{"id":2139,"date":"2025-06-03T08:40:20","date_gmt":"2025-06-03T08:40:20","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2139"},"modified":"2026-01-13T07:49:16","modified_gmt":"2026-01-13T07:49:16","slug":"hypodermic-needle-sharpness-testing","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/fr\/hypodermic-needle-sharpness-testing\/","title":{"rendered":"Test d'acuit\u00e9 des aiguilles hypodermiques"},"content":{"rendered":"<h1 class=\"wp-block-heading has-text-align-center\">ISO 7864 Test d'acuit\u00e9 des aiguilles hypodermiques<\/h1>\n\n\n\n<div class=\"wp-block-stackable-columns stk-block-columns stk-block stk-3e28f64\" data-block-id=\"3e28f64\"><div class=\"stk-row stk-inner-blocks stk-block-content stk-content-align stk-3e28f64-column\">\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-52adcfa\" data-v=\"4\" data-block-id=\"52adcfa\"><style>@media screen and (min-width:768px){.stk-52adcfa{flex:1 1 calc(70.6% - var(--stk-column-gap,0px) * 1 \/ 2 ) !important}}<\/style><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-52adcfa-container stk--no-background stk--no-padding\"><div class=\"stk-block-content stk-inner-blocks stk-52adcfa-inner-blocks\">\n<h2 class=\"wp-block-heading\">Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Test d'acuit\u00e9 de l'aiguille<\/strong> est essentiel pour \u00e9valuer les aiguilles hypodermiques et s'assurer qu'elles r\u00e9pondent aux normes de s\u00e9curit\u00e9 et de performance lors de leur utilisation m\u00e9dicale. Guid\u00e9e par <strong>ISO 7864<\/strong>Le test de l'aiguille permet d'\u00e9valuer les param\u00e8tres critiques de l'aiguille afin de confirmer sa conformit\u00e9 et d'\u00e9viter toute douleur ou l\u00e9sion tissulaire inutile lors de l'injection. Dans cet article, nous verrons comment r\u00e9aliser un <strong>test d'acuit\u00e9 de l'aiguille<\/strong> y compris les meilleures pratiques en mati\u00e8re de <strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/fr\/syringe-needle-penetration-test\/\" target=\"_blank\" rel=\"noreferrer noopener\">test de p\u00e9n\u00e9tration \u00e0 l'aiguille<\/a><\/strong> et <strong>test des aiguilles hypodermiques<\/strong> pour r\u00e9pondre aux exigences de la norme ISO 7864.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Comprendre l'importance du test d'acuit\u00e9 de l'aiguille<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les aiguilles pointues sont essentielles dans les applications m\u00e9dicales pour garantir un minimum d'inconfort, une r\u00e9duction des l\u00e9sions tissulaires et une administration efficace des m\u00e9dicaments. <strong>Test d'acuit\u00e9 de l'aiguille<\/strong> \u00e9value la capacit\u00e9 d'une aiguille \u00e0 p\u00e9n\u00e9trer divers substrats avec une force minimale, en mesurant \u00e0 la fois les pics de p\u00e9n\u00e9tration et les forces de tra\u00een\u00e9e. En garantissant la conformit\u00e9 \u00e0 la norme ISO 7864, les fabricants peuvent fournir des dispositifs m\u00e9dicaux s\u00fbrs et fiables, contribuant ainsi au confort et \u00e0 la s\u00e9curit\u00e9 des patients.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-stackable-column stk-block-column stk-column stk-block stk-070da0f\" data-v=\"4\" data-block-id=\"070da0f\"><style>@media screen and (min-width:768px){.stk-070da0f{flex:1 1 calc(29.4% - var(--stk-column-gap,0px) * 1 \/ 2 ) !important}}<\/style><div class=\"stk-column-wrapper stk-block-column__content stk-container stk-070da0f-container stk--no-background stk--no-padding\"><div class=\"has-text-align-center stk-block-content stk-inner-blocks stk-070da0f-inner-blocks\">\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"519\" height=\"924\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/Hypodermic-Needle-Sharpness-Testing-ISO-7864.webp\" alt=\"\" class=\"wp-image-2141\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/Hypodermic-Needle-Sharpness-Testing-ISO-7864.webp 