strong><\/li><\/ul><p data-start=\"2080\" data-end=\"2309\">Ces \u00e9valuations sont essentielles pour une <strong data-start=\"2118\" data-end=\"2133\">Seringue ISO<\/strong> pour obtenir la certification. Cell Instruments propose des solutions qui \u00e9valuent la fonctionnalit\u00e9 en mesurant la force d'insertion, la r\u00e9sistance du piston et la distribution de la force pendant l'injection.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64b918a elementor-widget elementor-widget-heading\" data-id=\"64b918a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test de p\u00e9n\u00e9trabilit\u00e9 de l'aiguille<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7baacfb elementor-widget elementor-widget-text-editor\" data-id=\"7baacfb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2316\" data-end=\"2506\">L'un des tests les plus importants de la norme ISO 7864 est le <strong data-start=\"2429\" data-end=\"2463\">m\u00e9thode d'essai de p\u00e9n\u00e9tration de l'aiguille<\/strong>, \u00e9galement connu sous le nom de <strong data-start=\"2483\" data-end=\"2505\">test de p\u00e9n\u00e9trabilit\u00e9<\/strong>.<\/p><p data-start=\"2508\" data-end=\"2747\"><strong data-start=\"2508\" data-end=\"2526\">Principe du test<\/strong><br data-start=\"2526\" data-end=\"2529\" \/>Une aiguille est ins\u00e9r\u00e9e dans un tube standardis\u00e9. <strong data-start=\"2570\" data-end=\"2583\">substrat<\/strong> \u00e0 une vitesse constante (typiquement 100 mm\/min). Les <strong data-start=\"2632\" data-end=\"2658\">force de p\u00e9n\u00e9tration maximale<\/strong> et <strong data-start=\"2663\" data-end=\"2677\">force de tra\u00een\u00e9e<\/strong> sont enregistr\u00e9es afin d'\u00e9valuer la facilit\u00e9 de p\u00e9n\u00e9tration et la coh\u00e9rence du mouvement.<\/p><p data-start=\"2749\" data-end=\"2768\"><strong data-start=\"2749\" data-end=\"2766\">\u00c9quipements cl\u00e9s<\/strong><\/p><ul><li data-start=\"2771\" data-end=\"2826\">Syst\u00e8me de mesure de la force avec pr\u00e9cision <strong data-start=\"2811\" data-end=\"2824\">cellule de charge<\/strong><\/li><li data-start=\"2829\" data-end=\"2865\">Porte-aiguille avec alignement axial<\/li><li data-start=\"2868\" data-end=\"2918\">Substrat valid\u00e9 (par exemple, caoutchouc latex ou LDPE)<\/li><li data-start=\"2921\" data-end=\"2979\">Jauge de profondeur de p\u00e9n\u00e9tration (typiquement 80% de la longueur de l'aiguille)<\/li><\/ul><p data-start=\"2981\" data-end=\"3175\"><strong data-start=\"2981\" data-end=\"3001\">Instruments cellulaires<\/strong> offres <strong data-start=\"3009\" data-end=\"3049\">testeur de p\u00e9n\u00e9tration automatis\u00e9 \u00e0 aiguille<\/strong>\u00a0avec des vitesses programmables et une analyse num\u00e9rique de la force pour garantir la pr\u00e9cision et la r\u00e9p\u00e9tabilit\u00e9 conform\u00e9ment \u00e0 l'annexe D de la norme ISO 7864.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46d372b elementor-widget elementor-widget-heading\" data-id=\"46d372b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Force de tra\u00een\u00e9e et force de p\u00e9n\u00e9tration maximale<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b565e71 elementor-widget elementor-widget-text-editor\" data-id=\"b565e71\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3182\" data-end=\"3269\">Deux r\u00e9sultats principaux en d\u00e9coulent :<\/p><ul><li data-start=\"3273\" data-end=\"3345\"><strong data-start=\"3273\" data-end=\"3300\">Force de p\u00e9n\u00e9tration maximale :<\/strong> Force maximale requise pour percer le substrat<\/li><li data-start=\"3348\" data-end=\"3436\"><strong data-start=\"3348\" data-end=\"3363\">Force de tra\u00een\u00e9e :<\/strong> Force moyenne n\u00e9cessaire pour maintenir la p\u00e9n\u00e9tration sur 80% de la longueur de l'aiguille<\/li><\/ul><p data-start=\"3438\" data-end=\"3600\">Ces mesures refl\u00e8tent le tranchant de l'aiguille, la friction et l'homog\u00e9n\u00e9it\u00e9 de la fabrication. Pour les soumissions r\u00e9glementaires et la validation de la conception, une mesure pr\u00e9cise est cruciale.