519w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/Hypodermic-Needle-Sharpness-Testing-ISO-7864-169x300.webp 169w\" sizes=\"(max-width: 519px) 100vw, 519px\" \/><\/figure>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u00c9l\u00e9ments cl\u00e9s de la norme ISO 7864 pour le contr\u00f4le de l'acuit\u00e9 des aiguilles<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>ISO 7864<\/strong> d\u00e9finit les exigences et les m\u00e9thodes d'essai pour <strong>aiguilles hypodermiques \u00e0 usage unique<\/strong>L'annexe D de la norme ISO 7864 d\u00e9crit les caract\u00e9ristiques de l'aiguille, en mettant l'accent sur la pr\u00e9cision de sa performance. Plus pr\u00e9cis\u00e9ment, l'annexe D de la norme ISO 7864 d\u00e9crit les \u00e9l\u00e9ments suivants <strong>test de p\u00e9n\u00e9tration \u00e0 l'aiguille<\/strong> La m\u00e9thodologie, qui mesure \u00e0 la fois les <strong>force de p\u00e9n\u00e9tration maximale<\/strong> et <strong>force de tra\u00een\u00e9e<\/strong> pendant l'insertion dans un substrat contr\u00f4l\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La m\u00e9thode ISO 7864 garantit la coh\u00e9rence et la reproductibilit\u00e9 des tests, ce qui permet aux fabricants d'avoir confiance dans la qualit\u00e9 et la s\u00e9curit\u00e9 de leurs produits.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Test d'aiguille de p\u00e9n\u00e9tration et test d'aiguille hypodermique<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le <strong>test de p\u00e9n\u00e9tration \u00e0 l'aiguille<\/strong> est un \u00e9l\u00e9ment fondamental de la <strong>test des aiguilles hypodermiques<\/strong>. Il comprend les \u00e9l\u00e9ments et les \u00e9tapes suivants :<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Appareil de mesure de la force<\/strong><br>Un dynamom\u00e8tre \u00e9quip\u00e9 d'une cellule de charge enregistre les forces agissant sur l'aiguille pendant le test. L'appareil maintient et d\u00e9place \u00e9galement l'aiguille en toute s\u00e9curit\u00e9 \u00e0 une vitesse de 1,5 m\/s. <strong>vitesse d'essai standard de 100 mm\/min<\/strong> pour une mesure pr\u00e9cise.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. S\u00e9lection du substrat<\/strong><br>Diff\u00e9rents substrats simulent les tissus humains et fournissent un support d'essai fiable. Les substrats les plus courants sont les suivants<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Caoutchouc naturel (40 \u00b1 5 Shore A)<\/li>\n\n\n\n<li>Polyur\u00e9thane (85 \u00b1 10 Shore A)<\/li>\n\n\n\n<li>Caoutchouc de silicone (50 \u00b1 5 Shore A)<\/li>\n\n\n\n<li>Film poly\u00e9thyl\u00e8ne LDPE (50 \u00b1 5 microns)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Le substrat choisi doit \u00eatre valid\u00e9 pour garantir des r\u00e9sultats coh\u00e9rents.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. Support de substrat<\/strong><br>Un porte-substrat bien con\u00e7u, avec des plaques parall\u00e8les, fixe solidement le substrat en place. Le <strong>zone de p\u00e9n\u00e9tration circulaire ouverte (diam\u00e8tre nominal : 10 mm)<\/strong> permet de r\u00e9aliser des tests pr\u00e9cis et de collecter des donn\u00e9es exactes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4. Profondeur de p\u00e9n\u00e9tration<\/strong><br>L'aiguille est ins\u00e9r\u00e9e \u00e0 une profondeur \u00e9gale \u00e0 <strong>80% de sa longueur nominale<\/strong> (par exemple, 4 mm pour une aiguille de 5 mm). Apr\u00e8s chaque essai, une nouvelle surface de substrat doit \u00eatre utilis\u00e9e pour \u00e9viter tout biais.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>5. Environnement de test<\/strong><br>Les essais doivent \u00eatre r\u00e9alis\u00e9s dans un environnement contr\u00f4l\u00e9 (18-28 \u00b0C ; 25-75% RH) afin d'\u00e9viter toute variabilit\u00e9.