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c892b5 elementor-widget elementor-widget-heading\" data-id=\"5c892b5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Force de l'essai d'adh\u00e9rence de l'aiguille<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30d6b5b elementor-widget elementor-widget-text-editor\" data-id=\"30d6b5b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3607\" data-end=\"3825\">La force d'adh\u00e9rence fait r\u00e9f\u00e9rence \u00e0 la <strong data-start=\"3697\" data-end=\"3745\">l'adh\u00e9rence entre le tube de l'aiguille et le moyeu<\/strong>-une liaison faible peut entra\u00eener un d\u00e9tachement lors de l'injection, ce qui constitue un risque grave.<\/p><p data-start=\"3827\" data-end=\"3870\"><strong data-start=\"3827\" data-end=\"3868\">Proc\u00e9dure d'essai (ISO 7864 Annexe E) :<\/strong><\/p><ul><li data-start=\"3873\" data-end=\"3938\">L'aiguille est saisie verticalement sur un <strong data-start=\"3907\" data-end=\"3936\">machine d'essai universelle<\/strong><\/li><li data-start=\"3941\" data-end=\"3986\">A <strong data-start=\"3943\" data-end=\"3960\">force de traction<\/strong> est appliqu\u00e9 \u00e0 une vitesse de 50 mm\/min<\/li><li data-start=\"3989\" data-end=\"4062\">Le <strong data-start=\"3993\" data-end=\"4010\">force maximale<\/strong> \u00e0 laquelle se produit le d\u00e9tachement ou la d\u00e9faillance est enregistr\u00e9e<\/li><\/ul><p data-start=\"4064\" data-end=\"4223\"><strong data-start=\"4064\" data-end=\"4084\">Instruments cellulaires<\/strong> fournit <strong data-start=\"4094\" data-end=\"4123\">testeur de traction universel<\/strong>\u00a0avec des accessoires sur mesure pour les <strong data-start=\"4153\" data-end=\"4177\">test de collage d'aiguille<\/strong>Il s'agit de veiller au respect des proc\u00e9dures de l'annexe E.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94ab6f1 elementor-widget elementor-widget-heading\" data-id=\"94ab6f1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conformit\u00e9 des instruments cellulaires \u00e0 la norme ISO 7864 <\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-603c5c9 elementor-widget elementor-widget-text-editor\" data-id=\"603c5c9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4230\" data-end=\"4393\">Cell Instruments est sp\u00e9cialis\u00e9 dans <strong data-start=\"4318\" data-end=\"4349\">solutions d'essai de pr\u00e9cision<\/strong> pour les fabricants de dispositifs m\u00e9dicaux :<\/p><ul><li data-start=\"4397\" data-end=\"4427\">Testeur de p\u00e9n\u00e9trabilit\u00e9 de l'aiguille<\/li><li data-start=\"4430\" data-end=\"4463\">Testeur universel de force d'adh\u00e9rence<\/li><li data-start=\"4466\" data-end=\"4505\">Syst\u00e8mes de test de fonctionnalit\u00e9 des seringues<\/li><li data-start=\"4508\" data-end=\"4576\">Fixations personnalis\u00e9es pour la compatibilit\u00e9 Luer lock et le maintien de l'aiguille<\/li><li data-start=\"4579\" data-end=\"4637\">Am\u00e9lioration de l'automatisation pour <strong data-start=\"4603\" data-end=\"4635\">la r\u00e9p\u00e9tabilit\u00e9 et le rendement<\/strong><\/li><\/ul><p data-start=\"4639\" data-end=\"4842\">Tous les instruments sont con\u00e7us pour s'aligner sur les <strong data-start=\"4679\" data-end=\"4691\">ISO 7864<\/strong>, <strong data-start=\"4693\" data-end=\"4705\">ISO 8537<\/strong>, <a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"4707\" data-end=\"4719\">ISO 7886<\/strong><\/a>et <strong data-start=\"4725\" data-end=\"4736\">USP 381<\/strong> normes. Nos syst\u00e8mes prennent en charge l'analyse statistique, l'exportation des donn\u00e9es et les certificats d'\u00e9talonnage tra\u00e7ables.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0546b7e elementor-widget elementor-widget-heading\" data-id=\"0546b7e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3b149b elementor-widget elementor-widget-toggle\" data-id=\"f3b149b\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2551\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2551\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">1. Qu'est-ce que l'ISO 7864 ?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2551\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2551\"><p data-start=\"5830\" data-end=\"6017\"><a href=\"https:\/\/www.iso.org\/standard\/60481.html\" target=\"_blank\" rel=\"noopener\">ISO 7864<\/a> sp\u00e9cifie les exigences et les m\u00e9thodes d'essai pour les aiguilles hypodermiques st\u00e9riles \u00e0 usage unique. Elle couvre les dimensions physiques, les mat\u00e9riaux et les tests de performance.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2552\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2552\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">2. En quoi consiste le test de fonctionnalit\u00e9 de la seringue ?