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">R\u00e9alisation du test d'acuit\u00e9 de l'aiguille<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour effectuer un examen approfondi <strong>test d'acuit\u00e9 de l'aiguille<\/strong>, suivez les \u00e9tapes suivantes :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Pr\u00e9parer les \u00e9chantillons d'essai et le substrat<\/strong>Les \u00e9chantillons sont ensuite soumis \u00e0 un contr\u00f4le de qualit\u00e9 qui consiste \u00e0 les conditionner pendant au moins 24 heures dans des conditions ambiantes normales de laboratoire.<\/li>\n\n\n\n<li><strong>Monter l'aiguille<\/strong> sur le dispositif de mesure de la force.<\/li>\n\n\n\n<li><strong>Fixer le substrat<\/strong> dans le support, en veillant \u00e0 l'aligner sur la zone cible de la p\u00e9n\u00e9tration.<\/li>\n\n\n\n<li><strong>Lancer le test de p\u00e9n\u00e9tration<\/strong> en d\u00e9pla\u00e7ant l'aiguille \u00e0 100 mm\/min jusqu'\u00e0 ce que la profondeur de p\u00e9n\u00e9tration souhait\u00e9e soit atteinte.<\/li>\n\n\n\n<li><strong>R\u00e9tracter l'aiguille<\/strong> et enregistrer le profil complet de la force.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Si, en raison d'un mauvais alignement, l'aiguille entre en collision avec le porte-substrat, abandonnez le test et refaites-le avec un \u00e9chantillon correctement align\u00e9.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Collecte et analyse des donn\u00e9es<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le <strong>profil de la force<\/strong> g\u00e9n\u00e9r\u00e9 pendant les essais saisit deux param\u00e8tres principaux :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Force de p\u00e9n\u00e9tration maximale<\/strong>: La force la plus \u00e9lev\u00e9e n\u00e9cessaire pour percer le substrat.<\/li>\n\n\n\n<li><strong>Force de tra\u00een\u00e9e<\/strong>: La force de frottement moyenne agissant sur l'aiguille lorsqu'elle traverse le substrat.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Calcul de la <strong>moyenne et \u00e9cart-type<\/strong> de ces param\u00e8tres garantit l'exactitude des rapports. La norme ISO 7864 recommande d'utiliser des \u00e9chantillons de taille statistiquement significative pour valider les donn\u00e9es d'essai.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Communication des r\u00e9sultats des tests d'acuit\u00e9 de l'aiguille<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un complet <strong>test d'acuit\u00e9 de l'aiguille<\/strong> Le rapport doit comprendre les \u00e9l\u00e9ments suivants<br>\u2705 Moyenne et \u00e9cart-type des <strong>force de p\u00e9n\u00e9tration maximale<\/strong><br>\u2705 Moyenne et \u00e9cart-type des <strong>force de tra\u00een\u00e9e<\/strong><br>\u2705 Description de l'environnement d'essai et des substrats utilis\u00e9s<br>\u2705 Confirmation de la conformit\u00e9 \u00e0 la norme ISO 7864<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ces rapports complets garantissent la transparence et la fiabilit\u00e9 de votre processus de test.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pourquoi choisir Cell Instruments pour tester la nettet\u00e9 des aiguilles ?<\/strong><br>Au <strong>Instruments cellulaires<\/strong>Nous sommes sp\u00e9cialis\u00e9s dans la fabrication et la fourniture d'instruments d'essai des mat\u00e9riaux avanc\u00e9s, y compris d'\u00e9quipements pour les applications suivantes <strong>test d'acuit\u00e9 de l'aiguille<\/strong>. Nos solutions de test fiables aident les fabricants \u00e0 r\u00e9pondre aux exigences de la norme ISO 7864 et \u00e0 garantir la s\u00e9curit\u00e9 des produits et le confort des patients. Nous fournissons \u00e9galement des solutions de test et d'automatisation personnalis\u00e9es pour r\u00e9pondre \u00e0 vos besoins uniques, dans des secteurs tels que le m\u00e9dical, le pharmaceutique et le contr\u00f4le de la qualit\u00e9.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Test d'acuit\u00e9 de l'aiguille<\/strong> est une \u00e9tape indispensable pour garantir que les aiguilles m\u00e9dicales r\u00e9pondent aux normes internationales de s\u00e9curit\u00e9 et de performance. En suivant les directives claires de la norme ISO 7864 et en utilisant un \u00e9quipement d'essai pr\u00e9cis, les fabricants peuvent s'assurer que leurs aiguilles hypodermiques r\u00e9pondent aux normes de qualit\u00e9 et de fiabilit\u00e9 les plus \u00e9lev\u00e9es. Contact <strong>Instruments cellulaires<\/strong> d\u00e8s aujourd'hui pour savoir comment nous pouvons r\u00e9pondre \u00e0 vos besoins en mati\u00e8re de tests !<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>FAQ sur le test d'acuit\u00e9 de l'aiguille<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1 : Quel est l'objectif des tests d'acuit\u00e9 des aiguilles ?<\/strong><br>A1 : Il \u00e9value les forces d'insertion et de tra\u00een\u00e9e d'une aiguille afin de minimiser la douleur et les l\u00e9sions tissulaires, am\u00e9liorant ainsi le confort du patient.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2 : Quelles sont les normes qui r\u00e9gissent les tests d'acuit\u00e9 des aiguilles ?<\/strong><br>A2 : <a href=\"https:\/\/www.iso.org\/standard\/60481.html\" target=\"_blank\" rel=\"noreferrer noopener\">ISO 7864<\/a> d\u00e9crit les proc\u00e9dures requises et les crit\u00e8res de performance pour l'analyse des aiguilles hypodermiques.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3 : Quels sont les substrats utilis\u00e9s pour les essais ?<\/strong><br>A3 : Les substrats courants sont le caoutchouc latex naturel, le polyur\u00e9thane, le caoutchouc silicone et les films LDPE.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4 : Comment la force de tra\u00een\u00e9e est-elle calcul\u00e9e dans les tests d'acuit\u00e9 de l'aiguille ?<\/strong><br>A4 : Elle est d\u00e9termin\u00e9e en calculant la force de frottement moyenne \u00e0 partir de 80% de la r\u00e9gion de profondeur de p\u00e9n\u00e9tration sur le profil de force.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q5 : Cell Instruments peut-il fournir des solutions personnalis\u00e9es pour les tests d'acuit\u00e9 des aiguilles ?<\/strong><br>R5 : Oui, nous proposons des \u00e9quipements d'essai et des solutions d'automatisation sur mesure pour r\u00e9pondre \u00e0 vos besoins sp\u00e9cifiques en mati\u00e8re d'essais de produits.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>ISO 7864 Essai de nettet\u00e9 des aiguilles hypodermiques Principaux \u00e9l\u00e9ments de l'ISO 7864 pour l'essai de nettet\u00e9 des aiguilles L'ISO 7864 d\u00e9finit les exigences et les m\u00e9thodes d'essai pour les aiguilles hypodermiques \u00e0 usage unique, en mettant l'accent sur la pr\u00e9cision des performances de l'aiguille. Plus pr\u00e9cis\u00e9ment, l'annexe D de l'ISO 7864 d\u00e9crit la m\u00e9thodologie du test de p\u00e9n\u00e9tration de l'aiguille, qui mesure \u00e0 la fois la force de p\u00e9n\u00e9tration maximale et la tra\u00een\u00e9e [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2139","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/fr\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 7864 Hypodermic Needle Sharpness Testing Key Elements of ISO 7864 for Needle Sharpness Testing ISO 7864 sets out the requirements and test methods for hypodermic needles for single use, focusing on precise needle performance. Specifically, Annex D of ISO 7864 outlines the penetration needle test methodology, which measures both peak penetration force and drag\u2026","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2139","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/comments?post=2139"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2139\/revisions"}],"predecessor-version":[{"id":2502,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2139\/revisions\/2502"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/media?parent=2139"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/categories?post=2139"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/tags?post=2139"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}