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2552\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2552\"><p data-start=\"6019\" data-end=\"6226\">Il \u00e9value l'interaction entre la seringue et l'aiguille, y compris la force d'injection, l'\u00e9tanch\u00e9it\u00e9 et la facilit\u00e9 d'utilisation afin de garantir un fonctionnement coh\u00e9rent et s\u00fbr.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2553\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2553\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">3. Comment le test de p\u00e9n\u00e9trabilit\u00e9 est-il effectu\u00e9 ?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2553\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2553\"><p data-start=\"6228\" data-end=\"6415\">Une aiguille est ins\u00e9r\u00e9e dans un mat\u00e9riau normalis\u00e9 \u00e0 une vitesse de 100 mm\/min. Les forces de pointe et de tra\u00een\u00e9e sont enregistr\u00e9es pour \u00e9valuer l'acuit\u00e9 et la performance de l'aiguille.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2554\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2554\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">4. Qu'est-ce qui est mesur\u00e9 dans le test de la force de collage de l'aiguille ?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2554\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2554\"><p data-start=\"6417\" data-end=\"6591\">La force de traction n\u00e9cessaire pour d\u00e9tacher l'aiguille du moyeu. Elle permet de v\u00e9rifier l'int\u00e9grit\u00e9 m\u00e9canique sous contrainte.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2555\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2555\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">5. Quels instruments peuvent contribuer \u00e0 la conformit\u00e9 \u00e0 la norme ISO 7864 ?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2555\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2555\"><p data-start=\"6593\" data-end=\"6806\">Le syst\u00e8me automatis\u00e9 de Cell Instruments\u00a0<strong data-start=\"6683\" data-end=\"6708\">testeur de p\u00e9n\u00e9trabilit\u00e9<\/strong>\u00a0et\u00a0<strong data-start=\"6713\" data-end=\"6742\">testeur de traction universel<\/strong>\u00a0sont id\u00e9ales pour l'\u00e9valuation des aiguilles et des seringues conform\u00e9ment \u00e0 la norme ISO 7864.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7864 Test de fonctionnalit\u00e9 des seringues hypodermiques Lorsqu'il s'agit d'aiguilles hypodermiques st\u00e9riles, la s\u00e9curit\u00e9 du patient et la performance du produit ne sont pas n\u00e9gociables. C'est l\u00e0 que la norme ISO 7864 joue un r\u00f4le essentiel. Cette norme internationale d\u00e9finit des exigences et des m\u00e9thodes d'essai compl\u00e8tes pour \u00e9valuer les aiguilles hypodermiques pour les seringues \u00e0 usage unique, y compris l'essai de fonctionnalit\u00e9 de la seringue, la m\u00e9thode d'essai de p\u00e9n\u00e9tration de l'aiguille et la force de [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[93,92],"class_list":["post-2197","post","type-post","status-publish","format-standard","hentry","category-blog","tag-iso-7864","tag-standards"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/fr\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 7864 Hypodermic Syringe Functionality Testing When it comes to sterile hypodermic needles, patient safety and product performance are non-negotiable. That\u2019s where ISO 7864 plays a vital role. This international standard outlines comprehensive requirements and test methods to evaluate hypodermic needles for single-use syringes, including syringe functionality testing, needle penetration test method, and strength of\u2026","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2197","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/comments?post=2197"}],"version-history":[{"count":4,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2197\/revisions"}],"predecessor-version":[{"id":2203,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2197\/revisions\/2203"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/media?parent=2197"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/categories?post=2197"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/tags?post=2197"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}